EDS1138-002 EUROPA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
This document must be retained for future reference. It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should also be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europacomponents.com www.europa-plc.com Data Sheet EDS1138-002 Page 1 of 4 EUR PA (DOL) Motor Starter With Isolator Instructions for Direct-On-Line The Direct On Line Motor Starter (DOL) is designed to switch a single or three phase induction motor at rated voltage. It compromises of an isolator, steel enclosure, a contactor, start contact. link wires and stop / start buttons. The thermal overload is supplied as a separate item. Various factors should be considered when selecting the correct DOL. The size of unit is dictated by the motor that is being supplied and can be selected using the table below. Enclosure Type Coil Voltage Current Rating Max Motor Size Approx. kW @ 415V Part No. Steel 240V 12 Amps AC3 5.5kW BE2-D123U7 Steel 415V 12 Amps AC3 5.5kW BE2-D123N7 Steel 240V 25 Amps AC3 11kW BE2-D253U7 Steel 415V 25 Amps AC3 11kW BE2-D253N7 Note: The current on the motor rating plate should not exceed the rating of the DOL. For example: 1. 2.2kW motor with FLC of 5 Amps @ 415Volts to be mounted in a protected position in a light commercial application will require a LE1-D123N7. 2. Similarly a 7.5kW motor with FLC of 12Amps@ 415Volts will require the next size of DOL, namely LE1-D253N7. Having selected the DOL for the motor size, a suitable thermal overload now needs to be chosen to match the motor rating. The full load current (FLC) of the motor is shown on the motor rating plate This should be used to select an overload so that this current falls within the rating of the chosen overload. For example: Overload Part Number Relay Range Useable with 12A DOL Useable with 25A DOL TR2-D09301 0.1-0.16A TR2-D09302 0.16-0.25A TR2-D09303 0.25-0.40A TR2-D09304 0.40-0.63A TR2-D09305 0.63-1.00A TR2-D09306 1.00-1.65A TR2-D09307 1.60-2.50A TR2-D09308 2.5-4.00A TR2-D09310 4.00-6.00A TR2-D09312 5.50-8.00A TR2-D09314 7.00-10.0A TR2-D12316 9.00-13.0A TR2-D18321 12.0-18.0A - TR2-D25322 17.0-25.0A - Cable Type Contactor Type TC1-D09 TC1-D12 TC1-D18 TC1-D25 Stranded 2 x 1mm Min 2 x 1mm Min 2 x 1.5mm Min 2 x 1.5mm Min 2 x 4mm Max 2 x 4mm Max 2 x 6mm Max 2 x 6mm Max - - - 1 x 10mm Max Stranded with Ferrule 2 x 1mm Min 2 x 1mm Min 2 x 1mm Min 2 x 1mm Min 2 x 2.5mm Max 2 x 2.5mm Max 2 x 4mm Max 2 x 4mm Max 1 x 4mm Max 1 x 4mm Max 1 x 6mm Max 1 x 6mm Max Solid without Ferrule 2 x 1mm Min 2 x 1mm Min 2 x 1.5mm Min 2 x 1.5mm Min 2 x 4mm Max 2 x 4mm Max 2 x 6mm Max 2 x 6mm Max - 1 x 6mm Max 1 x 6mm Max
Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europacomponents.com www.europa-plc.com Data Sheet EDS1138-002 Page 2 of 4 EUR PA (DOL) Motor Starter With Isolator Instructions for Direct-On-Line Wiring of the Direct-On-Line (DOL) Motor Starter with Isolator 1) Three Phase Supply 240Volt Coil - see wiring diagram .The following links are pre-fitted to the starter; 13 - 17 with a flying lead to be connected to Overload terminal 95; A2 - 14 - 18. All other control and power connections have to be made by the installer. 2) Three Phase supply 415 Volt Coil - see wiring diagram .The following links are pre-fitted to the starter; 13 - 17 with a flying lead to be connected to Overload terminal 95; A2 - 14 - 18; Contactor terminal 1 - A1; Contactor terminal 5 via flying lead to Overload terminal 96. All other control and power connections have to be made by the installer. 3) Single Phase supply 240 Volt Coil - see wiring diagram<?> .The following links are pre-fitted to the starter; 13 - 17 with a flying lead to be connected to Overload terminal 95; A2 - 14 - 18; Contactor terminal 5 - A1; Contactor terminal 5 via flying lead to Overload terminal 96. All other control and power connections have to be made by the installer.
Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europacomponents.com www.europa-plc.com Data Sheet EDS1138-002 Page 3 of 4 EUR PA (DOL) Motor Starter With Isolator Instructions for Direct-On-Line Wiring of additional start stop devices on DOL devices for 400V 3 Phase with 240V coil Move pins left or right to fit different contactors Note: The copper pins of the overload relay need to be correctly positioned to suit the contactor that it is to be mounted to.
Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europacomponents.com www.europa-plc.com Data Sheet EDS1138-002 Page 4 of 4 EUR PA (DOL) Motor Starter With Isolator Instructions for Direct-On-Line