BW9N0HA FUJI | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 93
Technical content
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice G-TWIN Standard Series (IEC/EN/GB/JIS conformed) Line protection AC415V BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 Icu 1.5kA AAG AAG AAG 2.5kA SAG EAG EAG 7.5kA SAG SAG 10kA RAG RAG EAG 18kA EAG EAG 30kA JAG JAG JAG EAG 36kA SAG SAG SAG SAG EAG EAG 50kA RAG RAG RAG RAG RAG RAG 65kA HAG* HAG* HAG* 70kA HAG HAG HAG Note: * There are no performance indications for GB standards for the BW50HAG, BW125HAG, and BW250HAG. G-TWIN Global Series (IEC/EN/GB/JIS/UL/CSA conformed) Line protection AC415V BW50 BW100 BW125 BW250 BW400 BW630 BW800 Icu 10kA RAGU EAGU 18kA EAGU 30kA JAGU JAGU EAGU 36kA SAGU 50kA RAGU RAGU RAGU RAGU RAGU 70kA HAGU HAGU HAGU BW0 Series (IEC/EN/GB conformed) Line protection AC415V 100AF 160AF 250AF Icu 15kA BW103E0 18kA BW162E0 BW163E0 BW252E0 BW253E0 25kA BW162J0 BW163J0 BW252J0 BW253J0 30kA BW102S0 BW103S0 36kA BW162S0 BW163S0 BW252S0 BW253S0 S, H Series Line protection AC415V 50AF 100AF 225AF 400AF 600AF 800AF 1000AF 1200AF 1600AF Icu 65kA H52BA H53BA H102BA H103BA H202BA H203BA SA1003E SA1004E SA1203E SA1204E 85kA H103R H203R SA1603E SA1604E 125kA H403R H603R H803R Molded Case Circuit Breakers List of products Motor protection AC415V BW32 BW50 BW63 BW100 BW125 BW250 Icu 1.5kA AAM 2.5kA SAM EAM EAM 7.5kA SAM SAM 10kA RAM EAM 18kA EAM 30kA JAM JAM 50kA RAM RAM F Series Distribution Breakers AC240V 50AF 100AF Icu 3kA F51B F52B F53B F102B F103B H Series Motor protection AC415V 50AF Icu 65kA H53BAM
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Type number nomenclature Molded Case Circuit Breakers G-TWIN series Type number nomenclature Rated current See page 06/29. No. of poles 2P: 2-pole 3P: 3-pole 4P: 4-pole G-TWIN series Blank: Standard U: Global Model G: Line protection M: Motor protection Breaking capacity Rated breaking capacity Icu (440V AC) 32AF 50AF 63AF 100AF 125AF 160AF 250AF 400AF 630AF 800AF EA 1.5kA 2.5kA 2.5kA 10kA – 18kA 18kA 30kA 36kA 36kA SA 2.5kA 7.5kA 7.5kA – 36kA 36kA 36kA 36kA – – RA – 10kA 10kA – 50kA 50kA 50kA 50kA 50kA 50kA HA – 65kA – – 65kA – 65kA 70kA 70kA 70kA Frame size 32: 32AF 63: 63AF 125: 125AF 250: 250AF 630: 630AF 50: 50AF 100: 100AF 160: 160AF 400: 400AF 800: 800AF Series BW: G-TWIN series MCCB BW 250 EA G - 3P 225 X Mounting and connection
- Standard type Blank: Front mounting front connection X: Front mounting rear connection E: Flush mounting rear connection Y: Flush mounting , top & buttom connection P: Plug-in mounting Auxiliary switch* W: Standard SPDT V: Standard 2PDT 1: For low level circuit SPDT 2: For low level circuit 2PDT Alarm switch* K: Standard SPDT J: Standard 2PDT 8: For low level circuit SPDT 9: For low level circuit 2PDT Undervoltage trip device (Internal)*
- 125/160/250AF • 400/630/800AF : DC24V AC/DC24V : DC48V AC/DC48V : DC100-110V AC/DC100-110V : DC125V AC120-130V / DC125V : AC100-110V AC200-240V / DC200-220V : AC110-130V AC277V : AC200-240V AC380-480V : AC277V : AC380-415V : AC440-480V Undervoltage trip device (External)*
- 32/50/63/100AF : DC24V : DC100-110V : AC100V (50Hz) / AC100-110V (60Hz) : AC200V (50Hz) / AC200-220V (60Hz) : AC400V (50Hz) / AC400-440V (60Hz) Connection method (internal accessories) Blank: Lead-wire system A: Terminal block system W K F R A Q2 M UC * For the available configuration of accessory, see page 06/68. Shunt trip device (Internal)*
- 125/160/250AF • 400/630/800AF : AC/DC24V AC/DC24-48V : AC/DC48V AC 100-240V / DC100-220V : AC100-120V / DC100-110V AC277V : AC120-130V AC380-550V : AC200-240V / DC200-220V : AC277V : AC380-440V : AC440-480V : AC500-550V Shunt trip device (Internal)*
- 32/50/63/100AF : AC/DC24V : AC100-120V / DC100-110V : AC200-240V : AC380-450V Pad locking device Q2: Plate type With motor operating device (32 - 100AF) : DC100V AC100-110V AC200-220V Enclosure UC: Standard UV: Dust-proof (IP40) UW: Rain-proof (IP54) Terminal combination (Global type) Terminal position Applicable breaker type Code Blank Blank SB SF Line Screw Flat teminal Block terminal Flat teminal Screw Flat teminal Screw Block terminal Flat teminal Block terminal Load Screw Flat teminal Block terminal Flat teminal Flat terminal Screw Block terminal Screw Block terminal Flat terminal BW50 BW100, 125, 250 BW400, 630, 800
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Rated current See page 06/29. No. of poles 2P: 2-pole 3P: 3-pole 4P: 4-pole G-TWIN series Blank: Standard U: Global Model G: Line protection M: Motor protection Breaking capacity Rated breaking capacity Icu (440V AC) 32AF 50AF 63AF 100AF 125AF 160AF 250AF 400AF 630AF 800AF EA 1.5kA 2.5kA 2.5kA 10kA – 18kA 18kA 30kA 36kA 36kA SA 2.5kA 7.5kA 7.5kA – 36kA 36kA 36kA 36kA – – RA – 10kA 10kA – 50kA 50kA 50kA 50kA 50kA 50kA HA – 65kA – – 65kA – 65kA 70kA 70kA 70kA Frame size 32: 32AF 63: 63AF 125: 125AF 250: 250AF 630: 630AF 50: 50AF 100: 100AF 160: 160AF 400: 400AF 800: 800AF Series BW: G-TWIN series MCCB BW 250 EA G - 3P 225 X Mounting and connection
- Standard type Blank: Front mounting front connection X: Front mounting rear connection E: Flush mounting rear connection Y: Flush mounting , top & buttom connection P: Plug-in mounting Auxiliary switch* W: Standard SPDT V: Standard 2PDT 1: For low level circuit SPDT 2: For low level circuit 2PDT Alarm switch* K: Standard SPDT J: Standard 2PDT 8: For low level circuit SPDT 9: For low level circuit 2PDT Undervoltage trip device (Internal)*
- 125/160/250AF • 400/630/800AF : DC24V AC/DC24V : DC48V AC/DC48V : DC100-110V AC/DC100-110V : DC125V AC120-130V / DC125V : AC100-110V AC200-240V / DC200-220V : AC110-130V AC277V : AC200-240V AC380-480V : AC277V : AC380-415V : AC440-480V Undervoltage trip device (External)*
- 32/50/63/100AF : DC24V : DC100-110V : AC100V (50Hz) / AC100-110V (60Hz) : AC200V (50Hz) / AC200-220V (60Hz) : AC400V (50Hz) / AC400-440V (60Hz) Connection method (internal accessories) Blank: Lead-wire system A: Terminal block system W K F R A Q2 M UC * For the available configuration of accessory, see page 06/68. Shunt trip device (Internal)*
- 125/160/250AF • 400/630/800AF : AC/DC24V AC/DC24-48V : AC/DC48V AC 100-240V / DC100-220V : AC100-120V / DC100-110V AC277V : AC120-130V AC380-550V : AC200-240V / DC200-220V : AC277V : AC380-440V : AC440-480V : AC500-550V Shunt trip device (Internal)*
- 32/50/63/100AF : AC/DC24V : AC100-120V / DC100-110V : AC200-240V : AC380-450V Pad locking device Q2: Plate type With motor operating device (32 - 100AF) : DC100V AC100-110V AC200-220V Enclosure UC: Standard UV: Dust-proof (IP40) UW: Rain-proof (IP54) Terminal combination (Global type) Terminal position Applicable breaker type Code Blank Blank SB SF Line Screw Flat teminal Block terminal Flat teminal Screw Flat teminal Screw Block terminal Flat teminal Block terminal Load Screw Flat teminal Block terminal Flat teminal Flat terminal Screw Block terminal Screw Block terminal Flat terminal BW50 BW100, 125, 250 BW400, 630, 800 Molded Case Circuit Breakers G-TWIN series Type number nomenclature
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Ampere frame 32A Type BW32AAG BW32SAG Pole 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 3, 5, 10, 15, 20, 30, 32 Rated impulse withstand voltage Uimp(kV) 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 DC − 250* Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 500V − 1.5/1 440V 1.5/1 2.5/2 415V 1.5/1 2.5/2 400V 1.5/1 2.5/2 380V 1.5/1 2.5/2 240V 2.5/2 5/3 230V 2.5/2 5/3 DC 250V − 2.5/2* GB14048.2 AC 400V 1.5/1 2.5/2 230V 2.5/2 5/3 Conforming to standards CE Marking (TÜV) (TÜV) CCC certificate Electrical Appliance and Material Safety Law <PS>E*2 Dimensions (mm) a 50 75 50 75 b 100 100 c 60 60 d 84 84 Mass (kg) 0.4 0.5 0.4 0.5 Tripping device Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC 35mm wide rail mounting No-mark Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL − − − − : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circut breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan G-TWIN Standard Series c a d b Molded Case Circuit Breakers G-TWIN series Quick reference guide
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Ampere frame 50A Type BW50AAG BW50EAG BW50SAG BW50RAG BW50HAG Pole 2 3 2 3 2 3 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 5, 10, 15, 20, 30, 32, 40, 50 10, 15, 20, 30, 32, 40, 50 15, 20, 30, 40, 50 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 690 690 690 DC − 250* 250* 250* 250 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 500V − 1.5/1 5/3 7.5/4 25/7 440V 1.5/1 2.5/2 7.5/4 10/5 65/17 415V 1.5/1 2.5/2 7.5/4 10/5 65/17 400V 1.5/1 2.5/2 7.5/4 10/5 65/17 380V 1.5/1 2.5/2 7.5/4 10/5 65/17 240V 2.5/2 5/3 10/5 25/13 125/63 230V 2.5/2 5/3 10/5 25/13 125/63 DC 250V − 2.5/2* 5/3* 5/3* GB14048.2 AC 400V 1.5/1 2.5/2 7.5/4 10/5 – 230V 2.5/2 5/3 10/5 25/13 – Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) (TÜV) CCC certificate – Electrical Appliance and Material Safety Law <PS>E*2 Dimensions (mm) a 50 75 50 75 50 75 50 75 90 b 100 100 100 100 155 c 60 60 60 60 68 d 84 84 84 84 95 Tripping device Hydraulic-magnetic Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y – – Plug-in mounting P IEC 35mm wide rail mounting No-mark – – Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1/QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Earth BL – – Handle locking cover L1 Flat terminal SS : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circut breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan c a d b G-TWIN Standard Series Molded Case Circuit Breakers G-TWIN series Quick reference guide
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice G-TWIN Standard Series Ampere frame 63A Type BW63EAG BW63SAG BW63RAG Pole 2 3 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 60, 63 Rated impulse withstand voltage Uimp(kV) 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 DC 250* 250* 250* Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 500V 1.5/1 5/3 7.5/4 440V 2.5/2 7.5/4 10/5 415V 2.5/2 7.5/4 10/5 400V 2.5/2 7.5/4 10/5 380V 2.5/2 7.5/4 10/5 240V 5/3 10/5 25/13 230V 5/3 10/5 25/13 DC 250V 2.5/2* 5/3* 5/3* GB14048.2 AC 400V 2.5/2 7.5/4 10/5 230V 5/3 10/5 25/13 Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) CCC certificate Electrical Appliance and Material Safety Law <PS>E*2 Dimensions (mm) a 50 75 50 75 50 75 b 100 100 100 c 60 60 60 d 84 84 84 Tripping device Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC 35mm wide rail mounting No-mark Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Earth BL Handle locking cover L1 Flat terminal SS : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circut breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan c a d b Molded Case Circuit Breakers G-TWIN series Quick reference guide
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice G-TWIN Standard Series Ampere frame 100A Type BW100AAG BW100EAG Pole 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 60, 63, 75, 100 50, 60, 63, 75, 100 Rated impulse withstand voltage Uimp(kV) 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 DC − 250* Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 500V − 7.5/4 440V − 10/5 415V − 10/5 400V 1.5/1 10/5 380V 1.5/1 10/5 240V 5/3 25/13 230V 5/3 25/13 DC 250V − 5/3* GB14048.2 AC 400V 1.5/1 10/5 230V 5/3 25/13 Conforming to standards CE Marking (TÜV) (TÜV) CCC certificate Electrical Appliance and Material Safety Law <PS>E*2 Dimensions (mm) a 50 75 50 75 b 100 100 c 60 60 d 84 84 Mass (kg) 0.4 0.5 0.4 0.5 Tripping device Thermal -magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC 35mm wide rail mounting No-mark Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL − − − − : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circut breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan c a d b Molded Case Circuit Breakers G-TWIN series Quick reference guide
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice G-TWIN Standard Series Ampere frame 125A Type BW125JAG BW125SAG BW125RAG BW125HAG Pole 2 3 4 2 3 4 2 3 4 2 3 Rated current Reference amb. temp. (40°C) In(A) 15, 20, 30, 40, 50, 60, 75, 100, 125 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC 250 250 250 250 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 500V 5/3 8/4 10/5 10/5 25/7 440V 30/15 30/15 36/18 50/25 65/17 415V 30/15 30/15 36/18 50/25 65/17 400V 30/15 30/15 36/18 50/25 65/17 380V 30/15 30/15 36/18 50/25 65/17 240V 50/25 50/25 85/43 100/50 125/63 230V 50/25 50/25 85/43 100/50 125/63 DC 250V 15/8 15/8 30/15 40/20 40/20 GB14048.2 AC 400V 30/15 30/15 36/18 50/25 – 230V 50/25 50/25 85/43 100/50 – Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) CCC certificate – Electrical Appliance and Material Safety Law <PS>E*2 (except for 125A) (except for 125A) (except for 125A) (except for 125A) Dimensions (mm) a 60 90 120 90 90 120 90 90 120 90 b 155 155 155 155 c 68 68 68 68 d 95 95 95 95 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P – – – Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R – Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 – Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan c a d b Molded Case Circuit Breakers G-TWIN series Quick reference guide
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice G-TWIN Standard Series Ampere frame 160A Type BW160EAG BW160JAG BW160SAG BW160RAG Pole 2 3 2 3 4 2 3 4 2 3 4 Rated current Reference amb. temp. (40°C) In(A) 125, 150, 160 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC 250 250 250 250 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 690V – – – – 500V 5/3 8/4 10/5 10/5 440V 18/9 30/15 36/18 50/25 415V 18/9 30/15 36/18 50/25 400V 18/9 30/15 36/18 50/25 380V 18/9 30/15 36/18 50/25 240V 36/18 50/25 85/43 100/50 230V 36/18 50/25 85/43 100/50 DC 250V 10/5 20/10 30/15 30/15 GB14048.2 AC 400V 18/9 30/15 36/18 50/25 230V 36/18 50/25 85/43 100/50 Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) (TÜV) CCC certificate Electrical Appliance and Material Safety Law <PS>E* – – – – Dimensions (mm) a 105 105 105 105 140 105 105 140 105 105 140 b 165 165 165 165 c 68 68 68 68 d 95 95 95 95 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P – – – Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan c a d b Molded Case Circuit Breakers G-TWIN series Quick reference guide
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice G-TWIN Standard Series Molded Case Circuit Breakers G-TWIN series Quick reference guide Ampere frame 250A Type BW250EAG BW250JAG BW250SAG BW250RAG BW250HAG Pole 2 3 2 3 4 2 3 4 2 3 4 2 3 Rated current Reference amb. temp. (40°C) In(A) 175, 200, 225, 250 125,150,160,175 200,225,250 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 690 DC 250 250 250 250 250 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 500V 5/3 8/4 10/5 10/5 25/7 440V 18/9 30/15 36/18 50/25 65/17 415V 18/9 30/15 36/18 50/25 65/17 400V 18/9 30/15 36/18 50/25 65/17 380V 18/9 30/15 36/18 50/25 65/17 240V 36/18 50/25 85/43 100/50 125/63 230V 36/18 50/25 85/43 100/50 125/63 DC 250V 10/5 20/10 30/15 30/15 40/20 GB14048.2 AC 400V 18/9 30/15 36/18 50/25 – 230V 36/18 50/25 85/43 100/50 – Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) (TÜV) CCC certificate – Electrical Appliance and Material Safety Law <PS>E* – – – – – Dimensions (mm) a 105 105 105 105 140 105 105 140 105 105 140 105 b 165 165 165 165 165 c 68 68 68 68 68 d 95 95 95 95 95 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P – – – Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan c a d b
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice G-TWIN Standard Series Molded Case Circuit Breakers G-TWIN series Quick reference guide Ampere frame 400A Type BW400EAG BW400SAG BW400RAG BW400HAG Pole 2 3 2 3 2 3 4 2 3 4 Rated current Reference amb. temp. (40°C) In(A) 250, 300, 350, 400 Rated impulse withstand voltage Uimp(kV) 8 8 8 8 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC 250 250 250 250 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 690V − 10/5 15/8 15/8 500V 18/9 20/10 36/18 42/21 440V 30/15 36/18 50/25 70/35 415V 30/15 36/18 50/25 70/35 400V 30/15 36/18 50/25 70/35 380V 30/15 36/18 50/25 70/35 240V 50/25 85/43 100/50 125/63 230V 50/25 85/43 100/50 125/63 DC 250V 20/10 20/10 40/20 40/20 GB14048.2 AC 400V 30/15 36/18 50/25 70/35 230V 50/25 85/43 100/50 125/63 Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) (TÜV) CCC certificate Electrical Appliance and Material Safety Law <PS>E*1 − − − − Dimensions (mm) a 140 140 140 140 140 140 185 140 140 185 b 257 257 257 257 c 103 103 103 103 d 146 146 146 146 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P − − Internal accessories Page 06/65 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Flat terminal SS * Block terminal SL : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan Standard provided c a d b
