Technical content

The C7336 series consist of a high resolution, high contrast 4- inch X-ray image intensifier (X-ray I.I.) and a 2.8 megapixel CMOS image sensor. The X-ray I.I. used has a fixed field of view of 100 mm diameter or a 4 inches/2 inches adjustable field-of-view and an input window made of thin aluminum which is excellent in X-ray transmission and causes less scattering of X-rays. These features allow real-time detection at X-ray energy levels from about 20 keV. The captured images can be transferred to PC directly by interface of IEEE1394b.

APPLICATIONS

GIndustrial X-ray CT scanner GIn-line X-ray inspection system

FEATURES

GHigh resolution, high contrast GHigh-speed readout GLow noise GLow distortion X-RAY I.I. DIGITAL CAMERA UNIT SERIES C7336-05/-52 X-RAY IMAGING [Suitable samples]

  • Electronic parts • Printed circuit boards • Resin parts
  • Metallic parts • Food products
  • Beverage products • Pharmaceuticals GDigital type (C7336-05) IBGA X-ray tube voltage: 80 kV X-ray tube voltage: 80 kV GAnalog type Clear, Sharp Image

74 × 56 Approx. 8 Approx. 9 4-inch mode 2-inch mode 4-inch mode 2-inch mode 30(12) 73 × 55 37 × 28 100 45(8)30(12) 45(8) Aluminum / 0.5 mm Csl P43 Scientific CMOS image sensor FL-280 1920 × 1440 3.63 × 3.63 IEEE 1394b power supply / DC8 V to 30 V IEEE 1394b bus × 2 cable 9-pin IEEE 1394b connector AC100 V to 240 V (50 Hz / 60 Hz) +10 to +40 -10 to +45 Below 70 % (no condensation) Approx. 0.5 C7336-52C7336-05 mm Lp/cm µm frames/s(bit) VA kg kg Unit Input Window Material / Thickness Input Phosphor Output Phosphor Imaging Area (H × V) (on Input Surface) Typ. Resolution (on Input Surface) Typ. Digital camera section Camera Connector Input Voltage Power Consumption Operating Ambient Temperature Storage Temperature Operating and Storage Humidity Weight Imaging Device Number of Effective Pixels (H × V) Pixel Size (H × V) Frame Rate(Signal Output) Power Consumption Interface Head DC24 V Power Supply Parameter ILithium ion battery X-ray tube voltage: 100 kV ILED X-ray tube voltage: 90 kV LTop view LSide view IBGA X-ray tube voltage: 130 kV L4-inch mode L2-inch mode

DIMENSIONAL OUTLINES (Unit: mm) Head

24 V DC Power Supply

120.0 ± 0.5 40 136.0 ± 0.5 4-M6 DEPTH 15 (X-RAY I.I. MOUNTING SCREW HOLES) 205 ± 2 226 ± 2 130 ± 2 154 ± 2 DC24 V CONNECTOR IEEE 1394b CONNECTOR × 2 FIELD OF VIEW SWITCHING CABLE 100 ± 2 164 ± 2 293 ± 3 212 ± 2 There is no field of view switching cable in C7336-05. DC POWER SUPPLY AC IN DC OUT 140 110 130 FRONT VIEW REAR VIEW

RELATED PRODUCTS (Analog type X-ray I.I. camera unit) TXPR1017E04 SEPT. 2014 IP Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2014 Hamamatsu Photonics K.K. Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Unit Configuration: X-ray I.I. Head + DC 24 V Power Supply for X-ray I.I. TXPRC0006ED HAMAMATSU PHOTONICS K.K. HAMAMATSU PHOTONICS K.K., Electron Tube Division 314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205 www.hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 SE-164 40 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se *10 m cable is also available. DC POWER SUPPLY X-RAY SOURCE SAMPLE HIGH-VOLTAGE POWER SUPPLY X-RAY I.I. X-RAY I.I. HEAD PC WITH FRAME GRABBER 2-WIRE FOR FIELD OF VIEW SWITCHING CABLE (C7336-52) IEEE 1394b CABLE (INCLUDING BUS POWER) IEEE 1394b CABLEDIGITAL CMOS CAMERA DC 24 V POWER SUPPLY AC 100 V to 240 V 10 VA CABLE LENGTH: 5 m* CABLE LENGTH: 5 m CONFIGURATION C7876 (4-inch beryllium input window type for low energy imaging) The C7876 uses beryllium (Be) for the input window of the X-ray image intensifier to give drastically improved X-ray transmittance in the low energy X-ray range. This window makes the C7876 ideal for non-destructive inspection of light- element materials in the low energy X-ray region and also for synchrotron radiation imaging. Internal structures of thin plastics and aluminum products that have long been difficult to obtain a high-contrast X-ray image can now be viewed at high contrast in real time. C7336-50 (4-inch / 2-inch dual mode type capable of high magnification) The C7336-50 uses a variable field of view type X-ray image intensifier that captures high contrast X-ray images and displays them in real time at high magnification. In 2-inch mode the C7336-50 captures images that are magnified twice inside the X-ray I.I. tube, making this camera ideal for inspecting electronic components and printed circuit boards whose structures and patterns will become ever tinier and more complex in the near future.