v4-01 • 2022-Jun-08
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 2 Content Guide 9 Package Drawings & Markings ... 40
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 3
1 General Description
The AS8579 is a capacitive sensor that detects the change of capacity in different applications. The capacitive sensor measures the relative change of the impedance (RealCapSense, due to our measurement principle), dependent on the circuit. This can be used for human being detection as well as many other applications The IC capture the current of a metal object and applies algorithms to determine the capacitive and resistive information (Impedance). This information can be read via SPI Interface that can be also used for IC configuration. This high precision performance sensor also supports a multitude of diagnostic features that meet standard functional safety requirements up to ASIL B. The capacitive sensing IC is specifically designed to work under high electromagnetic disturbances (EMC). With this approach, the sensor can distinguish in a hands-on application if for example, a steering wheel is touched or not. The AS8579 is available in an SSOP24 package and operates at a supply voltage of 5 V.
1.1 Key Benefits & Features
The benefits and features of AS8579, Capacitive Sensor, are listed below: Figure 1: Added Value of Using AS8579 Benefits Features Accurate capacitive measurement(including resistive information) I/Q-signal demodulation Higher durability and lower system costs VAR_SEN & FIX_SEN function to avoid parasitic influences from cable and PCB Enabler for safety critical applications Processed according functional safety standard Suitable for automotive applications AEC-Q100 Grade 1 qualified
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 4
1.2 Applications
- Autonomous driving applications e.g.: Hands on steering wheel detection
- Detection of any human presence inside a vehicle
- Detection of any human presence exterior of vehicles e.g.: Automatic trunk opener (trunk opens automatically and touch-less by detection of human foot near the sensor only)
1.3 Block Diagram
The functional blocks of this device are shown below: Figure 2 : Functional Blocks of AS8579
Ordering Information
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 5
2 Ordering Information
Ordering Code Package Marking Delivery Form Delivery Quantity AS8579-ASST SSOP24 AS8579 Tape & Reel 2000 pcs/reel AS8579-ASSM SSOP24 AS8579 Tape & Reel 500 pcs/reel
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 6
3 Pin Assignment
3.1 Pin Diagram
Figure 3: AS8579 Pin Assignment AS8579
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 7
3.2 Pin Description
Figure 4: Pin Description of AS8579 (SSOP24 package) Pin Number Pin Name Pin Type(1) Description
1 SEN9 AIO 0 Ohm Sensor Line 9
2 SEN8 AIO 0 Ohm Sensor Line 8
3 SEN7 AIO 0 Ohm Sensor Line 7
4 SEN6 AIO 0 Ohm Sensor Line 6
5 SEN5 AIO 0 Ohm Sensor Line 5
6 SEN4 AIO 0 Ohm Sensor Line 4
7 SEN3 AIO 0 Ohm Sensor Line 3
8 SEN2 AIO 0 Ohm Sensor Line 2
9 SEN1 AIO 0 Ohm Sensor Line 1
10 SEN0 AIO 0 Ohm Sensor Line 0
11 VAR_SEN(2) AIO 0 Ohm Cable Shielding Driver
12 FIX_SEN(3) AIO 0 Ohm PCB Shielding Driver
13 CLK _E DI_PD System Clock
14 TEST Factory Test Pin connect to
15 CS DI_PD SPI Chip Select (active
high)
16 MOSI DI_PD SPI Data in
17 SCLK DI_PD SPI Clock
18 VDD S External 5 V Supply
19 VDD S External 5 V Supply
20 MISO DO SPI Data out
21 GND S Ground
22 GND S Ground
23 VREG S Internal 3.45 V Supply
24 VREG2 S Connect to VREG
(1) Explanation of abbreviations: AIO 0Ohm Analog Input/Output DI_PD Digital Input with internal pull-down (see Electrical Characteristics) DO Digital Output S Supply (2) VAR_SEN optionally connected to cable shielding to avoid parasitic capacitance influences from the shielding (3) FIX_SEN optionally connected to PCB shield layer to avoid parasitic capacitance influences from PCB shield layer
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 8
4 Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only. Functional operation of the device at these or any other conditions beyond those indicated under “Operating Conditions” is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Figure 5 Symbol Parameter Min Max Unit Comments Electrical Parameters VDD DC Supply Voltage at VDD Pin -0.3 7 V Non operational VDC_ON DC Voltage at Digital IO Pins -0.3 VDD+0.3 V VDC_SEN Sensor Analog Pins (SENx, VAR_SEN) -0.3 20 V ISCR Input Current (latch-up immunity) ±100 mA AEC-Q100-004 Electrostatic Discharge ESD_HBM Electrostatic Discharge HBM ±2 kV AEC-Q100-002 ESD_MM Electrostatic Discharge MM ±100 V AEC-Q100-003 ESD_CDM Electrostatic Discharge CDM ±500 V AEC-Q100-011 ±750 V on corner pins only Temperature Ranges and Storage Conditions TAMB Operating Ambient Temperature -40 125 °C TSTRG Storage Temperature Range -55 150 °C 020(1) RHNC Relative Humidity (non- condensing) 5 85 % MSL Moisture Sensitivity Level 3 Represents a maximum floor life time of 168 hours (1) The reflow peak soldering temperature (body temperature) is specified according to IPC/JEDEC J-STD-020 “Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices.” The lead finish for Pb-free leaded packages is “Matte Tin” (100 % Sn)
Electrical Characteristics
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 9
5 Electrical Characteristics
All limits are guaranteed. The parameters with Min and Max values are guaranteed with production tests or SQC (Statistical Quality Control) methods. All in this datasheet defined tolerances for external components need to be assured over the whole operation conditions range and also over lifetime. Overall condition: TAMB = -40 °C to 125 °C, VDD = 4.8 V to 5.2 V; components specification; unless otherwise noted
