C7169 HAMAMATSU | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Related Products
Power Supply for PMT Modules C7169 The C7169 is a power supply unit for driving photosensor modules. Both drive volta- ges and control voltages can be supplied from this one unit. Applicable products: H5773/H5783/H6779/H6780 Series, H5784 Series H7710/H8567 Series, H7711/H7712/H8568/H8569 Series H7732 Series, H7826 Series, H7827 Series, H8249 Series Output Voltage Input Current Control Voltage (variable voltage range) AC Input Voltage Input Power Frequency Operating Ambient Temperature Storage Temperature Output Connector Dimensional Outlines Weight Max. Input Output Power Max. ±15 0 to +1.2 100 to 240 +5 to +50 -20 to+50 Binding post 147 × 61 × 200 Approx.1.2 V A V V Hz mm kg ValueParameter Unit Amplifier Units These are amplifier units for photomultiplier tubes and current output type PMT modules. C7319: Switchable between 2 frequency bandwidths and 3 current/voltage conversion coefficients. Ideal for applications requiring low noise and high gain. C6438: Wide bandwidth from DC to 50 MHz and gain of 20 dB. (-01 type is 54 dB) C5594: High cut off frequency of 1.5 GHz. Faithfully amplifies high-speed output pulses. The input/output connector can be selected from the SMA or BNC types. Frequency Bandwidth (-3 dB) Voltage Gain Current-to-Voltage Conversion Factor Amplifier Input (output) Input Impedance Recommended Load Resistance Max. Output Signal Voltage Connector Input Voltage Input Current Dimensions Weight *1: Frequency bandwidth is limited to DC to 100 kHz at conversion coefficient of 10 V/µA. *2: C7319 is current input type. *3: At ±15 V Supply voltage and 10 kΩ load resistance. *4: At 50 Ω load resistance. *5: Value after current-to-voltage conversion by input impedance. *6: Contact our sales office for other connectors for C5594. DC to 20 kHz or DC to 200 kHz (switchable)*1 — *2 100 mV/µA, 1 V/µA or 10 V/µA (switchable) ±Current (inverted) — *2 ±13 *3 BNC-R BNC-R DIN (6-pin) ±5 to ±15 ±16 60 × 43.2 × 65 Approx.170 dB Ω Ω V V mA mm g C7319 DC to 50 MHz 20 ± 3 *4 (approx. 10 times) 0.5 mV/µA *5 ±Voltage (non-inverted) ±1 *4 BNC-R BNC-R DIN (6-pin) ±55 60 × 43.2 × 65 Approx.160 C6438 DC to 50 MHz 54 ± 3 *4 (approx. 500 times) 25 mV/µA *5 ±Voltage (non-inverted) ±1 *4 BNC-R BNC-R DIN (6-pin) ±80 60 × 43.2 × 65 Approx.160 C6438-01 50 kHz to 1.5 GHz 36 *4 (approx. 63 times) 3.15 mV/µA *5 -Voltage (non-inverted) -2.5 *4 BNC-R BNC-R +12 to +16 +95 54 × 17 × 33 Approx.80 C5594-44 *6Parameter Unit From left: C7319, C6438, C5594-44
Data Acquisition Units C8907, C8908 The C8907 and C8908 data acquisition units have a signal processing circuit that con- verts analog signals of a PMT module into digital data for output to a PC (personal conputer). Gate time/Integration time, number of reading and photomultiplier tube gain can be controlled from the PC. The C8907 and C8908 also provide output voltage necessary to operate a PMT module, making device setup and connection easier. ns bit ms ms V —H7826P , H7826P-01, H7732P-01, H7732P-11, H5783P* H7826 Series, H7732 Series, H6780 Series* H5783 Series*, H7710 / H8567 Series* RS-232C Power cable (6-pin) RS-232C cross cable Charge amp + ADC + CPU + interface 0.04 to 500 0.01 to 500 1 to 127 C8908 Unit *: We can install a signal connector (BNC-P) and a power input connector (HIROSE HR 10A-7P-6P) to the cable ends of an applicable PMT module if needed (extra charge). Please specify the type of connector when placing your order. Photon Counting Units C3866, C6465 These photon counting units contain an amplifier and discriminator to convert the sin- gle photoelectric pulses from a photomultiplier tube into a 5 V digital signal. The C3866 has an output linearity up to 1 × 10
7 S-1, and a high-speed counter is not
required when set to division by 10. The C6465 has an output linearity up to 1 × 10
6 S-1, and an output pulse width of 30 ns
allows it to be used with a general-purpose counter. LLeft: C3866 Right: C6465 Input Impedance Discrimination Level (input conversion) Gain Required in PMT Prescaler Count Linearity Pulse-pair Resolution Output Signal Level Output Pulse Width Supply Voltage Connector Dimensions Weight Input Output Remote Power Ω mV s ns ns mm g -0.5 to -16 3 × 10 C-MOS BNC-R BNC-R BNC-R HIROSE SR30-10R-4S * 88 × 32 × 170 Approx. 320 4 × 106 1 × 107 Depends on count rate. C3866 -2.2 to -31 5 × 106 1 × 106 TTL positive logic +5 V, 60 mA/-5 V, 120 mA BNC-R BNC-R DIN (6-pin) * 60 × 43.2 × 105 Approx. 250 C6465Parameter Unit *1: Supplied with a cable (1 m) attached to the mating plug (HIROSE SR30-10PQ-4P). *2: Supplied with a cable (1.5 m) attached to the mating plug. Configuration Pulse-pair Resolution ADC Resolution Interface Gate Time / Integration Time Dead Time Number of Reading at Fixed Set Reading Supply Voltage Accessories (supplied) Applicable PMT Modules Photon counting circuit + counter + CPU + interface 10 to 1000 (10 step) C8907Parameter Left: PMT module (sold separately)s Right: C8907, C8908
Supplied: CD-ROM (containing instruction manual, device driver, DLL, sample software, etc.), Signal input cable (E1168-22), General-purpose I/O connector (JAE: TXA20A-26PH1-D2P1-D1), Connection cable set (JAE: XHP-3, XHP-4) *: Sample software is configured from Lab VIEW™ of National Instruments, Inc. : Conforms to the EMC directive (89/336/EEC) of the European Union. The M8784 counting board is a PCI bus add-in board type counter. The M8784 func- tions as a photon counter when combined with a photon counting head, etc. The counter of the M8784 includes two counting circuits (double counter method) ca- pable of counting input signals with no dead time. The internal memory allows pulse counting over extended periods with a high time resolution (10 µs). A maximum of two M8784 boards can be simultaneously controlled from a PC, mak- ing it possible to perform simultaneous dual-channel measurements. Initial setting for the M8784 is simple and easy due to PnP (plug and play). You can start measurement on the day you receive the M8784. The M8784 is designed to install into a PCI bus slot of desktop computers and cannot be used with notebook-sized computers. When using a notebook computer, use the C8855 counting unit also available from Hamamatsu.
