SoC for Ultrasonic Flow Meters v1-00 • 2020-May-06
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 2 Content Guide
7 Typical Operating Characteristics
12 Memory and Register Description
15.8 Measurement Start in Time Conversion
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 3
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 4
1 General Description
AS6031 is an ultrasonic flow converter for the next generations of ultrasonic water and heat meters. It is highly integrated and is based on the TDC-GP30 platform. It uses the same high-performant front- end for driving the transducers and processing the receive signal to extract the time of flight information. An additional programmable amplifier allows handling weaker receive amplitudes. Additional features for phase-modulated hit identification give even more robustness to the first hit level detection. The integrated low-power CPU can use 4k of NVRAM and 4k of ROM code to do the flow calculation on chip. AS6031 simplifies the design of ultrasonic water and heat meters, combining the precise measurement and the complex flow calculation. It provides outstanding low-flow detection capability due to excellent zero-flow drift. Users can apply any of-the-shelf µP for handling all other tasks like display management or wireless communication and a complete meter device. The integrated standard pulse interface enables one-to-one replacement of mechanical meters by AS6031 based single-chip heat and water meters – customer µP and software remains unchanged. The ultra-low-current capabilities allow the use of standard AA batteries at 6-8 Hz measuring frequency even in the water meter version. The chip comes in a compact QFN48 package and allows compact designs thanks to a small number of external components.
1.1 Key Benefits & Features
The benefits and features of AS6031, SoC for Ultrasonic Flow Meters are listed below: Figure 1: Added Value of Using AS6031 Benefits Features Single-chip solution provides ready flow information System design compatible with mechanical meters High flexibility in choice for external µP handling communication and further data management High performance + ultra-low power 32-Bit CPU 120 * 32-bit NVRAM (non-volatile RAM) for user firmware parameter & data 3968 * 8-bit NVRAM (non-volatile RAM) for user firmware program code 4k * 8-bit ROM for system task code and special flow library code Precision down to low flow rates Leakage detection Advanced high-precision analog front-end for transducer frequencies of 50 kHz to 4 MHz at 2.5 V to 3.6 V drive voltage Integrated PGA, gain 2 to 17 V/V @ 1 MHz
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 5 Benefits Features Handles weak signals for small transducers and multiple reflections First hit level and phase detection Amplitude measurement Up to 31 zero crossing measurements Precision time-to-digital converter and low-noise front-end with < 50 ps single shot with good 1MHz transducers on a DN20 Ultra-low power consumption Compact design Low BOM SPI serial interface General Purpose I/O Unit incl. pulse interface and 2-wire master interface (I2C like) Supply voltage 2.5(1) to 3.6 V 3.0 to 3.6 V NVRAM store only Operating temperature -40(1) to 85°C QFN48 package (7 x 7mm²) (1) With workaround or limitation in combinations
1.2 Applications
- Water meters for utilities
- Industrial water meters
- Heat meters
- Gas meters
- Volume counters
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 6
1.3 Block Diagram
The functional blocks of this device are shown below: Figure 2 : Functional Blocks of AS6031 LSO Ultrasonic Frontend (UFE) Temperature Interface Ultrasonic Interface Amplitude Zero Crossing PGA Digital Core TPI_M2_B TPI_M2_A TPI_M1_B TPI_M1_A TPI_REF TPI_CLOAD TPI_GND1 TPI_GND2 US_UP_P US_DOWN_M US_DOWN_M US_UP_M US_DOWN US_UP US_VREF RECEIVE_SIG INVERT_IN PGA_OUT COMP_IN Supervisor / Task Sequencer CPU Front-end Processing Memory HSO Digital IO Power Supply VDD18_IN XIN_4MHZ XOUT_4MHZ GND XIN_32KHZ XOUT_32KHZ TEST_MODE_PS TEST_RST SSN MOSI SCK MISO INTN GPIO0 GPIO1 GPIO2 GPIO3 GPIO4 VDD18_OUT LP_MODE GPIO5 VCC
Ordering Information
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 7
2 Ordering Information
Ordering Code Package Marking Delivery Form Delivery Quantity AS6031-BQFM QFN48 AS6031-BQF Tape & Reel 500 pcs/reel
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 8
3 Pin Assignment
3.1 Pin Diagram
Figure 3: AS6031 Pin Diagram VCC LP_MODE US_UP GND US_DOWN US_UP_M US_UP_P US_DOWN_P US_DOWM_M INVERT_IN TEST_RST GPIO2 GPIO1 GPIO0 VCC COMP_IN RECEIVE_SIG US_VREF GPIO5 PGA_OUT XIN_4MHz VDD18_IN SSN MOSI GPIO4 TEST_MODE_PS SCK MISO INTN GPIO3 TPI_REF TPI_M1_B TPI_M1_A TPI_CLOAD TPI_M2_B TPI_M2_A TPI_GND1 AS6031 NC NC TPI_GND2 VDD18_IN VDD18_OUT XIN_32KHZ XOUT_32KHZ VCC XOUT_4MHZ NC NC
3.2 Pin Description
Figure 4: Pin Description of AS6031 Pin Number Pin Name Pin Type(1) Description
1 VCC S IO & Analog Supply
2 LP_MODE DI Low Power Mode, fix internal pull-up
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 9 Pin Number Pin Name Pin Type(1) Description
3 US_UP AIO Transducer Port LV interface
4 GND S Ground
5 US_DOWN AIO Transducer Port LV interface
6 US_UP_M AIO Not used
7 US_UP_P AIO Not used
8 US_DOWN_P AIO Not used
9 US_DOWN_M AIO Not used
10 INVERT_IN AIO Inverting Input PGA
13 PGA_OUT AIO Output PGA
14 GPIO5 DIO General Purpose 5, optional pull-up/pull-down
15 US_VREF AIO Ultrasonic Reference Voltage
16 RECEIVE_SIG AIO Receive Signal
17 COMP_IN AIO Comparator Input
18 VCC IO & Analog Supply
19 GPIO0 DIO General Purpose 0, optional pull-up/pull-down
20 GPIO1 DIO General Purpose 1, optional pull-up/pull-down
21 GPIO2 DIO General Purpose 2, optional pull-up/pull-down
22 TEST_RST DI Test Reset, must be connected to GND
23 XIN_32KHZ AIO Low Speed Oscillator
24 XOUT_32KHZ AIO Low Speed Oscillator
25 GPIO3 DIO General purpose 3, optional pull-up/pull-down
26 INTN DO Interrupt, low active
27 MISO DO SPI: Slave Out with tristate
28 SCK DI(2) SPI: Serial Clock
29 TEST_MODE_PS DI Test Mode, fix internal pull-down
30 GPIO4 DIO General Purpose 4, optional pull-up/pull-down
31 MOSI DI(2) SPI: Slave In
32 SSN DI(2) SPI: Slave Select, low active
33 VDD18_IN S VDD18 Digital Core Supply
34 XIN_4MHZ AIO High Speed Oscillator
35 XOUT_4MHZ AIO High Speed Oscillator
36 VCC S IO & Analog Supply
37 TPI_REF AIO Temperature Interface: Ref. Port
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 10 Pin Number Pin Name Pin Type(1) Description
38 TPI_M1_B AIO Temperature Interface: Port M1 B
39 TPI_M1_A AIO Temperature Interface: Port M1 A
40 TPI_CLOAD AIO Temperature Interface: Port CLOAD
41 TPI_M2_B AIO Temperature Interface: Port M2 B
42 TPI_M2_A AIO Temperature Interface: Port M2 A
43 TPI_GND1 Temperature Interface: Ground1
44 TPI_GND2 Temperature Interface: Ground2
47 VDD18_IN S VDD18 Digital Core Supply
48 VDD18_OUT S VDD18 Voltage Regulator Output
(1) Explanation of abbreviations: DI Digital Input AIO Analog Input/Output DO Digital Output S Supply DIO Digital Input/Output (2) For standalone operation without external controller, the unconnected inputs should be configured with internal pull up by SPI_INPORT_CFG in CR_IFC_CTRL.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 11
4 Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings“ may cause permanent damage to the device. These are stress ratings only. Functional operation of the device at these or any other conditions beyond those indicated under “Operating Conditions” is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Figure 5 Symbol Parameter Min Max Unit Comments Electrical Parameters VCC Supply Voltage to Ground -0.3 4.0 V Voth All other Pins Voltage to Ground -0.3 VCC + 0.6 V Electrostatic Discharge ESDHBM Electrostatic Discharge HBM ± 1k V JS-001-2017 ESDCDM Electrostatic Discharge CDM ± 0.5k V JS-002-2018 Temperature Ranges and Storage Conditions TSTRG Storage Temperature Range - 55 150 °C RHNC Relative Humidity (non- condensing) 5 85 % MSL Moisture Sensitivity Level 1 Maximum floor lifetime of 168h tSTRG_DOF Storage Time for DOF/Die or Wafers on Foil 3 months Refers to indicated date of packing TSTRG_DOF Storage Temperature for DOF/Die or Wafers on Foil 17 28 °C RHOPEN_DOF Relative Humidity for DOF/Die or Wafers on Foil in Open Package 15 % Opened package RHUNOPEN_DOF Relative Humidity for DOF/Die or Wafers on Foil in Sealed Package 40 60 % Sealed bag tSTRG_WP Storage Time for WP/Wafers or Die in Waffle Pack 6 months 17 °C – 28 °C 40 % – 60 % relative humidity storage in original Ultrapack boxes tSTRG_WP Storage Time for WP/Wafers or Die in Waffle Pack 2 years 19 °C – 25 °C <15 % relative humidity storage in closed cabinet with dry air tSTRG_WP Storage Time for WP/Wafers or Die in Waffle Pack 5 years 19 °C – 25 °C <5 % relative humidity storage in closed cabinet with dry air
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 12 Symbol Parameter Min Max Unit Comments tSTRG_WP Storage Time for WP/Wafers or Die in Waffle Pack 10 years 19 °C – 25 °C <5 % relative humidity storage in closed cabinet and closed Ultrapak box with safeguarded Nitrogen atmosphere Bump Temperature (soldering) TPEAK Peak Temperature 235 245 °C Solder Profile tWELL Well Time above 217 °C 30 45 s (1) The reflow peak soldering temperature (body temperature) is specified according to IPC/JEDEC J-STD-020 “Moisture/Reflow Sensitivity Classification for Non-hermetic Solid-State Surface Mount Devices.” The lead finish for Pb-free leaded packages is “Matte Tin” (100 % Sn)
Electrical Characteristics
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 13
5 Electrical Characteristics
Electrical characteristics and operating conditions indicate conditions for which the device is functional, but do not guarantee specific performance limits. Test conditions for guaranteed specification are expressly denoted. All data given at VCC = 3.0 V ± 0.3 V, ambient temperature -10 °C to 85 °C unless otherwise specified. Notes (a) to (e) that describe the test levels are valid for the whole sections 5 and 6. Figure 6: Recommended operating conditions of AS6031 Symbol Parameter Conditions Min Typ Max Unit Power Supply VCC Supply Voltage to Ground(a) All operations besides NVRAM store 2.5 3.0 3.6 V Only for NVRAM store 3.0 3.0 3.6 V VDD18 Core Voltage to Ground(a) 1.71 1.8 1.89 V TA Operating ambient temperature -40 +85 °C Oscillators fLSO Low speed oscillator (LSO) frequency(e) 32.768 kHz fHSO High-speed oscillator (HSO) frequency(e) For standard transducers, max. 2 MHz, 4 MHz For max. 4 MHz transducers 8 MHz Other frequencies in the range from 2 MHz to 8.8 MHz may be possible with limitations fSPI SPI Interface Clock Frequency(d) 8 MHz fTOF TOF measurement frequency(e) 𝑓𝑇𝑂𝐹 = 1 (𝑇𝑂𝐹_𝑅𝐴𝑇𝐸 ∗ 𝑡𝑐𝑦𝑐𝑙𝑒) 0.004 1 to 8 80(1) Hz tcycle Measurement rate cycle time(d) Measurement cycle time
1 LSB =
LP_MODE = 0: 1 ms LP_MODE = 1: 976.5625 µs 1024 1000 ms fCPU CPU clock frequency(c) Ta = 25 °C, VDD = 1.8 V 13 MHz (a) 100% production tested (b) 100% production tested at 85°C wafer sort and guaranteed by design and characterization at specified temperatures. (c) Sample tested only (d) Parameter is guaranteed by design and characterization testing (e) Parameter is a typical value only (1) Maximum value with limited functionality only, e.g. no 20 ms delay between up and down measurements.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 15 Figure 9: NVRAM Symbol Parameter Conditions Min Typ Max Unit Data Retention(d) @ 85 °C, VCC= 3.0(1) to 3.6 V 20 Years Endurance(d) @ 25 °C, VCC= 3.0(1) to 3.6 V 105 Cycles @ 85 °C, VCC= 3.0(1) to 3.6 V 104 Cycles (1) Lower limit of 3.0V is valid only for STORE. Can be lower during operation without store.
5.1 Ultrasonic Frontend
Figure 10: Ultrasonic Frontend Symbol Parameter Conditions Min Typ Max Unit Output Voltage High(d) Signal Offset = ½ VCC ±¼ VCC ±½ VCC (1) V Received Signal Amplitude at COMP_IN w/o PGA(d) Signal Offset = VREF ±100 ±400 ±VREF mV Received Signal Amplitude at COMP_IN with PGA(d) Signal Offset = VREF ±100 ±400 ±600 mV Accuracy, Amplitude Measurement(e) ±10 (2) mV VFHL_STEP Input Offset/Level Step size (e) At COMP_IN 0.879 mV VFHL_LEVEL Limits(d) At COMP_IN 0 175 mV VREF Reference Voltage(e) 0.7 V Transducer Interface Impedance (selectable by TI_PATH_SEL)(e) TI_PATH_SEL = 01 TI_PATH_SEL = 10 TI_PATH_SEL = 11 550 350 214 Ω Ω Ω ffire Typical Fire buffer frequency(d) 0,04 4 MHz gPGA PGA gain (selectable by PGA_TRIM)(d) 1MHz @ 25 °C 2MHz 4MHz 2.0 2.1 2.2 17.3 14.4 8.4 V/V en PGA Noise, referred to input(e) 10kHz to 500MHz 70 µVrms VOS PGA output offset voltage(e) After auto-zero 1 mV
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 16 Symbol Parameter Conditions Min Typ Max Unit Comparator input offset voltage (calibrated by Zero(e) Cross Calibration) < 1.6 mV (1) Without external load (2) Only for measurements on settled maximum of amplitude plateau
5.2 Time-to-Digital Converter
Figure 11: Time Measuring Unit (VCC = 3.0 V, Tj = 25 °C) Symbol Parameter Conditions Min Typ Max Unit LSB TDC Resolution(e) LSB (output format) Single-shot @ 4 MHz HSO @ 8 MHz HSO ps tm Measurement range(d) TOF measurement 10 1000 µs tm Measurement range(d) Temperature interface measurement 10 1024 µs
5.3 Temperature Measuring Unit
Figure 12: Temperature Measuring Unit (VCC = 3.0 V, Tj = 25 °C)(1) Symbol Parameter Conditions Min Typ Max Unit Resolution RMS(e) PT500, PT1000 17 Bit Gain-Drift(2) vs. VCC PT500, PT1000 0.01 %/V Gain-Drift(2) vs. Temperature(e) PT500 PT1000 < 4 < 2 ppm/K Initial Zero Offset(e) Tref <→ (Tcold, Thot) PT500 PT1000 < 40 < 20 mK (1) 2-Wire measurement with compensation of Rds(on) and gain (Schmitt trigger). All values measured at Cload = 100 nF for PT1000 and 200 nF for PT500 (C0G-type) (2) Compared to an ideal gain of 1.0
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 17
5.4 Supply Voltage Measuring Unit
Figure 13: Supply Voltage Measuring Unit Symbol Parameter Conditions Min Typ Max Unit Measurement Range(d) 2.15 3.725 V Resolution(e) 1 LSB 25 mV Accuracy(d) Ta = 25 °C Ta = whole range ± 50 ± 150 mV
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 18
6 Timing Characteristics
At VCC = 3.0 V ± 0.3 V, ambient temperature -40 °C to 85 °C unless otherwise specified. Figure 14: Oscillator specifications Symbol Parameter Min Typ Max Unit fLSO (e) 32 kHz reference oscillator at frequency fLSO 32.768 kHz tLSO_ST (e) 32 kHz oscillator start-up time after power-up < 1 Sec. fHSO (e) High-speed reference oscillator at frequency fHSO 4 (8) 8 MHz tHSO_CER_ST (e) Oscillator start-up time with ceramic resonator < 100 µs tHSO_CRY_ST (e) Oscillator start-up time with crystal oscillator (not recommended) 3 ms fPS_CLK (e) Power supply clock. Used during power on to release cyclic measurement and for watchdog 8.7 kHz Information We strongly recommend using a ceramic oscillator for HSO_CLK, because a quartz oscillator needs much longer time to settle than a ceramic oscillator. This consumes a lot of current, but using a quartz oscillator has no advantage when high speed clock calibration is done as supported by AS6031. Figure 15: Power-on Timings Symbol Parameter Min Typ Max Unit tVDD18_STB (d) Time when VDD18 is stable after power on of VCC (CL=100µF on VDD18_OUT) 20 ms tRC_RLS (d) Time when remote communication is released after power on of VCC (POR in analog and digital part finished) 37 94 ms tMC_RLS (d) Start-up time after power-on. Time before cycle measurements are released 85 °C 1.42 1.63 s 25 °C 2.09 -40 °C 3.63
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 19 Information During Power-on time, excess currents in the mA-range have to be considered. VCC and VDD18 have to be 0V before applying the supply voltage (e.g. in case of battery change).