5.1 Operating Conditions
Figure 6: Symbol Parameter Conditions Min Typ Max Unit VDD VDD Static condition 4.8 5.0 5.2 V VREG Regulator Voltage 3.0 3.45 3.6 V IDD_1 Supply Current Drivers enabled 50 mA I_VL Input Low Voltage CLK, CS, SCLK, MOSI GND 0.3*VDD V I_VH Input High Voltage CLK, CS, SCLK, MOSI 0.7*VDD VDD V CLK_E System CLK Frequency 3 50 MHz SCLK SPI_CLK Frequency 8 MHz O_VL Output Low Voltage MISO GND 0.4 V O_VH Output High Voltage MISO 4.0 VDD V O_IOUT Output Current MISO 4 mA O_PD Pull-Down Value DOUT 30 200 kΩ
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 10
5.2 Analog Front End
Figure 7: Analog Front End Symbol Parameter Conditions Min Typ Max Unit SENS System sensitivity @PGA=0, CBG=0, TXV=2, FREQ=3 9.375 12.5 15.625 LSB/pF CSENSE Sensing capacity range Measuring range with 5 kOhm in parallel 20 2000 pF CLOAD capacity of cable shielding 0 2000 pF LIN Overall system linearity Sensor capacitance range 0 nF to 2 nF 1 % NOISE System noise On I or Q registers 3σ noise referenced to full scale ±0.2 % PSR System power supply rejection ±20 LSB VMM Output voltage mismatch between drivers 1 % PMM Output phase mismatch between drivers 2 Deg ROUT0 SENx output DC resistance MODE=0 10 MΩ ROUT1 SENx output DC resistance MODE=1 10 Ω ROUT2 SENx output DC resistance MODE=2 3.5 5 6.5 kΩ SCI Sensor crosstalk impedance Differential impedance between SENx pins 5 MΩ CAP Output capacitance of SEN line 8 pF DCAP Driver output capacitance drift over temp / lifetime 0.5 pF
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 11
5.3 Sensor Driver
The Sensor Driver has the ability to drive a continuously changing load of 20 pF to 2000 pF in parallel with 5 kΩ, with a 1.0 Vp-p AC term over a frequency range of 45 kHz – 125 kHz. The driver (gain 1 V/V) provides a low impedance output to drive the sensor lines (SEN0 – SEN9). Figure 8: Output Driver and Current Sensing Symbol Parameter Conditions Min Typ Max Unit SD_VDC Output DC voltage 1.18 1.23 1.28 V SD_AC2 Output voltage, TXV=2 1.020 1.070 1.120 Vpp SD_AC1 Output voltage, TXV=1 0.510 0.535 0.560 Vpp IOUT_AC Output AC peak current 8.5 mA I_SHORT Output short current to GND 50 mA SD_GAIN Gain closed loop 0.99 1 1.01 V/V ROUT Output impedance closed loop 10 Ω CLOAD Output total load capacitance 0 2000 pF
5.4 Diagnostic Thresholds
In Figure 9 the thresholds are shown, which will trigger setting the Diagnostics in the Status Register (see 7.2.2). Positive Diagnostic threshold must be higher than max level of the diagnosed signal. Negative Diagnostic threshold must be lower than min level of the diagnosed signal. Figure 9: Diagnostic Threshold Levels Symbol Parameter Min Typ Max Unit REGF_L VREG detection threshold low 3.0 3.15 3.3 V REGF_H VREG detection threshold high 3.6 3.8 4 V BPFF_L Detection threshold low 0.25 0.3 0.33 V BPFF_H Detection threshold high VREG-0.33 VREG-0.30 VREG-0.25 V
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 12 Symbol Parameter Min Typ Max Unit OCSEN Threshold sensor driver 7 8.5 10 mA OCSLD Threshold VAR_SEN 7 8.5 12 mA TXF_H1 Threshold high (TXV=1) 1.61 1.70 1.79 V TXF_H2 Threshold high (TXV=2) 1.85 1.95 2.05 V TXF_L1 Threshold low (TXV=1) 0.75 0.80 0.85 V TXF_L2 Threshold low (TXV=2) 0.46 0.50 0.54 V TXF_MP Margin between threshold high and TX positive peak 30 mVdc TXF_MN Margin between TX negative peak and threshold low 30 mVdc PGA1F_L Detection threshold low 0.2 0.25 0.28 V PGA1F_H Detection threshold high VREG-0.28 VREG-0.25 VREG-0.2 V PGA2F_L Detection threshold low 0.2 0.25 0.28 V PGA2F_H Detection threshold high VREG-0.28 VREG-0.25 VREG-0.2 V CLKD_F Frequency for flag 0.35 1 2 MHz CBF_L Detection threshold low 0.25 0.3 0.33 V CBF_H Detection threshold high VREG-0.33 VREG-0.3 VREG-0.25 V PPSF_R Threshold resistance 10 20 30 kΩ
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 13
6 Functional Description
The transceiver Analog Front-End (AFE) architecture performs the primary function of the AS8579, which is to sense the impedance of the output load. This is done using transmitter and receiver blocks. The transmitter block supplies the load a sine wave across. Then the receiver block captures the current response of the load. Here the change of the current in phase and modulus will be sensed. The current response is converted to a voltage via trance-impedance amplifier and then demodulated into in-phase (I) and quadrature (Q) components. I and Q components are then filtered and converted to 10-bit digital words via ADC. These I and Q words are accumulated awaiting 16-bit SPI transmission. Current response can be measured on any of the 10 SEN pins connected to the Sensor Driver through analog multiplexers (MUX). The external processor controls the MUX. The processor retrieves the I and Q components of each sensor from AS8579 and then determines the size of the impedance load of the external sensor(s). There are four selectable non-harmonic sensor frequencies for generating the sensor driver output
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 14
6.1 Diagnostics
6.1.1 Safety Mechanism Overview
Figure 10: Safety Mechanism Overview SM Diagnostic Name Description/Safe State Status Flag Blanking SM1 Regulator Fail Low voltage or high voltage detected on
3.3 V regulator REGF=1 Blanking