- Also ideal for long-term data collection such as in biological clock monitoring *) This is an ideal feature when the time needed to record count data in the memory is longer than the time needed to transfer the count data to a PC and write it into the storage medium. This allows time-resolved measurement (minimum resolution: 10 µs) over a long period of time . Memory recording time is calculated from "counter operation time × memory length". (Example: minimum resolution 10 µs × maximum memory length 256 000 = 2.56 s) *) Standard sample software may not work at some conditions depending on the combination of measuring time and time resolution. Please consult with our sales office in advance with information of your condition.
- Time-resolved measurement of chemiluminescence (minimum resolution 10 µs)
- Supports different kinds of measurements The M8784 is fully controlled by DLL (dynamic link library) functions that come with the M8784. All information on these DLL functions is available to support software programming that handles various types of user measurement applications. Input Counter Counter Gate Trigger Memory General Output Section Compatible OS Bus Type Supply Voltage Size Weight Operating Ambient Temperature/Humidity Number of Input Signals Signal Input Level Signal Pulse Width Input Impedance Counter Method Max.Count Rate Max.Counter Capacity Counter Gate Mode Internal Counter Gate Time External Counter Gate Time Trigger Method External Trigger Signal Memory Method Memory Capacity Memory Date Width Signal Input Signal output 1 ch TTL positive logic 8 ns or longer 50 Ω Double counter method
50 MHz
Internal, external, START -STOP 10 µs to 10 s (1, 2, 5 step) 100 ns or more Software or external trigger TTL negative logic Double memory method 128 000 (when capacity of 232 is selected) / 256 000 (when capacity of 216 is selected) 232 (32 bit) / 216 (16 bit) TTL negative logic / 8 bit Open collector / 8 bit Windows® 98/98SE/Me/2000 PCI
5 V / 1 A (supplied from PCI bus)
+5 °C to +45 °C / 80 % or less (no condensation) Description / ValueParameter
The C8855 is a counting unit with a USB interface and can be used as a photon counter when combined with a photon counting head, etc. The counter of the C8855 has two counter circuits (double counter method) capable of counting input signals with no dead time. The USB interface easily connects to a notebook PC allowing measurement in an even wider application field. When used with a photon counting head, the C8855 supplies power (+5 V / 200 mA) necessary to operate the photon counting head. Since the C8855 is hot-swap compatible (plug and play compatible), it helps you set up measurement environment quickly. You can start measurement on the day the C8855 is delivered by using the sample software that comes with the C8855. The C8855 cannot be used in simultaneous dual- channel measurements or long-time measurements with a fast time resolution. In such applications, use the M8784 counting board also available from Hamamatsu.
- Time-resolved measurement (minimum resolution: 50 µs) for monitoring chemiluminescence and biological clocks
- Quick measurement setups (hot-swap compatible) When software such as a device driver is installed into your PC beforehand, you can start measurement by just connecting the USB cable, without restarting the PC.
- Applicable to various measurement methods The C8855 is fully controlled by DLL (dynamic link library) functions that come with the C8855. All information on these DLL functions is available to support software programming that handles various types of user measurement applications. Input Counter Counter Gate Trigger General Output Section Voltage Output Compatible OS Interface Supply Voltage Dimensions Weight Operating Ambient Temperature/Humidity AC Adapter Number of Input Signals Signal Input Level Signal Pulse Width Input Impedance Counter Method Max.Count Rate Max.Counter Capacity Counter Gate Mode Internal Counter Gate Time Trigger Method External Trigger Signal Input Output 1 ch TTL positive logic 8 ns or longer 50 Ω Double counter method
Internal counter gate only 50 µs to 10 s (1, 2, 5 step) Software or external trigger TTL negative logic Open collector / 2 bits +5 V / 200 mA Max. Windows® 98/98SE/Me/2000 USB (Ver. 1.1) +5 V / 500 mA Max. (supplied from accessory AC adapter) (W): 148 mm × (D): 96 mm × (H): 30 mm (excluding rubber feet and projecting parts) 300 g +5 °C to +45 °C / 80 % or less (no condensation) AC 90 V to AC 260 V 7 V / 1.6 A Description / ValueParameter Supplied: CD-ROM (containing instruction manual, device driver, DLL, sample software, etc.) USB cable, AC adapter, AC cable, power output connector *: Sample software is configured from Lab VIEW™ of National Instruments, Inc. : Conforms to the EMC directive (89/336/EEC) and the low voltage directive (73/23/EEC) of the European Union.