6.1 SPI Interface
Figure 16: SPI Timings Symbol Parameter Min Typ Max Unit fSCK Serial clock frequency 8 MHz tSCK Serial clock time period 125 ns tpwh Serial clock, pulse width high 0.45 * tSCK ns tpwl Serial clock, pulse width low 0.45 * tSCK ns tsussn SSN enable to valid latch clock 0.5 * tSCK ns thssn SSN hold time after SCK falling 0.5 * tSCK ns tpwssn SSN pulse width between two cycles tSCK ns tsud Data set-up time prior to SCK falling 5 ns thd Data hold time before SCK falling 5 ns tvd Data valid after SCK rising 25 ns The serial interface is SPI compatible, with clock phase bit =1 and clock polarity bit =0. It’s strongly recommended to keep SSN = HIGH when SPI interface is in IDLE state. Figure 17: SPI Write tsussn tpwh tpwl tpws sn tsud thd MSB LSB SSN SCK SI ths sn PIN: SSN SCK MOSI tSCK
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 21 Figure 20: 2-wire Master Interface Timing A detailed description of the 2-wire interface is given in section 10.4 2-wire Master Interface. SCL SDA Sr tSU_ST A tSU_ST O SDA S tHD_ST A 1/fSCL tHIGH tVD_DATtSU_DAT SCL 9 th clock P StHD_DAT tHD_ST A GPIO1/3 GPIO0/2 PIN e.g.: GPIO GPIO PIN e.g.:
Typical Operating Characteristics Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 22 Figure 21: Typical Current Consumption vs. Sample Rate (VCC = 3.0V, PGA gain 2V/V, TOF 75µs, no CPU, CPU w. simple FW for phase jump detection, CPU with complex flow firmware) 0,0 5,0 10,0 15,0 20,0 25,0 0 2 4 6 8 10 12 14 16 Supply Current [µA] Sample Rate [Hz] Icc [µA] vs. Sample rate [Hz] CPU off CPU on PhJD CPU on Flow
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 23
8 Functional Description
8.1 System Concept
AS6031 is a complete ultrasonic flow converter (UFC) to measure and calculate the flow in a time-of- flight based ultrasonic water or heat meter. This includes the driver for the piezoelectric transducers, the analog switches, the programmable gain amplifier and the offset stabilized comparator, the CPU to calculate the flow, the clock control unit and, above all, the measure rate control and task sequencer unit. AS6031 is an autonomous system, with the task sequencer managing the complete measurement sequence independently from an external CPU. It can be used as a pure font-end with time of flight information as an output. But by means of the internal CPU the time information can be converted into a flow calibrated information already. A major reason to go with this concept is that the AS6031 covers the complete ultrasonic flow measurement task, but doesn’t touch all the other tasks of the central microcontroller. The user therefore has high flexibility in the choice of the central microcontroller and can even go with the same used e.g. for mechanical meters. On the other hand, the user does not need to step into design of electronics for ultrasonic flow but can setup a meter in a short period of time. Figure 22: Application Diagram Flow Meter Flow Meter Flow Sensors Microcontroller Connectivity Ultrasonic Converter AS6031 Power Management Piezo Spool piece Battery NFC Wireless M-BUS NFC Antenna
169 MHz
Light & Color LDODC DCPMIC Interfaces M-Bus Environmental Sensors Pressure Memory Temperture = Offered by ams
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 24
8.1.1 Measuring Principle
The AS6031 measures flow by measuring the difference in time-of-flight (TOF) of ultrasonic pulses which travel with the flow (downstream) and opposite to the flow (upstream). For water meters, water temperature can be calculated from the time-of-flight data, too. For heat meters, a high-precision temperature measurement unit is integrated. Figure 23: Principle of Ultrasonic ToF Flow Measurement The flow speed v at a given cross section area is a measure for the actual flow through the spool piece and integrating the flow over time yields the flow volume. The task of AS6031 is to handle complete process, driving the transmitting piezoelectric transducer, that generate the ultrasonic burst, measuring the receiving transducer with respect to time-of-flight and amplitude, eventually doing a temperature measurement, and optionally do the complete post- processing for flow calculation.
8.2 Functional Blocks Overview
The AS6031 is made of the following major blocks:
- Ultrasonic frontend (UFE) for ultrasonic flow measurement and temperature measurement including programable gain amplifier
- Digital core with the supervisor and task sequencer, the frontend processing unit, the CPU and memory.
- Digital I/O section
- Power supply
- Oscillator drivers US_DOWN US_UP US_DOWN US_UP
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 25 Figure 24: Major Functional Blocks of AS6031
8.2.1 Operating Modes
The AS6031 is designed for autonomous operation, with all processes, including flow calculation, being managed by the AS6031. But it may be used as pure front end, too.
- Flow Meter Mode: In the self-controlled flow meter mode, the supervisor triggers all measurements and the CPU does data processing to deliver processed results, independent from any external control. A bootloader, executed in the ROM of the integrated CPU, takes care of the application setup. A programmed firmware, also executed in the integrated CPU, defines the post processing. The interrupt may wake up an external microcontroller, so that it can read out the data.
- Time Conversion Mode: Alternatively, the AS6031 can act as a pure converter that controls the measurement, but provides pure time-of-flight data, without any data processing (time conversion mode, self-controlled). The external microcontroller takes care of the application setup and post processing. For debugging, an external microcontroller can trigger individual tasks remotely by SPI interface commands (time conversion mode, remote controlled). Application Setup The application setup of AS6031 hardware is defined by two sections in the register area: LSO Ultrasonic Frontend (UFE) Temperature Interface Ultrasonic Interface Amplitude Zero Crossing PGA Digital Core TPI_M2_B TPI_M2_A TPI_M1_B TPI_M1_A TPI_REF TPI_CLOAD TPI_GND1 TPI_GND2 US_UP_P US_DOWN_M US_DOWN_M US_UP_M US_DOWN US_UP US_VREF RECEIVE_SIG INVERT_IN PGA_OUT COMP_IN Supervisor / Task Sequencer CPU Front-end Processing Memory HSO Digital IO Power Supply VDD18_IN XIN_4MHZ XOUT_4MHZ GND XIN_32KHZ XOUT_32KHZ TEST_MODE_PS TEST_RST SSN MOSI SCK MISO INTN GPIO0 GPIO1 GPIO2 GPIO3 GPIO4 VDD18_OUT LP_MODE GPIO5 VCC
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 26
- Configuration registers (CR) (0x0C0 – 0x0CE)
- System handling registers (SHR) (0x0D0 – 0x0DD) Both register sections will be reset after the execution of a “System Reset”.
8.3 Digital Core
The digital core is made of the following sub-blocks:
- Supervisor with task sequencer, timer unit, measure rate generator and pulse interface control
- Frontend processing with control of the ultrasonic and temperature frontends, the TDC and the high-speed clock calibration
- CPU and memories for optional post-processing
- The multiple port interface for SPI communication, 2-wire master interface and pulse interfaces
- Supply management with reset management, clock management and power management
- Interrupt and error handling
- Common system bus Figure 25: Digital Core Remote Interface & GPIO Select Pulse Interface Control Remote Command Decoder RAM 176 * 32 Register Area 64 * 32 Digital Core Supervisor Frontend Processing CPU & NV Memories Multiple Port Interface Random Access Area Interrupt & Error Handling Timer Unit Measure Rate Generator Task Sequencer Ultrasonic Measurement Frontend Control Ultrasonic Measurement TDC Control Temperature Frontend & TDC Control TDC CPU Clock Management HS Clock Calibration Control FW Data Memory NVRAM 128 * 32 Program Memory Remote Access Reset Management Clock Management Power Management Supply Management Program Memory Unit System Bus Select spare 16 * 32 spare 64 * 32 C P FW Code Memory NVRAM 2k * 8 C P System Bus Access Bus Master Control Remote Memory Access System Bus Access SPI Slave Controller spare 56k * 8 FW Code Memory NVRAM 2k * 8 ROM Code Memory ROM 4k * 8 Instruction Decoder Program Counter Incl. PC Stack ALU CPU Core System Bus Access I2C Master Controller Frontend core Supply Interfaces Ultrasonic Interface Temperature Interface TDC Interface Remote Interface GPIO ACP 8 * 32
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 27
8.3.1 Reset Management
Resets in AS6031 are initiated by turning on the power supply, by the watchdog or via remote interface commands. Figure 26: Reset Distribution Following resets can be distinguished:
- PO_RST Power-On Reset of AS6031, generated by power supply. Only performed after VDD33 is switched on. Resets complete AS6031 including digital IOs. After a PO_RESET, the measurement cycle timer is disabled for typically 2s until the settling time for the LSO has expired. Top Level & Analog Part SPI CommandPower Supply Watchdog Remote Interface PO_RST WD_SYS_INIT RC_SYS_RST SHR_SYS_RST RC_SYS_INIT Multi-IO Ports Level Shifter Digital Core (special part) SHR_RC_RLS (0x0DF) Status Reg (MPI) Time Stamp Counter Digital Core (register part) CR Register (0x0C0-0x0CE) SHR Register (0x0D0-0x0DB) (0x0DD) Digital Core (main part) SHR_RC (0x0DE) SHR_CPU_REQ (0x0DC) Frontend Processing CPU Supervisor (incl. Task Sequencer) LSO Settling Timer NVRAMs SHR_SYS_INIT
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 28
- RC_SYS_RST Remote Command System Reset, performed after sending a remote command 0x99. Resets the complete digital part of AS6031. Note: Applicable only during debugging, not for application
- SHR_SYS_RST System Reset performed by writing a ‘1’ to SHR_RC[14] (Address 0x0DE) if appropriate release code is written before to SHR_RC_RLS (Address 0x0DF). Preferably initiated by CPU to allow a system reset by FW execution. Resets main & register part of digital core. Resetting only the main part of the digital core, without configuration registers, is done the following way:
- WD_SYS_RST Watchdog System Reset, performed after the watchdog timer expired. Triggers a SYS_INIT but leaves registers and memory unchanged.
- RC_SYS_INIT System Init by remote command, performed after sending the SPI remote command 0x9A. Preferred remote action if register part of digital core is wanted to be untouched. The different parts of AS6031 are reset as follows:
- Top Level and Analog Part:
- PO_RST
- Digital Core (special part):
- PO_RST
- Digital Core (register part):
- PO_RST
- RC_SYS_RST
- SHR_SYS_RST if SHR_RC_RLS == hAF0A_4735
- Digital Core (main part):
- PO_RST
- RC_SYS_RST
- SHR_SYS_RST if SHR_RC_RLS = hAF0A_4735
- WD_SYS_INIT
- RC_SYS_INIT Following registers are separated from register part with different reset behavior
- SHR_RC_RLS (0x0DF): only by PO_RST
- SHR_RC (0x0DE): additionally by WD_SYS_INIT & RC_SYS_INIT
- SHR_CPU_REQ (0x0DC): additionally by WD_SYS_INIT & RC_SYS_INIT
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 29
8.3.2 Clock Management
AS6031 normally uses two external clocks and is equipped with pins for two external clock sources.
- LSO A low-speed clock (typically 32.768 kHz), connecting a quartz crystal at pins XIN_32KHZ & XOUT_32KHZ. This clock is the basis for the supervisor, including measure rate generator and task sequencer. It is running all the time when using normal low power mode.
- HSO A high-speed clock (typically 4 or 8 MHz), connecting ceramic resonator to pins XIN_4MHZ & XOUT_4MHZ. It is used for the frontend processing and is activated only when needed. Compared to a quartz, a ceramic resonator has the benefit of a short settling time which saves power consumption. On the other hand, the clock needs to be calibrated periodically versus the LSO quartz.