SM2 Filter Fail Voltage on internal bandpass filter is out of range BPFF=1 Blanking required(1) SM3 Overcurrent on VAR SEN Overcurrent condition on the VAR_SEN Driver OCSLD=1 Blanking required(1) SM4 Overcurrent on SEN Overcurrent condition on the sensor driver OCSEN=1 Blanking required(1) SM5 Signature Signature calculation error of OTP content. OTPF=1 Blanking not needed SM6 Out of Range (SEN Lines) Sensor driver output voltage outside operating range TX1F=1 Blanking required(1) SM7 Out of Range (VAR _SEN) Shield driver output voltage outside operating range TX2F=1 Blanking required(1) SM8 PGA FAIL 1 (I- Path) I - Channel is saturated high or low PGA1F=1 Blanking required(1) SM9 PGA FAIL 2 (Q- Path Q - Channel is saturated high or low PGA2F=1 Blanking required(1) SM10 NCLK CLK_E is missing or is invalid. NCLK=1 Blanking not needed SM11 CBF Internal current buffer output is out of range - high or low. CBF=1 Blanking required(1) SM12 PPSF Pin to Pin short diagnostic for MUX controlled outputs (SEN lines) PPSF=1 Blanking not needed (1) This signal requires to be synchronized and filtered to avoid a certain spike in MCLK domain. This signal must stay at ‘1’ for at least some MCLK cycles. The number of MCLK cycles is specified by the BLANK register (0x2B/0x3B). For this refer to 6.1.3
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 15
6.1.2 Safety Mechanism Explanation
For checking the thresholds and limits of the Safety Mechanism please refer to 5.4 SM1 Regulator Fail The safety mechanism Regulator fail is monitoring the voltage on the Regulator. The sensor provides an error flag REGF=1 in Status Register when the regulator voltage (VREG) is lower than voltage threshold REGF_L or higher than voltage threshold REGF_H. SM2 Filter Fail The safety mechanism Filter fail is monitoring the voltage of the internal Band-pass filter. The sensor provides an error flag BPFF =1 in Status Register when the input voltage of the internal Band-pass filter is lower than voltage threshold BPFF_L or higher than voltage threshold BPFF_H. SM3 Overcurrent on VAR SEN The safety mechanism Overcurrent on VAR_SEN is monitoring output current of the VAR_SEN driver. The sensor provides an error flag OCSLD=1in Status Register when the output current of driver higher than current threshold OCSLDT. SM4 Overcurrent on SEN The safety mechanism Overcurrent on SEN is monitoring output current of the sensor driver. The sensor provides an error flag OCSEN=1in Status Register when the output current of driver higher than current threshold OCSENT. SM5 Signature A signature check is performed on all the OTP content after each OTP reset pulse, this happens also at power on and after each EDIV update. In case of signature error and until the signature calculation execution a diagnostic bit OTPF = 1 is latched in the SPI Status Register. The signature bits are calculated based on the OTP content. SM6 Out of Range (SEN Lines) The safety mechanism Out of Range (SEN) is monitoring the voltage on the sensor driver output. The voltage threshold limits are depending on the configured transmitter voltage (SD_ACx). The sensor provides an error flag TX1F=1 in Status Register when the driver output voltage (SD_AC1) is lower than voltage threshold TXF_Lx or higher than voltage threshold TXF_Hx.
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 16 SM7 Out of Range (VAR_SEN & FIX_SEN) The safety mechanism Out of Range (VAR_SEN & FIX_SEN) is monitoring the voltage on the VAR_SEN and FIX_SEN driver output. The voltage threshold limits are depending on the configured transmitter voltage (SD_ACx). The sensor provides an error flag TX2F=1 in Status Register when the driver output voltage (TXDRV_AC1) is lower than voltage threshold TXF_Lx or higher than voltage threshold TXF_Hx. Figure 11: SM6 + SM7 Description SM8 PGA FAIL 1 (I-channel) The safety mechanism PGA FAIL 1 is monitoring if the I-channel is getting saturated high or low. The sensor provides an error flag PGA1F=1 in Status Register when the output voltage of I channel is lower than voltage threshold PGA1F_L or higher than voltage threshold PGA1F_H. SM9 PGA FAIL 2 (Q-channel) The safety mechanism PGA FAIL 2 is monitoring if the Q-channel is getting saturated high or low. The sensor provides an error flag PGA1F=1 in Status Register when the output voltage of Q channel is lower than voltage threshold PGA2F_L or higher than voltage threshold PGA2F_H. SM10 Missing CLK_E Diagnostic The missing CLK_E diagnostic (NCLK) monitors the system clock MCLK to ensure that it is running and therefore CLK_E is coming from the microprocessor. If CLK_E is not running or invalid, the NCLK SD_VDC TXV=2 : TXF_H2 TXV=1 : TXF_H1 TXV=2 : SD_AC2 TXV=1 : SD_AC1 TXF_MP TXF_MN TXV=2 : TXF_L2 TXV=1 : TXF_L1
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 17 bit is set in the SPI Status register. In case of this error, the chip cannot guarantee the correct synchronization between SPI clock and MCLK. SM11 CBF The safety mechanism Current Buffer Fail is monitoring the output voltage of the current-to-voltage buffer. The sensor provides an error flag CBF=1 in Status Register when the output voltage is lower than voltage threshold CBF_L or higher than voltage threshold CBF_H. SM12 PPSF The Pin-to-Pin Short diagnostic is realized with a pin-to-pin DC resistance measurement. For the pair of pins being tested, the main MUX is set to MODE=0 (open). Two diagnostic MUX can route any of the 11 tested pins (SEN lines & VAR_SEN to a comparator) programmed by PLUS/MINUS register (0x2C/0x3C), referenced by a resistive divider. In case the resistance is too low, the PPSF Flag is going high.