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide Ampere frame 630A 800A Type BW630EAG BW630RAG BW630HAG BW800EAG BW800RAG BW800HAG Pole 3 3 4 3 4 3 3 4 3 4 Rated current Reference amb. temp. (40°C) In(A) 500, 600, 630 700, 800 Rated impulse withstand voltage Uimp(kV) 8 8 8 8 8 8 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 690 690 DC 250 250 250 250 250 250 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 690V – 15/8 15/8 – 15/8 15/8 500V 18/9 36/18 42/21 18/9 36/18 42/21 440V 36/18 50/25 70/35 36/18 50/25 70/35 415V 36/18 50/25 70/35 36/18 50/25 70/35 400V 36/18 50/25 70/35 36/18 50/25 70/35 380V 36/18 50/25 70/35 36/18 50/25 70/35 240V 50/25 100/50 125/63 50/25 100/50 125/63 230V 50/25 100/50 125/63 50/25 100/50 125/63 DC 250V 20/10 40/20 40/20 20/10 40/20 40/20 GB14048.2 AC 400V 36/18 50/25 70/35 36/18 50/25 70/35 230V 50/25 100/50 125/63 50/25 100/50 125/63 Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) (TÜV) (TÜV) (TÜV) CCC certificate Electrical Appliance and Material Safety Law <PS>E*1 – – – – – – Dimensions (mm) a 210 210 280 210 280 210 210 280 210 280 b 275 275 275 275 275 275 c 103 103 103 103 103 103 d 146 146 146 146 146 146 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P – – – – Internal accessories Page 06/65 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Flat terminal SS * Block terminal SL : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan Standard provided c a d b G-TWIN Standard Series
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide Ampere frame 50A 100A Type BW50RAGU BW100EAGU Pole 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 3, 5 10, 15, 20, 30, 32, 40, 50 3, 5 10, 15, 20, 30, 32, 40, 50 60, 63, 70, 75, 80, 90, 100 Rated impulse withstand voltage Uimp(kV) 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) AC 500V 7.5/4 7.5/4 440V 10/5 10/5 415V 10/5 10/5 400V 10/5 10/5 380V 10/5 10/5 240V 25/13 25/13 230V 25/13 25/13 GB14048.2 Icu/Ics(kA) AC 400V 7/4 10/5 7/4 10/5 10/5 230V 14/7 25/13 14/7 25/13 25/13 UL489 CAN/CSA C22.2 NO.5 (kA) AC 240V 14 – 14 Conforming to standards CE Marking (TÜV) (TÜV) CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law <PS>E*1 Dimensions (inch(mm)) a 1.969 (50) 2.953 (75) 1.969 (50) 2.953 (75) b 4.724 (120) 4.724 (120) Mass (kg) 0.5 0.6 0.5 0.6 Tripping device Hydraulic-magnetic Connecting terminal Page 06/26 Screw S Flat Block – – Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Operating handle N-type N Operating handle V-type V Terminal cover Short BT S * Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan Standard provided c a d b G-TWIN Global Series
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide Ampere frame 125A Type BW125JAGU BW125RAGU Pole 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 15, 20, 30, 40, 50, 60, 70, 75, 80, 90, 100, 125 Rated impulse withstand voltage Uimp(kV) 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 DC 250 250 Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) AC 690V – 5/3 500V 15/8 36/18 440V 30/15 50/25 415V 30/15 50/25 400V 30/15 50/25 380V 30/15 50/25 240V 50/25 100/50 230V 50/25 100/50 DC 250V 15/8 40/20 GB14048.2 Icu/Ics(kA) AC 400V 30/15 50/25 230V 50/25 100/50 UL489 CAN/CSA C22.2 NO.5 (kA) AC 600V/Y 10 10 18 480V/ – 30 50 480V/Y 30 30 50 240V 50 50 100 DC 125/250V 10 10 10 Conforming to standards CE Marking (TÜV) (TÜV) CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law <PS>E* (except for 125A) (except for 125A) Dimensions (inch(mm)) a 2.362 (60) 3.543 (90) 3.543 (90) b 6.732 (171) 6.732 (171) Mass (kg) 0.8 1.2 1.0 1.2 Tripping device Thermal-magnetic Connecting terminal Page 06/26 Screw S Flat Block Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R – Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N – Operating handle V-type V – Operating handle F-type F – Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan c a d b G-TWIN Global Series
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame 250A Type BW250EAGU BW250JAGU BW250RAGU Pole 2 3 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 125, 150, 160, 175, 200, 225, 250 Rated impulse withstand voltage Uimp(kV) 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 DC 250 250 250 Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) AC 690V – – 5/3 500V 10/5 18/9 36/18 440V 18/9 30/15 50/25 415V 18/9 30/15 50/25 400V 18/9 30/15 50/25 380V 18/9 30/15 50/25 240V 36/18 50/25 100/50 230V 36/18 50/25 100/50 DC 250V 10/5 20/10 40/20 GB14048.2 Icu/Ics(kA) AC 400V 18/9 30/15 50/25 230V 36/18 50/25 100/50 UL489 CAN/CSA C22.2 NO.5 (kA) AC 600V/Y – 10 25 480V/ – 30 50 480V/Y – 30 50 240V 22 50 100 DC 125/250V 10 10 10 Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law <PS>E* – – – Dimensions (inch(mm)) a 4.134 (105) 4.134 (105) 4.134 (105) b 7.126 (181) 7.126 (181) 7.126 (181) Tripping device Thermal-magnetic Connecting terminal Page 06/26 Screw S Flat Block Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Operating handle F-type F Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan c a d b
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame 400A Type BW400EAGU BW400SAGU BW400RAGU BW400HAGU Pole 2 3 2 3 2 3 2 3 Rated current Reference amb. temp. (40°C) In(A) 250, 300, 350, 400 Rated impulse withstand voltage Uimp(kV) 8 8 8 8 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC 250 250 250 250 Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) AC 690V − 10/5 15/8 15/8 500V 18/9 20/10 36/18 42/21 440V 30/15 36/18 50/25 70/35 415V 30/15 36/18 50/25 70/35 400V 30/15 36/18 50/25 70/35 380V 30/15 36/18 50/25 70/35 240V 50/25 85/43 100/50 125/63 230V 50/25 85/43 100/50 125/63 DC 250V 20/10 20/10 40/20 40/20 GB14048.2 Icu/Ics(kA) AC 400V 30/15 36/18 50/25 70/35 230V 50/25 85/43 100/50 125/63 UL489 CAN/CSA C22.2 NO.5 (kA) AC 600V/ − − − 25 600V/Y − − − 25 480V/ − 35 50 65 (With block terminal:50) 480V/Y − 35 50 65 (With block terminal:50) 240V 22 50 100 125 DC 125/250V 10 10 10 10 Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) (TÜV) CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law <PS>E* − − − − Dimensions (inch(mm)) a 5.512 (140) 5.512 (140) 5.512 (140) 5.512 (140) b 10.12 (257) 10.12 (257) 10.12 (257) 10.12 (257) c 4.055 (103) 4.055 (103) 4.055 (103) 4.055 (103) d 5.748 (146) 5.748 (146) 5.748 (146) 5.748 (146) Tripping device Thermal-magnetic Connecting terminal Page 06/26 Flat Block Internal accessories Page 06/65 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Operating handle F-type F Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 : Approved : Available –: Not available Note: * Electrical Appliance and Material Safety Law of Japan c a d b
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame 630A 800A Type BW630RAGU BW630HAGU BW800RAGU BW800HAGU Pole 3 3 3 3 Rated current Reference amb. temp. (40°C) In(A) 500, 600, 630* 700, 800* Rated impulse withstand voltage Uimp(kV) 8 8 8 8 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC 250 250 250 250 Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) AC 690V 15/8 15/8 15/8 15/8 500V 36/18 42/21 36/18 42/21 440V 50/25 70/35 50/25 70/35 415V 50/25 70/35 50/25 70/35 400V 50/25 70/35 50/25 70/35 380V 50/25 70/35 50/25 70/35 240V 100/50 125/63 100/50 125/63 230V 100/50 125/63 100/50 125/63 DC 250V 40/20 40/20 40/20 40/20 GB14048.2 Icu/Ics(kA) AC 400V 50/25 70/35 50/25 70/35 230V 100/50 125/63 100/50 125/63 UL489 CAN/CSA C22.2 NO.5 (kA) AC 600V/ − 25 − 25 600V/Y − 25 − 25 480V/ 50 65 (With block terminal:50) 50 65 (With block terminal:50) 480V/Y − 65 (With block terminal:50) 50 65 (With block terminal:50) 240V 100 125 100 125 DC 125/250V 10 10 10 10 Conforming to standards CE Marking (TÜV) (TÜV) (TÜV) (TÜV) CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law <PS>E* − − − − Dimensions (inch(mm)) a 8.268 (210) 8.268 (210) 8.268 (210) 8.268 (210) b 10.83 (275) 10.83 (275) 10.83 (275) 10.83 (275) c 4.055 (103) 4.055 (103) 4.055 (103) 4.055 (103) d 5.748 (146) 5.748 (146) 5.748 (146) 5.748 (146) Mass (kg) 8.9 8.9 9.4 9.4 Tripping device Thermal-magnetic Connecting terminal Page 06/26 Flat Block Internal accessories Page 06/65 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover BT L Insulation barrier Interphase BP Handle locking cover L1 : Approved : Available –: Not available Note: * Breakers for 630A cannot be manufactured with block terminals. Block terminals are standard for Breakers for 800A. Electrical Appliance and Material Safety Law of Japan c a d b
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/18 Molded Case Circuit Breakers G-TWIN series Quick reference guide n G-TWIN Standard Series / Motor protection Ampere frame 32A Type BW32AAM BW32SAM Pole 3 2 3 24, 32 Rated impulse withstand voltage Uimp(kV) 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 690 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 690V – – – 500V – 1.5/1 1.5/1 240V 2.5/2 5/3 5/3 230V 2.5/2 5/3 5/3 GB14048.2 AC 400V 1.5/1 2.5/2 2.5/2 230V 2.5/2 5/3 5/3 Conforming to standards CE Marking CCC certificate Electrical Appliance and Material Safety Law <PS>E* Dimensions (mm) c a d b a 75 50 75 b 100 100 100 c 60 60 60 d 84 84 84 Mass (kg) 0.5 0.4 0.5 Tripping device Hydraulic-magnetic Hydraulic-magnetic Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Insulation barrier Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL – – – : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circuit breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan Motor protection breakers Motors are normally controlled by MCCBs and magnetic starters. In this case the MCCB carries out overcurrent or short-circuit current protection while the starter deals with ON-OFF switching of the motor and offers protection against sustained overload currents. These are the motor breakers which combine the two functions. FUJI motor breakers are designed to eliminate erroneous operations due to the rush current produced at the time of starting the motor. They will trip in the face of sustained overcurrent when the integrated bimetal relay has operated.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide n G-TWIN Standard Series / Motor protection Ampere frame 50A Type BW50EAM BW50SAM BW50RAM Pole 3 3 3 24, 32, 40, 45 10, 12, 16, 24, 32, 40, 45 Rated impulse withstand voltage Uimp(kV) 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 690 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 690V – – – 500V 1.5/1 5/3 7.5/4 440V 2.5/2 7.5/4 10/5 415V 2.5/2 7.5/4 10/5 400V 2.5/2 7.5/4 10/5 380V 2.5/2 7.5/4 10/5 240V 5/3 10/5 25/13 230V 5/3 10/5 25/13 GB14048.2 AC 400V 2.5/2 7.5/4 10/5 230V 5/3 10/5 25/13 Conforming to standards CE Marking CCC certificate Electrical Appliance and Material Safety Law <PS>E* Dimensions (mm) c a d b a 75 75 75 b 100 100 100 c 60 60 60 d 84 84 84 Mass (kg) 0.5 0.5 0.5 Tripping device Hydraulic-magnetic Hydraulic-magnetic Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Insulation barrier Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL – – – : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circuit breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/20 Molded Case Circuit Breakers G-TWIN series Quick reference guide n G-TWIN Standard Series / Motor protection Ampere frame 63A 100A Type BW63EAM BW63SAM BW100EAM Pole 3 3 3 Rated current Reference amb. temp. (40°C) In(A) 63 63 63, 75, 90 Rated impulse withstand voltage Uimp(kV) 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 AC 690V – – – 500V 1.5/1 5/3 7.5/4 440V 2.5/2 7.5/4 10/5 415V 2.5/2 7.5/4 10/5 400V 2.5/2 7.5/4 10/5 380V 2.5/2 7.5/4 10/5 240V 5/3 10/5 25/13 230V 5/3 10/5 25/13 GB14048.2 AC 400V 2.5/2 7.5/4 10/5 230V 5/3 10/5 25/13 Conforming to standards CE Marking CCC certificate Electrical Appliance and Material Safety Law <PS>E* Dimensions (mm) c a d b a 75 75 75 b 100 100 100 c 60 60 60 d 84 84 84 Mass (kg) 0.6 0.6 0.6 Tripping device Hydraulic-magnetic Hydraulic-magnetic Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Insulation barrier Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circuit breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide n G-TWIN Standard Series / Motor protection Ampere frame 125A 250A Type BW125JAM BW125RAM BW250EAM BW250JAM BW250RAM Pole 3 3 3 3 3 Rated current Reference amb. temp. (40°C) In(A) 16, 24, 32, 40, 45, 60, 75, 90 125, 150, 175, 225 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 690 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 500V 8/4 10/5 5/3 8/4 10/5 440V 30/15 50/25 18/9 30/15 50/25 415V 30/15 50/25 18/9 30/15 50/25 400V 30/15 50/25 18/9 30/15 50/25 380V 30/15 50/25 18/9 30/15 50/25 240V 50/25 100/50 36/18 50/25 100/50 230V 50/25 100/50 36/18 50/25 100/50 GB14048.2 AC 400V 30/15 50/25 18/9 30/15 50/25 230V 50/25 100/50 36/18 50/25 100/50 Conforming to standards CE Marking CCC certificate Electrical Appliance and Material Safety Law <PS>E* – – – Dimensions (mm) c a d b a 90 90 105 105 105 b 155 155 165 165 165 c 68 68 68 68 68 d 95 95 95 95 95 Tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available –: Not available : Factory-mounted accessory Note: * Specify DC only when ordering circuit breakers for DC circuit. Electrical Appliance and Material Safety Law of Japan
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/22 Molded Case Circuit Breakers G-TWIN series Mounting modifications n Mounting modifications
- Standard series Standard type FUJI breakers are front mounting with front connections. The standard breaker can easily be modified to become front mounting rear connection type, flush mounting type and plug-in type. The additional parts such as insulation bases, barriers, covers and similar parts are added as required. Front mounting Front connection Additional main parts Bar stud terminal Additional main parts Bar stud terminal Front mounting Rear connection (X type) Flush mounting Rear connection (E type) Additional main parts Plug-in mounting (P type) Additional main parts Flush mounting Top and bottom connection (Y type) BW32 BW50 BW63 BW100 BW32 BW50 BW63 BW100 Round stud terminal BW32 BW50 BW63 BW100 BW50HAG BW125 Each stud can be turned by 90° Each stud can be turned by 90° Each stud can be turned by 90° Bar stud terminal Bar stud terminal BW50HAG BW125 BW160 BW250 BW400 BW630 BW800 BW50HAG BW125 BW160 BW250 BW400 BW630 BW800 Bar stud terminal Bar stud terminal BW32 BW50 BW63 BW100 BW160 BW250 BW400 BW630 BW800 Decorative flush plate BASIC DESIGN
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice
- Global series Screw Flat terminal Block terminal BASIC DESIGN Front mounting Front connection Molded Case Circuit Breakers G-TWIN series Mounting modifications
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/24 Molded Case Circuit Breakers G-TWIN series Terminal connection n Terminal connection/Front mounting, front connection Front Front Flat terminal Breaker type Size (mm) M12 35 M12 40 M8 16 M8 16 Hexagonal head bolt BW400 BW630 BW800 Tightening torque (N•m) Tightening torque (N•m) 40 to 50 40 to 50 Type of connection/up to 250AF Front mounting front connection Direct connection Flat terminal connection Flat terminals are required. Pan-head screw Hexagonal socket head bolt Breaker type Flat bar studs/1-hole type BW50HAG BW125 BW160 BW250 Tightening torque (N•m) 5.5 to 7.5 8.0 to 13.0 Size (mm) Flat terminal Breaker type Pole Type of flat terminal BW50HAG BW125 BW160 BW250 BW9SS0CA-2 BW9SS0CA-3 BW9SS0CA-4 BZ-S50B-2252 BZ-S50B-2253 BW9SS0GA-4 BW32 BW50 BW63 BW100* BZ6S10C502 BZ6S10C503 BZ6S10C1002 BZ6S10C1003 Front Flat terminal Self lifting screw Pan-head screw Breaker type BW32 BW50 BW100* 2.3 to 2.8 Size M5 14 M8 15 BW63 BW100 5.5 to 7.5 * BW100 breaker of rated current 50A: BZ6S10C502 or 503. * Breaker of rated current : 50A
- 32AF to 100AF • 400AF to 800AF
- 125AF to 250AF
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Wire size and terminal n Breaker termination n Wire size and crimp terminal The following is the siz e recommendations for crimp terminals. Crimp terminal R : JIS C2805 CB : JEM-1399 JST : Product of Japan Crimp T erminal Co., Ltd. Ampere frame Breaker Wire size(mm 1.04 2.63 2.63 6.64 6.64 10.52 10.52 16.78 16.78 26.66 26.66 42.42 42.42 60.57 96.3 117.2 117.2 152.05 192.6 242.27 242.27 325 32 BW32 R2-5 R5.5-5 R8-5 R14-5 50 BW50AAG,EAG,SAG R2-5 R5.5-5 R8-5 R14-5 BW50HAG R2-8 R5.5-8 R8-8 R14-8 R22-8 JST38-S8 CB60-8 63 BW63 R2-8 R5.5-8 R8-8 R14-8 JST22-S8 100 BW100 R2-8 R5.5-8 R8-8 R14-8 JST22-S8 JST38-S8 125 BW125 R2-8 R5.5-8 R8-8 R14-8 R22-8 JST38-S8 CB60-8 160 250 BW160 BW250 R22-8 R38-8 R60-8 CB100-8
400 BW400 R38-12 R60-12 R100-12 R150-12 R200-12
630 BW630 R100-12 R150-12 R200-12 JST325-12
800 BW800 R100-12 R150-12 R200-12 JST325-12
- Standard BW32 BW50 BW63 BW100 Self-lifiting terminal MCCB type Front connection BW50HAG BW125 BW160 BW250 BW400 BW630 BW800 Rear connection X Flush mounting E Y Plug-in mounting P Flat terminal Flat terminal Flat terminal 90˚ rotational stud 90˚ rotational stud 90˚ rotational stud
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/26 Terminal position Applicable breaker type Code Blank Blank SB SF Line Screw Flat teminal Block terminal Flat teminal Screw Flat teminal Screw Block terminal Flat teminal Block terminal Load Screw Flat teminal Block terminal Flat teminal Flat terminal Screw Block terminal Screw Block terminal Flat terminal BW100, 125, 250 BW50 BW400, 630, 800 Molded Case Circuit Breakers G-TWIN series Wire size and terminal n Notes on wiring (global series) Notes on connecting wires (conductors)
- Connect wires to the UL breaker according to NEC (National Electric Code) or CEC (Canadian Electr ical Code) Part 1.