- Alternatively, active external clock can be fed into the XOUT pins (XIN pins need to be grounded then). Note: In addition, there is an internal low speed oscillator PS_CLK of typ. 8.7 kHz which is used for the power-up timing to release measurements and for the watchdog. We distinguish the following clock operation modes: Low Power Mode AS6031 is sourced by the external low-speed oscillator (LSO). This is the standard in typical applications. Figure 27: Connecting Oscillators in Low Power Mode Ceramic resonator f = 4 MHz/8MHz R = 560 kΩ C = 10 pF LSO HSO XIN_4MHZ XOUT_4MHZ XIN_32KHZ XOUT_32KHZ LP_MODE Quartz f = 32.768 kHz R = 10 MΩ C = 10 pF VCC or N.C.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 31 The register SRR_HCC_VAL (High-Speed Clock Calibration Value) is updated. The value is eight times the real frequency at the TDC: 8 * fHSO / Hz. Nominal value with 250ns period: 32,000,000 (0x1E84800) Nominal value with 125ns period: 64,000,000 (0x3D09000) Example with real value from SRR_HCC_VAL, e.g. 249.9579ns: 32,005,389 (0x1E85D0D) Correction factor: 32,000,000/32,005,389 = 0.999832, to be used for all further timing calculations in any post processing. The status flag HCC_UPD in SRR_FEP_STF (Frontend Processing Status Flags) indicates whether the content is updated or not. Relevant Registers The table below lists most important registers and parameters for setting the clock management. Figure 30: Clock Control & Status Registers Register Parameter Description CR_CPM (Clock- & Power- Management) HSC_CLK_ST High-speed clock settling time (77µs, 107µ, …, 5ms) 135µs is a good value for ceramic oscillators. HSC_RATE Sets the calibration rate of HSO versus LSO (off, every 2nd , …,every 100th). HSC_DIV High-Speed Clock Divider 0: HSC_CLK not divided 1: HSC_CLK divided by 2 Optionally with HSC_DIV_MODE = 1: Only applied to low speed clocking & frontend control HSC_DIV_MODE High speed clock divider mode 0: all HSC clock dividers controlled commonly by HSC_DIV 1: HSC clock dividers individually configurable (bit 8:5) SHR_EXC (Executables) HSO_CLR Clears the high-speed oscillator (typically used by firmware code for I2C handling) HSO_REQ Requests the high-speed oscillator (typically used by firmware code for I2C handling) SHR_RC (Remote Control) HSO_MODE High Speed Oscillator Mode (for debugging only) 00: No change of HSO_MODE state (WO) 01: HSO controlled as configured 10: HSO always on 11: No change of HSO_MODE state (WO) HSC_DIV_STATE Info only, set by HSC_DIV in CR_CPM 00, 11; not possible 01: HSC_DIV = 0 10: HSC_DIV = 1 SRR_FEP_STF (Frontend Processing Status Flags) HCC_UPD Indicates whether the clock calibration value is updated or not.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 32 Register Parameter Description SRR_HCC_VAL (High-Speed Clock Calibration Value) HCC_VAL High-speed clock calibration value. = 122.0703125/THSO*216 SRR_MSC_STF (Miscellaneous Status Flags) HSO_STABLE Flag for the end of the high-speed oscillator settling time, indicating that high-speed oscillator is settled and stable. For CPU handling the flag CPU_SFLAG_HSO_ST_TO is preferred. SHR_CPU_REQ CPU_SFLAG_HSO_ST _TO 0: High speed oscillator not in timeout condition 1: High speed oscillator in timeout condition Cleared by HSO_CLR in SHR_EXC Same as HSO_STABLE but updated and valid only while CPU is running (synchronized by CPU clock)
8.3.3 Measure Rate Generator
The measure rate generator supplies up to 8 different measure task requests, which can trigger the task sequencer. The task sequencer is a state machine and then manages the processing of the measurement tasks, based on the measure cycle timer and the measure rates. The measure rate cycle time (MR_CT) is the central clock in the measure rate generator. Figure 31: Cycle Times for Tasks (example) Task Cycle Time(1) Typical setting Comment MR_CT 125 8 Hz base frequency TOF TOF_RATE × MR_CT × TMCT TOF_RATE 1 8 Hz flow measurement AM AM_RATE × TOF_RATE × MR_CT × TMCT AM_RATE 1 Amplitude measurement performed with every time of flight measurement AMC AMC_RATE × AM_RATE × TOF_RATE × MR_CT × TMCT AMC_RATE 50 Amplitude measurement calibration rate VM VM_RATE × MR_CT × TMCT VM_RATE 100 Voltage measurement every 12.5s TM TM_RATE × MR_CT × TMCT TM_RATE 240 Temperature measurement every 30s HSC HSC_RATE × MR_CT × TMCT HSC_RATE 100 High-speed clock calibration every 12.5s ZCC ZCC_RATE × MR_CT × TMCT ZCC_RATE 100 Zero-cross calibration every 12.5s (1) LP_MODE = 1: TMCT = 976.5625 µs Relevant Registers The following table lists the most important registers and parameters for setting the measure rates.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 33 Figure 32: Measure Rate Settings Register Parameter Description CR_CPM (Clock- & Power- Management) HSC_RATE High-speed clock calibration rate CR_TPM (Temperature Measurement) TM_RATE Defines the number of sequence cycle triggers between sensor temperature measurements [0=off, 1 to 1023]. CR_USM_PRC (Ultrasonic Measurement Processing) ZCC_RATE Zero-cross calibration rate [0=off, 1, 2, 5, 10, 20, 50, 100]. CR_USM_TOF (Ultrasonic Measurement Time of Flight) TOF_RATE_INIT Initial value of TOF rate after autoconfiguration of bootload CR_USM_AM (Ultrasonic Amplitude Measurement) AM_RATE Amplitude measurement rate [0=off, 1, 2, 5, 10, 20, 50, 100]. AMC_RATE Amplitude measurement calibration rate [0=off, 1, 2, 5, 10, 20, 50, 100]. SHR_TOF_RATE (Time Of Flight Rate) TOF_RATE Rate of flow measurements [0=off, 1 to 63]. In multiples of 976.5625µs/1ms.
8.3.4 Task Sequencer
The task sequencer triggers the various measurement tasks and calibration tasks. It also triggers the post processing. The task sequencer has two operation modes:
- 1-phase mode: All measurements follow the same trigger. Post-processing can be triggered by the flow measurement and the other measurements.
- 2-phase mode: Flow measurement and temperature measurement are triggered by separate triggers, called A and B. The 1-phase mode is the preferred one when working with CPU post processing or when no temperature measurement is done. The idle time for communication with an external partner is maximized. The 2-phase mode is needed in time conversion mode (no CPU post processing) with temperature measurement active. The reason is that for flow and temperature the same frontend data buffer is used. 1-Phase Mode All measurements tasks are triggered by the same single trigger. Following applications are covered:
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 36 Task Comment Time[ms] Frontend processing Typically not with every measurement Temperature measurement Typical time for an internal + 2-ports/2-wire measurement with a pause time of 10 ms 16 High-speed clock calibration Maximum time if high-speed clock calibration is performed in this cycle 0.5 Zero-cross calibration Maximum time if zero-cross calibration is performed in this cycle 0.5 CPU post processing Maximum time for a firmware execution with 4000 cycles and recommended CPU speed 0.5 SPI Remote communication Maximum time for an SPI communication of 100 bytes payload at 8 MHz and an inter-byte gap of 1µs 0.2 Total 45.5 NVRAM related tasks: NVRAM Check Recommended with CPU processing. 8.6 NVRAM Recall Timer triggered in larger intervals 0.4
8.3.5 Initial Start / Restart
The initial start sequence is performed after a power-on reset. The restart is performed after sending the remote command RC_SYS_RST or setting SHR_SYS_RST. Figure 38 shows the sequences. Cyclic measurements are released earliest after the start-up timer, based on the internal power supply clock (PS_CLK, typ. 8.7 kHz) has reached its timeout. Communication is possible as soon as the POR of the analog and digital par have been finished. Measurement Start in Flow Meter Mode A measurement start in flow meter mode requires that an executable firmware (FW code & FW data) is programmed to device with enabled “Autoconfig Release Code”. Then the measurement starts automatically without any interaction via remote interface as soon all steps are performed as described in flow diagram above. In case that firmware data enables interrupt for “Bootloader Finished”, this interrupt should be served by remote controller to release interrupt handling for all other kind of interrupt requests which follow. Measurement Start in Time Conversion Mode A measurement start in time conversion mode typically requires that “Autoconfig Release Code” is disabled. Further interactions via remote interface have to be performed as follows:
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 37 1. Wait on interrupt INTN 2. Check interrupt flag on reading SRR_IRQ_FLAG, bit 2, BLD_FNS opcode0x7A 0xE0, read data (Bit 2 of 32) 3. Clear interrupt flag register by sending RC_IF_CLR, opcode 0x8D 4. Write Configuration Data to CR addresses 0x0C0 to 0x0CB and SHR addresses 0x0D0 to 0x0D2 / 0x0DA to 0x0DB opcode 0x5A 0xC0, 0xXXXXXXXX … 0x5A 0xD0, 0xXXXXXXXX … 5. Set Measure Cycle Timer On RC_MCT_ON, opcode 0x8B 6. Check if Cycle Timer is on with RC_READ_STATUS 0x8F, bit 4, MCT_STATE Figure 37: Start / Restart Timings Symbol Parameter Min Typ Max Unit tPOR_RST Power-on reset, based on PS_CLK 37 94 ms tNVRAM_RF Refreshing NVRAM 0.36 0.36 ms tbottload_comp Complete bootload time, FW Init not considered 11.84 19.66 ms tbottload_min Minimized bootload time 0.11 0.14 ms tconf_remote Remote configuration time, based on SPI:CLK. @ fSPI = 1 MHz, byte gap = 2 µs 0.91 ms tinitial_calib Initial calibration time (Typical configuration) 4.82 4.88 ms
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 38 Figure 38: Start / Restart Sequence
8.4 Ultrasonic Frontend (UFE)
The ultrasonic frontend is made from the following sub-blocks:
- Fire buffers and switches to drive transducers in voltage mode
- Programmable amplifier in the receive path Power On Ready for Communication Refreshing NVRAMs Power-on Reset Autoconfig Release Code ? Starts LSO Startup Timer Complete Bootload Auto-Configuration Firmwar Check Firmware Initialization yes no Cyclic Measurement [INTN] INTN Remote Configuration Register Configuration Measure Cycle Timer ON System Reset Bootload START Bootload END Minimized Bootload Bootload END Configured and Ready for Cyclic Measurement LSO Startup Timeout Reached Intial Calibration (HSO & ZCL)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 39
- Zero-crossing detection circuit
- Amplitude measurement circuit
- Switching network to measure one or two external temperature sensors in 2-wire or 4-wire mode The AS6031 is designed for autonomous operation. The individual measurement tasks are triggered by the Measure Rate Generator. The individual tasks (like flow, amplitude, temperature) are controlled themselves by individual sequencer units. Figure 39: Ultrasonic Frontend Block The transducers are driven by the voltage applied at VCC. The ultrasonic transducers are directly connected to pins US_UP (against the flow) and US_DOWN (with the flow). The resistors in the transducer driver path are integrated in AS6031. There are two fire buffers, one with 350 Ohm and one with 550 Ohm. Having both in parallel the resistance is 214 Ohm. Ideally, the impedance is in the same order as the impedance of the transducer to get maximum acoustic power out of the transducers.
8.4.1 PGA (Programmable Gain Amplifier)
AS6031 has an integrated amplifier with programmable gain in the receive path. This allows to amplify the receive signal with a gain depending on the frequency. US_DOWN US_UP Vref PGA RECEIVE_SIG INVERT_IN PGA_OUT COMP_IN VREF V_ZCD Peak Vref Zero Corss Det. AmplitudeUFE FIRE Vref US Front End LV 550R 350R 1M0
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 41 In case the receive signal is strong enough, the PGA may be disabled to save current, setting PGA_MODE = 0 and bit 29 in register 0x0CE = 1 (to make RECEIVE_SIG accessible). With the PGA being disabled, it is necessary to connect the RECEIVE_SIG and COMP_IN pins. Figure 42: Wiring with PGA disabled Relevant Registers Figure 43: PGA Registers Register Parameter Description CR_USM_AM (Ultrasonic Amplitude Measurement) PGA_TRIM PGA_MODE 0 to 7: 2V/V to 19V/V PGA dis-/enabled
8.5 Ultrasonic Flow Measurement
8.5.1 Flow Measurement Sequence
The AS6031 manages the complete process of flow measurement, with special control of power consumption. All relevant elements, like high-speed oscillator, PGA, comparator and TDC as well as CPU, are active only for the period they are needed. This brings down the typical power consumption to the lowest possible level. The following graph shows a complete flow measurement task with its sub-processes. PGAINVERT_IN PGA_OUT V_ZCD Zero Corss Det. Stop_TDC 1k5 to 350k 1k5 RECEIVE_SIG COMP_IN
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 42 Figure 44: Timing Diagram Flow Measurement The ultrasonic flow sequence is made of the following steps: Figure 45: Flow Measurement Sequence & Parameters Step Register Parameter
0 General settings:
CR_CPM (Clock- & Power- Management) BF_SEL sets the base frequency for the time interval between up and down measurement, as used by USM_PAUSE. According to the power net frequency, it is set to 0 := 50 Hz or 1 := 60Hz. Having a period in multiples of this frequency helps to suppress ripple voltage. TI_PATH_SEL sets transducer fire buffer impedance: 01:= 550 Ohm; 10:= 350 Ohm; 11:= 214 Ohm CR_MRG_TS (Measure Rate Generator & Task Sequencer) MR_CT defines the measure rate cycle time. In low-power mode, this is in multiples of 976.5625 µs, as derived from the 32768Hz LSO. 0 := disabled 1 to 8191 := Cycle time = MR_CT x 976.5625 µs (LP_MODE = 1) The cycle time needs to be as short as the period of the most frequent task. In water this would be e.g. 125ms for an 8 Hz flow measurement. TS_PP_F_EN turns on post-processing directly after the US flow measurement (flow meter mode). With TS_MCM = 1, set TS_PP_F_EN = 0 and use TS_PP_T_EN only, With TS_MCM = 0, use TS_PP_F_EN = 1 to evaluate flow results before they are overwritten by an (optional) subsequent sensor measurement TS_PP_T_EN turns on post-processing as last state of the task sequencer. CR_USM_PRC (Ultrasonic Measurement Processing) USM_DIR_MODE defines which fire buffer fires first in a flow measurement sequence. 00 := Always starting firing via UP-buffer (against the flow), 01 := Always starting firing via DOWN-buffer (with the flow) 1x := Toggling sequence with every ultrasonic measurement. This option is best to compensate for temperature drift within a measurement. A temperature drift and therefore a speed of sound change between up and down measurements will give an error. If the following measurement the error has the opposite sign when the sequence has opposite order. So, in average, the error is compensated.
1 Turn-on HSO and wait until the HSO has settled (start-up time)
US_UP US_DOWN COMP_IN Amplitude measurement CPU post processing Interrupt Remot communication Direction Receive enable USM_PAUSE, typ. 5 to 20ms HS_CLK_ST, typ. 104µs USM_NOISE_MASK_WIN
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 43 Step Register Parameter CR_CPM (Clock- & Power- Management) HSC_CLK_ST defines the turn-on or settling time for the high-speed oscillator. To save current, the HSO turns on only for the TOF measurement. As the resonator needs time to establish the oscillation, there is a delay before the fire buffer send. The delay can be set in steps of 77µs, 104µ, 135 µs, 196 µs, 257 µs, 379 µs, 502 µs, ~5000 µs. b010 := 135 µs is a good setting for ceramic resonators. Bigger delays will increase current. 5ms would be needed only for quartz oscillators. 2 Turn-on PGA and PGA Vref, turn on the comparator and set the zero-cross offset voltage, typically 700mV plus maybe the offset. Regulate the offset and apply . CR_USM_PRC (Ultrasonic Measurement Processing) USM_RLS_MODE distinguishes between “First hit only” and “Release delay”: 0 := Start hit release condition by First hit only 1 := Start hit release condition by Release delay CR_USM_AM (Ultrasonic Amplitude Measurement) PGA_MODE enables the PGA. 0 := disabled, 1 := enabled. IN case the internal PGA is disabled, RECEIVE_SIG and COMP_IN need to be connected. Alternatively, an external amplifier can be connected. PGA_TRIM sets the gain of the PGA via trim bits in steps of (DC gain) The final gain depends on the fire frequency due to the limited bandwidth of the PGA. At 1 MHz the gain is about 17V/V. ZCD_FHL_INIT FWD copy of initial value for first hit levels Only important if autoconfig release code is set. Then, during the boot process, the according FWD cell content is copied into this register (with no further effect) but also into the register SHR_FHL_U & SHR_FHL_D from which first hit levels are supplied for dynamic operation
3 Send fire burst
CR_USM_FRC (Ultrasonic Measurement Fire & Receive Control) TOF_HIT_MODE: The multi-hit mode defines whether the individual TOF data in the frontend buffer are according to a uniform receive burst (1, GP30 compatible) or a split burst. When set = 0 the 10 individual ToF data will be subsequent or split in three blocks. FBG_CLK_DIV is the clock divider for fire burst generator. Frequency = High speed clock divided by FPG_CLK_DIV 0,1: not allowed, 2 to 127: divided by 2 to 127 FBG_PHASE_INS defines the phase shift in case MH-MODE is set to 0.
1 LSB: 1/(2 * f(HS_CLK)),
0 := 2 LSBs, 1 := 2 LSBs, 2 to 255 := 2 to 255 LSBs FBG_MODE defines whether the inserted phase is low (0) or high (1) FBG_BURST_PRE / FBG_BURST_POST define the number of pulses in the initial sequence /ending sequence of the fire burst (0 to 63) Further details can be seen in section Multi-hit Modes 4 Receive enable. The receive path is not open instantly but after a defined window, relative to the fire burst. This allows to suppress any noise in between fire burst and receive signal. CR_USM_PRC (Ultrasonic Measurement Processing) USM_NOISE_MASK_WINOW defines the window as long any signal (e.g. noise) is masked on the receive path. The start time refers to the rising edge of 1st fire pulse. Offset: -0.4 μs, 1 LSB := 1 μs Typically the mask window ends close to the receive burst, but with enough margin to not end in the receive burst over the whole operating range. Note that, especially at high gain, the end of the noise mask window can cause distortions which should be masked by using a correspondingly configured start hit delay window.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 44 Step Register Parameter Receive burst detection: The receive burst detection includes several tasks.