6.1.3 Blanking Error Flags
Each Safety Mechanism has its own Up/Down Counter (individually blanked). See 7.2.2 Status Register or 6.1.1 Safety Mechanism Overview for details on which diagnostic needs blanking. The 0x2B command is used to read the current value of the BLANK register. The counters are clocked from a signal synchronous with the transmitter sine wave. Effectively each Diagnostic is checked once per sine cycle. The diagnostic bits in the Status Register which need blanking, do not clear when Error is disappearing. They are latched until the Status Register is read through SPI. Figure 12: Example Diagnostic Maturity Using Blanking Description in chapter “Diagnostic Blanking Register (Address 0x2B/0x3B) Fault detected (analog) Clock - ZC 0000 1111 1110 1101 1100 1011 1010 1001 1000 0111 0110 0101 0100 0011 0010 0001 Fault Status BitBlanking Counter [3:0] Value=$8 Fault matured
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 18
6.2 SPI Interface
The sensor contains a single serial peripheral interface (SPI), consisting of Serial Clock (SCLK), Data Out (MISO), Data In (MOSI), and Chip Select (CS) pins. The AS8579 is configured as a SPI slave. The SPI interface is used to edit Register content, access Control and readout Sensor Values The CS input selects this device for serial transfers. CS is active high. Register data is shifted in the MOSI pin and shifted out the MISO pin on each subsequent SCLK. The CS input has a pull-down internal to the IC, which pulls this pin to the negated state should an open circuit condition occur. The SCLK input is the clock signal input for synchronization of serial data transfer. When CS is asserted, both the SPI master and the slave latch input data on the rising edge of SCLK. The SPI master typically shifts data out on the falling edge of SCLK, as does this device. SCLK input has a pull-down internal to the AS8579 which pulls this pin to the negated state should an open circuit condition occur. SCLK can idle in either state (high or low). The MISO output pin is in a tri-state condition when CS is low. Data is transmitted on MISO MSB first. MISO has a weak pull-down to set the bus to a defined state when the output is in tri-state mode. MOSI takes data from the master microprocessor while CS is asserted. Data is received MSB first. MOSI has a pull-down internal to the AS8579 which pulls this pin to the negated state should an open circuit condition occur. Figure 13: SPI TIMING Symbol Parameter Min Typ Max Unit tSCK SCLK Period 125 ns tLEAD Enable Lead Time 16.25 ns tLAG Enable Lag Time 12.5 ns tSCKHS SCLK High Time 25 ns tSCKLS SCLK Low Time 25 ns tSUS MOSI Input Setup Time 5 ns tHS MOSI Input Hold Time 5 ns tA MISO Access Time 50 ns tDIS MISO Disable Time 25 ns tVS MISO Output Valid Time 20 ns tHO MISO Output Hold Time 0 ns
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 19 Symbol Parameter Min Typ Max Unit tRO Rise Time 7.2 ns tFO Fall Time 7.5 ns tCS_N CS_N Negated Time 50 ns fOP Transfer Frequency DC 8 MHz Figure 14: Timing Diagram The serial communications shall be accomplished with the CS, SCLK, MOSI, and MISO pins. The host CPU selects the AS8579 with the CS signal and shifts data into the AS8579 MOSI input using the SCLK for synchronizing the bit shifts. Upon receiving SCLKs from the host CPU (when selected), the AS8579 shifts data out the MISO pin. Serial data from MOSI is latched into the shift register on the rising edge of SCLK. Data is shifted out to MISO on the falling edge of SCLK. There are 3 types of commands for the SPI:
- Read
- Write
- “Quick Read” All command and data bytes are 8 bits wide. Data bytes always sent and received MSB first. CS (Input) SCLK (Input) MOSI (Input) MISO (Output) tSCKtLEAD tSUS tA tDIS tLAG tCS_N tSCKHS tSCKLS MSB MSB Data Data LSB LSB tHS tVS tRO tFO tHO
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 21 The 0x90 command allows for I and Q data to be read from the same sensor signal sample by doing a quick read on both I and Q data registers. This command links the I and Q registers together into a 32-bit word. This data is read back using a 40-bit word in this order: command byte, I data word, Q data word. I/Q data matching is guaranteed using the Quick Read command (i.e. – I and Q data will be from a matched sample). The I and Q data registers are reset to 0x00 after reading. Figure 17: SPI Example of Read Sensor ID, Write EDIV and Read EDIV Register ADDR = 0x01 CS SCLK MOSI MISO Read Sensor ID (Sensor ID = 0xA431) Write EDIV (EDIV = 0x00 0x01) Read EDIV (EDIV = 0x00 0x01) DATA1=0x00 DATA2=0x00 cmd* = 0x01 Data1 = 0xA4 Data2 = 0x31 * Sensor repeat command ADDR = 0x30 DATA1=0x00 DATA2=0x01 cmd* = 0x01 Data1 = 0x00 Data2 = 0x00 ADDR = 0x20 DATA1=0x00 DATA2=0x00 cmd* = 0x01 Data1 = 0x00 Data2 = 0x01 CS SCLK MOSI MISO CS SCLK MOSI MISO