- Use 75°C copper wires for wiring. UL-certified or CSA- certified wires are recommended.
- If a large current (for example, a short-circuit current) flows, it causes a huge electromagnetic force between wires. Therefore, be sure to secure the wires sufficiently.
- Re-tighten terminal screws periodically. Block terminal connection
- Choose from the stranded wires shown in Table. Wire size: AWG or MCM [mm ] No. of wires stranded 14 to 2 [2.1 to 33.6] 7 1 to 4/0 [42.4 to 107.2] 19 250 to 500 [127 to 250] 37 Values in [ ] are those converted from AWG or MCM sizes to mm * See the instruction manual that comes with the breaker for more details. Precautions
- Two wires of different sizes cannot be connected to the same block terminal.
- Be sure to use stranded wires according to Table "Number of wires stranded."
- Multi-conductor wires cannot be connected.
- Do not solder wires together. Wire size and crimp terminal
- Crimp terminal connection MCCB Rated current (A) Applicable crimp terminal 75˚C wire Connectable wire size (AWG) Tightening torque (N•m) Type of screw head and size (mm) Mfg. Co., Ltd. 75˚C wire BW50RAGU 3 R2-5 R2-5M R2-5 Cross/straight slotted pan-head screw M5 x 14 R5.5-5S, R5.5-5 3.5-5, 5.5-S5, 5.5-5, 5.5-L5 12AWG 30 10AWG
40 R8-5 R8-5S, R8-5 8-S5, 8-5 8AWG
BW100EAGU 60 R14-8 R14-8S, R14-8 R14-S8, R14-8 6AWG 5.5-7.5 Cross/straight slotted pan-head screw M8 x 15 75 22-S8 R22-8S, R22-8 R22-S8, 22-8 4AWG 100 38-S8 R38-8S 38-S8 3AWG BW125JAGU BW125RAGU 15 R2-8 R2-8 2-8, 2-B8 14AWG 5.8 (5.3-6.4) Cross/straight slotted pan-head screw M8 x 16 30 R5.5-8 5.5-8 10AWG 40 8-8NS, R8-8 R8-8 8-8 8AWG 60 14-8NS, 14-S8, R14-8 R14-8S, R14-8 14-S8, 14-8 6AWG 70 22-S8, R22-8, CB22-S8 R22-8S, R22-8, CB22-8S 22-S8, 22-8, CB22-8 4AWG 90 38-S8 R38-8S 38-S8 3AWG 100 125 1AWG BW250EAGU BW250JAGU BW250RAGU 125 38-S8, R38-8 R38-8S, R38-8 38-S8, 38-8 1AWG 10.5 (8-13) Hexagon socket head bolt M8 x 16 150 60-S8, R60-8 R60-8, CB60-8, CB60-8S 60-8, CB60-8 1/0AWG 175 70-8 R70-8 70-8 2/0AWG
200 CB80-S8 CB80-8 3/0AWG
225 CB100-S8 CB100-8 4/0AWG
250 CB150-S8 CB150-8 CB150-8 250MCM
Notes: • AWG/MCM is the UL approved wire unit.
- The allowable temperature of wire is 75˚C. (UL CSA approved)
- Be sure to use UL-certified or CSA-certified crimp tools commercially available.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Wire size and terminal
- Flat terminal connection MCCB Rated current (A) Applicable crimp terminal 75˚C wire Connectable wire size (AWG) Tightening torque (N•m) Type of screw head and size (mm) Terminal Mfg. Co., Ltd. 75˚C wire Wire side MCCB side BW50RAGU 3 R2-5 R2-5M R2-5 2-S5, 2-5 14AWG 3.5 to 4.5 2.3 to 2.8 Hexagon socket head bolt M5 x 16 R5.5-5S, R5.5-5 3.5-5, 5.5-S5 5.5-5, 5.5-L5 12AWG 30 10AWG
BW100EAGU 60 R14-8 R14-8S, R14-8 R14-S8, R14-8 6AWG 8 to 10 5.5 to 7.5 Hexagon socket head bolt M8 x 22 75 22-S8 R22-8S, R22-8 R22-S8, 22-8 4AWG 100 38-S8 R38-8S 38-S8 3AWG BW125JAGU BW125RAGU
15 R2-8 R2-8 2-8, 2-B8 14AWG 9
(8 to 10) 5.8 (5.3 to 6.4) Cross/straight slotted pan-head screw M8 x 16 30 R5.5-8 5.5-8 10AWG 40 8-8NS, R8-8 R8-8 8-8 8AWG 60 14-8NS, 14-S8, R14-8 R14-8S, R14-8 14-S8, 14-8 6AWG 70 22-S8, R22-8, CB22-S8 R22-8S, R22-8, CB22-8S 22-S8, 22-8, CB22-8 4AWG 90 38-S8 R38-8S 38-S8 3AWG 100 125 1AWG BW250EAGU BW250JAGU BW250RAGU 125 38-S8, R38-8 R38-8S, R38-8 38-S8, 38-8 1AWG 9 (8 to 10) 10.5 (8 to 13) Hexagon socket head bolt M8 x 16 150 60-S8, R60-8 R60-8, CB60-8, CB60-8S 60-8, CB60-8 1/0AWG 175 70-8 R70-8 70-8 2/0AWG 250 150-12 R150-12 250MCM 45 (40 to 50) 43.5 (39.2 to 48) Hexagon head bolt M12 x 35 300 180-12 R180-12 350MCM 350 325-12 R325-12N 500MCM 400 325-12 R325-12N 500MCM R80-12 R80-12 3/0AWG(x2) BW630RAGU BW630HAGU 500 R150-12 R150-12 250MCM(x2) 47.04 (42.4 to 51.7) 47.04 (42.4 to 51.7) Hexagon head bolt M12 x 40 600 180-12 R180-12 350MCM(x2) 630 325-12 R325-12N R325-12 500MCM(x2) BW800RAGU BW800HAGU 700 325-12 R325-12 500MCM(x2) 47.04 (42.4 to 51.7) 47.04 (42.4 to 51.7) Hexagon head bolt M12 x 40 Notes: • AWG/MCM is the UL approved wire unit.
- The allowable temperature of wire is 75˚C. (UL CSA approved)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/28 Molded Case Circuit Breakers G-TWIN series Wire size and terminal
- Block terminal connection MCCB Rated current (A) Connectable wire size (AWG) Tightening torque (N•m) Type of screw head and size (mm) Figure BW100EAGU 60 6AWG 5.8 (5.5 to 6.5) Slotted set screw 70 4AWG 90 3AWG 100 BW125JAGU BW125RAGU 15 14AWG 5.8 (5.8 to 6.4) Slotted set screw 20 12AWG 30 10AWG 40 8AWG 60 6AWG 70 4AWG 90 3AWG 100 125 1AWG BW250EAGU BW250JAGU BW250RAGU 125 1AWG 23 (23 to 25.3) Hexagon socket head setscrew: 8 mm (5/16 inch) Screw head size 150 1/0AWG 175 2/0AWG 200 3/0AWG 225 4/0AWG 250 250MCM BW400EAGU BW400SAGU BW400RAGU BW400HAGU 250 250MCM 43.5 (43.5 to 48) Hexagon socket head setscrew: 9.53 mm (3/8 inch) 300 350MCM 350 500MCM 400 3/0AWG(x2) 31.9 (31.9 to 35.1) Hexagon socket head setscrew: 8 mm (5/16 inch) BW630RAGU BW630HAGU 500 250MCM(x2) 31.1 (31.1 to 34.2) Hexagon socket head setscrew: 8 mm (5/16 inch) 600 350MCM(x2) BW800RAGU BW800HAGU 700 500MCM(x2) 31.1 (31.1 to 34.2) Hexagon socket head setscrew: 8 mm (5/16 inch) 800 300MCM(x3) Notes: • AWG/MCM is the UL approved wire unit.
- The allowable temperature of wire is 75˚C. (UL CSA approved)
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series l AAG series, 2-pole IEC/EN/GB/JIS conformed l EAG series, 2-pole IEC/EN/GB/JIS conformed l JAG series, 2-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection 32 3 BW32AAG-2P003 Blank, X, E, Y , P
5 BW32AAG-2P005
10 BW32AAG-2P010
15 BW32AAG-2P015
20 BW32AAG-2P020
30 BW32AAG-2P030
32 BW32AAG-2P032
50 5 BW50AAG-2P005 Blank, X, E, Y , P
10 BW50AAG-2P010
15 BW50AAG-2P015
20 BW50AAG-2P020
30 BW50AAG-2P030
32 BW50AAG-2P032
40 BW50AAG-2P040
50 BW50AAG-2P050
(A) Type : Available mounting and connection 50 5 BW50EAG-2P005 Blank, X, E, Y , P
10 BW50EAG-2P010
15 BW50EAG-2P015
20 BW50EAG-2P020
30 BW50EAG-2P030
32 BW50EAG-2P032
40 BW50EAG-2P040
50 BW50EAG-2P050
63 60 BW63EAG-2P060 Blank, X, E, Y , P
63 BW63EAG-2P063
100 50 BW100EAG-2P050 Blank, X, E, Y , P
60 BW100EAG-2P060
63 BW100EAG-2P063
75 BW100EAG-2P075
100 BW100EAG-2P100
160 125 BW160EAG-2P125 Blank, X, E, P
150 BW160EAG-2P150
160 BW160EAG-2P160
250 175 BW250EAG-2P175 Blank, X, E, P
200 BW250EAG-2P200
225 BW250EAG-2P225
250 BW250EAG-2P250
400 250 BW400EAG-2P250 Blank, X, E, P
300 BW400EAG-2P300
350 BW400EAG-2P350
400 BW400EAG-2P400
(A) Type : Available mounting and connection 125 15 BW125JAG-2P015 Blank, X, E, P
20 BW125JAG-2P020
30 BW125JAG-2P030
40 BW125JAG-2P040
50 BW125JAG-2P050
60 BW125JAG-2P060
75 BW125JAG-2P075
100 BW125JAG-2P100
125 BW125JAG-2P125
160 125 BW160JAG-2P125 Blank, X, E, P
150 BW160JAG-2P150
160 BW160JAG-2P160
250 175 BW250JAG-2P175 Blank, X, E, P
200 BW250JAG-2P200
225 BW250JAG-2P225
250 BW250JAG-2P250
X E Flush Top and buttom Y Plug-in P n Type number, Standard series (Line protection) Type number/Line protection
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series l HAG series, 2-pole IEC/EN/JIS conformed l HAG series, 2-pole IEC/EN/GB/JIS conformed l SAG series, 2-pole IEC/EN/GB/JIS conformed l RAG series, 2-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 32 3 BW32SAG-2P003 Blank, X, E, Y , P
5 BW32SAG-2P005
10 BW32SAG-2P010
15 BW32SAG-2P015
20 BW32SAG-2P020
30 BW32SAG-2P030
32 BW32SAG-2P032
50 5 BW50SAG-2P005 Blank, X, E, Y , P
10 BW50SAG-2P010
15 BW50SAG-2P015
20 BW50SAG-2P020
30 BW50SAG-2P030
32 BW50SAG-2P032
40 BW50SAG-2P040
50 BW50SAG-2P050
63 60 BW63SAG-2P060 Blank, X, E, Y , P
63 BW63SAG-2P063
125 15 BW125SAG-2P015 Blank, X, E, P
20 BW125SAG-2P020
30 BW125SAG-2P030
40 BW125SAG-2P040
50 BW125SAG-2P050
60 BW125SAG-2P060
75 BW125SAG-2P075
100 BW125SAG-2P100
125 BW125SAG-2P125
160 125 BW160SAG-2P125 Blank, X, E, P
150 BW160SAG-2P150
160 BW160SAG-2P160
250 175 BW250SAG-2P175 Blank, X, E, P
200 BW250SAG-2P200
225 BW250SAG-2P225
250 BW250SAG-2P250
400 250 BW400SAG-2P250 Blank, X, E, P
300 BW400SAG-2P300
350 BW400SAG-2P350
400 BW400SAG-2P400
(A) Type : Available mounting and connection* 50 10 BW50RAG-2P010 Blank, X, E, Y , P
15 BW50RAG-2P015
20 BW50RAG-2P020
30 BW50RAG-2P030
32 BW50RAG-2P032
40 BW50RAG-2P040
50 BW50RAG-2P050
63 60 BW63RAG-2P060 Blank, X, E, Y , P
63 BW63RAG-2P063
125 15 BW125RAG-2P015 Blank, X, E, P
20 BW125RAG-2P020
30 BW125RAG-2P030
40 BW125RAG-2P040
50 BW125RAG-2P050
60 BW125RAG-2P060
75 BW125RAG-2P075
100 BW125RAG-2P100
125 BW125RAG-2P125
160 125 BW160RAG-2P125 Blank, X, E, P
150 BW160RAG-2P150
160 BW160RAG-2P160
250 175 BW250RAG-2P175 Blank, X, E, P
200 BW250RAG-2P200
225 BW250RAG-2P225
250 BW250RAG-2P250
400 250 BW400RAG-2P250 Blank, X, E, P
300 BW400RAG-2P300
350 BW400RAG-2P350
400 BW400RAG-2P400
(A) Type : Available mounting and connection* 50 15 BW50HAG-2P015 Blank, X, E, P
20 BW50HAG-2P020
30 BW50HAG-2P030
40 BW50HAG-2P040
50 BW50HAG-2P050
125 15 BW125HAG-2P015 Blank, X, E, P
20 BW125HAG-2P020
30 BW125HAG-2P030
40 BW125HAG-2P040
50 BW125HAG-2P050
60 BW125HAG-2P060
75 BW125HAG-2P075
100 BW125HAG-2P100
125 BW125HAG-2P125
250 125 BW250HAG-2P125 Blank, X, E, P
150 BW250HAG-2P150
160 BW250HAG-2P160
175 BW250HAG-2P175
200 BW250HAG-2P200
225 BW250HAG-2P225
250 BW250HAG-2P250
(A) Type : Available mounting and connection* 400 250 BW400HAG-2P250 Blank, X, E, P
300 BW400HAG-2P300
350 BW400HAG-2P350
400 BW400HAG-2P400
- See page 06/29. Type number/Line protection
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series l AAG series, 3-pole IEC/EN/GB/JIS conformed l EAG series, 3-pole IEC/EN/GB/JIS conformed l JAG series, 3-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 32 3 BW32AAG-3P003 Blank, X, E, Y , P
5 BW32AAG-3P005
10 BW32AAG-3P010
15 BW32AAG-3P015
20 BW32AAG-3P020
30 BW32AAG-3P030
32 BW32AAG-3P032
50 5 BW50AAG-3P005 Blank, X, E, Y , P
10 BW50AAG-3P010
15 BW50AAG-3P015
20 BW50AAG-3P020
30 BW50AAG-3P030
32 BW50AAG-3P032
40 BW50AAG-3P040
50 BW50AAG-3P050
100 60 BW100AAG-3P060 Blank, X, E, Y , P
63 BW100AAG-3P063
75 BW100AAG-3P075
100 BW100AAG-3P100
(A) Type : Available mounting and connection* 50 5 BW50EAG-3P005 Blank, X, E, Y , P
10 BW50EAG-3P010
15 BW50EAG-3P015
20 BW50EAG-3P020
30 BW50EAG-3P030
32 BW50EAG-3P032
40 BW50EAG-3P040
50 BW50EAG-3P050
63 60 BW63EAG-3P060 Blank, X, E, Y , P
63 BW63EAG-3P063
100 50 BW100EAG-3P050 Blank, X, E, Y , P
60 BW100EAG-3P060
63 BW100EAG-3P063
75 BW100EAG-3P075
100 BW100EAG-3P100
160 125 BW160EAG-3P125 Blank, X, E, P
150 BW160EAG-3P150
160 BW160EAG-3P160
250 175 BW250EAG-3P175 Blank, X, E, P
200 BW250EAG-3P200
225 BW250EAG-3P225
250 BW250EAG-3P250
400 250 BW400EAG-3P250 Blank, X, E, P
300 BW400EAG-3P300
350 BW400EAG-3P350
400 BW400EAG-3P400
630 500 BW630EAG-3P500 Blank, X, E, P
600 BW630EAG-3P600
630 BW630EAG-3P630
800 700 BW800EAG-3P700 Blank, X, E, P
800 BW800EAG-3P800
(A) Type : Available mounting and connection* 125 15 BW125JAG-3P015 Blank, X, E, P
20 BW125JAG-3P020
30 BW125JAG-3P030
40 BW125JAG-3P040
50 BW125JAG-3P050
60 BW125JAG-3P060
75 BW125JAG-3P075
100 BW125JAG-3P100
125 BW125JAG-3P125
160 125 BW160JAG-3P125 Blank, X, E, P
150 BW160JAG-3P150
160 BW160JAG-3P160
250 175 BW250JAG-3P175 Blank, X, E, P
200 BW250JAG-3P200
225 BW250JAG-3P225
250 BW250JAG-3P250
- See page 06/29. Type number/Line protection
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series l HAG series, 3-pole IEC/EN/GB/JIS conformed l SAG series, 3-pole IEC/EN/GB/JIS conformed l RAG series, 3-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 32 3 BW32SAG-3P003 Blank, X, E, Y , P
5 BW32SAG-3P005
10 BW32SAG-3P010
15 BW32SAG-3P015
20 BW32SAG-3P020
30 BW32SAG-3P030
32 BW32SAG-3P032
50 5 BW50SAG-3P005 Blank, X, E, Y , P
10 BW50SAG-3P010
15 BW50SAG-3P015
20 BW50SAG-3P020
30 BW50SAG-3P030
32 BW50SAG-3P032
40 BW50SAG-3P040
50 BW50SAG-3P050
63 60 BW63SAG-3P060 Blank, X, E, Y , P
63 BW63SAG-3P063
125 15 BW125SAG-3P015 Blank, X, E, P
20 BW125SAG-3P020
30 BW125SAG-3P030
40 BW125SAG-3P040
50 BW125SAG-3P050
60 BW125SAG-3P060
75 BW125SAG-3P075
100 BW125SAG-3P100
125 BW125SAG-3P125
160 125 BW160SAG-3P125 Blank, X, E, P
150 BW160SAG-3P150
160 BW160SAG-3P160
250 175 BW250SAG-3P175 Blank, X, E, P
200 BW250SAG-3P200
225 BW250SAG-3P225
250 BW250SAG-3P250
400 250 BW400SAG-3P250 Blank, X, E, P
300 BW400SAG-3P300
350 BW400SAG-3P350
400 BW400SAG-3P400
(A) Type : Available mounting and connection* 50 10 BW50RAG-3P010 Blank, X, E, Y , P
15 BW50RAG-3P015
20 BW50RAG-3P020
30 BW50RAG-3P030
32 BW50RAG-3P032
