C430 POWEREX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Powerex, Inc. Hillis Street, Youngwood, Pennsylvania 15697 (412) 925-7272 Phase Control SCR 500-1300 Volts

Description

y Powerex Silicon Controlled Rectifiers SI (SCR) are designed for phase control al —— FS \\\\ applications. These are all-diffused, ae od, Dye Press-Pak (Pow-R-Disc) devices + ER employing the field-proven amplifying - ©TO wv cA + (di/namic) gate. Features: UY — as a4, caso contro! SCR 1 Low On-State Voltage _ r ase Control 7 6 =H 680 Amperes/500-1300 Volts O High divdt [Re N 0 High dv/dt ; (0 Hermetic Packaging Excellent Surge and It Ratings C430 Outline Drawing Applications: CD Power Supplies Millimeters — L_tetee T C1 Battery Chargers Dimensions] in| We | Wi a 1 Motor Contr a | seo] cos | s42e| 1507 (Ugh Dimmers B | 965 | 295 | 25.01] 25.27 (VAR Generators c ast dD | ool — | wel — Ordering Information E | oo | — | torf — Example: Select the complete five or six G 1.50 digit part number you desire from the H | 16 | 191 | 472] 485 table — i.e. C430PB is a 1200 Volt, 680 J | 245 | 255 | 6.22] 6.48 Ampere Phase Control SCR. k [115 [130 [2.92] 3.30 _ToTO t__ | 064 | 070 [1.62 [4.78 Twe Wings Sorrent N= fas05 |= 14028 [Fete | ni p | 195 | 145 [3.42] 3.68 cago [500 [| & | 680 s 5951 T__| 197 | 163] 347] a8 | coo [ Nn | | soo [+ | | 1000 [P| 175

a Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (412) 925-7272 430 Phase Control SCR

680 Amperes Avg/500-1300 Volts

RMS On-State Current Irawsy 1070 Amperes Average On-State Current Ineo 680 Amperes Peak Ona-Cycle Surge (Non-Repetitive) On-State Current (60Hz) hrs 8000 Amperes Peak One-Cycle Surge (Non-Repetitive) On-State Current (50Hz) brs 7300 Amperes Critical Rate-of-Rise of On-State Current (Non-Repetitive) di/dt 400 Amperes/ps Critical Rate-of-Rise of On-State Current (Repetitive) di/dt 150 Amperes/ps Pt (for Fusing), One Cycle at 60Hz Ft 265,000 Atsec Peak Gate Power Dissipation Pow 20 Watts: Average Gate Power Dissipation Poe 5 Watts: Storage Temperature Tsra —40 to 150 c Operating Temperature tw —40 to 125 Cc Mounting Force® 800 to 2500 Ib. Mounting Force® 3.6 to 11.1 KN © Consult recommended mounting procedures. 176

Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (412) 925-7272 c430 Phase Control SCR Electrical and Thermal Characteristics Characteristics Symbol Test Conditions 430 Units Voltage—Blocking State Maximums Forward Leakage, Peak ori Ty = 125°C, V = Von 20 mA Reverse Leakage, Peak ui Ty = 125°C, V = Varw 20 mA Current—Conducting State Maximums Peak On-State Voltage Vw Te = 25°C, = 3000A Peak, 24 Volts Duty Cycle 0.01% Switching Typical Turn-Off Time ty Ty = 125°C; Imm = 500A, Va = 50V min; 125 psec Vor (Reapplied); Reapplied dv/dt = 20V/ysec (linear); Commutation di/dt = 25A/usec; Repetition Rate = 1 pps; Gate Bias during turn-off interval = OV; 1000 Typical Delay Time ta Te = 25°C, ly = 50A, 0.7 psec Gate Supply: 20 Volts, 200, 0.1psec rise time Min. Critical dv/dt exponential to Vora dv/dt T, = 125°C, Voam = fated, Gate Open 200 V/psec Thermal Maximum Thermal Resistance, double sided cooling Junction to Case (2000 Ib. force) Rare 04 *C/Watt Cese to Sink, Lubricated (2000 Ib. force) Recs 02 *C/Watt Gate—Maximum Parameters Gate Current to Trigger ler Vp = 6Vde, T, = 25°C, Ri = 39 125 mA Gate Voltage to Trigger Ver Ts = — 40°C to 125°C, Vo = 6Vde, Ri = 30 5 Volts Non-Triggering Gate Voltage Voom Ty = 125°C, rated Vora, Ry = 1000 15 Volts Peak Forward Gate Current Norw 10 Amperes Peak Reverse Gate Voltage Vor 5 Volts © Consutt recommended mounting procedures. 177

Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (412) 925-7272 C430 Phase Control SCR MAXIMUM ON-STATE CHARACTERISTICS Ca ENT Ties UUNCTION TO ASE) g 70 g SScitaetenraeer: dee eof a aS 28° Fert Ht emer tri oe arte a 4 teen i ee eS za ES PE ogee ENE OPES ob HEE E3o/ | AA S COO 2° et i ool LAL UII TTT ETT TI 2.0 7 7 Scenes Ss SS i pao eee Seaiiicemetiseaiaiaeerineesiany oP | FE at Z 9 Ce cool U[MT TMM TIT TTT TT 2 102 103 10¢ 6" 10° o 10" 10° ry INSTANTANEOUS ON-STATE CURRENT, Inu, (AMPERES) TIME, t, (SECONDS) MAXIMUM ALLOWABLE CASE TEMPERATURE MAXIMUM ON-STATE POWER DISSIPATION e (SINUSOIDAL WAVEFORM) (SINUSOIDAL WAVEFORM) wa Whee ! RRO bel | EYAL SARS i. |/WAry | PANRRONE Tye PCOVANALEN i-§+$(Yr- & VAAN ISS i. fr~ | & iiteyeree ros 6 61a 505 100 200 300 400 $00 600 700 800 900 1000 ICO ° 200 ‘400 600 B00 AVERAGE ON-STATE CURRENT, Iriew (AMPERES) AVERAGE ON-STATE CURRENT, Irie (AMPERES) ; MAXIMUM ALLOWABLE CASE TEMPERATURE MAXIMUM ON-STATE POWER DISSIPATION e (RECTANGULAR WAVEFORM) (RECTANGULAR WAVEFORM) 130 = 1400; PoNRRCEC ET a ys a4 E 100 PARE a J sae — Aa SGus pa Za

80 KV SOAS MZ

4 ot | WAINS ENH | LC a i - PLA AS Naw a YZ SS sou | \\ NV i ol A a 3 50 F cycle 16.7 bc 3 | A 0 RISTO i 0 100 200 300 400 500 600 700 800 90010001100 = °6 0S wo 600, 00

178 AVERAGE ON-STATE CURRENT, Inam (AMPERES) AVERAGE ON-STATE CURRENT, Inu (AMPERES)

mR REP SIE SE MRD RE 5 PSL AA Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (412) 925-7272 Prove Control SCR MAXIMUM ALLOWABLE CASE TEMPERATURE MAXIMUM ALLOWABLE CASE TEMPERATURE 8 ‘so {SINUSOIDAL WAVEFORM) ¢ 130 (RECTANGULAR WAVEFORM) edd sets! 5 soe tI TT TT ART eR i ANNE 4. ||] F cot AL a \\\\NNSe 2 ARESN eee y ot LARAN lear | | § so INN ss 5 at | VAYANN TT § ot LH AKNN NIT 2“) eee (NSS LT 2 ot | IVANNIN UT CCEEEPEPPSTPBN 0g Slat La NONNCD Gey 2 co Ni F ‘ 2 tom. TTT te | TEN] PLU Ty NI Fy 505 100 200 300 400 500 600 700 AVERAGE ON-STATE CURRENT, Ine, (AMPERES) AVERAGE ON-STATE CURRENT, Ineo, (AMPERES) MAXIMUM ALLOWABLE CASE TEMPERATURE MAXIMUM ALLOWABLE CASE TEMPERATURE 8 (SINUSOIDAL WAVEFORM) 8 (RECTANGULAR WAVEFORM) 130) 130 WHO 7 of NON 5 ot NWN THe al ANNs oe eS SEE oe 4 ERAANRN aaa V N Bt x : HAYSN = § LEAN NNNESXEL TS fot AAAAL NOT 4 of +A AN-ANH De AAACN 7 otis’ hae Ne BY 2 od “petite UNI [Nb | % “o-oo 200 300 «00 600 G00 7OD 600 6007000¥700 = 8 100 200 300 400 S00 €00 700 600 $00 1000 1100 = 0 10 400 600 00 AVERAGE ON-STATE CURRENT, Ini (AMPERES) AVERAGE ON-STATE CURRENT, Ina (AMPERES) MAXIMUM ALLOWABLE CASE TEMPERATURE MAXIMUM ALLOWABLE CASE TEMPERATURE 8 (SINUSOIDAL WAVEFORM) 8 (RECTANGULAR WAVEFORM) 130 0 fw LULL lr tetel 1 s -RTTLLLILLL i a NS 1200 LB WOUNTING FORCE = y . NCCC _toraoate oR \\NGHEE(7 ann a \\\\NGSR 2 3 109) NG on Ae ¢ BENNSS TPERANANE hrouen dt” ae E 99 NNN Single Side Cooled

2 LOAN PFT 8 ol | AANNA IT

2 PRANK # ot LUNANNONCTT TT

3+ PITTiirirTi Ny Fi ar 100 200 300 400 500 600 700 AVERAGE ON-STATE CURRENT, hin (AMPERES) AVERAGE ON-STATE CURRENT, hen (AMPERES) 179

Powerex, Inc., Hillis Street, Youngwood, Pennsylvania 15697 (412) 925-7272 Cc Passe Control SCR SUB-CYCLE SURGE AND I’t RATINGS MAXIMUM ALLOWABLE SURGE ON-STATE =z (RATED LOAD CONDITIONS) CURRENT (NON-REPETITIVE) e (TTT ULE es Oa ai i: er | Se on a ae A Be | eee2 r Coo PSS TT Gee ee oSsacder eee 2a Bet eT ae af Nee Ae tee TL TTT 2 CCT SBS ais 3 = 2 | r-tiiin t s Senet je PULSE WIOTH, t,. (msec) CYCLES AT 60 HZ GATE CHARACTERISTICS soo TTT gt SO gE aI RON RS TINTS LN Ns

3 Ea sa

| N Tl i VI se CTH i Cy Peete i Tee Te Lil

2 The oct Ot toe points lie outside the boundaries shown at

  1. Tp = Rectangular gata currant pulse width (Sys min. duration; 1.05 max. 4. 20V - 209 is the minimum gate source load fine when rate of circuit current fg > 00 Ap or arora of cron a >200 Amps/us (Tp = Sus 180