B116LP SYSTEMSENSOR | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

B116LP Plug-in Detector Base For use with the following smoke detectors: In US: 11 51, 2151 In Canada: 1151A, 2151A In Europe: 1151E, 2151E INSTALLATION AND MAINTENANCE INSTRUCTIONS

3825 Ohio Avenue,

St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 Before Installing Please thoroughly read the System Sensor manual I56-407, Guide for Proper Use of System Smoke Detectors, which pro- vides detailed information on detector spacing, placement, zoning, wiring, and special applications. Copies of this manual are available at no charge from System Sensor. (For installation in Canada, please refer to CAN4-S524, Standard for the Installation of Fire Alarm Systems and CEC Part 1, Sec. 32.) NOTICE: This manual should be left with the owner/user of this equipment. IMPORTANT: The detector used with this base must be Specifications Base Diameter: 6.2 inches (157 mm) Base Height: 0.95 inches (24 mm) Weight: 0.3 lb. (130 g) Mounting: 4-inch square box with or without plaster ring. Min. Depth–1.5 inches 4-inch octagon box. Min. Depth–1.5 inches 3-1/2 inch-octagon box. Min. Depth–1.5 inches 50 mm box 60 mm box 70 mm box Operating Temperature Range: 0° to +49°C (32° to 120°F) US and Canadian Installations 10°t o 60°C (14° to 140°F) European Installations Operating Humidity Range: 10% to 93% Relative Humidity Electrical Ratings – includes base and detector System Voltage: 24 VDC Maximum Ripple Voltage: 4 Volts peak to peak Start-up Capacitance: 0.02 µF Maximum Standby Ratings: 15 VDC Minimum

35 VDC Maximum

µA Maximum Alarm Ratings: 8 V Minimum at 16 mA

12 V Maximum at 100 mA

(Alarm current MUST be limited to 100 mA maximum by the control panel.) Relay Contact Ratings: Resistive or Inductive (60% power factor) Load Form C:* 2.0A @ 30 V AC/DC 0.6A @ 110 VDC 1.0A @ 125 V AC Reset Voltage: 1.4 VDC Minimum Reset Time: 0.3 Seconds Maximum Start-up Time: 34.0 Seconds Maximum *For Canadian installations relay contact ratings are 2.0A @ 30 V AC/DC. tested and maintained regularly following NFPA 72 require- ments. The detector used with this base should be cleaned at least once a year. General Description The model B116LP plug-in detector base is used with System Sensor model 1151, 1151A, and 1151E ionization detector heads and model 2151, 2151A, and 2151E photo- electronic detector heads. The capability of plugging these detectors into a variety of special bases makes them more versatile than equivalent direct-wired models. Refer to the System Sensor catalog for other available plug-in detector bases.

system control panel in the alarm state. snaps in place (see Figure 1). tem from responding properly in the event of a fire. panel being used before wiring the detector loops. system supervision of connections. through 5, and to terminals 12 through 14, respectively. available from System Sensor upon request. Figure 1. Mounting base to box:

turned into the base, completing the circuit. prevents removal of the detector without the use of a tool. Figure 2. Typical wiring diagram:

14 COM CONTACT

prevents using the feature again.

© 2001 System Sensor Three-Year Limited Warranty System Sensor warrants its enclosed smoke detector base to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for this smoke detector base. No agent, represen- tative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the repair or replacement of any part of the smoke detector base which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Repair Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequen- tial or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limita- tion or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Please refer to insert for the Limitations of Fire Alarm Systems