40 BW50RAG-3P040
50 BW50RAG-3P050
63 60 BW63RAG-3P060 Blank, X, E, Y , P
63 BW63RAG-3P063
125 15 BW125RAG-3P015 Blank, X, E, P
20 BW125RAG-3P020
30 BW125RAG-3P030
40 BW125RAG-3P040
50 BW125RAG-3P050
60 BW125RAG-3P060
75 BW125RAG-3P075
100 BW125RAG-3P100
125 BW125RAG-3P125
160 125 BW160RAG-3P125 Blank, X, E, P
150 BW160RAG-3P150
160 BW160RAG-3P160
250 175 BW250RAG-3P175 Blank, X, E, P
200 BW250RAG-3P200
225 BW250RAG-3P225
250 BW250RAG-3P250
400 250 BW400RAG-3P250 Blank, X, E, P
300 BW400RAG-3P300
350 BW400RAG-3P350
400 BW400RAG-3P400
630 500 BW630RAG-3P500 Blank, X, E, P
600 BW630RAG-3P600
630 BW630RAG-3P630
800 700 BW800RAG-3P700 Blank, X, E, P
800 BW800RAG-3P800
(A) Type : Available mounting and connection* 400 250 BW400HAG-3P250 Blank, X, E, P
300 BW400HAG-3P300
350 BW400HAG-3P350
400 BW400HAG-3P400
630 500 BW630HAG-3P500 Blank, X, E, P
600 BW630HAG-3P600
630 BW630HAG-3P630
800 700 BW800HAG-3P700 Blank, X, E, P
800 BW800HAG-3P800
- See page 06/29. Type number/Line protection
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series l JAG series, 4-pole IEC/EN/GB/JIS conformed l HAG series, 4-pole IEC/EN/GB/JIS conformed l SAG series, 4-pole IEC/EN/GB/JIS conformed l RAG series, 4-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 125 15 BW125JAG-4P015 Blank, X, E
20 BW125JAG-4P020
30 BW125JAG-4P030
40 BW125JAG-4P040
50 BW125JAG-4P050
60 BW125JAG-4P060
75 BW125JAG-4P075
100 BW125JAG-4P100
125 BW125JAG-4P125
160 125 BW160JAG-4P125 Blank, X, E
150 BW160JAG-4P150
160 BW160JAG-4P160
250 175 BW250JAG-4P175 Blank, X, E
200 BW250JAG-4P200
225 BW250JAG-4P225
250 BW250JAG-4P250
(A) Type : Available mounting and connection* 125 15 BW125SAG-3P015 Blank, X, E 160 125 BW160SAG-3P125 Blank, X, E 250 175 BW250SAG-3P175 Blank, X, E (A) Type : Available mounting and connection* 125 15 BW125RAG-4P015 Blank, X, E
20 BW125RAG-4P020
30 BW125RAG-4P030
40 BW125RAG-4P040
50 BW125RAG-4P050
60 BW125RAG-4P060
75 BW125RAG-4P075
100 BW125RAG-4P100
125 BW125RAG-4P125
160 125 BW160RAG-4P125 Blank, X, E
150 BW160RAG-4P150
160 BW160RAG-4P160
250 175 BW250RAG-4P175 Blank, X, E
200 BW250RAG-4P200
225 BW250RAG-4P225
250 BW250RAG-4P250
400 250 BW400RAG-4P250 Blank, X, E
300 BW400RAG-4P300
350 BW400RAG-4P350
400 BW400RAG-4P400
630 500 BW630RAG-4P500 Blank, X, E
600 BW630RAG-4P600
630 BW630RAG-4P630
800 700 BW800RAG-4P700 Blank, X, E
800 BW800RAG-4P800
(A) Type : Available mounting and connection* 400 250 BW400HAG-4P250 Blank, X, E
300 BW400HAG-4P300
350 BW400HAG-4P350
400 BW400HAG-4P400
630 500 BW630HAG-4P500 Blank, X, E
600 BW630HAG-4P600
630 BW630HAG-4P630
800 700 BW800HAG-4P700 Blank, X, E
800 BW800HAG-4P800
- See page 06/29. Type number/Line protection
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Line protection l EAGU series, 2-pole UL489 Listed l JAGU series, 2-pole UL489 Listed l SAGU series, 2-pole UL489 Listed l RAGU series, 2-pole UL489 Listed Breaker ampere frame Rated current (A) Type : Available mounting and connection 100 60 BW100EAGU-2P060 Blank, SB, SF , S3
63 BW100EAGU-2P063 S4, S5, S6, S7, S8
70 BW100EAGU-2P070
75 BW100EAGU-2P075
80 BW100EAGU-2P080
90 BW100EAGU-2P090
100 BW100EAGU-2P100
250 125 BW250EAGU-2P125 Blank, SB, SF , S3
150 BW250EAGU-2P150 S4, S5, S6, S7, S8
160 BW250EAGU-2P160
175 BW250EAGU-2P175
200 BW250EAGU-2P200
225 BW250EAGU-2P225
250 BW250EAGU-2P250
400 250 BW400EAGU-2P250 Blank, SB, S7, S8
300 BW400EAGU-2P300
350 BW400EAGU-2P350
400 BW400EAGU-2P400
(A) Type : Available mounting and connection 125 15 BW125JAGU-2P015 Blank, SB, SF , S3
20 BW125JAGU-2P020 S4, S5, S6, S7, S8
30 BW125JAGU-2P030
40 BW125JAGU-2P040
50 BW125JAGU-2P050
60 BW125JAGU-2P060
70 BW125JAGU-2P070
75 BW125JAGU-2P075
80 BW125JAGU-2P080
90 BW125JAGU-2P090
100 BW125JAGU-2P100
125 BW125JAGU-2P125
250 125 BW250JAGU-2P125 Blank, SB, SF , S3
150 BW250JAGU-2P150 S4, S5, S6, S7, S8
160 BW250JAGU-2P160
175 BW250JAGU-2P175
200 BW250JAGU-2P200
225 BW250JAGU-2P225
250 BW250JAGU-2P250
(A) Type : Available mounting and connection 400 250 BW400SAGU-2P250 Blank, SB, S7, S8
300 BW400SAGU-2P300
350 BW400SAGU-2P350
400 BW400SAGU-2P400
(A) Type : Available mounting and connection 50 3 BW50RAGU-2P003 Blank, SF , S3, S4
5 BW50RAGU-2P005
10 BW50RAGU-2P010
15 BW50RAGU-2P015
20 BW50RAGU-2P020
30 BW50RAGU-2P030
32 BW50RAGU-2P032
40 BW50RAGU-2P040
50 BW50RAGU-2P050
125 15 BW125RAGU-2P015 Blank, SB, SF , S3
20 BW125RAGU-2P020 S4, S5, S6, S7, S8
30 BW125RAGU-2P030
40 BW125RAGU-2P040
50 BW125RAGU-2P050
60 BW125RAGU-2P060
70 BW125RAGU-2P070
75 BW125RAGU-2P075
80 BW125RAGU-2P080
90 BW125RAGU-2P090
100 BW125RAGU-2P100
125 BW125RAGU-2P125
250 125 BW250RAGU-2P125 Blank, SB, SF , S3
150 BW250RAGU-2P150 S4, S5, S6, S7, S8
160 BW250RAGU-2P160
175 BW250RAGU-2P175
200 BW250RAGU-2P200
225 BW250RAGU-2P225
250 BW250RAGU-2P250
400 250 BW400RAGU-2P250 Blank, SB, S7, S8
300 BW400RAGU-2P300
350 BW400RAGU-2P350
400 BW400RAGU-2P400
: Terminal position Breaker type Code Line Load BW50 BW100,125,250 BW400,630,800 Blank Blank SB Screw Flat terminal Block terminal Screw Flat terminal Block terminal l l l l l SF Flat terminal Screw Flat terminal Scre w Block terminal Flat terminal Block terminal Flat terminal Flat terminal Screw Block terminal Screw Block terminal Flat terminal l l l l l l l l l l l l n Type number, Global series (Line protection) l HAGU series, 2-pole UL489 Listed Breaker ampere frame Rated current (A) Type : Available mounting and connection 400 250 BW400HAGU-2P250 Blank, SB, S7, S8
300 BW400HAGU-2P300
350 BW400HAGU-2P350
400 BW400HAGU-2P400
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Line protection l EAGU series, 3-pole UL489 Listed l JAGU series, 3-pole UL489 Listed l SAGU series, 3-pole UL489 Listed l RAGU series, 3-pole UL489 Listed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 100 60 BW100EAGU-3P060 Blank, SB, SF , S3
63 BW100EAGU-3P063 S4, S5, S6, S7, S8
70 BW100EAGU-3P070
75 BW100EAGU-3P075
80 BW100EAGU-3P080
90 BW100EAGU-3P090
100 BW100EAGU-3P100
250 125 BW250EAGU-3P125 Blank, SB, SF , S3
150 BW250EAGU-3P150 S4, S5, S6, S7, S8
160 BW250EAGU-3P160
175 BW250EAGU-3P175
200 BW250EAGU-3P200
225 BW250EAGU-3P225
250 BW250EAGU-3P250
400 250 BW400EAGU-3P250 Blank, SB, S7, S8
300 BW400EAGU-3P300
350 BW400EAGU-3P350
400 BW400EAGU-3P400
(A) Type : Available mounting and connection* 125 15 BW125JAGU-3P015 Blank, SB, SF , S3
20 BW125JAGU-3P020 S4, S5, S6, S7, S8
30 BW125JAGU-3P030
40 BW125JAGU-3P040
50 BW125JAGU-3P050
60 BW125JAGU-3P060
70 BW125JAGU-3P070
75 BW125JAGU-3P075
80 BW125JAGU-3P080
90 BW125JAGU-3P090
100 BW125JAGU-3P100
125 BW125JAGU-3P125
250 125 BW250JAGU-3P125 Blank, SB, SF , S3
150 BW250JAGU-3P150 S4, S5, S6, S7, S8
160 BW250JAGU-3P160
175 BW250JAGU-3P175
200 BW250JAGU-3P200
225 BW250JAGU-3P225
250 BW250JAGU-3P250
(A) Type : Available mounting and connection* 400 250 BW400SAGU-3P250 Blank, SB, S7, S8
300 BW400SAGU-3P300
350 BW400SAGU-3P350
400 BW400SAGU-3P400
(A) Type : Available mounting and connection* 50 3 BW50RAGU-3P003 Blank, SB, S3, S4
5 BW50RAGU-3P005
10 BW50RAGU-3P010
15 BW50RAGU-3P015
20 BW50RAGU-3P020
30 BW50RAGU-3P030
32 BW50RAGU-3P032
40 BW50RAGU-3P040
50 BW50RAGU-3P050
125 15 BW125RAGU-3P015 Blank, SB, SF , S3
20 BW125RAGU-3P020 S4, S5, S6, S7, S8
30 BW125RAGU-3P030
40 BW125RAGU-3P040
50 BW125RAGU-3P050
60 BW125RAGU-3P060
70 BW125RAGU-3P070
75 BW125RAGU-3P075
80 BW125RAGU-3P080
90 BW125RAGU-3P090
100 BW125RAGU-3P100
125 BW125RAGU-3P125
250 125 BW250RAGU-3P125 Blank, SB, SF , S3
150 BW250RAGU-3P150 S4, S5, S6, S7, S8
160 BW250RAGU-3P160
175 BW250RAGU-3P175
200 BW250RAGU-3P200
225 BW250RAGU-3P225
250 BW250RAGU-3P250
400 250 BW400RAGU-3P250 Blank, SB, S7, S8
300 BW400RAGU-3P300
350 BW400RAGU-3P350
400 BW400RAGU-3P400
630 500 BW630RAGU-3P500 Blank, SB, S7, S8
600 BW630RAGU-3P600
630 BW630RAGU-3P630
800 700 BW800RAGU-3P700 Blank, SB, S7, S8
800 BW800RAGU-3P800
l HAGU series, 3-pole UL489 Listed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 400 250 BW400HAGU-3P250 Blank, SB, S7, S8
300 BW400HAGU-3P300
350 BW400HAGU-3P350
400 BW400HAGU-3P400
630 500 BW630HAGU-3P500 Blank, SB, S7, S8
600 BW630HAGU-3P600
630 BW630HAGU-3P630
800 700 BW800HAGU-3P700 Blank, SB, S7, S8
800 BW800HAGU-3P800
- See page 06/34.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series n Type number, Standard series (Motor protection) Type number/Motor protection l SAM series, 2-pole IEC/EN/GB/JIS conformed l AAM series, 3-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection 32 0.7 BW32SAM-2P0P7 Blank, X, E, Y , P
1.4 BW32SAM-2P1P4
2.6 BW32SAM-2P2P6
4 BW32SAM-2P004
8 BW32SAM-2P008
10 BW32SAM-2P010
16 BW32SAM-2P016
24 BW32SAM-2P024
32 BW32SAM-2P032
(A) Type : Available mounting and connection 32 1.4 BW32AAM-3P1P4 Blank, X, E, Y , P
2.6 BW32AAM-3P2P6
4 BW32AAM-3P004
8 BW32AAM-3P008
10 BW32AAM-3P010
16 BW32AAM-3P016
24 BW32AAM-3P024
32 BW32AAM-3P032
l EAM series, 3-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection 50 24 BW50EAM-3P024 Blank, X, E, Y , P
32 BW50EAM-3P032
40 BW50EAM-3P040
45 BW50EAM-3P045
63 63 BW63EAM-3P063 Blank, X, E, Y , P 100 63 BW100EAM-3P063 Blank, X, E, Y , P
75 BW100EAM-3P075
90 BW100EAM-3P090
250 125 BW250EAM-3P125 Blank, X, E, P
150 BW250EAM-3P150
175 BW250EAM-3P175
225 BW250EAM-3P225
l JAM series, 3-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection 125 16 BW125JAM-3P016 Blank, X, E, P
24 BW125JAM-3P024
32 BW125JAM-3P032
40 BW125JAM-3P040
60 BW125JAM-3P060
75 BW125JAM-3P075
90 BW125JAM-3P090
250 125 BW250JAM-3P125 Blank, X, E, P
150 BW250JAM-3P150
175 BW250JAM-3P175
225 BW250JAM-3P225
X E Flush Top and buttom Y Plug-in P
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Motor protection l SAM series, 3-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 32 0.7 BW32SAM-3P0P7 Blank, X, E, Y , P
1.4 BW32SAM-3P1P4
2.6 BW32SAM-3P2P6
4 BW32SAM-3P004
8 BW32SAM-3P008
10 BW32SAM-3P010
16 BW32SAM-3P016
24 BW32SAM-3P024
32 BW32SAM-3P032
50 0.7 BW50SAM-3P0P7 Blank, X, E, Y , P
1.4 BW50SAM-3P1P4
2 BW50SAM-3P002
2.6 BW50SAM-3P2P6
4 BW50SAM-3P004
5 BW50SAM-3P005
8 BW50SAM-3P008
10 BW50SAM-3P010
12 BW50SAM-3P012
16 BW50SAM-3P016
24 BW50SAM-3P024
32 BW50SAM-3P032
40 BW50SAM-3P040
45 BW50SAM-3P045
63 63 BW63SAM-3P063 Blank, X, E, Y , P l RAM series, 3-pole IEC/EN/GB/JIS conformed Breaker ampere frame Rated current (A) Type : Available mounting and connection* 50 0.7 BW50RAM-3P0P7 Blank, X, E, Y , P
1.4 BW50RAM-3P1P4
2 BW50RAM-3P002
2.6 BW50RAM-3P2P6
4 BW50RAM-3P004
5 BW50RAM-3P005
8 BW50RAM-3P008
10 BW50RAM-3P010
12 BW50RAM-3P012
16 BW50RAM-3P016
24 BW50RAM-3P024
32 BW50RAM-3P032
40 BW50RAM-3P040
45 BW50RAM-3P045
125 16 BW125RAM-3P016 Blank, X, E, P
24 BW125RAM-3P024
32 BW125RAM-3P032
40 BW125RAM-3P040
60 BW125RAM-3P060
75 BW125RAM-3P075
90 BW125RAM-3P090
250 125 BW250RAM-3P125 Blank, X, E, P
150 BW250RAM-3P150
175 BW250RAM-3P175
225 BW250RAM-3P225
- See page 06/36.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series n Arc space, mm Arc space A B C F D 3 D 1 D 2 Frame size 32A 50A 63A 100A 125A 160A 250A 400A 630A 800A MCCB basic type BW32" BW32S BW50" BW50E BW50S BW50R BW50H BW63E BW63S BW63R BW100A BW100E BW125J BW125S BW125R BW125H BW160E BW160J BW160S BW160R BW250E BW250J BW250S BW250R BW250H BW400E BW400S BW400R BW400H BW630E BW630R BW630H BW800E BW800R BW800H Ceiling distance A 440V 100 100 100 100 100 100 120 100 100 120 230V 100 100 Vertical distance B 440V 100 100 100 100 100 100 120 100 100 120 230V 100 100 Side plate distance C 440V 230V Front plate distance Painted F 440V 230V Taping Crimp type terminal lug Bus-bar 100 100 100 100 100 100 120 100 100 120 Barrier 100 100 100 100 100 100 120 100 100 120 No painted F 440V 230V Exposed live part dimension +20
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection BW32 -3P, BW50 -3P BW32 -2P, BW50 -2P BW63 -2P Mounting hole Trip button M4 or ø5 R2 or less 52 or more 50 or more Insulation barrier Detachable Panel drilling Front panel cutting Terminal section 100 50 CL 4042 CL 47.5 108 CL ON 608 4 46 2.5 CL CL CL CL MCCB MCCB Max. 15 t 4 ø5.5 M5×14 Insulation barriers Standard provided: BW50SAG, BW50RAG Optional: BW32AAG, BW32SAG, BW50EAG Mounting hole Trip button M4 or ø5 R2 or less 52 or more 74 or more Insulation barrier Detachable Panel drilling Front panel cutting Terminal section CL ON 608 4 46 2.5 CL CL MCCB MCCB Max. 15 t 4 ø5.5 M5×14 100 CL 4042 CL 108 CL CL Insulation barriers Standard provided: BW50SAG, BW50RAG Optional: BW32AAG, BW32SAG, BW50EAG Mounting hole Trip button M4 or ø5 R2 or less 52 or more 50 or more Insulation barrier Detachable Panel drilling Front panel cutting Terminal section 100 50 CL 4042 CL 47.5 108 CL ON 608 4 46 2.5 CL CL CL CL MCCB MCCB 17Max. 15 M8 x 15
