BAS40.../BAS140W Silicon Schottky Diode

  • General-purpose diode for high-speed switching
  • Circuit protection
  • Voltage clamping
  • High-level detecting and mixing
  • Pb-free (RoHS compliant) package
  • Qualified according AEC Q1011) BAS40-06 BAS40-06W BAS40-05 BAS40-05W BAS40 BAS40-04BAS140W BAS40-02L /G33 /G31 /G32 /G31 /G32 /G33 /G31 /G44 /G32 /G32 /G44 /G31 /G33 /G31 /G44 /G32 /G32 /G44 /G31 /G33 /G31 /G44 /G32 /G32 /G44 /G31 BAS40-07 BAS40-07W /G31 /G44 /G32 /G32 /G33 /G34 /G44 /G31 ESD (Electrostatic discharge) sensitive device, observe handling precaution! Type Package Configuration Marking BAS140W BAS40 BAS40-02L* BAS40-04 BAS40-05 BAS40-05W BAS40-06 BAS40-06W BAS40-07 BAS40-07W SOD323 SOT23 TSLP-2-1 SOT23 SOT23 SOT323 SOT23 SOT323 SOT143 SOT343 single single single, leadless series common cathode common cathode common anode common anode parallel pair parallel pair white 4 43s FF 44s 45s 45s 46s 46s 47s 47s 1* BAS40-02L is not qualified according AEC Q101

BAS40.../BAS140W Maximum Ratings at TA = 25 °C, unless otherwise specified Parameter Symbol Value Unit Diode reverse voltage VR 40 V Forward current IF 120 mA Non-repetitive peak surge forward current t ≤ 10ms IFSM 200 Total power dissipation BAS140W, TS ≤ 113°C BAS40, BAS40-07, TS ≤ 81°C BAS40-02L, TS ≤ 127°C BAS40-04, BAS40-06, TS ≤ 56°C BAS40-06W, TS ≤ 106°C BAS40-05, TS ≤ 31°C BAS40-05W, TS ≤ 98°C BAS40-07W, TS ≤ 118°C Ptot 250 250 250 250 250 250 250 250 mW Junction temperature Tj 150 °C Operating temperature range Top -55 ...150 Storage temperature Tstg -55 ...150 Thermal Resistance Parameter Symbol Value Unit Junction - soldering point1) BAS140W BAS40, BAS40-07 BAS40-02L BAS40-04, BAS40-06 BAS40-06W BAS40-05 BAS40-05W BAS40-07W RthJS ≤ 150 ≤ 275 ≤ 90 ≤ 375 ≤ 175 ≤ 475 ≤ 205 ≤ 125 K/W 1For calculation of RthJA please refer to Application Note AN077 (Thermal Resistance Calculation)

BAS40.../BAS140W Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. DC Characteristics Breakdown voltage I(BR) = 10 µA V(BR) 40 - - V Reverse current VR = 30 V IR - - 1 µA Forward voltage IF = 1 mA IF = 10 mA IF = 40 mA VF 250 350 600 310 450 720 380 500 1000 mV Forward voltage matching1) IF = 10 mA ∆ VF - - 20 AC Characteristics Diode capacitance VR = 0 , f = 1 MHz CT - 3 5 pF Differential forward resistance IF = 10 mA, f = 10 kHz RF - 10 - Ω Charge carrier life time IF = 25 mA τ rr - - 100 ps 1∆VF is the difference between lowest and highest VF in a multiple diode component.

BAS40.../BAS140W Diode capacitance CT = ƒ (VR) f = 1MHz EHB00040BAS 40... C VR T pF 10 20 V 30 Forward resistance rf = ƒ (IF) f = 10 kHz 0.1 EHB00041BAS 40... r Ι f 1 10 mA 100 F Ω 210 110 10 3 10 3 Reverse current IR = ƒ (TA) VR = Parameter 0 25 50 75 100 °C 150 TA -8 10 -7 10 -6 10 -5 10 -4 10 A IR VR = 40V 30V 20V 10V Reverse current IR = ƒ(VR) TA = Parameter EHB00039BAS 40... Ι VR R 100 -210 110 210 310 A 10-1 10 20 30 V 40 TA = 150 C 85 C 25 C µ