- Identification of the Start hit in the burst by means of first-hit level and / or release window
- Do the ToF measurements according to the multi-hit mode setting
- Pulse-width measurement of the 1st hit and Start hit
- Sample & hold the amplitude before ToF measurement ends, then measure after the ToF measurement the discharge time to get a measure of the amplitude. For details about start hit modes and multi-hit modes please see the separate sections Start Hit Modes and Time-of- Flight Measurement CR_USM_PRC (Ultrasonic Measurement Processing) USM_TO defines the timeout limit for the ToF measurement. In case there is no water, or one of the transducers is broken, no receive signal will be seen. To limit the time and also the current, a timeout window can be set accordingly. It should be as short as possible due to the geometry and operating range. 00 := 128 μs 01 := 256 μs 10 := 1024 μs 11 := 4096 μs CR_USM_TOF (Ultrasonic Measurement Time of Flight) TOF_HIT_START defines the number of hits, including the first hit, before a TOF measurement is done by the TDC 0 is not allowed, 1 is not recommended 2 to 31 SHR_USM_RLS_ DLY_U (Ultrasonic Release Delay Up) USM_RLS_DLY_U defines the delay window in up direction, after which start condition for multi-hits is released. The start time of the delay window refers to rising edge of the 1st fire pulse 1 LSB: 7.8125 ns (TYP) This window could be set e.g. in the part of the receive burst where the amplitude reached a stable value. It can also be used to mask distortions before the receive burst appears. SHR_USM_RLS_ DLY_D (Ultrasonic Release Delay Down) USM_RLS_DLY_D does the same in down direction Pulse width measurement: The pulse width ratio is an indication of how close the initial offset of the comparator is to the peak of the first hit. If active, the pulse width of the first hit (offset VFHL > 0) is measured as well as the pulse width of the Start hit ( (offset VZCD = 0mV) are measured, the ratios for up and down are calculated and stored as ultrasonic pulse width ratios in data buffers FDB_US_PW_U and _D. This information can be used to do a first-hit level regulation. A good value is in the order of 0.6 to 0.7. In case the ratio exceeds the limits the first-hit level should be adjusted. Wrong readings of the pulse width are often caused by misinterpretation of noise or distortions before the receive burst as first hit. In such cases, use the delay windows to filter. CR_USM_AM (Ultrasonic Amplitude Measurement) PWD_EN enables the pulse width detection (1 := active). For further details see section First Hit Detection.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 45 Step Register Parameter Amplitude measurement. The amplitude measurement starts with sample & hold of early amplitudes, beginning with the first wave. The number can be configured and is set relatively to the first hit. The conversion then, a discharge time measurement, starts after the end of the TOF measurement. For reference, in a calibration task the discharge times of two fixed voltages are measured. The features are:
- True peak amplitude measurement with every TOF (configurable)
- Highly reliable bubble and aging detection
- Very good consistency check in comparison to first hit detection
- Easy quality check in production and development
- Configurable number of hits to stop the amplitude measurement – this allows to measure the peak amplitude of each single wave at the start of the burst signal (but only one single value in each TOF measurement) The raw data are stored in the front-end data buffer in nanoseconds format: FDB_US_AM_U ≡ 𝐴𝑀𝑈𝑝[𝑛𝑠] FDB_US_AM_D ≡ 𝐴𝑀𝐷𝑜𝑤𝑛[𝑛𝑠] FDB_US_AMC_VH ≡ 𝐴𝑀𝐶ℎ𝑖𝑔ℎ[𝑛𝑠] FDB_US_AMC_VL ≡ 𝐴𝑀𝐶𝑙𝑜𝑤[𝑛𝑠] Note: during operation, the relative time information is fully sufficient for amplitude comparisons and there is no need to calculate the voltage. For the calculation of the amplitude in mV see appendix Amplitude Calculation. CR_USM_AM (Ultrasonic Amplitude Measurement) AM_PD_START_MODE defines when the amplitude peak detection starts. 0 := 10 us after the noise mask window expired. 1 := after the ultrasonic release delay expired. This is recommended, as the noise mask window also switches from fire to receive, which may generate a peak itself. AM_PD_END defines the end of the peak detection in number of hits after ultrasonic release condition. 0, 31 := not allowed 1 to 30 := after 1 to 30 detected hits Measure in opposite direction With the end of the amplitude measurement, the measurement in one direction is finished. The measurement in the opposite direction follows after some time. This period is ideally in multiples of the power net frequency to suppress noise. With USM_PAUSE = 0 only one measurement will be done. The full actions from above apply to this second measurement. CR_USM_PRC (Ultrasonic Measurement Processing) USM_PAUSE defines the pause time between two ultrasonic measurements. The typical setting is 1.0 * T(BF_SEL)= 20ms for 50Hz power net and 16.66ms for 60Hz power net, for optimal noise suppression 000 := no pause, only 1 measurement is done, in the direction set in USM_DIR_MODE 001 := not allowed 010 := 0.25 * T(BF_SEL) 011 := 0.5 * T(BF_SEL) 100 := 1.0 * T(BF_SEL) 101 := 1.5 * T(BF_SEL) 110 := 2.0 * T(BF_SEL) 111 := 2.5 * T(BF_SEL) In flow meter mode, the CPU will start post processing as soon as the measurement has finished. Therefore, the chip needs a firmware. Users can write their own firmware, based on our sample code. Or they may use AS6031 with the ScioSense flow calculation code for water meters. At the end of the processing, the firmware has to set back the watchdog and to set the interrupt. CR_MRG_TS (Measure Rate Generator & Task Sequencer) TS_PP_F_EN:= 1 enables the post-processing after an ultrasonic flow measurement use only with TS_MCM = 0 to evaluate results before they get possibly overwritten TS_PP_T_EN:= 1 enables the final post-processing at the end of the task sequence Set interrupt Depending on configuration, the interrupt is set by end of the task sequencer (time conversion mode) or by the firmware (flow meter mode).
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 46 Step Register Parameter CR_IEH (Interrupt & Error Handling) IRQ_EN_TSQ_FNS :=1 sets the interrupt pin with the end of the task sequencer (time conversion mode or flow meter mode) IRQ_EN_FW_S :=1 sets the interrupt pin by the firmware, synchronized with firmware. (flow meter mode only; can be used to get an interrupt only on request, see below) An external controller can send command RC_COM_REQ to AS6031 to request a remote An external controller can send command RC_COM_REQ to AS6031 to request a remote communication at an arbitrary time. This causes that COM_REQ will be set in register SRR_MSC_STF. By polling this status flag, the firmware is able to trigger remote communication by setting FW_IRQ_S as described below. SHR_EXC (Executables) FW_IRQ_S, 1:= Requests a firmware-triggered interrupt, synchronized with the task sequencer Remote communication With the interrupt pin being set, the remote controller can start communication. For details on the remote communication see section Remote Communication (Opcodes) Note: Avoid TOF timeout lower than fire burst length and avoid TOF timeout lower than Noise_Mask_Win. Otherwise TOF Timeout error is set and the USM sequence is not aborted after TOF timeout. TOF timeout has to take as much time as fire pulses or Noise Mask time is set.
8.5.2 Time-of-Flight Measurement
The AS6031 is based on TDC (time-to-digital converter) technology and uses a precise zero-crossing detection of the individual waves of the receive pulse to determine the travel time of the ultrasonic burst. To trigger not on any noise peaks in between fire and send pulse, AS6031 has three methods implemented:
- A first hit level detection implemented, which identifies the receive burst by setting a trigger level for the receive signal. Once the signal surpasses this level, the comparator level is set back to zero. This works fine with fast rising receive signals. It is supported by pulse width measurement and amplitude measurement.
- A delay window can be set to suppress any triggers. This window needs to be adjusted continuously to handle temperature drifts. This method may be sufficient in stable systems like heat meters, with slow amplitude variations and stable flow.
- New: Phase insertion in the fire burst. The phase jump can be detected in the receive data and gives a unique identification of the position within the receive burst.
- When signal frequencies approach half of the HSO frequency (e. q. 2 MHz signals when using a 4 MHz HSO) it is mandatory to introduce ignored hits. In such cases, the internal arithmetic unit is not fast enough to do all necessary calculations for each single hit, so at least every second hit must be ignored.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 47
8.5.3 Multi-hit Modes
For the zero-cross detection itself, AS6031 has two multi-hit modes:
- Uniform burst: This is compatible to TDC-GP30. After first hit-level detection or release delay window opening, a set number of subsequent zero-crossings is measured. TOF_HIT_MODE = 1 adjust the TOF data output in the FDB up to 10 subsequent ToF data.
- Split burst: In this mode, in addition a phase shift is introduced. The fire burst is made of two sequences, separated by a phase shift defined through FBG_PHASE_INS.
- TOF_HIT_MODE = 0 The ToF data are also split, in three segments to identify the phase jump. Uniform burst (GP30 compatible) The following diagram shows in detail the receive signal and in multi hit mode TOF_HIT_MODE = 1, which is compatible to TDC-GP30. Note: In this mode, TOF_HIT_MODE =1, it is mandatory to set TOF_HIT_END =127. Figure 46: Time-of-flight measurement Receive signal First hit level Noise Amplitude sample&hold Amplitude conversion Zero crossing level First hit level reached, comparator offset set to 0mV Start counting peaks for amplitude measurement End of amplitude peak detection: - AM_PD_END sets number of hits after 1st hit level detection Start TOF measurement: - USM_RLS_MODE=0: TOF_HIT_START sets the number of hits after first hit level was reached - USM_RLS_MODE=1: USM_RLS_DLY_U and USM_RLS_DLY_D sets the delay window after which next detected hit is defined to TOF start hit. Starting time of delay window refers to rising edge of 1st fire pulse - TOF_HIT_IGN sets the number of multi hits ignored between two hits taken for TOF measurement Comparator has an offset: - ZCD_FHL_U, ZCD_FHL_D set the offsets in up/down Original fire burst: - FBG_CLK_DIV sets the fire frequency - FBG_BURST_PRE sets the number of pulses for the burst TDC-Trigger End of TOF measurement starts amplitude conversion TOF_HIT_START Start hit for for TOF measurement relative to 1st hit TOF_HIT_SUM_NO Number of TOF hits, e.g. 10
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 48 Split burst (phase insertion) In AS6031 a new additional method for burst identification is implemented, called phase insertion. The fire burst splits in two parts, an initial sequence and an ending sequence. Each part has its number of pulses, and the inserted phase can be set to a phase shift defined through FBG_PHASE_INS While the piezo oscillation transits from the imposed initial sequence to the ending sequence, a deviation in the periods of the receive burst can be observed. The beginning of this deviation has a fixed relation to the phase shift in the fire burst and therefore can be used to identify the position of the hit numbers. With TOF_HIT_MODE = 0, the TDC measures the set number of TOF hits, three additional hits following, and additional four hits starting with the end of multi-hit setting. In the front-end data buffer, the user can read
- US_TOF_SUM_OF ALL _U/D, Sum over all hits as set in TOF_HIT_SUM_NO
- The first three hits, US_TOF_0_U/D, US_TOF_1_U/D and US_TOF_2_U/D
- Additional three hits after the number of hits set for multi-hit, US_TOF_3_U/D, US_TOF_4_U/D and US_TOF_5_U/D
- Four additional hits, beginning with the hit as set in multi-hit end, TOF_HIT_END. Following figures show a typical sequence. Figure 47: Split Fire Burst FIRE 1 19 51 Fire burst settings , e.g.: 19 pulses phase insertion 5 pulses initial sequence 1.25 µs ending sequence
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 50 Register Parameter Description TOF_HIT_END Defines the hit, counted from the Start hit, that triggers the multi-hit end sequence 1 to 127 TOF_HIT_IGN Number of ignore hits between two hits taken for TOF measurement. Must be set to 1 or higher if incoming multihits has a shorter distance than 400ns ( > 2.5 MHz receive burst frequency) Calibration of Zero Crossing Detection The zero line of the receive signal is structurally given by the hard-coded Vref level (typically 0.7 V). The zero cross detection level VZCD is the corresponding reference level of the comparator and is defined in register SHR_ZCD_LVL. To ensure that the comparator correctly detects zero crossings of the signal, VZCD has to be calibrated to Vref regularly. Basically, this compensates the offset of the comparator. The calibration is automatically done once after power-on, and then at a rate defined in register CR_USM_PRC, ZCC_RATE. In typical applications it is sufficient to do the zero-cross calibration with every 100th cycle, having ZCC_RATE = 7. The calibration automatically updates the value in SHR_ZCD_LVL, such that the user does not need to take any action. Note that the value in SHR_ZCD_LVL may be changed by the user, but such changes are overwritten by the next comparator offset calibration, except ZCC_RATE = 0.