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/40 BW63 -3P BW100 -2P BW100 -3P Mounting hole Trip button M4 or ø5 R2 or less 52 or more 74 or more Insulation barrier Detachable Panel drilling Front panel cutting Terminal section CL ON 608 4 46 2.5 CL CL MCCB MCCB 100 CL 4042 CL 108 CL CL 17Max. 15 M8 x 15 Mounting hole Trip button M4 or ø5 R2 or less 52 or more 50 or more Insulation barrier Detachable Panel drilling Front panel cutting Terminal section 100 50 CL 4042 CL 47.5 108 CL ON 608 4 46 2.5 CL CL CL CL MCCB MCCB 17Max. 15 M8 x 15 M5 x 14 for BW100EAG-2P050 Mounting hole Trip button M4 or ø5 R2 or less 52 or more 74 or more Insulation barrier Detachable Panel drilling Front panel cutting Terminal section CL ON 608 4 46 2.5 CL CL MCCB MCCB 100 CL 4042 CL 108 CL CL Insulation barriers Standard provided: BW100EAG Optional: BW100AAG 17Max. 15 M8 x 15 M5 x 14 for BW100EAG-3P050 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard BW125JAG-2P Mounting hole Mounting hole Mounting hole Trip button Trip button Trip button ø4.5 ø8.2 M4 or ø5 M4 or ø5 M4 or ø5 R2 or less 52 or more R2 or less 52 or more R2 or less 52 or more 58 or more 87 or more 117 or more 73.5 or more 43.5 or more Insulation barrier Detachable Insulation barrier Detachable Insulation barrier Detachable Panel drilling Front panel cutting Terminal section Panel drilling Front panel cutting Terminal section Panel drilling Front panel cutting Terminal section 3815 155 135 102 5050 155 135 102 LC 120 72.5 42.5 30 30 30 155 135 102 ON 3.5 687 MCCB 132 MCCB MCCB MCCB MCCB132 MCCB 132 M8 x 16 t<6 Max. 16.5 8 10 8.524 M8 x 16 t<6 10 8.524 M8 x 16 t<6 10 8.524 LC LC LC LCLC LC LC LCø4.5 ø8.2 ON 3.5 687 LC ø4.5 ø8.2 ON 3.5 687 LC LC LC LC LC LC LC LC Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. MCCB 2 3 1
30 M4 or *5
For V, N-type hadle BW50HAG-2P, 3P, BW125JAG-3P, BW125SAG-2P, 3P, BW125RAG-2P, 3P BW125HAG-2P, 3P BW125JAG-4P BW125SAG-4P BW125RAG-4P n Dimensions, mm Front mounting, front connection
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/42 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard Mounting hole Mounting hole Trip button Trip button ø4.5 ø4.5 ø8.2 ø8.2 M4 or ø5 M4 or ø5 R2 or less R2 or less 52 or more 52 or more 137 or more 102 or more 86 or more 51 or more M8 x 16 t<6 Max. 25 Insulation barrier Detachable Insulation barrier Detachable Panel drilling Front panel cutting Panel drilling Front panel cutting Terminal section 105 100 45.5 165 144 102 LC 87.5 140 52.5 85 50 35 35 35 45.5 165 144 102 60 4 ON 643.5 687 MCCB126 MCCB 126 LC MCCB LC MCCB 24 25.5 10.5 11 M8 x 16 t<6 Max. 25 24 25.5 10.5 11 Terminal section LC LC LC LC LC LC LC LC LCLC 60 4 ON 643.5 687 LC Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. BW160 -2P, 3P BW250 -2P, 3P BW160 -4P BW250 -4P n Dimensions, mm Front mounting, front connection
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection Mounting hole Mounting hole Trip button Trip button ø13.5 ø13.5 ø7 ø7 M6 or ø7 M6 or ø7 R2 or less R2 or less 92 or more 92 or more 137 or more 137 or more Insulation barrier Detachable Insulation barrier Detachable Panel drilling Panel drilling Front panel cutting Front panel cutting Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. MCCB 215 225 215 257105 105 135 140 41.5 41.5 24.5 MCCB 225 215 257105 105 44 52.5 132 52.5 52.5 135 185 41.5 41.5 24.5 24.5 MCCB 102 127 103 94.5 117.5 146 MCCB 215 LC LC LC LC LC 102 127 103 94.5 117.5 146 LC LC LC LC LC LC LC LC LC M12 x 35 bolt M12 x 35 bolt 38.5 38.5 105105 102 127 94.5 103 117.5 146 205 243 275 15 328 13.5 MCCB 243 min.207 min.92 M6 or #7 MCCB Max.R2 LC LC LC LC 210 Mounting hole Insulation barrier (removable) Trip button Hexagon head bolt BW400 -2P, 3P BW400 -4P
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/44 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection BW630 -3P BW630 -4P Panel drilling Front panel cutting Panel drilling Front panel cutting 24.5 38.5 105105 102 127 94.5 103 117.5 146 205 243 275 15 328 ø13.5 MCCB 243 207 or more min.92 M6 or ø7 MCCB R2 or less LC LC LC LC 210 Mounting hole Insulation barrier Detachable Trip button M12 x 40 Hexagon head bolt M12 x 40 Hexagon head bolt 105105 102 127 94.5 103 117.5 146 210 7070 205 243 275 24.5 15 32 8 41.5 ø13.5 Trip button Insulation barrier Detachable Mounting hole MCCB R2 or less 243 207 or more min.92 M6 or ø7 MCCB LC LC LC LC Mounting hole Trip button M12 x 40 Hexagon head bolt Insulation barrier Detachable Panel drilling Front panel cutting 38.5 102 127 94.5 103 117.5 146 ø13.5 38.5 CL CL M6 or ø7 CL LCLC LC MCCB MCCB 280 70 70 70 75.5 205 105275 243 105 8 3215 70 70 44 92 or more 207 or more70 243 R2 or less
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice BW800 -3P Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection Panel drilling Front panel cutting Panel drilling Front panel cutting 24.5 38.5 105105 102 127 94.5 103 117.5 146 205 243 275 15 328 ø13.5 MCCB 243 207 or more min.92 M6 or ø7 MCCB R2 or less LC LC LC LC 210 Mounting hole Insulation barrier Detachable Trip button M12 x 40 Hexagon head bolt M12 x 40 Hexagon head bolt 10 105105 102 127 94.5 103 117.5 146 210 7070 205 243 275 24.5 15 32 8 41.5 ø13.5 Trip button Insulation barrier Detachable Mounting hole MCCB R2 or less 243 207 or more min.92 M6 or ø7 MCCB LC LC LC LC BW800 -4P Mounting hole Trip button M12 x 40 Hexagon head bolt Insulation barrier Detachable Panel drilling Front panel cutting 38.5 102 127 94.5 103 117.5 146 ø13.5 38.5 CL CL M6 or ø7 CL LCLC LC MCCB MCCB 280 70 70 70 75.5 205 105275 243 105 8 3215 70 70 44 92 or more 207 or more70 243 R2 or less
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/46 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW32 -3P, BW50 -3P BW32 -2P, BW50 -2P BW63 -2P Mounting hole Trip button M4 or ø5 ø22 MCCB Panel drilling Terminal cover Terminal cover Pannel ø6.5 (M6 x 18 bolt) Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 110 C L C L 25 47.5 C L C L 100 137 C L 45 8 8 95 50.5 68 8 4 C L 110 ON Mounting hole Trip button M4 or ø5 ø22 Panel drilling Terminal cover Terminal cover Pannel ø6.5 (M6 x 18 bolt) Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 100
137 C L
50.5 68 8 4 C L 110 ON 110 MCCB C L C L 45 8 95 8 25 25 C L Mounting hole Trip button M4 or ø5 ø22 MCCB Panel drilling Terminal cover Terminal cover Pannel ø6.5 (M6 x 18 bolt) Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 110 C L C L 25 47.5 C L C L 100 137 C L 45 8 8 95 50.5 68 8 4 C L 110 ON
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice BW63 -3P BW100 -2P BW100 -3P Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) Mounting hole Trip button M4 or ø5 ø22 Panel drilling Terminal cover Terminal cover Pannel ø6.5 (M6 x 18 bolt) Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 100
50.5 68 8 4 C L 110 ON 110 MCCB C L C L 45 8 95 8 25 25 C L Mounting hole Trip button M4 or ø5 ø22 MCCB Panel drilling Terminal cover Terminal cover Pannel ø6.5 (M6 x 18 bolt) Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 110 C L C L 25 47.5 C L C L 100 137 C L 45 8 8 95 50.5 68 8 4 C L 110 ON Mounting hole Trip button M4 or ø5 ø22 Panel drilling Terminal cover Terminal cover Pannel ø6.5 (M6 x 18 bolt) Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 100
50.5 68 8 4 C L 110 ON 110 MCCB C L C L 45 8 95 8 25 25 C L
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/48 Mounting hole Terminal cover Pannel Mounting hole Mounting hole Trip button Trip button Trip button M4 or ø5 M4 or ø5 M4 or ø5 M4 or ø5 Panel drilling Panel drilling Panel drilling L C L C 155 102 5 5 15 15 2.5 L C L C 155 102 5 5 30 30 15 15 2.5 L C L C 120 72.5 42.5 155 102 5 5 30 30 30 15 15 2.5 L C ON 3.5 7 135 5 L C L C MCCB MCCB MCCB 135 132 L C L C 135 132 L C L C 135 132 Terminal cover Pannel L C ON 3.5 7 135 5 Terminal cover Pannel L C ON 3.5 7 135 5 Insulation tubu Insulation tubu Insulation tubu ø8.5 (M8 x 25 bolt) ø8.5 (M8 x 25 bolt) ø8.5 (M8 x 25 bolt) ø8.5 (M8 x 25 bolt) ø18 ø18 ø18 ø18 For V, N-type handle Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. L C L C MCCB 5 3 1 2 3 1 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW125JAG-2P BW50HAG-2P, 3P, BW125JAG-3P BW125SAG-2P, 3P, BW125RAG-2P, 3P BW125HAG-2P, 3P BW125JAG-4P BW125SAG-4P BW125RAG-4P
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Mounting hole Mounting hole Terminal cover Pannel Trip button Trip button M4 or ø5 M4 or ø5 Panel drilling Panel drilling MCCB MCCB ø24 ø24 L C 35 35 35 52.5 144 126 105 100 165 102 5 5 35 35 93.5 57.5 20 14 L C 85 50 52.5 165 140 102 5 5 35 35 35 93.5 57.5 20 14 ON 64 Max. 6 3.5 144 144 126 L C L C L C L C Terminal cover Pannel ON 64 Max. 6 3.5 144 5 L C L C L C L C (M8 x 25 bolt) (M8 x 25 bolt) Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. BW160 -2P, 3P BW250 -2P, 3P BW160 -4P BW250 -4P Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/50 Mounting hole Mounting hole Panel Angle Angle Angle Special nut (supplied) Special nut (supplied) M6 or ø7 M6 or ø7 ø35 ø35 M12 x 35 bolt Live section cover Live section cover Insulation tube Insulation tube Panel drilling Panel drilling Angle mounting Angle mounting Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90˚. 44 44 44 140 266 257 4.5 4.5 102 L C 185 70.5 266 257 4.5 4.5 102 ON 4.5 60 110 115 106.5 158 15 27 225 225 215 5 5 5 5 MCCB 225 215 5 5 5 5 44 44 MCCB L C 44 44 160 15 15 108 MCCB 160 15 15 108 MCCB L C L C L C L C Panel Angle M12 x 35 bolt ON 4.5 60 110 115 106.5 158 15 27 225 L C L C L C L C L C L C L C L C BW400 -2P, 3P BW400 -4P Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Panel drilling Angle mounting Panel drilling Angle mounting Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. 1 Connectable area. Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. 1 Connectable area. 24.5 127 102 129.5 158 20 32 8 413 106.5 115 85*1 M12X40Bolt 180 125 243 70 70 275 11 11 297 210 243 5 5 10 70 140 160 15 178 MCCB M6 or ø7 ø48 40X40X5 MCCB Angle L C C L L C L C C C L L C C L L ON Trip button Angle Panel Insulation barrier Live section cover Mounting hole ø13 C L C C L L C L C L C C L L C C L L ON Trip button Angle Panel Live section cover Mounting hole ø4 11.5 24.5 127 102 129.5 158 20 32 8 413 106.5 115 85*1 M12X40Bolt 180 125 243 70 70 275 11 11 297 210 243 5 5 10 140 160 15 178 MCCB M6 or ø7 ø48 40X40X5 MCCB Angle Insulation barrier BW630 -3P BW630 -4P Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) Mounting hole Trip button ø13 M12 x 40 bolt Panel Angle Insulation barrier Live section cover Panel drilling Angle mounting 129.5 158 20 32 8 413 106.5 115 85*1 180 125 243 ø48 L C ON 43 10 243 5 5 10 70 70 160 15 248 MCCB MCCB M6 or ø7 Angle 40 x 40 5 C C L L C C L L 205 24.5 128 127 102 75.5 70 70 275 11 11 297 280 C C L L C L Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. *1 Connectable area.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/52 Panel drilling Angle mounting Panel drilling Angle mounting Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. 1 Connectable area. Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. 1 Connectable area. 24.5 127 102 129.5 158 20 32 8 413 106.5 115 85*1 M12X40Bolt 180 125 243 70 70 275 11 11 297 210 243 5 5 10 70 140 160 15 178 MCCB M6 or ø7 ø48 40X40X5 MCCB Angle L C C L L C L C C C L L C C L L ON Trip button Angle Panel Insulation barrier Live section cover Mounting hole ø13 C L C C L L C L C L C C L L C C L L ON Trip button Angle Panel Live section cover Mounting hole ø4 11.5 24.5 127 102 129.5 158 20 32 8 413 106.5 115 85*1 M12X40Bolt 180 125 243 70 70 275 11 11 297 210 243 5 5 10 140 160 15 178 MCCB M6 or ø7 ø48 40X40X5 MCCB Angle Insulation barrier BW800 -3P BW800 -4P Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) Mounting hole Trip button ø13 M12 x 40 bolt Panel Angle Insulation barrier Live section cover Panel drilling Angle mounting 129.5 158 20 32 8 413 106.5 115 85*1 180 125 243 ø48 L C ON 43 10 243 5 5 10 70 70 160 15 248 MCCB MCCB M6 or ø7 Angle 40 x 40 5 C C L L C C L L 205 24.5 128 127 102 75.5 70 70 275 11 11 297 280 C C L L C L Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view.
- Studs for line side terminal : Mounted horizontally.
- Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. 1 Connectable area.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW50RAGU-2P BW50RAGU-3P Mounting hole Terminal cover (Short type) Trip button Panel drilling Front panel cutting Terminal section CL 4 8 ON 48.5 2.551 LC LC 9.8 9.8100 42 40 LC LC M4 or ø5 MCCB LC MCCB CL 50 or more 52 or more R2 or less 8 8.3 M5 x 14 Mounting hole Terminal cover (Short type) Trip button Panel drilling Front panel cutting Terminal section LC CL 9.8 9.8100 4042 CL 4 8 ON 48.5 2.551
43 M4 or ø5
8 8.3 M5 x 14
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/54 Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW100EAGU-2P BW100EAGU-3P Mounting hole Terminal cover (Short type) Trip button Panel drilling Front panel cutting Terminal section C L 4 8 ON 48.5 2.5 51 L C L C 9.8 9.8 100 42 40 L C L C M4 or ø5 MCCB L C MCCB C L 50 or more 52 or more R2 or less M8 x 15 8 8.3 24 17 Mounting hole Terminal cover (Short type) Trip button Panel drilling Front panel cutting Terminal section LC CL 9.8 9.8100 4042 CL 4 8 ON 48.5 2.551 8 8.3 24 17
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Panel drilling Panel drilling 2-pole 3-pole (2-pole) 3-pole (2-pole) 2-pole 3-pole (2-pole) Front panel cutting Front panel cutting Terminal section Terminal section MCCB 132 58 or more 52 or more MCCB R2 or less 87 or more 52 or more 52 or more MCCB R2 or less R2 or less M8 x 16 M8 x 16 t<6 10 8.5 Max. 16.5 MCCB132 LC LC LC LC LC LC LC LC LC LC 135 155 5050 102LC Insuration barrier Detachable Insuration barrier Detachable Insuration barrier Detachable Mounting hole Mounting hole Mounting hole Trip button Trip button Trip button M4 or ø5 M4 or ø5 M4 or ø5 135 155 5050 102LC LC 460 ø4.5 ø4.5 ø8.2 ø8.2 687 3.5 ON t<6 Max. 25 Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 2425.5 10.5 11 MCCB126 LC LC 102 105 460 3.5 7 68 100 45.5 144 165 ON LC LCLC 102 or more MCCBLC LC BW125 U-2P, 3P BW250 U-2P, 3P Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice06/56 BW400 U-2P, 3P Mounting hole Trip button ø13.5 M6 or ø7 R2 or less 92 or more 137 or more Insulation barrier Detachable Panel drilling 3-Pole (2-pole) Front panel cutting Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 225 215 257105 105 135 140 41.5 41.5 24.5 MCCB 102 127 103 94.5 117.5 146 MCCB 215 LC LC LC LC LC LC LC M12 x 35 bolt Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW630 U-3P 38.5 105105 102 127 94.5 103 117.5 146 205 243 275 15328 ø13.5 MCCB 243 M6 or ø7 207 or more 92 or more R2 or less MCCB LC LC LC LC LC LC LC 70 70 24.5 210 38.5 Mounting hole Trip button M12 x 40 Hexagon head bolt Insulation barrier Detachable Panel drilling Front panel cutting
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW800 U-3P 41.5 105105 102 127 94.5 103 117.5 146 205 243 275 15328 ø13.5 MCCB 243 M6 or ø7 207 or more 92 or more R2 or less MCCB LC LC LC LC LC LC LC 70 70 24.5 210 41.5 Mounting hole Trip button M12 x 40 Hexagon head bolt Insulation barrier Detachable Panel drilling Front panel cutting
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series BW32, 50, 63, 100 BW50HAG, BW125 n Characteristic curves / Line protection Characteristic curves 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1 1.5 2 3 4 5 6 78 10 15 20 30 4050 70 100 Muitiple of rated current Instantaneous tripping characteristic 960%-1440% Max. value Min. value MinuteSecond Operating time Rated current: 5, 10, 32, 40, 60, 63, 70, 75, 80, 90A 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1 1.5 2 3 4 5 6 78 10 15 20 30 4050 70 100 Muitiple of rated current Instantaneous tripping characteristic 800%-1200% Max. value Min. value MinuteSecond Operating time Rated current: 3, 15, 20, 30, 50,100A -10 0 10 20 30 40 50 400 300 350 250 200 150 100 Reference temp. 40 Operating time correction ratio (%) Ambient temperature ( ) Temperature correction curve Temperature correction curve
- 15A • 20A
- 15-30A
- 30A 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 100 Muitiple of rated current Instantaneous tripping characteristic 500A±100A Max. value Min. value Max. total fault clearing time 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 100 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 100 -10 10 0 20 30 40 50 Ambient temp. (°C) 100
150 Minute Second
Reference temp. 40°C Rated current correction ratio (%) Muitiple of rated current Max. value Min. value Max. total fault clearing time Instantaneous tripping characteristic 500A±100A Muitiple of rated current Max. value Min. value Max. total fault clearing time Instantaneous tripping characteristic 500A±100A Minute Second Operating time Minute Second Operating time
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Characteristic curves BW50HAG, BW125 BW160, 250 BW400 n Characteristic curves / Line protection Temperature correction curve
- 40A • 50-125A
- 40-125A 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 100 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 100 -10 10 0 20 30 40 50 100 150 Reference temp. 40°C Ambient temp. (°C) Rated current correction ratio (%) Muitiple of rated current Muitiple of rated current Max. value Max. value Min. value Min. value Max. total fault clearing time Max. total fault clearing time Instantaneous tripping characteristic 500A±100A Instantaneous tripping characteristic 10In±20% Minute Second Operating time Minute Second Operating time Temperature correction curve Temperature correction curve Reference temp. 40°C Reference temp. 40°C Ambient temp. (°C) Ambient temp. (°C) Rated current correction ratio (%) Rated current correction ratio (%) 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 100 −10 10 0 20 30 40 50 100 150 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 78 10 15 20 30 40 5060 80 100 −10 10 0 20 30 40 50 100 150 Muitiple of rated current Muitiple of rated current Max. value Min. value Max. total fault clearing time Instantaneous tripping characteristic 10In±20% Max. value Min. value Max. total fault clearing timeInstantaneous tripping characteristic 10In±20% Minute Second Operating time MinuteSecond Operating time
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Characteristic curves BW630 BW800 n Characteristic curves / Line protection Temperature correction curve Reference temp. 40°C Ambient temp. (°C) Rated current correction ratio (%) 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 100 −10 10 0 20 30 40 50 100 150 Muitiple of rated current Max. value Min. value Max. total fault clearing time Instantaneous tripping characteristic 10In±20% Minute Second Operating time Temperature correction curve Reference temp. 40°C Ambient temp. (°C) Rated current correction ratio (%) −10 10 0 20 30 40 50 100 150 Muitiple of rated current MinuteSecond Operating time1 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1 1.5 2 3 4 5 6 78 10 15 20 30 40506080100 Max. value Min. value Max. total fault clearing time Instantaneous tripping characteristic 640-960%
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series BW32, 50, 63, 100 BW125 n Characteristic curves / Motor protection -10 0 10 20 30 40 50 400 300 350 250 200 150 100 Reference temp. 40 Operating time correction ratio (%) Ambient temperature ( ) Temperature correction curve 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1 1.5 2 3 4 5 6 78 10 15 20 30 4050 70 100 Muitiple of rated current Instantaneous tripping characteristic 960%-1440% Max. value Min. value MinuteSecond Operating time
- 16A • 24A • 32A
- 40-90A Temperature correction curve
- 15-32A 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 78 10 15 20 30 40 5060 80 100 Muitiple of rated current Muitiple of rated current Muitiple of rated current Muitiple of rated current 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 6080 100 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 7 8 10 15 20 30 40 5060 80 100 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1.5 2 3 4 5 6 78 10 15 20 30 40 5060 80 100 −10 10 0 20 30 40 50 100 150
- 40-125A -10 10 0 20 30 40 50 100 150 Reference temp. 40°CReference temp. 40°C Ambient temp. (°C)Ambient temp. (°C) Rated current correction ratio (%) Rated current correction ratio (%) Max. value Max. value Max. value Max. value Min. value Min. value Min. value Min. value Max. total fault clearing time Max. total fault clearing time Max. total fault clearing time Max. total fault clearing time Instantaneous tripping characteristic 500A±100A Instantaneous tripping characteristic 1200-1800% Instantaneous tripping characteristic 500A±100A Instantaneous tripping characteristic 500A±100A MinuteSecond Operating time MinuteSecond Operating time MinuteSecond Operating time MinuteSecond Operating time Characteristic curves
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series BW250 n Characteristic curves / Motor protection Temperature correction curve Muitiple of rated current Reference temp. 40°C Rated current correction ratio (%) MinuteSecond Operating time1 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 120 180 1 1.5 2 3 4 5 6 78 10 15 20 30 40 5060 80 100 −10 10 0 20 30 40 50 Ambient temp. (°C) 100 150 Max. value Min. value Max. total fault clearing time Instantaneous tripping characteristic 1040A-1560A Characteristic curves
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Auxiliary switch (Type W) This switch is used for indicator lamp or control circuit. See page 06/69. Alarm switch (Type K) This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped. See page 06/69. Shunt trip device (Type F) The purpose of this accessory is to trip the breaker from a distance. See page 06/70. Undervoltage trip device (Type R) The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating. See page 06/70. Terminal block (Type A) A wiring terminal for internal accessories (Order with W, K or F) See page 06/71. Molded Case Circuit Breakers G-TWIN series Accessories n Variation of internal accessory
- 32 to100AF
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Accessories Auxiliary switch (Type W) This switch is used for indicator lamp or control circuit. See page 06/69. Alarm switch (Type K) This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped. See page 06/69. Shunt trip device (Type F) The purpose of this accessory is to trip the breaker from a distance. See page 06/70. Undervoltage trip device (Type R) The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating. See page 06/70. Terminal block (Type A) A wiring terminal for internal accessories (Factory-mounted) See page 06/71. n Variation of internal accessory
- 125 to 250AF
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Accessories n Variation of internal accessory
- 400 to 800AF Auxiliary switch (Type W) This switch is used for indicator lamp or control circuit. See page 06/69. Alarm switch (Type K) This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped. See page 06/69. Shunt trip device (Type F) The purpose of this accessory is to trip the breaker from a distance. See page 06/70. Undervoltage trip device (Type R) The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating. See page 06/70. Terminal block (Type A) A wiring terminal for internal accessories (Factory-mounted) See page 06/71.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Variation of external accessory Molded Case Circuit Breakers G-TWIN series Accessories Terminal cover Long type See page 06/90. Interphase barrier See page 06/92. Handle locking cover (L1) See page 06/93. Padlocking device See page 06/93. External operating handles
- N-type See page 06/79.
- V-type See page 06/79.
- F-type See page 06/79. Terminal cover Short type See page 06/91.
- Cap type (Q1, QN)
- Plate type (Q2) Steel enclosures See page 06/88. Motor-operating mechanism See page 06/74. Mechanical interlock device See page 06/75.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Terminal blocks for auxiliary circuit
- It indicates the terminal No. of internal accessory.The connection method of internal accessory is lead-wire system and terminal block system.
- For the available configuration of internal accessory, see page 06/68.
- Terminal number of internal accessory Accessory Auxiliary switch Alarm switch Shunt trip device : F Undervoltage trip device : R Note: * ( ) Code of Low level circuit SPDT: W (1)* 2PDT: V (2)* SPDT: K (8)* 2PDT: J (9)* With 1NO contact to prevent coil burn-out Continuous rating 32 – 250AF Left side mounting Right side mounting 400 – 800AF Left side mounting AXcR AXbR AXaR AXcR AXbR AXaR ALcR ALbR ALaR ALcR ALbR ALaR AXcL AXbL AXaL AXc AXb AXa AXc AXb AXa AXcL AXbL AXaL AXc AXb AXa ALcL ALbL ALaL ALc ALb ALa ALc ALb ALa ALcL ALbL ALaL ALc ALb ALa Lead-wire wiring With terminal block Molded Case Circuit Breakers G-TWIN series Internal accessories
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Available configurations Auxliary switch SPDT: W (1)* Alarm switch SPDT: K (8)* Shunt trip: F Undervoltage trip: R W+K (1+8) Auxliary switch 2PDT: V (2) Alarm switch 2PDT: J (9) V+K (2+8) W+J (1+9) V+J (2+9) W+F (1+F) W+R (1+R) K+F (8+F) K+R (8+R) W+K+F (1+8+F) W+K+R (1+8+R) V+F (2+F) V+R (2+R) J+F (9+F) J+R (9+R) V+K+F (2+8+F) V+K+R (2+8+R) W+J+F (1+9+F) W+J+R (1+9+R) V+J+F (2+9+F) V+J+R (2+9+R) MCCB Pole 22 3 2, 3 4 2, 3, 4 Notes: •The above table is applied to front mounting type, rear mounting type, flush mounting type, and plug-in mounting type.
- Terminal block is attached on the same side of the accessory.
- ( ) Code of low level circuit ˘:See page 06/2. * 1 Configurations with terminal block are not available. * 2 Flush mounting, rear contection type breakers of 100AF or less are not available. BW125JAG-2P BW125JAGU-2P BW400 BW630 BW800 BW125 BW160 BW250 (Except for BW125JAG-2P , BW125JAGU-2P) BW32˘-3P BW50˘-3P BW63˘-3P BW100˘-3P BW32˘-2P BW50˘-2P BW63˘-2P BW100˘-2P *2 *2 *2 *1 *2 *2 *2 *2 Handle Handle Handle 2-pole 3-pole 4-pole Left Right Right Shunt trip: FUndervoltage trip: R (Internal) Auxiliary switch: W Alarm switch: K Lead wireUndervoltage trip: R (External) Left Right Molded Case Circuit Breakers G-TWIN series Internal accessories
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Internal accessories n Operation of auxiliary switches(W) and alarm switches(K) Accessory Auxiliary switch Alarm switch SPDT: W (1) SPDT: K (8) 2PDT: J (9) 2PDT: V (2) Handle position ON OFF Trip 11/AXcL 12/AXbL 14/AXaL 11/AXcL 12/AXbL 14/AXaL 21/AXcR 22/AXbR 24/AXaR 91/ALcL 94/ALaL 92/ALbL 91/ALcL 94/ALaL 92/ALbL 01/ALcR 04/ALaR 02/ALbR 91/ALcL 94/ALaL 92/ALbL 91/ALcL 94ALaL 92/ALbL 01/ALcL 04/ALaL 02/ALbL 11/AXcL 12/AXbL 14/AXaL 11/AXcL 12/AXbL 14/AXaL 21/AXcR 22/AXbR 24/AXaR Note: Ring mark indication ( ) Code of low level circuit n Ratings of auxiliary switches(W) and alarm switches(K) Minimum load current 5V DC 160mA 30V DC 30mA 5V DC 1mA Rated operational Voltage (V) 125 250 Rated operational Voltage (V) 125 250 Ind. load Res. load 0.1 Ind. load 0.4 0.2 Res. load 2.5 0.4 0.2 0.1 Rated operational current (A) AC DC
- 125-800AF Rated thermal current (A) 0.1 Standard type Low level circuit Standard type Low level circuit
- 32-100AF Voltage (V) 125 AC 250 AC 125 DC 250 DC AC 15 DC 13 0.6 0.3 Voltage (V) 125 AC 250 AC 30 DC 125 DC 250 DC 30 DC Res. load 0.4 0.2 0.1 IEC60947-5-1 NECA C4505 Make/break current (A) Make/break current (A) Minimum load current 5V DC 160mA 30V DC 30mA 5V DC 1mA
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Rating of shunt trip (F) n Rating of undervoltag e trip (R) 7-13 13-21 8-20 AC DC Opearting time (ms) MCCB type BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 V 100-120 200-240 380-450 100-120 120-130 200-240 277 380-440 440-480 500-550 24-48 100-240 277 380-550 24-48 100-220 VA 150 150 200 150 V 100-110 100-110 200-220 Code FAC/DC24-48V FAC100-240V DC100-220V FAC277V FAC380-550V FAC100-120V/ DC100-110V FAC200-240V FAC380-450V FAC/DC24V FAC/DC24V FAC/DC48V FAC100-120V/ DC100-110V FAC120-130V FAC200-240V/ DC200-220V FAC277V FAC380-440V FAC440-480V FAC500-550V Continuous W 150 150 Continuous (With 1NO contact to prevent coil burn-out) Time rating of coil Note: The operating tripping voltage range for shunt trip devices is 70% to 110% of the rated operating voltage. 100 (50Hz)/ 100-110(60Hz) 200 (50Hz)/ 200-220 (60Hz) 400 (50Hz)/ 400-440 (60Hz) 100-110 110-130 200-240 277 380-415 440-480 100-110 100-110 125 BW32 * BW50 *2 BW63 *2 BW100 *2 BW125 *1 BW160 *1 BW250 *1 AC DCMCCB type Installation External Internal Internal Code RAC100(50Hz)/ 100-110V(60Hz) RAC200(50Hz)/ 200-220V(60Hz) RAC400(50Hz)/ 400-440V(60Hz) RDC24V RDC100-110V RDC24V RDC48V RDC100-110V RDC125V RAC100-110V RAC110V-130V RAC200-240V RAC277V RAC380-415V RAC440V-480V RAC/DC24V RAC/DC48V RAC/DC100-110V RAC120-130V/DC125V RAC200-240V/DC200-220V RAC277V RAC380-480V BW400 * BW630 *2 BW800 *2 V 100-110 120-130 200-240 277 380-480 100-110 125 200-220 VA V W Notes: • The operating voltages of undervoltage tripping devices are as follows: Tripping voltage: 35% to 70% of rated voltage, closing voltage: 85% to 110% of rated voltage. *1 Reset-allowed type: When the breaker handle is in the OFF or RESET state, tripping does not occur even if the R coil is not energized. Turning ON with the R coil not energized causes normal tripping. *2 Reset-prohibited type: When the R coil is not energized, reset operation cannot reset the tripped breaker to the OFF state. 2.8 3.4 4.4 Molded Case Circuit Breakers G-TWIN series Internal accessories
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Lead wire specification 125AF , 160AF , 250AF32AF , 50AF , 63AF , 100AF 400AF , 630AF , 800AF Notes: * If the chosen combination has more than 8 terminals, 2 terminal blocks are mounted.
- Mount the terminal block on the surface on which the accessories are mounted. See the table of the combinations of internal accessories on pages 06/68. for information on the accessory mounting position.
