BAT54 INFINEON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 14
Technical content
BAT54... Silicon Schottky Diodes
- For low-loss, fast-recovery, meter protection, bias isolation and clamping application
- Guard ring protected
- Low forward voltage
- Pb-free (RoHS compliant) package1)
- Qualified according AEC Q101 BAT54-02LRH BAT54-02V BAT54-03W BAT54-04 BAT54-04W BAT54-05 BAT54-05W BAT54-06 BAT54-06W BAT54 BAT54W /G31 /G32 /G33 /G31 /G44 /G32 /G32 /G44 /G31 /G33 /G31 /G44 /G32 /G32 /G44 /G31 /G33 /G31 /G44 /G32 /G32 /G44 /G31 /G33 /G31 /G32 Type Package Configuration LS(nH) Marking BAT54 BAT54-02LRH BAT54-02V BAT54-03W* BAT54-04 BAT54-04W BAT54-05 BAT54-05W BAT54-06 BAT54-06W BAT54W SOT23 TSLP-2-7 SC79 SOD323 SOT23 SOT323 SOT23 SOT323 SOT23 SOT323 SOT323 single single single single series series common cathode common cathode common anode common anode single 1.8 0.4 0.6 1.8 1.8 1.4 1.8 1.4 1.8 1.4 1.4 T b 5/blue TS TS TC TC TA TA * Preliminary data 1Pb-containing package may be available upon special request
BAT54... Maximum Ratings at TA = 25°C, unless otherwise specified Parameter Symbol Value Unit Diode reverse voltage VR 30 V Forward current IF 200 mA Non-repetitive peak surge forward current (t ≤ 10 ms) IFSM 600 Repetitive peak forward current1) tp ≤ 1 s, δ = 0.5 IFRM 300 mA Total power dissipation BAT54, TS ≤ 94 °C BAT54-02LRH, TS ≤ 135 °C BAT54-02V, TS ≤ 126 °C BAT54-03W, TS ≤ tbd °C BAT54-04, TS ≤ 71 °C BAT54-04W, TS ≤ 117 °C BAT54-05, TS ≤ 48 °C BAT54-05W, TS ≤ 110 °C BAT54-06, TS ≤ 71 °C BAT54-06W, TS ≤ 117 °C BAT54W, TS ≤ 125 °C Ptot 230 230 230 230 230 230 230 230 230 230 230 mW Junction temperature Tj 150 °C Storage temperature Tstg -65 ... 150 1Device mounted on epoxy PCB 40 x 40 x 1.5 mm / 6 cm² Cu
BAT54... Thermal Resistance Parameter Symbol Value Unit Junction - soldering point1) BAT54 BAT54-02LRH BAT54-02V BAT54-03W BAT54-04 BAT54-04W BAT54-05 BAT54-05W BAT54-06 BAT54-06W BAT54W RthJS ≤ 245 ≤ 65 ≤ 105 ≤ tbd ≤ 345 ≤ 145 ≤ 445 ≤ 175 ≤ 345 ≤ 145 ≤ 110 K/W Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. DC Characteristics Breakdown voltage2) I(BR) = 10 µA V(BR) 30 - - V Reverse current2) VR = 25 V IR - - 2 µA Forward voltage2) IF = 0.1 mA IF = 1 mA IF = 10 mA IF = 30 mA IF = 100 mA VF 240 320 400 500 800 mV 1For calculation of RthJA please refer to Application Note Thermal Resistance 2Pulsed test: tp = 300 µs; D = 0.01
BAT54... Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. AC Characteristics Diode capacitance V R = 1 V, f = 1 MHz CT - - 10 pF Reverse recovery time IF = 10 mA, IR = 10 mA, measured IR = 1 mA , RL = 100 Ω trr - - 5 ns
BAT54... Diode capacitance CT = ƒ (VR) f = 1MHz 0 5 10 15 20 V 30 VR pF CT Reverse current IR = ƒ (TA) VR = Parameter 25 50 75 °C 125 TA -1 10 0 10 1 10 2 10 3 10 µA IR IR(5V) IR(25V) Reverse current IR = ƒ(VR) TA = Parameter 0 5 10 15 20 V 30 VR -1 10 0 10 1 10 2 10 3 10 µA IR 125°C 85°C 25°C Forward Voltage VF = ƒ (TA) IF = Parameter -50 -25 0 25 50 75 °C 125 TA 0.1 0.2 0.3 V 0.5 VF 0.1mA 1mA 10mA 30mA
BAT54... Forward current IF = ƒ (VF) TA = Parameter VF -5 10 -4 10 -3 10 -2 10 -1 10 0 10 A IF 125°C 85°C 25°C - 40°C Forward current IF = ƒ (TS) BAT54 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF Forward current IF = ƒ (TS) BAT54-02LRH 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF Forward current IF = ƒ (TS) BAT54-02V 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF
BAT54... Forward current IF = ƒ (TS) BAT54-04 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF Forward current IF = ƒ (TS) BAT54-04W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF Forward current IF = ƒ (TS) BAT54-05 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF Forward current IF = ƒ (TS) BAT54-05W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF
BAT54... Forward current IF = ƒ (TS) BAT54-06 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF Forward current IF = ƒ (TS) BAT54-06W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF Forward current IF = ƒ (TS) BAT54W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 120 140 160 180 mA 220 IF
BAT54...Package SC79 Package Outline Foot Print Marking Layout (Example) Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø180 mm = 8.000 Pieces/Reel (2 mm Pitch) Reel ø330 mm = 10.000 Pieces/Reel ±0.11.6 0.3 marking Cathode 0.8 ±0.1 10˚MAX. ±0.11.2 A ±0.05 10˚MAX. 0.13 A0.2 M +0.05 -0.03 ±0.040.55 ±0.050.2 0.35 0.35 1.35 BAR63-02V Type code Cathode marking Laser marking 0.66 0.93 0.4 1.33 1.96 0.2 Cathode marking Cathode marking Standard Reel with 2 mm Pitch 2005, June Date code
BAT54... Date Code marking for discrete packages with one digit (SCD80, SC79, SC75 1) ) CES-Code 1) New Marking Layout for SC75, implemented at October 2005. Month 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 201 3 2014 0 1 apAPapAPapAP 0 2 bqB Q bqB Q bqB Q 0 3 crC R crC R crC R 0 4 d sDSd sDSd sDS 0 5 e t ETe t ETe t ET 0 6 fuF U fuF U fuF U 0 7 gvG VgvG VgvG V 0 8 h xHXh xHXh xHX 0 9 jyJ Y jyJ Y jyJ Y 1 0 k zKZk zKZk zKZ 1 1 l 2L4 l 2L4 l 2L4 1 2 n3N5n3N5n3N5
BAT54...Package SOT23 Package Outline Foot Print Marking Layout (Example) Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel EH s BCW66 Type code Pin 1 0.8 0.9 0.91.3 0.8 1.2
0.25 M BC
1.9 -0.05 +0.10.4 ±0.12.9 0.95 C B 0...8˚ 0.2 A 0.1 MAX. 1.3 ±0.1 10˚ MAX. M 2.4 ±0.15 ±0.11 A 0.15 MIN. 1) Lead width can be 0.6 max. in dambar area 3.15 2.65 2.13 0.9 0.2 1.15Pin 1 Manufacturer 2005, June Date code (YM)
BAT54...Package SOT323 Package Outline Foot Print Marking Layout (Example) Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel 1.25 ±0.1 0.1 MAX. 2.1±0.1 0.15 +0.1 -0.05 0.3+0.1 ±0.10.9 A ±0.22 -0.05 0.650.65 M 0.1 0.1 MIN. 0.1 M0.2 A 0.24 2.15 1.1 2.3 Pin 1 Pin 1 2005, June Date code (YM) BCR108W Type code 0.6 0.8 1.6 0.65 0.65 Manufacturer
BAT54...Package TSLP-2-7 ±0.050.6 ±0.050.65 ±0.0350.25 1) 1±0.05 0.05 MAX. +0.010.39-0.03 1) Dimension applies to plated terminal Cathode marking 1)±0.0350.5 Bottom viewTop view Package Outline Foot Print Marking Layout (Example) Standard Packing Reel ø180 mm = 15.000 Pieces/Reel Reel ø330 mm = 50.000 Pieces/Reel (optional) For board assembly information please refer to Infineon website "Packages" 0.45 0.275 0.275 0.375 0.925 Copper Solder mask Stencil apertures 0.35 0.6 0.35 0.3 0.76 1.16 0.5 Cathode marking BAR90-02LRH Type code Cathode marking Laser marking
BAT54... Edition 2006-02-01 Published by Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007. All Rights Reserved. Attention please! The information given in this dokument shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office (www.infineon.com). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.