8.5.4 Start Hit Modes
To do a time-of-flight measurement, the received signal needs to be identified and its arrival time needs to be measured thoroughly. This can be done by defining a first wave which results in a first hit, and then counting subsequent hits and storing the relevant arrival times. This is elaborated in the following manner: The receive signal, typically a burst-like signal, is converted into a digital signal using an internal comparator. While receiving, the reference voltage of the comparator most of the time equals the zero line of the receive signal to identify zero crossings (Actually, the zero line is the overlaid reference voltage Vref, and the comparator’s reference is set to the zero cross detection level VZCD, which is calibrated to Vref). This way, received wave periods are converted into digital hits. To determine an absolute numbering of the hits, a so-called first hit is defined by adding a well-defined voltage level, the first hit level (VFHL), to the comparator’s reference. This first hit detection, at a comparator level which differs from the zero-cross level, is implemented to make the time-of-flight measurement independent from temperature and flow. The offset level VFHL practically represents the level of receive signal at which the first hit is detected, which generates the first hit. After the first hit was detected, the comparator’s reference is brought back to zero cross detection level (VZCD) at the 2nd hit, and the subsequent hit measurements are done at zero crossing. The following parameters define the first hit detection and the TOF hits:
- The trigger level ZCD_FHL, which defines the comparator offset level VFHL
- The count number of the first subsequent TOF hit (Start hit) which is actually measured
- The number of measured TOF hits
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 51
- The interval between measured TOF hits
- The ultrasonic release delay: This delay disables hit detections for some defined lead time. It enables to suppress noise, in addition to the noise mask Figure 50: First Hit Level Detection Starting the measurement with the comparator offset VFHL different from zero, e.g. 100 mV, helps suppressing noise and allows the detection of a dedicated wave of the receive burst that can be used as reference. Once this first wave is detected, the offset is set back to the zero cross detection level VZCD. It is recommended to start actual TOF hit measurements after at least two more wave periods. The maximum value for the VFHL is 175 mV. AS6031 allows to set different first hit levels for up and down measurement. This allows to handle transducer pairs with different amplitudes. This e.g. appears if the sensors are pressure sensitive and there is some pressure loss across the measurement path. The combination will lead to different amplitudes in up and down direction with increased flow. In general, the first-hit level method needs a fast increase of the receive burst’s amplitude. In other words, it is not suited for high-Q transducers that take a long time for settling, because then the clearance (amplitude difference from wave to wave) is not sufficient. Pulse Width Measurement The information of pulse width is used to monitor how close the first hit level is to the margins. Therefore, the device measures the pulse width of the first hit, with the comparator being at the first-hit level. This is compared with the pulse width of the Start hit, where the comparator is at zero cross level. By nature , the ratio is less than one. If the amplitude decreases at a given first hit level, the pulse width will decrease, too. At the point when the amplitude of the current wave falls below the first hit level, the next wave will be taken for first hit. The pulse width ratio will jump from a very small value to a high value. Low Q = wide bandwidth = fast rise time = big clearance First hit level Clearance High Q = narrow bandwidth = slow rise time = small clearance First hit level Zero cross level Clearance COMP_OUT COMP_OUT COMP_OUT Phase jump
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 53 Register Parameter Description SHR_ZCD_LVL (Zero Cross Detection Level) ZCD_LVL Zero Cross Detection Level 1 LSB: ~ 0.88 mV SHR_FHL_U (Zero Cross Detection Level) ZCD_FHL_U First Hit Level Up 1 LSB ~ 0.88 mV, maximum 175mV SHR_FHL_D (First Hit Level Down) ZCD_FHL_D First Hit Level Down 1 LSB ~ 0.88 mV, maximum 175mV Release Window Only Some applications may use transducers with high Q = narrow bandwidth, with the disadvantage of a very slow settling time. This ends with very small amplitude differences from peak to peak, which makes it difficult to use first-hit level detection. In this case, a fixed but programmable window can be used that releases the TDC input after a fixed but programmable time. The time starts with the first fire pulse and can be programmed for up and down direction independently. The precision of the 19-bit values is 1LSB = 7.8125 ns with 4MHz. Register SHR_USM_RLS_DLY_U Parameter USM_RLS_DLY_U Register SHR_USM_RLS_DLY_D Parameter USM_RLS_DLY_D The challenge here is to track and control the window by software to cover drifts over temperature (speed of sound). Following figure shows the situation with release window instead of first-hit level detection.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 54 Figure 54: Release Window Combination First Hit Level plus Release Window Ideally, the first hit level detection is combined with release window. This combination can be activated in configuration register CR_USM_PRC (Ultrasonic Measurement Processing), setting bit USM_RLS_MODE = 1 and having a first hit level FHL ≥ 0. TOF_HIT_START is counted after the first hit level detection before the start hit is taken. The release window should be set to the lowest time-of-flight possible over the whole temperature range. This window will suppress noise in advance to the receive burst. Note that the noise mask window switches between send and receive path. Switching the capacitive load will generate noise or oscillations with the noise mask opening. By means of the release delay the first hit level detection will work properly. The right choice for TOF_HIT_START depends on which zero crossing is the first to be sufficiently stable and low noise for taking it into account. Summary Global settings: TOF_HIT_START ≥ 2 (in CR_USM_TOF[5:1]) Receive signal First hit level = 0 Noise Zero crossing Multi-hit released, TOF measurements possible Start TOF measurement. Comparator has zero offset from the beginning USM_RLS_DLY_U and USM_RLS_DLY_D define the windows to block measurements, beginning with the first fire pulse TDC-Trigger Release window TOF_HIT_START: Start hit for for TOF measurement relative to Release delay
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 55 Figure 55: Start Hit Modes USM_RLS_MODE USM_RLS_DLY_U/D FHL Start Hit Mode / Release Event Comment 0 = 0 > 0 First hit detection only / First hit Start hit = TOF_HIT_START hits after first hit detected Independent from temperature, but sensitive to noise from noise mask opening. Noise mask FHL TOF_HIT_START Start hit x RLS_DLY TOF Noise mask, >TOF = 0 Release delay only / Release delay RLS_DLY within the receive burst, needs to be adjusted with temperature Start hit = TOF_HIT_START hits after release window opening Noise mask RLS_DLY Start hit xTOF FHL TOF_HIT_START Noise mask, < TOF > 0 Combined / First hit RLS_DLY shortly before the receive burst (to suppress noise as generated by the noise mask switching) Start hit = TOF_HIT_START hits after first hit detected No need to adjust the RLS_DLY with temperature due to FHL Noise mask RLS_DLY Start hit x FHL TOF_HIT_START TOF
8.5.5 Amplitude Measurement
The amplitude measurement is done by a single slope AD-conversion of a stored peak amplitude value. In practice, this means a sample & hold detector stores the amplitude peak value during the measurement interval (between the first wave and the configured end of the measurement) in a capacitor. This capacitor is then discharged at a constant current down to Vref, which yields a discharge time measured by the internal TDC. The amplitude measurement has its limitation especially at high fire frequencies (> 1MHz) because the sample circuit can’t follow the amplitude fast enough. Therefore, the measured amplitude for the first
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 57 Register Parameter Description AM_PD_START_MODE 0: AM peak detection starts 10 µs after noise mask window expires 1: AM peak detection starts after ultrasonic release delay expires Suitable only for combined start hit mode, when ultrasonic release delay is configured between end of noise mask window and ultrasonic receive burst The resulting measurements are then stored as raw TDC values in the frontend data buffer. The format of the TDC values is 32-bit data with 1 LSB: 1/ 216 * tperiod(HSO), tperiod(HSO) = 250 ns at 4 MHz, = 125 ns with 8 MHz. Figure 58: FDB in case of ToF Addr Name(1) Value Description 0x082 FDB_US_AM_U AMup Ultrasonic Amplitude Value Up 0x083 FDB_US_AMC_VH AMChigh Ultrasonic Amplitude Calibrate Value High 0x086 FDB_US_AM_D AMdown Ultrasonic Amplitude Value Down 0x087 FDB_US_AMC_VL AMClow Ultrasonic Amplitude Calibrate Value Low Those time data are converted into voltage by means of the formulas given in appendix 15.6. It is, however, not necessary to calculate actual amplitudes in mV since the measured time values themselves can be used for relative amplitude comparison. In this case, the calibration values are used in reverse way to derive time values for amplitude comparison, for example from given limits. While the amplitude measurement is repeatable and stabilized through calibration, it is still not a high- precision measurement. In the final measurement result an offset of a few mV typically remains, that also depends on the fire frequency. Since amplitude measurement always starts at the first wave, it should be clear that the result can never be smaller than the first hit detection level VFHL. Note that the peak detection can be configured to end at any hit after start condition (first hit level or hit release delay). This way it is possible to measure the peak amplitudes of receive burst hits during its rise individually. Of course, this requires several separate measurements with different configurations. As an alternative, the amplitude measurement can be stopped after the first wave already, and the first hit level is then increased in steps of 1mV. The resulting data can be used as basis for the selection of the right first hit level.
8.6 Temperature Measurement
AS6031 has a highly accurate interface for resistive temperature sensors. All these resistive measurements are based on discharge time measurements, using a fixed load capacitor and discharging this one sequentially through the sensor resistors and a reference resistor. The sensors’ resistance is defined by calculating the ratio of sensors’ discharge time and reference resistor’s discharge time.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 58 The unit can handle various modes, based on following possible configurations:
- An internal temperature sensor with 3000ppm/K and an internal reference with100ppm/K
- 1 or 2 external temperature sensors in 2-wire or 4-wire connection For precision temperature measurement with mK precision, as needed in heat meters, platinum resistors (PT500 or PT1000) are recommended. The external load capacitor should be of C0G material. X7R will need more fake measurement to get into a micromechanical stable mode. Heat meters will need two sensors, for hot water (incoming) and cold water (outcoming). Water meters will need a temperature sensor only in case of hot water meters with temperatures above 60°C. In cold water meters the temperature can be calculated from the sum of time-of-flight. The mode selection will define the sequence of the activation of the internal switches. This includes also compensation measurements that correct for Rds(on) (switch resistance) and gain (comparator delay). 2-wire measurements are good for sensor temperature measurements or other resistor measurements with medium accuracy demands. They require calibration for their offset resistances. 4-Wire measurements are more accurate but require the according 4-Wire sensor cabling. 4-wire measurements compensate for cable and connection resistance. This is preferred in case of screwed or plugged sensor connections. This mode achieves a mathematical precision of 10mK. Attention Note. Both methods cannot compensate for variations in cable capacitance. Therefore, the AC- based measuring unit cannot be used for long cables (> 1.5m ). Information In case the temperature measurement unit is not used, we recommend connecting a standard 100nF capacitor to pin TPI_CLOAD. All other pins may be left not connected. 8.6.1 2-Wire Temperature Mode In 2-wire temperature mode, the temperature interface does a sequence of resistor measurements at the external ports, for 1 or 2 sensors and for the reference resistor. The sensors are connected to the chip as drawn in the next figure:
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 60 Addr Name Unit Seq. Time Description 0x083 FDB_TPM1_M2A_G12 tM2A Temperature port M2-A 0x084 FDB_TPM1_RA_G12 C tRdson RDSON compensation 0x08E FDB_TPM2_M1AB_RAB_G12 C tgain Gain compensation 0x08F FDB_TPM2_RAB_G12 tRAB Reference port REF-AB 0x090 FDB_TPM2_M1A_G12 T tM1A Temperature port M1-A 0x091 FDB_TPM2_M2A_G12 tM2A Temperature port M2-A 0x092 FDB_TPM2_RA_G12 C tRdson RDSON compensation The raw results given here are raw TDC values. They can be converted to actual times by multiplying with tHSO/216. But since in the final calculation only ratios of values will be used, this conversion into time is not needed. tM1A, tM2A and tRAB correspond to the total resistance values of the measured network, including internal switch resistances. To remove the influence of switch resistances and comparator delay, measurements tRdson "and" tgain should be used according to the following equations(1): Rds(on) correction (the correction of switch resistances) 𝑡𝑅𝑂 = 𝑡𝑅𝑑𝑠𝑜𝑛-𝑡𝑅𝐴𝐵 Schmitt trigger delay compensation(2) 𝛥𝑡 = 2𝑡𝑔𝑎𝑖𝑛 − 2 𝑡𝑀1𝐴 𝑡𝑅𝐴𝐵 𝑡𝑀1𝐴+𝑡𝑅𝐴𝐵 Note that the Schmitt trigger delay compensation requires a measurement of the cold sensor. In case one sensor may be optional, always use the hot sensor for the optional one. Reference: 𝑡𝑅 = 𝑡𝑅𝐴𝐵 − 𝑡𝑅𝑂 − 𝛥𝑡 Sensor Cold: 𝑡𝐶 = 𝑡𝑀1𝐴 − 𝑡𝑅𝑂 − 𝛥𝑡 Hot: 𝑡𝐻 = 𝑡𝑀2𝐴 − 𝑡𝑅𝑂— 𝛥𝑡 The sensor to reference ratios are used in the following for the temperature calculation: Sensor resistance vs. reference: Cold: 𝑅𝐶 𝑅𝑅𝐸𝐹 𝑡𝐶 𝑡𝑅 Hot: 𝑅𝐻 𝑅𝑅𝐸𝐹 𝑡𝐻 𝑡𝑅 (1) The calculation assumes that all double switches are identical, and that the measurements are linear and repeatable. Under these conditions, the sensor network resistances are measured to the accuracy of the reference resistor, with an uncertainty through added noise of ±0.001 % of full scale. Additional line resistances in the sensor networks can’t be calibrated out by 2-Wire measurements. If the line resistances are known from different measurements, they may simply be subtracted from the result in a separate calibration. (2) The calibration measurement for comparator delay uses the cold sensor. If the cold sensor path is unusable, for example due to some damage, also the hot sensor path can’t be fully calibrated. So, if only one sensor is used, always use the cold sensor pins, and if one sensor result is needed with high accuracy, even in case the other sensor may be damaged, connect the more important sensor to the cold sensor ports The calculation of temperatures from resistance values is done as usual through the sensor’s characteristic T(R) curve. For convenience, there are ROM routines (15.5.4) implemented to do the calculation by means of a polynomial of second degree or simply by a linear approach. The polynomial resembles the inverted R(T)-polynomial for PT (according to IEC 60751:2008) within 0°C and 100°C.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 61 Equation ROM_TEMP_POLYNOM: 𝑇𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑒 𝑇[°𝐶] = 10.115 × ( 𝑡𝐶 𝑡𝑅 + 235.57 × ( 𝑡𝐶 𝑡𝑅 ) − 245.683 Format: fd16 8.6.2 4-Wire Temperature Mode In 4-wire temperature mode, the temperature interface does a much more complex sequence of resistor measurements in different configurations. The set of measurements allows an accurate determination of the sensor resistance of one or two 4-wire sensors. In contrast to the 2-wire measurement, every single switch resistance of different pins can be calculated from these measurements. This is important, since every pin may be connected to the sensor over a different line resistance. There is no assumption about similar switches or similar line lengths. This makes this measurement method particularly suitable for high-accuracy measurements using connectors or other network elements that may suffer from aging. The sensors should be connected to the chip as drawn in then following figure: Figure 61: Temperature sensor, 4-wire connection In case only one 4-wire sensor is used, connect its two ground cables separately to TPI_GND1 and TPI_GND2. Rhot Rcold PCB VCC TPI: Temperature Interface TPI_M2_B TPI_M2_A TPI_M1_A TPI_M1_B TPI_REF TPI_CLOAD TPI_GND1 TPI_GND2 AFE Rref Cload RMI_R RMI_M A B
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 62 The complex mathematics of the 4-wire measurements is fully covered by the applied firmware. Therefore, we do not provide a more detailed description. The applied firmware writes the results of the temperature measurement to RAM cells 0x020 to 0x024: Figure 62: Applied Firmware Temperature Result Registers Addr Name Description Format 0x020 RAM_R_PTC_TEMPERATURE Cold sensor temperature [°C] fd16 0x021 RAM_R_PTH_TEMPERATURE Hot sensor temperature [°C] fd16 0x022 RAM_R_PTC Cold sensor resistance fd16 0x023 RAM_R_PTH Hot sensor resistance fd16
8.6.3 Internal Temperature Measurement
A simple temperature measurement is possible through a build-in temperature-sensitive resistor and a temperature independent resistor. Figure 63: Internal Temperature Sensor The internal temperature measurement can be used solely or in combination external temperature sensors in 2-wire connection. A measurement sequence looks like the following: VCC TPI: Temperature Interface TPI_CLOAD AFE Cload PCB RMI_R RMI_M
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 63 1. 2 fake measurements. The capacitor is discharged but without any time measurement. This is to stabilize the load capacitor. They are followed by the first measurement M1. 2. tMI_M is measured by closing the switch for the internal measurement resistor 3. tMI_R is measured by closing the switch for the internal reference resistor 4. tMI_g for the gain compensation is measured by closing both switches. 5. Repetition of sequence 2. To 5. In reversed order. The results of the 3 measurements are stored in the frontend data buffer: Figure 64: FDB in case of Internal Temperature Measurement Addr Name Unit Seq. Description 0x085 FDB_TPM1_MI_R_G12 I 1 Internal temperature reference 0x086 FDB_TPM1_MI_RM_G12 Internal temperature compensation 0x087 FDB_TPM1_MI_M_G12 Internal temperature measurement 0x093 FDB_TPM2_MI_R_G12 I 2 Internal temperature reference 0x094 FDB_TPM2_MI_RM_G12 Internal temperature compensation 0x095 FDB_TPM2_MI_M_G12 Internal temperature measurement The internal temperature measurement utilizes an internal reference resistor with a nominal value of 1.265 kΩ at room temperature and a temperature coefficient of -0.1 Ω/K, and a sensor resistor with the same nominal resistance value, but a different temperature coefficient of 3.7 Ω/K. Due to chip tolerances, this measurement will not be very accurate. Under the assumption that the combined temperature coefficient of the resistance ratios is known as 3.8 Ω /K, a simple calculation can be done when a measurement at known chip temperature is performed: 𝑇 = ( 𝑡𝑀𝐼_𝑀 𝑡𝑀𝐼_𝑅 𝑡𝑀𝐼_𝑀(𝑇0) 𝑡𝑀𝐼_𝑅(𝑇0)) ∗ 1.265kΩ 3.8Ω/K + 𝑇0 Due to chip tolerances, at least one calibration measurement at some temperature T0 is recommended. It is actually sufficient to assume 𝑡𝑀𝐼_𝑀(𝑇0) 𝑡𝑀𝐼_𝑅(𝑇0) = 1 and to adjust the constant T0 in the upper equation for the correct result. More elaborate calibrations and calculations are possible. However, the internal temperature sensor is not accurate enough to justify that effort. It would also be possible to find an individual value for the internal sensor’s temperature coefficient, but that would require a measurement at different temperatures. Nevertheless, with the simple calibration described above the internal temperature sensor can reach accuracies down to a few centigrade, which is good enough for some applications.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 64
8.6.4 Technical Properties of the Temperature Interface
The temperature interface performs resistance measurements by discharging a capacitor, which was loaded to the supply voltage VCC, over the unknown resistor network, down to some fixed comparison voltage. Each temperature interface pin contains a double switch which connects this pin to Cload (the temperature measurement load capacitor on pin TPI_CLOAD). Through different switch settings, all necessary measurements are done in a well-controlled measurement sequence. The measurement sequences are hard-coded for 2-wire and 4-wire sensor case. Details on the sequences have been discussed above. Figure 65: Voltage Cload with Internal Temperature Measurement In idle state the CLOAD port is connected internally to VCC. Externally the pin may be not connected. Measurement range and selection of load capacitor One discharge cycle takes a time of about 𝜏 = 0.7 × 𝑅 × 𝐶𝑙𝑜𝑎𝑑 This makes e.g. 70 µs for a 1 kΩ resistor R and a 100 nF capacitor Cload. The value of Cload and the range of R has to be chosen such that actual measurement times are between 10 µs (limited by the internal TDC calibration time) and the discharge cycle time minus the capacitor recharge time. The discharge cycle time tdct can be chosen to 512 µs (recommended) or 1024 µs.respectively (TM_CYCLE_SEL in CR_TM set to 0 or 1, respectively). The capacitor recharge time can be estimated as 𝜏𝑟𝑒 = 10 × 10Ω × 𝐶𝑙𝑜𝑎𝑑 for highest accuracy permit 3 × 𝜏𝑟𝑒. Typically, Cload = 100 nF is used, which permits to measure resistances between 142 Ω and about 5 kΩ (maximum measurement time 502 µs). Considerations on measurement accuracy The short times of the measurements, corresponding to high signal frequencies, have to be considered when using the temperature interface: 1st default 2nd reverse VCload Time
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 65
- Long lines can be problematic through their parasitic inductance and capacitance. When using lines in the range of meters or even above, the quality of the measurements must be checked carefully.