- Available wire: Solid wire: 1.6ø Stranded wire: 2mm
- Terminal blocks are available as factory mounted only. 100.5 53.5 30.5 M3.5 Load Line (Left) Terminal block * (Right) 8 8 6.5 81.5 56.5 9.5 80 11 117.5 CL 51.5 39.3 12.5 77.2 53.7 30.2 M3.5 LC LC LC LC CL CL 48.5 23.5 48 9 77.2 53.7 30.2 12.5 n Terminal blocks n Undervoltage trip device 32AF , 50AF , 63AF , 100AF AF Pole wire size Wire length 32 to 100AF – 0.4mm (AWG22) Ca 500mm 125 to 250AF 2P , 3P 0.5mm (AWG20) 400 to 800AF 2P , 3P 0.5mm Ca 500mm 4P Ca 400 to 450mm Molded Case Circuit Breakers G-TWIN series Internal accessories M3.5 2575 Mass: 0.15kg 10.545 41.5 100 CL CL CL
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Internal accessories (Sold separately)
- 32, 50, 63, 100AF IEC/EN/GB/JIS conformed n Type number Accessory Type Operating voltge Lead wire system Terminal block system Left side Right side Left side Right side Auxiliary switch BZ6WL10C BZ6WR10C BZ6WL10CA BZ6WR10CA Auxiliary switch (low level circuit) BZ6WDL10C BZ6WDR10C BZ6WDL10CA BZ6WDR10CA Alarm switch BZ6KL10C BZ6KR10C BZ6KL10CA BZ6KR10CA Alarm switch (low level circuit) BZ6KDL10C BZ6KDR10C BZ6KDL10CA BZ6KDR10CA Auxiliary switch + Alarm switch BZ6WKL10C BZ6WKR10C BZ6WKL10CA BZ6WKR10CA Auxiliary switch + Alarm switch (low level circuit) BZ6WDKDL10C BZ6WDKDR10C BZ6WDKDL10CA BZ6WDKDR10CA Shunt trip device – BZ6FA10C – BZ6FA10CA 100-120V AC/100-110V DC – BZ6FK10C – BZ6FK10CA 200-240V AC – BZ6FP10C – BZ6FP10CA 380-450V AC – BZ6FR10C – BZ6FR10CA 24V AC/DC Undervoltage trip device – – – BZ6R210C 100V AC 50Hz/100-110V AC 60Hz – – – BZ6R110C 110V AC 50Hz/110-127V AC 60Hz – – – BZ6RW10C 200V AC 50Hz/200-220V AC 60Hz – – – BZ6R410C 220V AC 50Hz/220-240V AC 60Hz – – – BZ6R510C 230V AC 50Hz/230-240V AC 60Hz – – – BZ6R810C 240V AC 50Hz – – – BZ6R010C 380V AC 50Hz 380-415V AC 60Hz – – – BZ6R910C 400V AC 50Hz 400-440V AC 60Hz – – – BZ6RF10C 24V DC – – – BZ6RT10C 100-110V DC Molded Case Circuit Breakers G-TWIN series Internal accessories Accessory Type Operating voltge Lead wire system Terminal block system Left side Right side Left side Right side Auxiliary switch BZ6WL10CU BZ6WR10CU BZ6WL10CAU BZ6WR10CAU Auxiliary switch (low level circuit) BZ6WDL10CU BZ6WDR10CU BZ6WDL10CAU BZ6WDR10CAU Alarm switch BZ6KL10CU BZ6KR10CU BZ6KL10CAU BZ6KR10CAU Alarm switch (low level circuit) BZ6KDL10CU BZ6KDR10CU BZ6KDL10CAU BZ6KDR10CAU Auxiliary switch + Alarm switch BZ6WKL10CU BZ6WKR10CU BZ6WKL10CA BZ6WKR10CAU Auxiliary switch + Alarm switch (low level circuit) BZ6WDKDL10CU BZ6WDKDR10CU BZ6WDKDL10CAU BZ6WDKDR10CAU Shunt trip device – BZ6FA10CU – BZ6FA10CAU 100-120V AC/100-110V DC – BZ6FK10CU – BZ6FK10CAU 200-240V AC – BZ6FP10CU – BZ6FP10CAU 380-450V AC Undervoltage trip device – – – BZ6R210CAU 100V AC 50Hz/100-110V AC 60Hz – – – BZ6RW10CAU 110V AC 50Hz/110-127V AC 60Hz – – – BZ6R910CAU 200V AC 50Hz/200-220V AC 60Hz
- 50, 100AF IEC/EN/GB/JIS/UL/CSA conformed
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Accessory Type Operating voltge Lead wire system Terminal block system Left side Right side Left side Right side * Auxiliary switch BW9W1SG0 BW9W1SG0-R BW9W1SG0-A – – Auxiliary switch (low level circuit) BW9W1DG0 BW9W1DG0-R – * Alarm switch BW9K1SG0 BW9K1SG0-R BW9K1SG0-A Alarm switch (low level circuit) BW9K1DG0 BW9K1DG0-R – * Auxiliary switch + Alarm switch BW9WKSG0 BW9WK1SG0-R BW9WKSG0-A Auxiliary switch + Alarm switch (low level circuit) BW9WKDG0 BW9WK1DG0-R – * Shunt trip device BW9FRG0 BW9FRG0 BW9FRG0-A 24V AC/DC BW9FSG0 BW9FSG0 BW9FSG0-A 48V AC/DC BW9FAG0 BW9FAG0 BW9FAG0-A 100-120V AC/100-110V DC BW9F1G0 BW9F1G0 BW9F1G0-A 120-130V AC BW9FKG0 BW9FKG0 BW9FKG0-A 200-240V AC/200-220V DC BW9FBG0 BW9FBG0 BW9FBG0-A 277V AC BW9FPG0 BW9FPG0 BW9FPG0-A 380-440V AC BW9FHG0 BW9FHG0 BW9FHG0-A 440-480V AC BW9FJG0 BW9FJG0 BW9FJG0-A 500-550V AC Undervoltage trip devics BW9RGAR – BW9RGAR-A 24V DC BW9RGAS BW9RGAS-A 48V DC BW9RGAL BW9RGAL-A 100-110V DC BW9RGA5 BW9RGA5-A 125V DC BW9RGAA BW9RGAA-A 100-110V AC BW9RGAT BW9RGAT-A 110-130V AC BW9RGAK BW9RGAK-A 200-240V AC BW9RGAB BW9RGAB-A 277V AC BW9RGAP BW9RGAP-A 380-415V AC BW9RGAH BW9RGAH-A 440-480V AC Note: * Factory-mounted Note: * Factory-mounted Accessory Type Operating voltge Lead wire system Terminal block system * Left side Auxiliary switch x 1 BW9W1SHA – – Auxiliary switch x 2 BW9W2SHA Auxiliary switch (low level circuit) x 1 BW9W1DHA Auxiliary switch (low level circuit) x 2 BW9W2DHA Alarm switch x 1 BW9K1SHA Alarm switch x 2 BW9K2SHA Alarm switch (low level circuit) x 1 BW9K1DHA Alarm switch (low level circuit) x 2 BW9K2DHA Shunt trip device BW9FHA-R 24-48V AC/DC BW9FHA-A 100-240V AC/100-220V DC BW9FHA-B 277V AC BW9FHA-P 380-550V AC Undervoltage trip devics BW9RHA-R 24V AC/DC BW9RHA-S 48V AC/DC BW9RHA-A 100-110 AC/DC BW9RHA-1 120-130V AC/125V DC BW9RHA-K 200-240V AC/200-220V DC BW9RHA-B 277V AC BW9RHA-P 380-480V AC
- 400, 630, 800AF IEC/EN/GB/JIS/UL/CSA conformed
- 125, 160, 250AF IEC/EN/GB/JIS/UL/CSA conformed Molded Case Circuit Breakers G-TWIN series Internal accessories
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Motor-operated breakers n Description The breaker is fitted with a motor operating mechanism which enables ON, OFF and RESET operations to be carried out electronically by remote control. The breakers do not conform to IEC and EN standard. n Type and ratings n Ordering information Specify the following: 1. Type number 2. Motor operating voltage n Dimensions, mm / Front mounting, front connection BW32 -3P, BW50 -3P, BW63 -3P, BW100 -3P, n Wiring diagrams 100/110V AC, 200/220V AC, 100V DC Terminal cover Mass: 1.2kg (BW32 or BW50 type with motor operating mechanism) 1.3kg (BW63 or BW100 type with motor operating mechanism) Trip button Insulation barrier Mounting hole ø4.5 Operating handle Notes: • Trip button operation can be carried out at right side of the breaker.
- IEC 35mm wide mounting rail is not available. LC CL LC 139 135 100 CL CL M4 or ø5 Panel drilling CL Panel cutting R2 or more 74 or more C MCCB 52 or more L DRIVE UNIT OFF ON Power supply (Non polarity) 4 3 E 2 1 CONTROL CIRCUIT MCCB type BW32-3P M, BW50-3P M, BW63-3P M, BW100-3P M Motor rating Operating voltage 100V DC 100/110V AC 200/220V AC Operating time 0.1s Time rating 15s per on-off operation Power source capacity 500VA Mass (kg) 1.2 1.3
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories These interlocking devices are mounted on the two separate breakers to prevent them from both being closed at the same time. A sliding mechanism that can be locked with a padlock is used. (The padlock is not included.) They are designed for use when changing over power supplies. These can be mounted to 3 types of breakers: front-mounting front-connection type, front-mounting rear-connection type (type X), and plug-in mounting type (type P). Interlock devices for flush mounting type breakers (type E, Y) are also available. Mechanical interlocking devices n Description M1 types n Type and applicable breakers Type Breaker type BZ6M110C2 BW32AAG-2P , BW32SAG-2P BW50AAG-2P , BW50EAG-2P , BW50SAG-2P , BW50RAG-2P BW63EAG-2P , BW63SAG-2P , BW63RAG-2P BW100EAG-2P BZ6M110C3 BW32AAG-3P , BW32SAG-3P BW50AAG-3P , BW50EAG-3P , BW50SAG-3P , BW50RAG-3P BW63EAG-3P , BW63SAG-3P , BW63RAG-3P BW100AAG-3P , BW100EAG-3P BW9M1CA-2 BW125JAG-2P BW9M1CA-3 BW125JAG-3P , BW125SAG-2P , BW125SAG-3P , BW125RAG-2P , BW125RAG-3P BW9M1CA-4 BW125JAG-4P , BW125SAG-4P , BW125RAG-4P BW9M1GA-3 BW160EAG-2P , BW160EAG-3P , BW160JAG-2P , BW160JAG-3P BW160SAG-2P , BW160SAG-3P , BW160RAG-2P , BW160RAG-3P BW250EAG-2P , BW250EAG-3P , BW250JAG-2P , BW250JAG-3P BW250SAG-2P , BW250SAG-3P , BW250RAG-2P , BW250RAG-3P BW9M1GA-4 BW160JAG-4P , BW160SAG-4P , BW160RAG-4P BW250JAG-4P , BW250SAG-4P , BW250RAG-4P BW9M1HA-3 BW400EAG-2P , BW400EAG-3P , BW400SAG-2P , BW400SAG-3P BW400RAG-2P , BW400RAG-3P , BW400HAG-2P , BW400HAG-3P BW9M1HA-4 BW400RAG-4P , BW400HAG-4P BW9M1JA-3 BW630EAG-3P , BW630RAG-3P , BW630HAG-3P BW800EAG-3P , BW800RAG-3P , BW800HAG-3P
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Dimensions, mm
- 32AF to 100AF Panel drilling Molded Case Circuit Breakers G-TWIN series External accessories 2-ø4.5 mounting holePadlock of breaker of sliderCL CL (Not supplied) 100 A B C CL CL CL CL Breaker mounting hole Breaker mounting hole Breaker Breaker BreakerBreaker 2-ø4.5 or M4 2-ø4.5 or M4 of breakerCL of breakerCL BZ6M110C2 BZ6M110C3 100 110 CL CL CL CL Type BZ6M110C2 BZ6M110C3 Dimensions, mm A 110 B 42.5 C 108 Mass (kg) 0.11 0.12 Notes: • BZ6M110C2 is not available for padlock.
- Applicable padlock(ø3.5) dimensions, mm
- External installation forms F and R are not applicable to the MCCB on the left of the diagram. ɹɹ 9.5 12ø3.5 ø3.5
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories n Dimensions, mm
- 125AF to 250AF ON 145 Fig.1 M4 or ø5 M4 or ø5 M4 or ø5 M4 or ø5 2-M4 or ø4.5 2-M4 or ø4.5 2-M4 or ø4.5 2-M4 or ø4.5 D Breaker Breaker Breaker Breaker Breaker Breaker Breaker Breaker Mounting screw: M4 x 10 (x2) 11.7 ø19 165 145 37.6 70.6 A P N B LC L of sliderC Padlock (Not supplied) L of breakerC L of breakerC L of breakerC L of breakerC L of breakerC LC LC LC LC LC C 145 Fig.2 D LC LC C 145 Fig.3 D LC LC C 145 Fig.4 D L Handle C L Handle C Panel drilling Type Dimensions, mm Panel Drilling Mass(Kg) P N A B C D BW9M1CA-2 90 88 150 60 – 132 Fig.1 BW9M1CA-3 120 118 210 90 30 132 Fig.2 BW9M1CA-4 150 148 270 102 30 132 Fig.4 BW9M1GA-3 135 133 240 105 35 126 Fig.3 BW9M1GA-4 170 168 310 140 35 126 Fig.4 Notes: • The dimensions and Breaker mounting holes for back surface mounting are different from those given above. Inquire for details.
- If a padlock is required, use a commercially availab le padlock with the dimensions shown in the diagram at the right.
- External installation forms F and R are not applicab le to the MCCB on the left of the diagram. 9.5 12ø3.5
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Dimensions, mm
- 400AF to 800AF Molded Case Circuit Breakers G-TWIN series External accessories $"˄ +˄+˄ .PS )+ + )BOEMF #SFBLFS #SFBLFS ( - 1BOFMESJMMJOH .PVOUJOHTDSFX -PGTMJEFS$ -PGTMJEFS$ -PGIBOEMF$ -PGIBOEMF$ 1BEMPDL /PUTVQQMJFE -PGCSFBLFS$ -PGCSFBLFS$ Type Dimensions, mm Mass(Kg) A (A') B C D E F G H J (J') K L BW9M1HA-3 355 (70) 257 215 20 94.5 132.5 54.5 171 44 (70) 215 38 BW9M1HA-4 470 (140) 257 260 20 94.5 132.5 54.5 216 44 (140) 215 38 BW9M1JA-3 500 (105) 275 290 20 94.5 132.5 54.5 220 70 (105) 243 38 9.5 12ø3.5 Notes: • The dimensions and Breaker mounting holes for back surface mounting are different from those given above. Inquire for details.
- If a padlock is required, use a commercially availab le padlock with the dimensions shown in the diagram at the right.
- External installation forms F and R are not applicab le to the MCCB on the left of the diagram.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories N type handles BW9N0CA N type handles BW9V0CA V type handle External operating handles n Description Molded case circuit breaker handles are generally directly manual-operated but when mounted in motor control centers or on control panels they are sometimes required to be operated externally. To meet such applications FUJI offers the following three types of handles. N type handle This type has a knob handle directly attached to the breaker. It is easily fitted by cutting a hole in the panel, which is provided with a door interlock. They may be fitted to all breakers up to 800 ampere frame sizes. Conformed to EN60947-1 isolation function. Available for EN60204-1 power breaking device. Conformed to UL489 (File No.E93289) V type handle The V type handle may be fitted to breakers of up to 800AF . A separately sold extension shaft provides distance adjustment between the handle and breaker. Conformed to EN60947-1 isolation function. Available for EN60204-1 power breaking device. Conformed to UL489 (File No.E93289) F type handle The F type handle may be fitted to breakers of 125 to 400AF . It is a flange type handle, which is commonly used in the North American market. The drive section of the breaker and the external operating handle are connected with an optional cable. Positioning between the breaker and the external operating handle is not required. Conformed to UL489 (File No.E93289) V type handles Breaker Decorative plate N type handle on breaker Breaker V type handle on panel F type handles
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories N type handles MCCB N type handle BW32 BZ6N10D BW50 BW63 BW100 BW125 BW9N0CA BW160 BW9N0GA BW250 BW400 BW9N0HA BW630 BW800 BW9N0JA V type handles MCCB V type handle BW32 BZ6V10D BW50 BW63 BW100 BW125 BW9V0CA BW160 BW9V0GA BW250 BW400 BW9V0HA BW630 BW800 BW9V0JA
- V type handle BW9V0CA – Mounting ( For BZ6V10D, BW9V0HA, BW9V0JA) Blank: Front mounting, front connection X: Front mounting, rear connection P: Plug-in mounting Basic type Note: To order a V handle for front-mounting rear connection breakers, add “-X” to the type number; for plug-in mounting breakers, add “-P” to the type number. n Type number nomenclature F type handles MCCB N type handle BW125 BW9F0CA BW250 BW9F0GA BW400 BW9F0HA
- F type handle BW9F0 A Breaker type C: BW125 U G: BW250 U H: BW400 U Basic type Cable (For F type) BW9FW A – A Cable length 15: 1.5m 20: 2.0m 30: 3.0m Breaker type C: BW125 U G: BW250 U H: BW400 U Basic type Terminal cover (For F type) BW9FBT A – L3 Breaker type C: BW125 U G: BW250 U H: BW400 U Basic type
- N type handle BW9N0CA – Mounting ( For BZ6N10D, BW9N0HA, BW9N0JA) Blank: Front mounting, front connection X: Front mounting, rear connection P: Plug-in mounting Basic type
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Notes: • The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately.
- Remove the handle lock bar bef ore opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the loc k bar is engaged.
- Engage the door interlock securely before tur ning ON the power. The Terminal Cover and Handle cannot be attached at the same time for the BW125JAG-2P or BW125RAGU-2P . Select the BW125J AG-3P or BW125RAGU-3P to use a Handle. The terminal cover will cover the mounting screws for the Breaker. When attaching the terminal cover, a por tion of the terminal cover will need to be removed. Remove portion A in the f ollowing diagram. Molded Case Circuit Breakers G-TWIN series External accessories
- BZ6N10D
- BW9N0CA, BW9N0GA n Dimensions, mm N type handle Note: Align the center of the hole cut in the panel with the center of the breaker handle. Handle C/L Door panel cutting 2P 3P 4P 4-ø15
78 MCCB
Max.65 52.5 H 50 108 105 MCCB handle C/L MCCB Load Line Panel Dust proof packing(Optional) Thickness: 1.2 to 3.2 L C L C ø90 Install the hinge in the shaded area. 200 200 1 5 1 9 3 8 2 6 3
49 Padlock size
ø4 to ø8 Handle C/L 1 2 MCCB Handle type Dust proof packing Mounting screw H (mm) Mass (kg) BW32 BZ6N10D Provided M4 x 85 103 0.47 BW50 BZ6N10D-X Provided Contact FUJI. 111 BW63 BZ6N10D-P 111 BW100 MCCB Handle type Dust proof packing Mounting screw H (mm) Mass (kg) BW125 BW9N0CA* BZ-NP-1C M4 x 85 103±2 0.56 BW160 BW9N0GA* BZ-NP-1C M4 x 85 103±2 0.56 BW250 105 105 ø90 4-ø15 H49 104 16 23 2.5 6 2.5 14 8 17 23 110 200200 LC LC LC LC LC Note: Align the center of the hole cut in the panel with the center of the breaker handle. Door panel cutting Install the hinge in the shaded area. Load Line Panel Thickness:1.2 to 3.2 Padlock size ø4 to ø8
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice
- BW9N0HA, BW9N0JA Line Panel thickness: 1.6-3.2 Install the door hinge in the shaded area. 112 112 Mounting screw 4-ø15 150 150 96 96 17 53 157±2 Panel Lock plate Padlock size ø4 to ø8 (Up to 2 ø8 padlocks can be mounted.) 35 7.5 100 100 200 200 Decorative plate ø138 MCCB handle C/L MCCB handle C/L MCCB handle C/L Load Handle C/L Door panel cutting Note: Align the center of the hole cut in the panel with the center of the breaker handle. X-type 169±2 P-type 171±2 400AF 174±2 630AF 219±2 800AF MCCB Handle type Dust proof packing Mounting screw Mass (kg) BW400 BW9N0HA BW9N0HA-X BW9N0HA-P BZ-NP-2 M6 x 110 M6 x 115 Contact FUJI. 1.9 BW630 BW800 BW9N0JA BW9N0JA-X BW9N0JA-P BZ-NP-2 M6 x 110 M6 x 115 Contact FUJI. 1.9 Molded Case Circuit Breakers G-TWIN series External accessories Notes: • The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately.