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 22 ADC Functional Description For digitizing the I and Q values, a 10-bit ADC is used. Conversions are run using the internal system clock. The ADC can do different conversion modes. This can be set in the ADCTL register (0x2A/0x3A). (see 7.2.16) Single Conversion “Single Conversion” causes the ADC to wait for the “system settling time" before starting sampling and then to accumulate the number of samples, specified in the register ADCTL [5:4]. I and Q samples arrive interleaved. The DSP control logic will provide the analog part the signal IQMUX to switch the ADC analog input between I channel and Q channel. Once completed, I and Q results are moved to the SPI output registers and the “ADC_COMPLETE” bit in register 0x05 is set. Before another “Single Conversion” can be started, the ADC must be reset by either performing a Quick Read (0x90), or by issuing the “ADC Reset” command. Figure 18: Measuring Cycle Continuous Conversion “Continuous Conversion” mode causes the ADC to take successive samples accumulations of I and Q, again the number of samples taken is specified by ADCTL [5:4] register (0x2A/0x3A). The ADC is time multiplexed between the I and Q channels (I and Q samples are interleaved). Each data point stored to the SPI output register is the accumulation of a programmed number of 10-bit ADC values, for each I and Q. Data is stored to the SPI as a complete I and Q set (data synchronicity is guaranteed by the Control Logic). Set-up ADCGO Settling phase I and Q Sampling phase I Q I Q I Q I Q 400ms 352ms ADC_COMPLETE 50ms ADC sampling period: Tsample=ADCLK*11 Sampling phase: TsampPH=Tsample*8
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 23 Figure 19: Measuring Cycle Before changing a parameter of the ADCTL [7:0] (0x2A/0x3A) the ADC and accumulators have to be reset, this operation is done by writing ADCTL [1:0] = 0. This resets the DSP and brings ADC to reset condition as well. In a next SPI access the command start of conversion are sent (single / continuous conversion) Set-up ADCGO Settling phase I and Q Sampling phase I Q I Q I Q I Q 352ms50ms ADC sampling period: Tsample=ADCLK*11 Sampling phase: TsampPH=Tsample*8 Sampling phase Sampling phase I Q I Q I Q I Q ADC sampling period: Tsample=ADCLK*11 Sampling phase: TsampPH=Tsample*8 Sampling phase.. I Q I 352ms
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 24
7 Register Description
7.1 Register Overview
7.1.1 Position of the Read/Write Bit
The position of the Read/Write Bit is at Bit [4] of the command byte, which implies that the register address for reading a register is different as write the same register. Figure 20: Position of Read/Write Bit Figure 21: Register Overview Read ADDR Write ADDR Name Default Description 0x01 Sensor ID 0xA431 ID of the Sensor 0x02 Status Reg 0x0000 Error Register 0x03 I_DATA 0x0000 I Data Information 0x04 Q_DATA 0x0000 Q Data Information 0x05 ADC_Status 0x0000 Bit is set when the ADC has completed 0x20 0x30 EDIV 0x0000 System CLK Divider Selection (CLK_E) 0x21 0x31 FREQ 0x0000 Frequency Selection 0x20 = 0 0 1 0 0 0 0 0 Read 0x30 = 0 0 1 1 0 0 0 0 Write 0x21 = 0 0 1 0 0 0 0 1 Read 0x31 = 0 0 1 1 0 0 0 1 Write 0x22 = 0 0 1 0 0 0 1 0 Read 0x32 = 0 0 1 1 0 0 1 0 Write EDIV Register FREQ Register TXV Register R/W
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 25 Read ADDR Write ADDR Name Default Description 0x22 0x32 TXV 0x0000 Sensor Driver Voltage Selection 0x23 0x33 SEN/MODE 0x0000 MUX control for the connected SENx Pins 0x24 0x34 SDG 0x0000 VAR_SEN Gain Selection 0x25 0x35 CBG 0x0000 Current Buffer Gain Selection 0x26 0x36 DCLK 0x0000 Demodulation Clock Selection 0x27 0x37 PGA 0x0000 Command sets the PGA voltage Gain. Adjusts the input voltage to the ADC to optimize its conversion resolution. 0x28 0x38 OFFSET_I PGA 0x0000 Command is used to program the offset DAC to compensate parasitic offsets 0x29 0x39 OFFSET_Q PGA 0x0000 Command is used to program the offset DAC to compensate parasitic offsets 0x2A 0x3A ADCTL 0x0000 Controls the ADC converter cycles 0x2B 0x3B BLANK 0x003F This Register is used to program the 6-Bit register up/down counter used for blanking faults 0x2C 0x3C PLUS/MINUS 0x00FF Control the pin-to-pin short diagnostic MUX
7.2 Detailed Register Description
7.2.1 Sensor ID Register (Address 0x01)
The 0x01 command is used to read the ID Register. Reading this register will always return 0xA431. This is used by the microprocessor to validate the SPI communication to the sensor. Figure 22: SENSOR ID Register AS8579 ID [15:0] Binary Read/Write Default Value 1010 0100 0011 0001 R 0xA431
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 26
7.2.2 Status Register (Address 0x02)
The 0x02 command is used to read the Status Register plus diagnostics. Figure 23: Status Register Name Bit Position Read/Write Description R_EDIV 15:13 R Bit [0:2] from EDIV Register (0x20/0x30) OTPF 12 R Occurs when signature of the OTP is wrong PPSF 11 R Pin-to-Pin short Error. Pins under test are shorted together. Blanking not needed. BPFF 10 R Occurs when voltage of internal filter is exceeding the operating range. REGF 9 R Error Flag (=1) occurs Regulator voltage is exceeding the operating range. Blanking not needed. OCSLD 8 R Error Flag (=1) occurs when current exceeds the maximum limit. OCSEN 7 R Error Flag (=1) occurs when current exceeds the maximum limit. TEST 6 R For internal use TX1F 5 R Error Flag (=1) occurs output voltage of sensor driver is exceeding the operating range. TX2F 4 R Error Flag (=1) occurs output voltage of VAR_SEN driver is exceeding the operating range. PGA1F 3 R PGA1F=1 when I channel is saturated high or low. PGA2F 2 R PGA2F=1 when Q channel is saturated high or low. NCLK 1 R NCLK=1 when the clock is missing or invalid on CLK_E CBF 0 R CBF=1 occurs when output voltage of current buffer is exceeding the operating range.