- In addition, long lines may introduce problems through coupled noise and EMI. It is possible to reduce such problems by using filtering elements like ferrites or small capacitors, but the possible influence of such filters on the measurement has to be considered.
- It is also recommended to use a capacitor of C0G or other class-1-type. For example, X7R- types can suffer from memory effects and, of course, from high temperature coefficients, which may reduce measurement accuracy dramatically. It is in any case recommended to control the quality of such resistance measurements in your actual measurement environment. Measurement accuracy is achieved by a suitable calibration and based on the measurement of a well- known reference resistor. The equation for 𝜏 has no guaranteed accuracy and can only be used for resistance estimations. Still, high measurement accuracy is reached by comparisons, making use of the high short-term repeatability and linearity of the single resistance measurements. Thus, a typical measurement sequence includes the measurement of a well-known reference resistor, such that actual resistance values can be calculated from the ratios of measured times 𝜏 to 𝜏𝑅𝐸𝐹, the time result for the reference resistor measurement. The accuracy of such measurements depends on the following factors:
- Absolute accuracy, temperature dependence and aging of the reference resistor is of course fully traced to the measurement result. For high quality measurements, use a reference resistor with low tolerance and low TC.
- Offset line and switch resistances. Such offset values are unavoidable, their removal requires additional calibration measurements. The following sections describe how such measurements are setup and used in case of 2-wire and 4-wire measurements. Switch resistances also add to the reference resistor measurement, typical values for switch resistances in AS6031 are below 10 Ohms.
- Linearity and repeatability of measurements: Due to a stable comparison voltage, linearity can be considered ideal. The good short-term stability of the temperature interface can even be further improved:
- All measurements needed are done in a well-controlled measurement sequence. The measurement sequences are hard-coded but can be configured as described below.
- Typically, 2 fake measurements are done before each measurement sequence. This makes sure that each relevant measurement starts in a similar condition (all measurement taken into account did have at least two similar measurements before).
- The measurement sequence can be repeated (configurable) after a fixed time of, for example, 1.5 times the base frequency period. Setting the base frequency to the local mains frequency (50 or 60 Hz) results in suppression of power line noise in temperature measurements.
- The repeated measurement sequence can be configured to be in reverse order. This removes any linear deviation trend that may appear during measurements, for example changing sensor temperature during a measurement cycle.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 66
- Finally, the noise of the TDC measurements, which are utilized for the temperature ports as well, set an absolute limit on measurement accuracy. With a typical single-shot peak noise level of about ±2.5ns, the equivalent peak noise in measured resistance ratios can be estimated as ±0.001 % of full-scale values (assuming 500us maximal measurement time). Note that this is an absolute error, such that the relative error increases for low measurement times or low resistances, respectively. Measurement run time and current consumption The total runtime tti of a temperature interface measurement sequence depends on the chosen configuration and can be calculated as 𝑡𝑡𝑖 = 𝑡𝐻𝑆𝑂 + 𝑡𝑑𝑐𝑡 ∗ (𝑛𝑓𝑎𝑘𝑒 + 𝑛𝑚𝑒𝑎𝑠 ) + 𝑡𝑝𝑎𝑢𝑠𝑒 Here, 𝑛𝑚𝑒𝑎𝑠 is the number of actual measurements (four with 1 sensor in 2-wire, five with two sensors in 2-wire, always fourteen for 4-wire case and 3 for internal measurements). 𝑡𝐻𝑆𝑂 is the configured HSO settling time, 𝑡𝑑𝑐𝑡the discharge cycle time (512 or 1024 µs), 𝑛𝑓𝑎𝑘𝑒 =2 or 8 the number of fake measurements and 𝑡𝑝𝑎𝑢𝑠𝑒 the configured pause time (could even be 0, then the measurement sequence is not repeated). Example: The total runtime of a 4-wire 2-sensor measurement with 2 fake measurements, at 135 µs HSO settling time and 512 µs discharge cycle time and with 30 ms pause time is 38.33 ms. If a firmware is used to evaluate the results, about 0.5 ms runtime is added. It should be clear that the total measurement time is dominated by the pause time. Note that the pause time starts together with the first measurement sequence, such that the first measurement sequence takes place during pause time. Of course, the average current consumption depends strongly on the total runtime tti as well as on the temperature measurement rate or its frequency ftm, respectively. A reasonable estimation of the additional average current consumption for the temperature measurement interface Itm is 𝐼𝑡𝑚 = 0.6 µ𝐴 ∗ (𝑛𝑓𝑎𝑘𝑒 + 𝑛𝑚𝑒𝑎𝑠 ) ∗ 𝑓𝑡𝑚 ∗ 𝐶𝑙𝑜𝑎𝑑 100 nF This formula gives an upper limit for repeated measurement sequence and 512 µs discharge cycle time, the value for 1024 µs is about 15% higher. At only one single measurement sequence (tpause = 0), the actual current consumption is half of the calculated value. Example: Average current consumption for external 2-wire 2-sensor measurements with 2 fake measurements and repeated (tpause ≠ 0), at a cycle time of 125 ms and TM_RATE = 240 (ftm = 1/30 Hz) is estimated to 0.14 µA for 512 µs discharge cycle time or 0.161 µA for 1024 µs. At (tpause = 0), the result is 0.07 µA for 512 µs. Note that the current consumption does not depend on the measured resistance. Note also that a low repetition rate, as in the given example, the current consumption comes in shape of a peak at the temperature measurement frequency. It is recommended to use a 100 µF blocking capacitor on supply voltage for high quality temperature measurements.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 67
8.6.5 Relevant Registers
The table below lists most important registers and parameters for setting this multi-hit mode. Figure 66: Multi-hit Mode Relevant Registers Register Parameter Description CR_TPM (Temperature Measurement) TM_RATE Temperature Measurement Rate 0: disabled 1 to 1023: Rate related to sequencer cycle trigger TPM_PAUSE Pause time between 2 temperature measurements for 50Hz/60Hz suppression 00x: no pause, only one measurement 010: Pause = 0.25 * T(BF_SEL) ms 011: Pause = 0.5 * T(BF_SEL) ms 100: Pause = 1.0 * T(BF_SEL) ms 101: Pause = 1.5 * T(BF_SEL) ms 110: Pause = 2.0 * T(BF_SEL) ms 111: Pause = 2.5 * T(BF_SEL) ms TPM_MODE Temperature Measurement Mode 000: Off 001: Internal only 010: Internal & 2-wire/1 port 011: Internal & 2-wire/2 ports 100: 2-wire/1 port 101: 2-wire/2 ports 110: 4-wire/1 port 111: 4-wire/2 ports TPM_PORT_MODE Temperature Measurement Port Mode 0: Inactive ports pulled to GND while measurement (recommended setting) TM_PORT_ORDER Temperature Measurement Port Order 10: 1. measurement: default order / 2. measurement: reversed order (recommended setting) TPM_CLOAD_TRIM Temperature Measurement Load Trim 10: = recommended value TPM_CYCLE_SEL Temperature Measurement Cycle Select 0: 512 µs (recommended value) 1: 1024 µs TPM_FAKE_NO Number of Fake measurements 0: 2 fake measurements (recommended value)
8.6.6 Error messages
The temperature interface generates error messages, which can be read from register SRR_ERR_FLAG. There are three different error flags that may be set by the temperature interface:
- EF_TM_SQC_TMO (bit 8): Temperature Sequence Timeout. This flag is set when the first temperature measurement sequence did not finish before the end of the configured pause time. Note that this flag must be ignored when no second measurement block is configured, since then there is no pause time and the flag is always set.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 68
- EF_TM_SC_ERR (bit 4): Temperature Measurement Short Circuit. This flag is set when the load capacitor is discharged very quickly, such that within the first 1 µs of the measurement the capacitor voltage drops below VCC /2. This indicates a too low resistance, which typically happens in case of a short circuit of a sensor.
- EF_TM_OC_ERR (bit 3): Temperature Measurement Open Circuit. This flag is set when the load capacitor is not discharged to the comparison voltage level during a measurement cycle at all. This indicates a too high resistance, which typically happens in case of an open circuit, for example a loose sensor
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 69
9 Special Functions
9.1 Time Stamp (RTC)
AS6031 has a simple timestamp function with a resolution of 1 sec. The current values for hours, minutes and seconds are latched in result registers. The time stamp can be updated automatically every measure cycle trigger. But it is possible to trigger an update as well as to clear the content, both by setting executables in the special handling register SHR_EXC. Time stamp is cleared only by “Power On Reset” and therefore not influenced by any other system reset or system init. Relevant Registers The table below lists most important registers and parameters for setting the clock management. Figure 67: Relevant Registers for Time Stamp (RTC) Register Parameter Description CR_CPM (Clock- & Power- Management) TSV_UPD_MODE Time stamp update mode 0: updated by TSV_UPD in SHR_EXC 1: automatically updated with every measure cycle, use this setting SHR_EXC (Executables) TSV_UPD Time stamp value update 0: No action 1: Update time stamp value from time stamp counter TSC_CLR Time stamp counter clear 0: No action 1: Clears time stamp counter SRR_TS_HOUR (Time Stamp Hours) TS_HOUR Timestamp hours, 18-bit values, 1 LSB: 1h SRR_TS_MIN_SEC (Time Stamp Minutes & Seconds) TS_MIN Timestamp minutes, 8-bit values, 1 LSB: 1min, range 1 to 59 TS_SEC Timestamp seconds, 8-bit values, 1 LSB: 1sec, range 1 to 59
9.2 Backup
Backup handling in AS6031 can be realized by connecting an external I2C EEPROM to the GPIO Unit of the AS6031. Backup handling can be triggered by the integrated general-purpose timer, which defines the cycle time for the backup. It’s enabled if the CPU request enable CPU_REQ_EN_GP is enabled and triggered by the general-purpose timer. The backup data has to be written by firmware code to the 2-wire interface, where backup data is directly transferred to an external I2C EEPROM.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 70 For details on backup handling or different usage of the EEPROM interface please contact support. Figure 68: EEPROM Interface Figure 69: Relevant Registers for Backup Register Parameter Description CR_IFC_CTRL Register (Address 0x0C1) I2C_MODE 2-wire master interface mode, I2C like 00 & 11: I2C disabled 01: I2C enabled on GPIO 0/1 10: I2C enabled on GPIO 2/3 I2C_ADR 2-wire master interface slave address
9.3 Watchdog
After a system reset the watchdog of AS6031 is enabled. The nominal value of the watchdog time is 15.2 seconds, based on the internal oscillator clock source of 8.7 kHz. For operation in time conversion mode, it could be useful to disable the watchdog of AS6031. For that a disable code has to be written to register CR_WD_DIS. When AS6031 operates with firmware, it is good practice to keep the watchdog enabled. The watchdog timer must then be reset before the watchdog time elapsed. Otherwise the watchdog issues a system init (please compare to chapter “Reset Management”). Typically, the watchdog timer is reset in each post processing cycle by the firmware command clrwdt. The firmware can then use the watchdog for any safety mechanism where a system init is required to resolve problems, just by not resetting the watchdog timer. And of course, the system init will be triggered when the firmware does not run at all. Of course, it must be made sure that the chip starts operating as desired after a system reset, for example by a suitable configuration and setting the autoconfig release code in FWD. Measure Cycle Timer Task Sequencer Firmware Code (General Purpose Handling) General Purpose Timer External EEPRO M (I2C) Trigger Trigger General Purpose Request EEPROM Interface Write Backup Data Transfer Backup DataCPU_GPT
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 71 Figure 70: Relevant Registers for Watchdog Register Parameter Description CR_WD_DIS Register (Address 0x0C0) WD_DIS Code to disable Watchdog: 0x48DB_A399, Write only register. Status of watchdog can be checked in WD_DIS in register SRR_MSC_STF
9.4 Supply Voltage Measurement
The voltage measurement is the only measurement task which is performed directly by the supervisor and not by frontend processing. It’s automatically executed if VM_RATE > 0. The value of VCC is measured and can be compared to a low battery threshold. Figure 71: Relevant Registers for Voltage Measurement Register Parameter Description CR_CPM (Clock- & Power- Management) VM_RATE Repetition rate, every Nth measure cycle trigger LBD_TH Threshold for low-battery detection
1 LSB: 25 mV
LBD_TH = 0: 2.15 V LBD_TH = 63: 3.725 V SRR_VCC_VAL (VCC Value) VCC_VAL Measured value of VCC voltage
1 LSB: 25 mV, default 0x2F
VCC_VAL = 0: 2.15 V VCC_VAL = 63: 3.725 V SRR_ERR_FLAG (Error Flags) EF_LBD_ERR Error flag, indicates if low battery is detected
9.5 Error Handling
AS6031 features a number of hardware flags to indicate measurement errors. Some of the possible errors are related to wrong configurations, others to measurement problems. Typical error cases are TOF timeouts, when for example a water flow meter pipe ran dry and no signal was received, or a task sequencer timeout when the configured cycle time did not leave enough time to finish all tasks. Other examples would be short cuts or lost connections on temperature sensors. It is in general recommended to check error flags, with or without firmware usage, and to implement processes to resolve the indicated problems.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 73 Register Parameter Description SHR_EXC (Executables) EF_CLR Clears error flag SRR_IRQ_FLAG (Interrupt Flags) ERR_FLAG Error flag has been set SRR_ERR_FLAG (Error Flags) EF_XX_XX_XX Bits 0 to 15 indicate Error flags corresponding to error flag enable bits in CR_IEH
9.6 Cyclic NVRAM Recall
It’s recommended to perform a cyclic recall of NVRAMs, independent if operating in flow meter or time conversion mode. NVRAM recall means that memory is refreshed by transferring contents from non- volatile to volatile part of NVRAM. Figure 74: Relevant Registers for Cyclic NVRAM Recall Register Parameter Description CR_MRG_TS (Measure Rate Generator & Task Sequencer) TS_NVR_RATE NVRAM Recall Timer Rate 0000: disabled 0001: 1 sec 0010: 2 sec 0011: 5 sec 0100: 10 sec 0101: 30 sec 0110: 1 min 0111: 2 min 1000: 5 min 1001: 10 min 1010: 30 min 1011: 1 h 1100: 2 h 1101: 6 h 1110: 24 h 1111: 48 h
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 74
10 Interfaces
The UFC is able to operate in flow meter mode or in time conversion mode. In flow meter mode a remote port interface is needed to program the UFC. In time conversion mode a remote port interface is needed to configure and for measurement related communication with the UFC. The remote port interface operates as an SPI interface. Figure 75: SPI Interface Pin Name Description Comment SSN Input low active (1) MOSI Input (1) SCK Input (1) MISO Output 3-state INTN Output low active (1) For standalone operation without external controller, the unconnected inputs should be configured with internal pull up by SPI_INPORT_CFG in CR_IFC_CTRL.