- Remove the handle lock bar bef ore opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the loc k bar is engaged.
- Engage the door interlock securely before tur ning ON the power.
- Not available f or side mounting.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories
- BZ6V10D
- BW9V0CA, BW9V0GA Door panel cutting X Handle C/L4-ø15 ø90MCCB Handle C/L Padlock size ø4 to ø8 Panel thickness: 1.2 to 3.2 MCCB handle C/L Line Load Panel Note: Align the center of the hole cut in the panel with the center of the breaker handle. Handle C/L 2P 3P Door hinge installation area Optional shaft BZ6VS1D X = H - 105 Install the door hinge in the shaded area. 113 113 62 H 200 2015 73 56 LC LC LC Door panel cutting Shaft Latch (included with the handle) Handle C/L4-ø15 ø90MCCB Handle C/L Padlock size ø4 to ø8 LC 113 113 LC 65 H Panel thickness: 1.2 to 3.2 MCCB handle C/L MCCBLine Load Panel Note: Align the center of the hole cut in the panel with the center of the breaker handle. Handle C/L 2P 3P 4P Door hinge installation area Optional shaft BW9VSG0 X = H - 95 Install the door hinge in the shaded area. 120 120 8 7 2 1 4 9 4 0 3 5 1 C/L 7 2 X n Dimensions, mm V type handle
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Area in which the hinge with H can be installed H Standard type H MCCB Handle type With the optional shaft (X=154) Mounting screw Mass (kg) BW32 BW50 BW63 BW100 BW125 BW160* BW250*2 BZ6V10D BZ6V10D-X BZ6V10D-P BW9V0CA BW9V0GA 105±2 113±2 113±2 105±2 105±2 Optional shaft BZ6VS1D BW9VSG0 250±2 258±2 258±2 250±2 250±2 140 to 250 150 to 258 150 to 258 140 to 250 140 to 250 M4 x 80 Contact FUJI. Contact FUJI. M4 x 85 M4 x 85 0.64 0.64 0.64 0.67 0.67 Notes: • The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately.
- Remove the handle lock bar bef ore opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the loc k bar is engaged.
- Engage the door interlock securely before tur ning ON the power.
- Not available f or side mounting. The Terminal Cover and Handle cannot be attached at the same time for the BW125JAG-2P or BW125RAGU-2P . Select the BW125JAG-3P or BW125RAGU-3P to use a Handle. The terminal cover will cover the mounting screws for the Breaker. When attaching the terminal cover, a portion of the terminal cover will need to be removed. Remove portion A in the f ollowing diagram.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories
- BW9V0HA, BW9V0JA X Optional shaft (BZ-VS2) 100 H 63 200 OFF Panel Decorative plate Mounting screw Load Install the door hinge in the shaded area. Line 150 150 150 Lock plate Padlock size ø4 to ø8 (Up to 2 ø8 padlocks can be mounted.) MCCB handle C/L 112 112 4-ø10 ø138 MCCB handle C/L MCCB handle C/L Panel thickness: 1.6-3.2 Door panel cutting Note: Align the center of the hole cut in the panel with the center of the breaker handle. When using the BZ-VS2 extension shaft to adjust dimension H, cut it according to the equation below. X=H−161.5 MCCB Handle type Optional shaft Standard type H With the optional shaft (X=154) Mass (kg)H Area in which the hinge with H can be installed BW400 BW9V0HA BZ-VS2 190±2 250±2 202 to 250 2.2 BW9V0HA-X 202±2 262±2 214 to 262 BW9V0HA-P 204±2 264±2 216 to 264 BW630 BW9V0JA 190±2 250±2 202 to 250 BW9V0JA-X 202±2 262±2 214 to 262 BW9V0JA-P 207±2 267±2 219 to 269 BW800 BW9V0JA 190±2 250±2 202 to 250 BW9V0JA-X 202±2 262±2 214 to 262 BW9V0JA-P 252±2 312±2 264 to 312 Notes: • The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately.
- Remove the handle lock bar bef ore opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the loc k bar is engaged.
- Engage the door interlock securely before tur ning ON the power.
- Not available f or side mounting.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories
- BW9F0CA n Dimensions, mm F type handle Terminal cover Mounting screw M4 x 90 Drive section Operation section Insulation barrier Protection cover To operation section Panel drilling M4 or ø5 Handle Panel Panel Cable Release lever Lock lever Release screw OFF lock Concave for ON lock* 28 or more RESET 155 132 27.5 12.5 27.5 132 275 Max. 69 149 145 150˚ 119 100 104 117 80 ON 2-ø7 R6.5 2-ø5.5
- This product consists of a drive section and an operation section.
- The operation section can be mounted either to the right or to the left on the panel depending on the mounting position of the release lever.
- For the OFF lock, 3 ø10 padlocks can be mounted; for the ON lock, 2 ø10 padlocks. 1 Set the height to 20 or 30. Adjust the lock lever depending on the setting. *2 The ON lock can be realized by additionally creating a concave for the ON lock.
- BW9F0GA Operation section Drive section To operation section Panel drilling Handle Panel Mounting screw M4 x 90 Panel Cable Release lever Lock lever Release screw OFF lock Concave for ON lock* 28 or more RESET 126 27.5 12.5 27.5 132 275 165 88 Max. 69 149 145 150˚ 119 80 ON 104 115 117 90 Insulation barrier Protection cover 57 M4 or ø5 2-ø7 R6.5 2-ø5.5
- This product consists of a drive section and an operation section.
- The operation section can be mounted either to the right or to the left on the panel depending on the mounting position of the release lever.
- For the OFF lock, 3 ø10 padlocks can be mounted; for the ON lock, 2 ø10 padlocks. 1 Set the height to 20 or 30. Adjust the lock lever depending on the setting. *2 The ON lock can be realized by additionally creating a concave for the ON lock.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories
- BW9F0HA Mounting screw M6 x 110 Operation section Drive section To operation section Panel drilling Handle Panel Panel Cable Release lever Lock lever Release screw OFF lock Concave for ON lock*2 28 or more RESET 214 to 216 27.5 12.5 27.5 132 275 275 Max. 69 149 145 150˚ 119 80 ON 155 108 190 Protection cover Insulation barrier 171 140
44 M6 or ø7
2-ø7 R6.5 2-ø5.5
- This product consists of a drive section and an operation section.
- The operation section can be mounted either to the right or to the left on the panel depending on the mounting position of the release lever.
- For the OFF lock, 3 ø10 padlocks can be mounted; for the ON lock, 2 ø10 padlocks. 1 Set the height to 20 or 30. Adjust the lock lever depending on the setting. *2 The ON lock can be realized by additionally creating a concave for the ON lock. MCCB * Handle type Cable Terminal cover Type Length (m) BW125JAGU-3P BW125RAGU-2P BW125RAGU-3P BW9F0CA BW9FWCA-15A BW9FWCA-20A BW9FWCA-30A 1.5 2.0 3.0 BW9FBTCA-L3 BW250EAGU-2P BW250EAGU-3P BW250JAGU-2P BW250JAGU-3P BW250RAGU-2P BW250RAGU-3P BW9F0GA BW9FWGA-15A BW9FWGA-20A BW9FWGA-30A 1.5 2.0 3.0 BW9FBTGA-L3 BW400EAGU-2P BW400EAGU-3P BW400SAGU-2P BW400SAGU-3P BW400RAGU-2P BW400RAGU-3P BW400HAGU-2P BW400HAGU-3P BW9F0HA BW9FWHA-15A BW9FWHA-20A BW9FWHA-30A 1.5 2.0 3.0 BW9FBTHA-L3 Note: * Not available for BW125JAGU-2P
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Steel enclosures n Description Steel enc losures are available in three types — two with V-type handle which allows the operation from the outside and other with the operating handle of the breaker extending from it to allow it to be directly switched ON or OFF from outside the enclosure. Enclosures with V-type handles are provided with a door interlocking mechanism which prevents the door from being opened in the ON condition. Knockout holes for wiring use are provided as shown in the diagram. Standard Dustproof AF96-175 Rainproof CP97-2636 n Ordering information Specify the following: Type number of enclosures n Type of enclosures MCCB Enclosure Standard * With V-type handle Dustproof * Rainproof * BW32 BW50 BW63 BZ6C10C2 * BZ6C10C3 BW9UVBA-3A * BW9UWBA-3A * BW100 BZ6C25C2 * BZ6C25C3 * BW9UVBA-3B * BW9UWBA-3B * BW125 BW9UCCA-2 BW9UCCA-3 BW9UVCA-3 BW9UWCA-3 BW250 BW9UCGA-3 BW9UVGA-3 BW9UWGA-3 BW400 BZ-C60B BW9UVHA-3 BW9UWHA-3 BW630 BW800 BZ-C70B BW9UVJA-3 – *1 No models are available for four-pole products. *2 The appearance of dust-proof and rain-proof models differs from the photograph (400A frames and higher). *3 Combination with external accessories(R) is not possible.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Fig.1 Standard Fig.2 With V type handle BW9UVBA-3A, BW9UVBA-3B BW9UVCA-3, BW9UVGA-3 Fig3. With V type handle BW9UVHA-3, BW9UVJA-3 n Dimensions, mm n Connection method diagrams CL CL MCCB E A J R3.5(ø7) R6.5(ø13) C Mounting hole Neutral terminal (Special order) øL lead hole Earth terminal H J G F B E F B A OFF TRIP ON RESET Mounting hole P C D 4-L lead hole Earth terminal M6 2-K lead hole G H CL CL 2-K lead hole 4-L lead holeH Earth terminal M6G Mounting hole P F B A E D C LINE LINE LOAD LOAD a b LINELOAD c Type Connection Fig. A B C D E F G H J K L P BZ6C10C2 a, b, c 1 135 225 95 – 90 170 65 40 25 – ø35, ø22 – BZ6C10C3 BZ6C25C2 200 320 95 – 120 240 80 40 25 – ø45, ø30 – BZ6C25C3 BW9UCCA-2 200 320 103 – 120 240 80 40 25 – ø45, ø30 – BW9UCCA-3 BW9UCGA-3 360 280 45 ø55, ø40 BZ-C60B 400 750 175 – 300 650 200 80 100 – ø106, ø78, ø63 – BZ-C70B BW9UVBA-3A 2 180 300 114 178.5 100 220 70 40 – – ø28, ø35, ø43 ø7 BW9UVBA-3B 250 400 142 206.5 170 320 110 50 – ø23 ø35, ø52, ø63 ø9 BW9UVCA-3 207 BW9UVGA-3 BW9UVHA-3 3 400 750 206 269 300 650 200 80 – ø28 ø63, ø78, ø106 ø12 BW9UVJA-3
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Type No. of poles MCCB Dimensions (mm) Packing quantity Appearance Transparent Gray A B C BW9BTAA-L2 BW9BTAA-L2W 2 BW32 -2P BW50 -2P BW63 -2P BW100 -2P 50 40 53 2 • Preventing exposure of live section when amplifier's terminals are connected
- Snap-on mounting BW9BTAA-L3 BW9BTAA-L3W 2, 3 BW32 -3P BW50 -3P BW63 -3P BW100 -3P 75 40 53 2 BW9BTCA-L2 BW9BTCA-L2W 2 BW125JAG-2P 60 40 66.5 2 BW9BTCA-L3 BW9BTCA-L3W 2, 3 BW50HAG-2P BW50HAG-3P BW125RAG-2P BW125HAG-2P BW125 -3P 90 40 66.5 2 BW9BTCA-C3 – 2, 3 BW125RAG-2P BW125 -3P 90 60 66.5 2 BW9BTCA-L4 BW9BTCA-L4W 4 BW125JAG-4P BW125RAG-4P 120 40 66.5 2 BW9BTGA-L3 * BW9BTGA-L3W * 2, 3 BW160 -2P BW160 -3P 105 50 66.5 2 BW9BTGA-L4 * BW9BTGA-L4W * 4 BW160 -4P 140 50 66.5 2 BW9BTGA-C3 – 2, 3 BW250 -2P BW250 -3P 105 75 66.5 2 BW9BTGA-L3 * BW9BTGA-L3W * 2, 3 BW250 -2P BW250 -3P 105 50 66.5 2 BW9BTGA-L4 * BW9BTGA-L4W * 4 BW250 -4P 140 50 66.5 2 BW9BTHA-L3 * BW9BTHA-L3W * 2, 3 BW400 -2P BW400 -3P 172 110 98 2 BW9BTHA-L4 * – 4 BW400 -4P 220 110 98 2 BW9BTJA-L3 BW9BTJA-L3W 3 BW630 -3P BW800 -3P 230 135 97.5 2 BW9BTJA-L4 BW9BTJA-L4W 4 BW630 -4P BW800 -4P 280 155 98 2 Terminal covers n Description These terminal covers are used as guards to prevent accidental touch with live line terminations. These terminal covers can be fitted to either line or load side. l Up to 400AF Short type: BW9BT A-S
- Snap-on fitting Long type: BW9BT A-L
- Crimp connection use l 630, 800AF Long type: BW9BTJA-L
- Transparent Short type Long type Long type MCCB C B A
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Type No. of poles MCCB Dimensions (mm) Packing quantity Appearance Transparent Gray A B C BW9BTAA-S2 BW9BTAA-S2W 2 BW32 -2P BW50 -2P BW63 -2P BW100 -2P 50 10 53 2 • Preventing exposure of live section when amplifier's terminals are connected
- Snap-on mounting BW9BTAA-S3 BW9BTAA-S3W 2, 3 BW32 -3P BW50 -3P BW63 -3P BW100 -3P 75 10 53 2 BW9BTCA-S2P20 BW9BTCA-S2WP20 2 BW125JAG-2P 60 8 66.5 2 BW9BTCA-S3P20 BW9BTCA-S3WP20 2, 3 BW50HAG-2P BW50HAG-3P BW125RAG-2P BW125HAG-2P BW125 -3P 90 8 66.5 2 BW9BTCA-S4P20 BW9BTCA-S4WP20 4 BW125JAG-4P BW125RAG-4P 120 8 66.5 2 BW9BTGA-S3P20 * BW9BTGA-S3WP20 * 2, 3 BW160 -2P BW160 -3P BW250 -2P BW250 -3P 105 8 66.5 2 BW9BTGA-S4P20 * BW9BTGA-S4WP20 *
4 BW160 -4P
140 8 66.5 2 BW9BTHA-S3 * BW9BTHA-S3W * 2, 3 BW400 -2P BW400 -3P 140 65 98 2 BW9BTHA-S4 * BW9BTHA-S4W *
4 BW400 -4P 185 65 98 2
C B A Notes: • A gray-white terminal cover comes standard with the Global Series 125AF and 250AF . When using the external operating handle, part of the terminal cover ( ) must be cut away. Crimp terminals for 325 mm are not available. This type of cover can be mounted on the 400AF when flat terminals are not used.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Insulation barriers n Description The interphase barriers are provided on frame size of 32AF to 800AF breakers for front mounting. The barriers are installed in the molded slots between terminals. The earth barrier is used to increase the insulation with the mounting plate surface when two crimp terminals are wired. Installation of these barriers after wiring is possible even when an external accessory is installed. Interphase barrier Earth barrier Interphase barrier MCCB Interphase barrier Type Dimensions (mm) Packing quantity Mass (g)A B BW32 BW50AAG, EAG BW50SAG, RAG BW63 BW100 BZ6B10C 50 49 4 23 BW50HAG, BW125 BW9BPCA 50 60 2 15 BW160 BW250 BW9BPGA 80 60 2 25 BW400 BW630 BW800 B-43A 105 95 4 130 Earth barrier MCCB Earth barrier Type Dimensions (mm) Packing quantity Mass (g)A B BW32 -2P BW50 -2P BW63 -2P BW100 -2P BZ6BL10C2 100 (50, 75)* (30)* 1 33 BW32 -3P BW50 -3P BW63 -3P BW100 -3P BZ6BL10C3 125 (75, 100)* (30)* 1 41 Interphase barrier A B Breaker Breaker B A Earth barrier Note: * Can be cut to dimensions
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Padlocking device
- Cap type Q1 Q1: BZ6L10CA (OFF-locking Padlocking device) Padlocking device
- Cap type Q1,QN
- Plate type Q2 Padlocking device and handle locking cover n Description
- Padlocking device These padlocking device lock the Breaker handle in the OFF position. Use a commercially available padlock with a shackle diameter of 3.5 to 5mm (5mm for the BZ6L10CA).
- Handle locking covers (Order Separately) These simple handle locking covers can be easily installed by the user. Tripping is possible while the Breaker is locked ON. Handle locking cover Handle locking cover MCCB Padlocking device Handle locking cover Q1: Cap type QN: Scissors type Q2: Plate type BW32 BZ6L10CA – ▲ * BZ6L10C BW50AAG, EAG, SAG, RAG BW63 BW100 BW50HAG, BW125 BW9Q1CA * BW9Q2CA * BW9L1CA BW160 BW9Q2GA BW250 BW400 ▲ BW9QNHA * BW9Q2HA BW9L1HA BW630 BW9Q2JA BW800 Molded Case Circuit Breakers G-TWIN series External accessories Notes: Specify Locks when ordering the Breaker. (▲: Factory-mounted) ON and OFF locking is possible. Not applicable to the BW125JA -2P (models with a width of 60 mm). If a padlock is required, use a commercially available padlock with the dimensions shown in the diagram at the right. Three padlocks with shackles from 3.5 to 8 mm in diameter can be attached. (20) 9.5 CL CL MCCB 21.8 3.5 7.8 3.5 ø3.5 OFF 3-ø4.5 29.5 6 6 Padlock Padlock (Obtain a commercially available lock conforming to the diagram at the right.)