7.2.3 I-Channel Data (Address 0x03)
According to the register settings the Accumulated Data for the I-Channel. Dependent on the accumulation setting in the ADCTL register (0x2A/0x3A), the value can be from 12 up to 14 bits. The content of the register can be read out with command 0x90.
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 27 Figure 24: I-Channel Data Name Bit String (13:0) Read/Write Description ACCU I XX00 0000 0000 0000 R Data Register
7.2.4 Q-Channel Data (Address 0x04)
According to the register settings the Accumulated Data for the Q-Channel. Dependent on the accumulation setting in the ADCTL register (0x2A/0x3A), the value can be from 12 up to 14 bits. The content of the register can be read out with command 0x90. Figure 25: Q-Channel Data Name Bit String (13:0) Read/Write Description ACCU Q XX00 0000 0000 0000 R Data Register
7.2.5 ADC Status Register (Address 0x05)
The 0x05 command is used to read the “ADC Complete” status bit (Bit [0] from Register 0x05). This bit is set when the ADC has completed the accumulation of the programmed samples of both the I and Q data signals and placed the data in the SPI output registers. The bit is cleared upon reading the combined data registers (0x90 command) or when a new ADC cycle is initiated. Figure 26: ADC Status Name Bit Position Read/Write Measurement Data ADC complete 0 R Bit is set (1) when ADC has completed accumulation.
7.2.6 CLK_E Timing Selection Register (Address 0x20/0x30)
The 0x30 command controls the division factor (EDIV [3:0]) applied to CLK_E pin to generate the internal system clock. The division factor is programmable from 1 to 12. Default value at power-up is 12. The 0x20 command is used to read the current value of EDIV. The applied system clock must be at 4 MHz after the CLK_E Frequency dividing factor. (e.g.48 MHz / 12 = 4 MHz)
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 28 Figure 27: EDIV Register EDIV [3:0] Binary Read/Write CLK_E Frequency Dividing Factor
0000 R/W 12
0001 R/W 11
0010 R/W 10
0011 R/W 9
0100 R/W 8
0101 R/W 7
0110 R/W 6
0111 R/W 5
1000 R/W 4
1001 R/W 3
1010 R/W 2
1011 R/W 1
1100 R/W 1
1101 R/W 1
1110 R/W 1
1111 R/W 1
The clock obtained by the frequency division of the CLK is called MCLK and is used to clock all the digital part except the SPI interface. Each time there is an EDIV change, an automatic OTP reset is generated to clean up the memory from possible timing error if the previous selected MCLK was higher than 4 MHz. The reload of the OTP memory takes less than 8190 MCLK clock cycles, during the reload phase it is possible to have SPI communication, but not possible to start sensing.
7.2.7 Frequency Selection Register (Address 0x21/0x31)
The 0x31 command is used to select the sine wave generator frequency for the sensor driver output. At power-up, FREQ default is set to 0x00. The 0x21 command is used to read the current value of FREQ.
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 29 Figure 28: Frequency Selection FREQ [1:0] Binary Read/Write Frequency [kHz] 00 R/W 45.45 01 R/W 71.4
10 R/W 100
11 R/W 125
7.2.8 Sensor Driver Voltage Selection Register (Address 0x22/0x32)
The 0x32 command sets the transmitter output AC voltage (TXV). At power-up, TXV defaults to 0x00. The 0x22 command is used to read the current value of TXV. TXF1 and TXF2 diagnostic bits are not valid when TXV=0x00 or TXV=0x03. Figure 29: Sensor Driver Voltage Selection TXV [1:0] Binary Read/Write Output Voltage Peak-Peak [V]
00 R/W 0
01 R/W 0.5 10 R/W 1.0
11 R/W 0
7.2.9 MUX Control Register (Address 0x23/0x33)
The 0x33 command controls the ten 3-channel MUXES connected to the SENx pins. It also controls the 2-channel MUX connected to the VAR_SEN pin. The 0x23 command reads the current data in the channel select control register.