10.1 Serial Interface
The SPI interface is able to operate as a slave in a multi-slave SPI bus working in SPI mode 1. Pin MISO_TXD is in high Z state when the chip is not communicating. SPI mode 1 (CPOL = 0, CPHA = 1) is defined as follows:
- Idle State of SCK is LOW
- Data is sent in both directions with rising edge of SCK. Data is latched on both sides with falling edge of SCK. Slave select (SSN) and slave interrupt (INTN) are low active. It’s strongly recommended to keep SSN = HIGH when SPI interface is in IDLE state.
10.1.1 Remote Communication (Opcodes)
Remote communication can be started within a task sequencer cycle, after frontend and post processing finished. AS6031 signalizes this instant to a remote controller by an interrupt via pin INTN.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 75 In general, it is preferred to have an interrupt-based communication. Even though there is an asynchronous communication port (ACP), any communication during a measurement can have a negative impact on the measurement quality. Generating an interrupt request for remote communication is served in following ways:
- Interrupt is automatically sent with every task sequencer cycle by enabling IRQ_EN_TSQ_FNS in CR_IEH. This is typically used in time conversion mode to allow the remote controller reading raw measurement values from frontend data buffer after each measurement.
- Interrupt is controlled by firmware. Therefore IRQ_EN_FW_S in CR_IEH has to be set. Then a synchronous interrupt can be triggered by firmware by setting FW_IRQ_S in SHR_EXC. The interrupt will appear after post processing finished. Typically used in flow conversion mode where a remote communication need not be requested with every task sequencer cycle. In case of a running firmware, it is possible to avoid permanent communication and to keep the external controller in sleep mode over long periods. Since the firmware can evaluate and store results, it does not need to communicate after each measurement. It can then be advantageous to let the external controller trigger communication: An external controller can send command RC_COM_REQ to AS6031 to request a remote communication at an arbitrary time. This causes that COM_REQ will be set in register SHR_CPU_REQ. By polling this status flag, the firmware is able to trigger remote communication as described above on request by the external controller. A remote control always starts communication with the UFC by sending a remote command RC_xx_xx as the first byte of a remote request. The following acronyms will be used: Figure 76: Acronyms Acronym Remote Command Length RC_ Remote Command 1 Byte RAA_ADR Random Access Area Address 1 Byte RAA_WDx_Bx Random Access Area Write Data ≥ 4 Bytes (4 bytes wise) RAA_RDx_Bx Random Access Area Read Data ≥ 4 Bytes (4 bytes wise) FWC_ADR FW Code Memory Address 2 Bytes FWC_WDx_Bx FW Code Memory Write Data ≥ 1 Byte
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 76
10.1.2 Reset & Inits
Figure 77: Reset & Inits Remote Command Code Description RC_SYS_RST 0x99 Resets main part of digital core including register part and triggers bootloading process Note: Applicable only during debugging, not for application RC_SYS_INIT 0x9A Resets main part of digital core without register part and triggers bootloading process RC_SV_INIT 0x9C Resets Supervisor, Frontend Processing and CPU in main part of digital core but without a bootload trigger
10.1.3 Memory Access
Figure 78: Memory Access Remote Command Code Description RC_RAA_WR 0x5A 0x5B Write to RAM or register area Write to FW data area (NVRAM) RC_RAA_WRS 0x5E 0x5F Write to RAM or register area with read system status before write Write to FW data area (NVRAM) with read system status before write RC_RAA_RD 0x7A 0x7B Read from RAM or register area Read from FW data area (NVRAM) RC_RAA_RDS 0x7E 0x7F Read from RAM or register area with read system status before read Read from FW data area (NVRAM) with read system status before read RC_FWC_WR 0x5C Write to FW code area (NVRAM) RC_RD_STATUS 0x8F Read system status only The least significant bits of remote commands RC_RAA_WR and RC_RAA_RD correlate to the most significant bit of the RAA address RAA_ADR[8]. RAA_ADR[7:0] are defined in a separate address byte. In general, it is possible to do blockwise data transfer and this is the preferred operation.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 78 Remote Request Answer RAA_RD1_B3 RAA_RDx_B0 Figure 82: RC_RAA_RDS (RAA Read in blocks with status first) Remote Request Answer Command RC_RAA_RDS Address RAA_ADR Status SYS_STATUS Read data RAA_RD0_B3 RAA_RD0_B2 RAA_RD0_B1 RAA_RD0_B0 RAA_RD1_B3 RAA_RDx_B0 Figure 83: RC_RAA_STATUS (RAA system status only) Remote Request Answer Command RC_RAA_STATUS Address RAA_ADR Status SYS_STATUS The system status bit gives quick access to important system information with read operations. Figure 84: SYS_STATUS Bit Bit Name Reset Format Bit Description
0 RAA_BUSY b0 BIT Random access area busy: Occupied system bus
1 NOT USED
3:2 MT_REQ_CTR b0 BIT Measure task request counter Implemented as gray counter: 00 -> 01 -> 11 -> 10 -> 00 ->
4 MCT_STATE b0 BIT Status of measure cycle timer
5 COM_FAIL b0 BIT Communication Failed
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 79 Bit Bit Name Reset Format Bit Description
6 RST_FLAG b0 BIT Reset Flag
7 ERR_FLAG b0 BIT At least one error flag is set
Figure 85: RC_FWC_WR (FWC Write in blocks) Remote Request Answer Command RC_FWC_WR Address FWC_ADR_B1 FWC_ADR_B2 Write Data FWC_WD0_B3 FWC_WD0_B2 FWC_WD0_B1 FWC_WD0_B0 FWC_WD1_B3 FWC_WDx_B0
10.1.4 Measure Task Request
Figure 86: Measure Task Request Remote Command Code Description RC_MT_REQ 0xDA Measure Task Request The Measure Task Request is followed by an extended command EC_MT_REQ, which defines the requested measure task(s):
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 80 Figure 87: EC_MT_REQ Extended Command Description EC_MT_REQ Measure Task Request EC_MT_REQ [Bit 0]: VCC Voltage Measurement EC_MT_REQ [Bit 1]: not used EC_MT_REQ [Bit 2]: Time Of Flight Measurement EC_MT_REQ [Bit 3]: Amplitude Measurement EC_MT_REQ [Bit 4]: Amplitude Measurement Calibration EC_MT_REQ [Bit 5]: Temperature Measurement EC_MT_REQ [Bit 6]: High Speed Clock Calibration EC_MT_REQ [Bit 7]: Zero Cross Calibration
10.1.5 Debug & System Commands
Figure 88: Debug & System Commands Remote Command Code Description RC_TSC_CLR 0x86 Time stamp counter clear RC_BM_RLS 0x87 Bus master release RC_BM_REQ 0x88 Bus master request RC_RF_CLR 0x89 Reset flag clear (RST_FLAG in SYS_STATUS) RC_MCT_OFF 0x8A Measure cycle timer off RC_MCT_ON 0x8B Measure cycle timer on RC_GPR_REQ 0x8C General purpose request RC_IF_CLR 0x8D Interrupt flags clear RC_COM_REQ 0x8E Communication request RC_FW_CHKSUM 0xB8 Builds checksum of all FW memories
10.2 General Purpose I/O Unit
The general-Purpose IO unit supports up to 6 GPIOs which can be used for different internal signals and/or interfaces. The assignment of the GPIOs has to be configured by
- GPx_DIR & GPx_SEL (x = 0 to 5) in CR_GP_CTRL
- I2C_MODE in CR_IFC_CTRL
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 81
10.2.1 General Purpose Out
Each GPIO can be configured individually as an output signal of digital part as defined below: Figure 89: GPIO as Output, GPx_DIR = b00, I2C_MODE = b00 or b11 Pin GPx_SEL 00 01 10 11 GPIO5 GPO[5] (1) TI_PGA_VREF (1) GPIO4 GPO[4] TI_VR_EN TI_PGA_EN (1) GPIO3 GPO[3] PI_DIR (1) TI_FIRE_EN GPIO2 GPO[2] PI_PULSE TI_FP_PCH (1) GPIO1 GPO[1] PI_DIR ERROR_N USM_DIR GPIO0 GPO[0] PI_PULSE LS_CLK TI_FIRE (i) For internal use only
- GPO[5:0]: General purpose outputs writable via SHR_GPO
- PI_DIR: Pulse interface direction (for more details, see section below)
- PI_PULSE: Pulse interface out (for more details, see section below)
- TI_VR_EN: Enable signal of ultrasonic transducer interface
- TI_PGA_VREF: VREF signal for PGA
- TI_PGA_EN: Enable signal for PGA
- TI_FP_PCH: Pre-Charge state of transducer interface
- ERROR_N: Error signal (low active)
- LS_CLK: Low speed clock
- TI_FIRE_EN: Busy signal of TI_FIRE
- USM_DIR: Direction signal (Down/up) of ultrasonic measurement
- TI_FIRE: Fire signal of ultrasonic measurement
10.2.2 General Purpose In
Figure 90: GPIO as Input, GPx_DIR = b01/10/11 (in), GPx_SEL != 0, 0 I2C_MODE = b00 or b11 Pin Function GPIO5 GPI[5] GPIO4 GPI[4] GPIO3 GPI[3] GPIO2 GPI[2] GPIO1 GPI[1] GPIO0 GPI[0]
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 82
- GPI[5:0]: General purpose inputs, readable via SRR_GPI
10.3 Pulse Interface
The pulse interface is a separate and independent unit connected to the GPIO block. The CPU can take any of the data, e.g. the original DIFTOF, but also the finally calculated flow information and translate this to a pulse stream. With flow as basis, this will be fully compatible to typical pulse interfaces of mechanical flow meters. Such a system might be a one-to-one replacement for a mechanical flow meter. The pulse interface generates pulses, where each pulse corresponds to a configurable flow volume (pulse valence, for example one pulse per 100 ml). The parameters of the pulse interface are configured in register CR_IFC_CTRL. The interface then operates at the configured update rate, independent of measurement interface and CPU, by generating pulses according to the actual flow volume. The flow volume must be signaled and updated, typically by a firmware running on the CPU, by updating the register SHR_PI_NPULSE or, simpler, by using the ROM routine ROM_PI_UPD. The ROM routine calculates the necessary input variables for the pulse interface from a given flow volume. If you plan to configure and update the pulse interface via remote interface by an external µController please contact support for details. The following figure gives on overview of the relevant units and variables. Figure 91: Pulse Interface: Functional Blocks and Variables Remote Interface (SPI) RAM CR_IFC_CTRL SHR_PI_NPULSE SHR_PI_TPA SHR_PI_IU_TIME SHR_PI_IU_NO Pulse Interface Pulse Direction CPU GPIO0 / GPIO2 GPIO1 / GPIO3 PI_UPD SPI
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 83
10.3.1 Configuration of the pulse output
The pulse interface outputs can be provided via GPIO0/GPIO1, optionally via GPIO2/GPIO3 (register CR_GP_CRTL). The basic configuration of the pulse interface is done in register CR_IFC_CTRL Register (Address 0x0C1), with the most important configuration variables having the following meaning: PI_OUT_MODE Selects the two possible output formats.
- PI_OUT_MODE = 0
- GPIO0 / GPIO2 = Pulse output, provides the pulses, indicating flow
- GPIO1 / GPIO3 = Direction output, provides the direction of the measured flow rate, indicating positive/negative flow Figure 92: PI_OUT_MODE = 0
- PI_OUT_MODE = 1
- GPIO0 / GPIO2 = Pulse output, positive direction, issued for flow direction forward
- GPIO1 / GPIO3 = Pulse output, negative direction, issued for flow direction reverse Figure 93: PI_OUT_MODE = 1
- PI_TPW: Pulse width in multiples of 0.97656 ms (= period of 1024 Hz generated by 32.768 kHz clock), configurable from 1 to 255 (0.97656 ms to 249 ms).
- PI_OUT_MODE and PI_TPW are initial parameters, which are typically configured once. The general FW library of UFC provide subroutines for pulse interface initialization, dependent on following application parameters:
- TOF measure cycle time GPIO0 GPIO1 PI_TPW GPIO0 GPIO1
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 84
- Pulse valence (ratio pulses/liter)
- Maximum flow 10.4 2-wire Master Interface The 2-wire master interface for an external memory extension (e.g. for backup purpose) or an external pressure sensor is a separate, independent unit, connected to the GPIO unit, which can be controlled by firmware of the integrated CPU. It is a master interface, suited for a single two-wire connection to an I2C compatible device. It works in standard mode up to 100 kHz or in fast mode up to 400 kHz (but no Schmitt-trigger inputs). It supports spike suppression on the SDA input. Clock stretching is not supported. SCL: Serial clock line SDA: Serial data line (bidirectional) The assignment of the signal lines to GPIOs can be configured by I2C_MODE in CR_IFC_CTRL as follows: Figure 94: I2C Modes I2C_MODE 00 01 10 11 GPIO0 (1) SCL (1) (2) GPIO1 (1) SDA (1) (2) GPIO2 (1) (1) SCL (2) GPIO3 (1) (1) SDA (2) (1) As configured by GPx_DIR & GPx_SEL (table at beginning of this chapter) (2) Not allowed The general FW library of UFC provide subroutines for 2-wire interface communication.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 85
11 CPU
The CPU is structured and implemented as shown in the following figure. It has access to the full RAM, including the result registers and the status registers. Figure 95: CPU Environment
11.1 Registers and Accumulators
The 32 bit-CPU operates on three internal registers, the X, Y, and Z-accumulators, and on one register or RAM cell, addressed by the CPU’s RAM address pointer. The latter register is denoted with R, it can be any accessible cell within the RAA address range. R is handled in the same way as an accumulator by most commands. One specialty of R is the byte coding and decoding by the bytesel and bytedir command, which only acts on R in read direction (details see below). This function is built in for simplified and accelerated byte operations. RAM 176 * 32 Bit Program Area Random Access Area (RAA) Firmware Data NVRAM 128 * 32 Bit not used 16 * 32 Bit Register Area 64 * 32 Bit Instruction Decoder Program Counter PC Stack 8 x not used 0x1000 – 0xEFFF Firmware Code Memory NVRAM 4096 * 8 Bit 0x0000 – 0x0FFF ROM Code Memory ROM 4096 * 8 Bit 0xF000 – 0xFFFF ALU Start/Stop Control CPU Core RAA Address Pointer ZSOC X-Reg Y-Reg Z-REG0x000 0x0B0 0x0C0 0x100 0x17F R-Reg 32 Watchdog 2-wire Interface Peripherals CPU Peripherals from instruction decoder 32 32 ACP 8 * 32 Bit 0x1C0 0x1C7
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 86
11.2 CPU Flags
The CPU uses four flags to classify the results of operations: Carry (C), equal Zero (Z), Sign (S) and Overflow (O). Zero and Sign flags are set with each CPU write access to any register, RAM or accumulator. Additionally, the Carry and Overflow flags are set in case of a calculation, shift or rotation. Flags which are not actively changed by an operation remain in their former state. It is possible to query each flag in a jump or skip instruction.