BAS40.../BAS140W Forward Voltage VF = ƒ (TA) IF = Parameter -50 -25 0 25 50 75 100 °C 150 TA 0.1 0.2 0.3 0.4 0.5 0.6 V 0.8 VF IF = 40 mA 10 mA 1 mA 0.1 mA 10 µA 1 µA Forward current IF = ƒ (VF) TA = Parameter 0.0 EHB00038BAS 40... Ι VF F 0.5 1.0 V 1.5 TA = -40 ˚C 25 ˚C 85 ˚C 150 ˚C -210 -110 mA 010 10 1 210 Forward current IF = ƒ (TS) BAS140W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF Forward current IF = ƒ (TS) BAS40, BAS40-07 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF

BAS40.../BAS140W Forward current IF = ƒ (TS) BAS40-02L 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF Forward current IF = ƒ (TS) BAS40-06W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF Forward current IF = ƒ (TS) BAS40-04, BAS40-06 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF Forward current IF = ƒ (TS) BAS40-05 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF

BAS40.../BAS140W Forward current IF = ƒ (TS) BAS40-05W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF Forward current IF = ƒ (TS) BAS40-07W 0 15 30 45 60 75 90 105 120 °C 150 TS 100 mA 140 IF Permissible Puls Load RthJS = ƒ (tp) BAS140W t EHD07165 p 10 -6 10 -5 10 -4 10 -3 10 -2 s1 0 0 T t p D = t p T 10 0 110 210 D = 0.5 0.2 0.1 0.05 0.02 0.01 0.005 R thJS K/W BAS 140W Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAS140W t EHD07166 p F 10 -6 10 -5 10 -4 10 -3 10 -2 s1 0 0 T t p D = t p T D = 0.005 0.01 0.02 0.05 0.1 0.2 0.5 Ι max DCΙ F 210 10 1 010 BAS 140W

BAS40.../BAS140W Permissible Puls Load RthJS = ƒ (tp) BAS40-02L 10 -6 10 -5 10 -4 10 -3 10 -2 10 -1 10 1 s tp 0 10 1 10 2 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAS40-02L 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 Permissible Puls Load RthJS = ƒ (tp) BAS40-06W 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 2 10 3 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAS40-06W 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 2 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5

BAS40.../BAS140W Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAS40-05W 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 2 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 Permissible Puls Load RthJS = ƒ (tp) BAS40-05W 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 2 10 3 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0

BAS40.../BAS140WPackage SOD323

BAS40.../BAS140WPackage SOT143 Package Outline Foot Print Marking Layout (Example) Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel RF s 2005, June Date code (YM) BFP181 Type code Pin 1 0.8 0.81.2 0.9 1.1 0.9 1.2 0.8 0.8 0.8 -0.05 +0.1 1.9 1.7 ±0.12.9 +0.1 -0.050.4 0.1 MAX.

0.25 M B

±0.11 10˚ MAX. 0.15 MIN. 0.2 AM 2.4 ±0.15 0.2 10˚ MAX.A 1.3 ±0.1 0...8˚ 2.6 3.15Pin 1 0.2 1.15 B Manufacturer

BAS40.../BAS140WPackage SOT23 Package Outline Foot Print Marking Layout (Example) Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel EH s BCW66 Type code Pin 1 0.8 0.9 0.91.3 0.8 1.2

0.25 M BC

1.9 -0.05 +0.10.4 ±0.12.9 0.95 C B 0...8˚ 0.2 A 0.1 MAX. 1.3 ±0.1 10˚ MAX. M 2.4 ±0.15 ±0.11 A 0.15 MIN. 1) Lead width can be 0.6 max. in dambar area 3.15 2.65 2.13 0.9 0.2 1.15Pin 1 Manufacturer 2005, June Date code (YM)

BAS40.../BAS140WPackage SOT323 Package Outline Foot Print Marking Layout (Example) Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel 1.25 ±0.1 0.1 MAX. 2.1±0.1 0.15 +0.1 -0.05 0.3+0.1 ±0.10.9 A ±0.22 -0.05 0.650.65 M 0.1 0.1 MIN. 0.1 M0.2 A 0.24 2.15 1.1 2.3 Pin 1 Pin 1 2005, June Date code (YM) BCR108W Type code 0.6 0.8 1.6 0.65 0.65 Manufacturer

BAS40.../BAS140WPackage TSLP-2-1

BAS40.../BAS140W Edition 2009-11-16 Published by Infineon Technologies AG

81726 Munich, Germany

 2009 Infineon Technologies AG All Rights Reserved. Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (<www.infineon.com >). Warnings Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.