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 30 Figure 30: MUX Control Register Figure 31: MUX Control Register Description Settings Name Bit Number Read/Write Measurement Data Mode 0:1 R/W Mode Selection SEN 2:5 R/W Channel Selection X 6:7 R Not Used Figure 32: MUX Register Channel Selection (SEN) SENx MUX Selected
0000 SEN0
0001 SEN1
0010 SEN2
0011 SEN3
0100 SEN4
0101 SEN5
0110 SEN6
0111 SEN7
1000 SEN8
1001 SEN9
1010 None
1011 VAR_SEN
1100 None
X X SEN SEN SEN SEN MODE MODE MSB LSB
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 31 Figure 33: MUX Register Mode Selection (MODE) MODE SENx Connected To
00 Open
01 Sensor Driver
10 Common Mode through 5 kΩ resistor
11 No Operation
7.2.10 VAR_SEN Gain Selection (Address 0x24/0x34)
The VAR_SEN Driver Attenuator is used to scale down the VAR_SEN amplitude. The VAR_SEN amplitude is always related to the Sensor driver amplitude Figure 34: VAR_SEN Gain Selection Current Buffer Gain Program Parameter Min Typ Max Unit SDG=0 00 . 1 . V/V SDG=1 01 0.931 0.95 0.969 V/V SDG=2 10 0.882 0.9 0.918 V/V SDG=3 11 0.833 0.85 0.867 V/V
7.2.11 Current Buffer Gain Selection (Address 0x25/0x35)
For the conversion from current to voltage, a trans-impedance amplifier is implemented. The upper range will be extended by programmable scaling factors. Figure 35: Current Buffer Gain Settings Current Buffer Gain Program Parameter Min Typ Max Unit CBG=0 00 16.2 18 19.8 kOhm CBG=1 01 8.1 9 9.9 kOhm CBG=2 10 4.05 4.5 4.95 kOhm
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 32 Current Buffer Gain Program Parameter Min Typ Max Unit CBG=3 11 2.02 2.25 2.47 kOhm
7.2.12 Demodulation Clock Selection (Address 0x26/0x36)
In this register, you can set the demodulation clock frequency for I and Q-path Figure 36: DCLK Settings DCLK Value Program Parameter Upper Path Lower Path Signal Clock Clock Phase Signal Clock Clock Phase DCLK=0 00 ICLK In phase QCLK In phase DCLK=1 01 QCLK In phase ICLK In phase DCLK=2 10 ICLK 180° out of phase QCLK 180° out of phase DCLK=3 11 QCLK 180° out of phase ICLK 180° out of phase
7.2.13 PGA Voltage Gain Control (Address 0x27/0x37)
The 0x37 command sets the PGA voltage gain. This 3-bit number (PGA [2:0]) adjusts the input voltage level to the ADC to optimize its conversion resolution. The 0x27 command reads the PGA value. At power-up, PGA defaults to 0x00.The PGA is defined as an inverted amplifier. Figure 37: PGA Settings PGA Value PGA [2:0] Binary Read/Write PGA Gain PGA_0 000 R/W 36 PGA_1 001 R/W 24 PGA_2 010 R/W 16 PGA_3 011 R/W 10.67 PGA_4 100 R/W 7.11 PGA_5 101 R/W 4.74 PGA_6 110 R/W 3.16
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 33 PGA Value PGA [2:0] Binary Read/Write PGA Gain PGA_7 111 R/W 2.11
7.2.14 PGA Offset Control I-Channel (Address 0x28/0x38)
The 0x38 command is used to program the offset DACs for the I-channel. This offset compensates for the parasitic offsets in the sensor system and allows to shift DC operating point in order to maximize the ADC range. The 0x28 command reads the current values of OFFSET1. DAC outputs can be set to 256 settings (VREG/256) between GND and VREG. (8-bit) The Offset DAC is used to change the DC operating point of the ADC input. Increasing the Offset DAC value one count will decrease the ADC input by 80 counts before the accumulation.
7.2.15 PGA Offset Control Q-Channel (Address 0x29/0x39)
The 0x39 command is used to program the offset DAC for the Q-channel. This offset compensates for the parasitic offsets in the sensor system and allows to shift DC operating point in order to maximize the ADC range. The 0x29 command reads the current values of OFFSET2. DAC outputs can be set to 256 settings (VREG/256) between GND and VREG. (8-bit) The Offset DAC is used to change the DC operating point of the ADC input. Increasing the Offset DAC value one count will decrease the ADC input by 80 counts before the accumulation.
7.2.16 ADC Control Register (Address 0x2A/0x3A)
The 0x3A command controls the ADC converter cycles. The 0x2A command reads out the ADCTL register. Figure 38: ADCTL Register Overview TS TS ACCU ACCU CS CS ADC STATE ADC STATE MSB LSB
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 35 Figure 42: ADC Frequency Setting ADCTL [3:2] Binary System Settling Time in Periods ADCLK Frequency [kHz] 00 16 * MCLK_p 250 01 8 * MCLK_p 500 10 4 * MCLK_p 1000 11 16 * MCLK_p 250 ADCTL [1:0] selects the ADC state Figure 43: ADC State ADCTL [1:0] Binary ADC State
00 RESET of DSP and ADC stop
01 Start single conversion
10 Start continuous conversions
11 Stop current conversions
Figure 44: ADCTL vs System Timing ADCTL Selected Settings System Timing Settling [7:6] Samples [5:4] Freq [3:2] Settling Time (µs) Number of I/Q Samples ADC I/Q Sample Rate (kHz) Settling Time (µs) ADC Sampling Time (µs) Total Time (µs) 00 00 00 400 4 11.36 400 352 752 00 00 01 400 4 22.73 400 176 576 00 00 10 400 4 45.45 400 88 488 00 01 00 400 8 11.36 400 704 1104 00 01 01 400 8 22.73 400 352 752 00 01 10 400 8 45.45 400 176 576 00 10 00 400 16 11.36 400 1408 1808
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 36 ADCTL Selected Settings System Timing Settling [7:6] Samples [5:4] Freq [3:2] Settling Time (µs) Number of I/Q Samples ADC I/Q Sample Rate (kHz) Settling Time (µs) ADC Sampling Time (µs) Total Time (µs) 00 10 01 400 16 22.73 400 704 1104 00 10 10 400 16 45.45 400 352 752 01 00 00 576 4 11.36 576 352 928 01 00 01 576 4 22.73 576 176 752 01 00 10 576 4 45.45 576 88 664 01 01 00 576 8 11.36 576 704 1280 01 01 01 576 8 22.73 576 352 928 01 01 10 576 8 45.45 576 176 752 01 10 00 576 16 11.36 576 1408 1984 01 10 01 576 16 22.73 576 704 1280 01 10 10 576 16 45.45 576 352 928 10 00 00 664 4 11.36 664 352 1016 10 00 01 664 4 22.73 664 176 840 10 00 10 664 4 45.45 664 88 752 10 01 00 664 8 11.36 664 704 1368 10 01 01 664 8 22.73 664 352 1016 10 01 10 664 8 45.45 664 176 840 10 10 00 664 16 11.36 664 1408 2072 10 10 01 664 16 22.73 664 704 1368 10 10 10 664 16 45.45 664 352 1016
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 37
7.2.17 Diagnostic Blanking Register (Address 0x2B/0x3B)
The 0x3B command is used to program the 6-bit register up/down counter used for blanking diagnostics. A diagnostic is not reported in the Status Register until the Up/Down Counter has reached the programmed terminal value (BLANK).
7.2.18 Diagnostic MUX Control (Address 0x2C/0x3C)
The 0x3C command is used to control the pin-to-pin short diagnostic MUX. This register is made up of two 4-bit registers PLUS[3:0] and MINUS[3:0]. PLUS controls the pin connected to the positive side of the comparator, MINUS to the negative side. The default value at POR is 0x00FF (all pin-to-pin short MUXes are OFF). Figure 45: Diagnostic Mux Control Register Figure 46: MUX Diagnostics Control PLUS/MINUS [3:0] Binary Read/Write Pin Connected to Comparator
0000 R/W SEN0
0001 R/W SEN1
0010 R/W SEN2
0011 R/W SEN3
0100 R/W SEN4
0101 R/W SEN5
0110 R/W SEN6
0111 R/W SEN7
1000 R/W SEN8
1001 R/W SEN9
1010 R/W NONE
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 38 PLUS/MINUS [3:0] Binary Read/Write Pin Connected to Comparator
1011 R/W VAR_SEN
1100 R/W NONE
1101 R/W NONE
1110 R/W NONE
1111 R/W NONE (default)
Figure 47: Diagnostic MUX Control Comparator MUX MUX SEN[0:9], VAR_SEN SEN[0:9], VAR_SEN PLUS MINUS PPSF
Application Information
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 39
8 Application Information
8.1 Typical Application Circuit
Figure 48: Typical Application Circuit The pin FIX_SEN is connected to the PCB that carries the AS8579. The VAR_SEN pin is connected to the shielding of the Sensor cable. 680nF GND 100nF AS8579 µC 5V5V 680nF RLoad CLoad
Package Drawings & Markings Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 40
9 Package Drawings & Markings
Figure 49: Ref. Min Nom Max A 1.73 1.86 1.99 A1 0.05 0.13 0.21 A2 1.68 1.73 1.78 b 0.22 0.30 0.38 c 0.09 0.17 0.25 D 7.90 8.20 8.50 E 7.40 7.80 8.20 E1 5.00 5.3 5.6 e 0.65 BSC L 0.55 0.75 0.95 L1 1.25REF L2 0.25REF R 0.09 - - Ɵ 0° 4° 8° N 24 (1) All dimensions are in millimeters. Angles in degrees. (2) Dimensioning and tolerancing conform to ASME Y14.5M-1994. (3) N is the total number of terminals. (4) This package contains no lead (Pb). (5) This drawing is subject to change without notice. RoHS Green
Package Drawings & Markings Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 41 Figure 50: YY Manufacturing Year WW Manufacturing Week M Assembly Plant Identifier ZZ Assembly Traceability Code @ Sublot Identifier
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 42 Document Status Product Status Definition Product Preview Pre-Development Information in this datasheet is based on product ideas in the planning phase of development. All specifications are design goals without any warranty and are subject to change without notice Preliminary Datasheet Pre-Production Information in this datasheet is based on products in the design, validation or qualification phase of development. The performance and parameters shown in this document are preliminary without any warranty and are subject to change without notice Datasheet Production Information in this datasheet is based on products in ramp-up to full production or full production which conform to specifications in accordance with the terms of ams-OSRAM AG standard warranty as given in the General Terms of Trade Datasheet (discontinued) Discontinued Information in this datasheet is based on products which conform to specifications in accordance with the terms of ams-OSRAM AG standard warranty as given in the General Terms of Trade, but these products have been superseded and should not be used for new designs Changes from previous version to current revision v4-01 Page Changes from v3-00 to v4-00 Updated Figure 2 4 Changes from v4-00 to v4-01 Updated comments for ESD_CDM, Figure 5 8
Datasheet • PUBLIC DS000707 • v4-01 • 2022-Jun-08 43 │ 43
11 Legal Information
Copyrights & Disclaimer Copyright ams-OSRAM AG, Tobelbader Strasse 30, 8141 Premstaetten, Austria-Europe. Trademarks Registered. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. Devices sold by ams-OSRAM AG are covered by the warranty and patent indemnification provisions appearing in its General Terms of Trade. ams-OSRAM AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein. ams-OSRAM AG reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with ams-OSRAM AG for current information. This product is intended for use in commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are specifically not recommended without additional processing by ams-OSRAM AG for each application. This product is provided by ams-OSRAM AG “AS IS” and any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are disclaimed. ams-OSRAM AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligat ion or liability to recipient or any third party shall arise or flow out of ams-OSRAM AG rendering of technical or other services. RoHS Compliant & ams Green Statement RoHS Compliant: The term RoHS compliant means that ams-OSRAM AG products fully comply with current RoHS directives. Our semiconductor products do not contain any chemicals for all 6 substance categories plus additional 4 substance categories (per amendment EU 2015/863), including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, RoHS compliant products are suitable for use in specified lead-free processes. ams Green (RoHS compliant and no Sb/Br/Cl): ams Green defines that in addition to RoHS compliance, our products are free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) and do not contain Chlorine (Cl not exceed 0.1% by weight in homogeneous material). Important Information: The information provided in this statement represents ams-OSRAM AG knowledge and belief as of the date that it is provided. ams-OSRAM AG bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. ams-OSRAM AG has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. ams-OSRAM AG and ams-OSRAM AG suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. Headquarters ams-OSRAM AG Tobelbader Strasse 30
8141 Premstaetten
Austria, Europe Tel: +43 (0) 3136 500 0 Please visit our website at www.ams.com Buy our products or get free samples online at www.ams.com/Products Technical Support is available at www.ams.com/Technical-Support Provide feedback about this document at www.ams.com/Document-Feedback For sales offices, distributors and representatives go to www.ams.com/Contact For further information and requests, e-mail us at ams_sales@ams.com