11.2.1 Carry (C)
Shows the carry over in an addition or subtraction. Note that the carry flag is calculated assuming unsigned binary numbers, in contrast to the overflow flag. Thus, it may produce confusing results, refer to the detail description of instructions for usage. With shift operations (shiftL, shiftR, rotL, shiftR.), the carry flag is set to the (last) bit that has been shifted out.
11.2.2 Overflow (O)
Indicates an overflow during an addition or subtraction of two numbers in two‘s complement representation. This is strictly an overflow for positive numbers, underflow in case of negative numbers is not indicated. If the eventuality of a negative underflow can’t be avoided, additional calculations to indicate the underflow are required.
11.2.3 Zero (Z)
The zero flag indicates if the last number written into a register (by add, sub, move, swap, etc.) was zero or not equal to zero.
11.2.4 Sign (S)
The sign flag indicates if the last number written into a register (by add, sub, move, swap, etc.) has the highest bit (MSB) set to 1 or to 0. It thus indicates the sign of this number, with zero indicated positive. The sign flag assumes a two’s complement number representation.
11.3 Arithmetic Operations
An arithmetic command processes two of the registers X, Y, Z or R, and writes back the result into the first mentioned register (or, for commands with 64-bit results, into both). These operations also affect flags of the CPU. In particular, the carry (C) and overflow (O) flags should be checked to ensure correctness of the last operation. All arithmetic operations process a 32-bit wide input, (mostly) based on the common two’s complement operations. This means that the MSB (the most significant bit of the binary word, here bit
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 87 31) defines the sign of the binary number, with negative signs having MSB=1. Number values of positive numbers are as usual, while the value of a negative number A follows the rule |A| = NOT(A) +1 , in words: negative numbers are converted into positives by bitwise inversion, and then adding 1 (see the instructions “compl” and “invert”)
11.3.1 Branch Instructions
There are 3 principles of jumping within the code:
- Goto: Jumps with relative or absolute addressing. Within an address vicinity of –128 to +127, the assembler automatically uses relative addressing (“Branch”). For wide distances, absolute addressing within the whole address space of 64 kB is automatically used (“Jump”). The latter is more flexible but needs one code byte more.
- Jsub: Absolute or relative jump, used to call a subroutine. The difference to goto is that the code returns to the calling address at jsubret (for example at the end of the subroutine). It is possible to handle 7 nested jsub. An overflow of the stack counter is indicated in CPU_ERR. When no return to the calling address is desired, it is better (and of course possible) to use goto instead of jsub.
- Skip: Suppress the execution of the next 1, 2 or 3 instructions. Note that the skipped instructions are in fact processed, but they produce no result or further activity. Thus, skip does not save processing time of the skipped instructions, in contrast to goto or jsub. However, the skip command itself is only one byte short, and in addition it is highly suitable for structured programming. Goto and skip come in different flavors, as unconditional command as well as controlled by some bit or CPU flag. Refer to the detail instruction list below for details.
11.4 Instruction Set
The complete instruction set of the AS6031 consists of 70 core instructions that have unique op-codes decoded by the CPU. The following table gives an overview of all available expressions, details are given further below. Figure 96: Instruction Set Overview Logic Simple arithmetic Complex arithmetic Flags Register-wise Jsub and abs div clrC clear jsub eor add divmod getflag move jsubret eorn compare mult setC swap invert compl nand decr nor incr
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 88 Logic Simple arithmetic Complex arithmetic Flags Register-wise Jsub or sign Logic Simple arithmetic Complex arithmetic Flags Register-wise Jsub sub RAM access Jump Skip Miscellaneous Shift & Rotate Bitwise bytedir goto skip clkmode rotL bitclr bytesel gotoBitC skipBitC clrwdt rotR bitinv decramadr gotoBitS skipBitS equal shiftL bitset getramadr gotoCarC skipCarC equal1 shiftR incramadr gotoCarS skipCarS i2crw ramadr gotoEQ skipEQ mcten gotoNE skipNE nop gotoNeg skipNeg stop gotoOvrC skipOvrC gotoOvrS skipOvrS gotoPos skipPos For a detailed description of the individual instructions see appendix 15.4 CPU Commands.
11.5 Libraries and pre-defined routines
AS6031comes with a number of predefined routines in its ROM. Some of them are ready-to-use and freely available. The ROM routines are organized in a library, defined by a so called header file which relates routine and variable names to their call addresses and memory addresses, respectively:
- common.h General purpose routines File “common.h” that comes with the assembler must be included in codes that use any of these routines (use the “include” statement in the main *.asm file). The routines are called using their ROM routine name after jsub or any goto statement. The ROM routine name is a synonym of the call address, as defined in the header file. The call address may be used alternatively. Some routines come in different alternative versions or with alternative start addresses. To some extent, this allows the user to select different RAM cells for data storage. A typical example would be a routine which needs some cells of usual RAM, and an alternative version where cells in the firmware data (FWD) range are used instead – this second one frees up RAM space and could make use of automated non-volatile storage, at the cost of firmware data space. Another reason for alternative start addresses is to skip a part of the routine if some part of the preparation work is not needed or undesired (for example when some numbers calculated at the start of the routine are already known). The differences between the versions are explained for each routine in detail in the subsequent sections.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 89 Number format: As usual in fixed decimal-point arithmetic, care has to be taken to set values in the right format. Unless differently noted, all numbers are in two’s complement (MSB determines sign). The binary representation B_bin of a fractional number is defined with a fixed number N of fractional binary digits, such that the corresponding decimal number B_dec is calculated as: B_dec = Bin_into_decimal(B_bin)/2^N. Throughout this document, such a format will be labeled “fd N” – N fractional digits. A typical value format is fd 16, covering a fractional number range from about - 32768.0 to 32768.0 (when using 32 bit RAM cells). The second factor to be considered in calculations is the unit, which in many cases comes with a fixed factor, for example whenever values are related to a particular physical value. A typical example is measured TOF time, which is always given as fd 16 in HSC periods (250 ns for 4 MHz operation). This means, the measured Time-of-flight value in time units TOF relates to the measured number TOF_bin as: TOF = (Bin_into_decimal(TOF_bin)/2^16) * 250 ns. Another example is the first hit level FHL, which is given as an integer binary number FHL_bin with an LSB of about 0.88mV: FHL = Bin_into_decimal(FHL_bin) * 0.88 mV. Due to the internal calculation processes, the range of values which generate correct results in some calculation is limited and depends on the format definition. For example, a multiplication of two 32 bit numbers always generates a correct 2*32 bit result (in two words, Y and X register). But if this result is formatted into one single word in fd 16 format (for example using ROM_FORMAT_64_to_32BIT) for further calculations, the result can only be right when the leading 16 bit of the original result where 0 (and of course, some accuracy is lost by cutting the lowest 16 bit, too). Such effects have to be considered in any routine that deals with actual calculations. Wherever applicable, number formats and additional range limitations are given in the subsequent routine descriptions. 11.5.1 common.h The general purpose routines defined in common.h are listed in the following. Note that not all of them can be used in the same code, depending on memory allocation. Some routines are included in alternative versions, to enable optimized memory usage. In the following sections, the ROM routines defined in common.h are grouped according to their usage. The table gives an overview: Figure 97: ROM-routines for common usage Name Description Remarks Filtering ROM_INIT_FILTER ROM_INIT_FILTER1 Routine to initialize the RAM cells for any filter (rolling average) with a given value ROM_ROLL_AVG Routine to filter the FILTER_IN values using a rolling average filter Filter length can be configured ROM_ROLLAVG_2OUTLIER Routine to filter the FILTER_IN values using a rolling average filter. One value which deviates most is always ignored. Filter length can be configured ROM_FILTER_FLOW Routine to filter flow values using the standard rolling average filter, including initialization. Filter length can be configured Error detection and handling
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 90 Name Description Remarks ROM_EH This routine checks all error flags and suppresses processing of wrong results. many RAM cells fixed ROM_PP_AM_MON ROM_PP1_AM_MON Monitor the amplitude values and check limits to identify bad measurements alternative calls exist ROM_PP_AM_CALIB ROM_PP1_AM_CALIB This routine gets the Amplitude Calibration values (H & L) and evaluates the gradient and offset that can be used for calculating the actual amplitude. alternative calls exist Pulse interface and flow volume ROM_CFG_PULSE_IF This routine configures the pulse interface with the parameters calculated from the given configuration. ROM_PI_UPD Pulse Interface Update Routine ROM_PP_PI_UPD Pulse Interface Update Routine with input from RAM ROM_SAVE_FLOW_VOLUME ROM_SAVE01_FLOW_VOLUME ROM_SAVE1_FLOW_VOLUME ROM_SAVE11_FLOW_VOLUME ROM_SAVE2_FLOW_VOLUME ROM_SAVE21_FLOW_VOLUME This routine is used to store the converted flow (in LPH), cumulatively to flow volume in cubic meter. alternative versions exist Sensor temperature measurement ROM_TEMP_POLYNOM Calculates the temperature of a PT sensor using a polynomial approximation ROM_TEMP_LINEAR_FN This routine is used to calculate the temperature of any sensor as a linear function of sensor resistance using the nominal resistance and sensor slope. ROM_TM_SUM_RESULT Sums up the results of double temperature measurements. The double measurements are performed to eliminate the 50/60 Hz disturbance. Interface communication ROM_I2C_ST I2C Start Byte Transfer Low-level routines, covered by the ones following ROM_I2C_BT I2C Byte Transfer ROM_I2C_LT I2C Last Byte Transfer ROM_I2C_DWORD_WR Write 4 bytes of data to a specified address through the I2C interface ROM_I2C_BYTE_WR Write a single byte of data to a specified address through the I2C interface ROM_I2C_DWORD_RD Sequentially read 4 data bytes from the I2C interface ROM_I2C_BYTE_RD Sequentially read a single data byte from the I2C interface Housekeeping ROM_CPU_CHK Check kind of CPU request: This routine is called by hardware design after any Post Processing (PP) request, it is the starting point of any CPU activity, including the firmware call at MK_CPU_REQ. automatically started ROM_USER_RAM_INIT Initialize the entire user RAM with 0 High speed oscillator ROM_HSC_CALIB This routine evaluates the high speed clock scaling factor for the 4MHz / 8 MHz clock ROM_SCALE_WITH_HSC Routine to scale the input parameter with the HS Clock Calibration factor Configuration
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 91 Name Description Remarks ROM_RECFG_TOF_RATE Routine to reconfigure TOF_RATE generator to a lower rate, depending on the parameter N Mathematics ROM_FORMAT1_64_TO_32BIT Routine to format a 64-bit value (in Y and X) into a 32 bit result with 16 integer + 16 fractional bits. Useful for formatting 64 bit multiplication results with 32 integer + 32 fractional bits alternative version: faster, but needs temporary RAM ROM_DIV_BY_SHIFT Perform the division of a value Y by X, where X=2^N is an integer power of two ROM_SQRT Evaluate the square root accurately for values in the range (196 <= X <= 5476) ROM_LINEAR_CORRECTION ROM_LINEAR1_CORRECTION Linear interpolation of a coefficient between two sampling points alternative version is fixed to inter- polation over THETA ROM_FIND_SLOPE Used to find the slope between two points, given the coefficient values and parameter values at the two points. For a detailed description of the ROM routines refer to the appendix.
11.6 CPU Handling
The CPU starts with handling a request as soon as one of the bits in the system handling register SHR_CPU_REQ is set. All bits are typically triggered by the task sequencer, the error handling, a general-purpose pin or the remote control. Post processing is enabled in register CR_MRG_TS, bits TS_PP_F_EN and TS_PP_T_EN. Error handling and general purpose handling is enabled in register CR_IEH, bit CPU_REQ_EN_GPH.
- CPU_REQ_BLD_EXC: Bootloader, triggered by task sequencer
- CPU_REQ_CHKSUM: Checksum Generation, triggered by task sequencer
- CPU_REQ_PP_F: Post Processing F, triggered by task sequencer
- CPU_REQ_PP_T: Post Processing T, triggered by task sequencer
- CPU_REQ_GPH: General Purpose Handling, triggered by task sequencer
- CPU_REQ_FW_INIT: Firmware Initialization, triggered by bootloader, cleared when CPU stops In general, sending any of these requests by task sequencer the corresponding bit in SHR_CPU_REQ lets the chip start the CPU at the appropriate position within the task sequencer cycle. CPU operation then always starts within the ROM code by checking the request. Bootloader and checksum generation requests are handled directly in ROM routines. For Firmware initialization, post processing and General purpose handling the program counter is directed to firmware code memory, starting at address
- 0x0024: With applied Empty FW
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 92
- FWCU_RNG: With applied Flow FW After the request is processed, the firmware must clear it in SHR_CPU_REQ (or simply clear the whole register after all is done), else the request remains. The following figures show the basic structure of code. Program code in white color has to be defined and programmed by customer, whereby public subroutines in the ROM code can also be used by customer. Figure 98: Code Structure, Empty Firmware 0x1000 0x0020 FWCU User Code Basic Code: Empty FW Basic Code: Empty FW FWC Memory 0x0024 ROM Subroutines for firmware and common usage Checksum Generation Bootloader ROM Check of CPU Request Start Stop Stop FWCU_RNG = 0x0FA0 0x0000 ROM Memory 0xF000
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 93 Figure 99: Code Structure, Flow Firmware The device will be offered as an option with integrated firmware, that does the complete flow calculation, but still offers the possibility to add custom made code. After a ROM check of the CPU request, the program counter is directed via basic code to the address of FWCU_RNG from where applied flow FW is executed. 0x1000 0x0020 FWCU User Code Basic Code: Flow FW Applied Code: Flow FW Basic Code: Flow FW FWC Memory 0x0024 ROM Subroutines for firmware and common usage Checksum Generation Bootloader ROM Check of CPU Request Start Stop Stop FWCU_RNG 0x0FA0 0x0000 ROM Memory 0xF000
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 94
11.6.1 Check CPU Request
In case that any of the request bits is set in SHR_CPU_REQ the CPU starts at first with code in the ROM that checks the type of request. Figure 100: CPU Request Handling(1) (1) With empty firmware In case of a post processing request, a general purpose request or a firmware initialization request the CPU is directed into firmware user code, starting from address 0x0024. This means that the user has to implement in his firmware also a CPU request check. ROM Code START [0xF000] ROM Check of CPU Request Any CPU Request set ? no yes ROM Code END Stop CPU Post Processing F Request ? FW User Code (0 x0024) Check of CPU Request Post Processing T Request ? FW User Code (0 x0024) Check of CPU Request General Purpose Handling Request ? FW User Code (0 x0024) Check of CPU Request yes yes yes no no no Bootloader Request ? NVRAM Check Request ? yes yes no Firmware Init Request ? FW User Code (0 x0024) Check of CPU Request yes no no Bootloader NVRAM Check
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 95
- Firmware initialization (FW code): Besides the configuration done by the boatloader some additional configurations can be performed, which typically are some initializations of the SHR register.
- Post Processing F (FW code): This will be the most common request, namely for data post processing of flow in case that flow and temperature measurement is enabled.
- Post Processing T (FW code): This will be the most common request, namely for data post processing like flow (if temperature measurement is not enabled) or temperature calculation.
- General purpose request handling (FW code) General Purpose Request can be triggered either triggered by GP Timer, by SHR_EXC or by CPU_REQ_GPH. For any of these actions CPU_REQ_EN_GPH has set before. In addition, CPU Request Handling processes two further requests which are performed in ROM code and are described in following sections:
- Bootloader (ROM code)
- NVRAM check (ROM code)
11.6.2 Bootloader
The bootloader is always requested after any system reset or a system INIT occurred. However, complete bootloader actions are only performed if the autoconfiguration release code is set. The Register Configuration is performed if Autoconfig Release Code (RAA address 0x16B) is set. It copies the user configuration data and the ScioSense configuration data (RAA addresses 0x16C- 017B) into CR register area (0x0C0-0x0CF). Also, the FHL is copied to SHR_FHL_U and SHR_FHL_D. Bootloader actions are:
- “Get Firmware Revisions” which set FW revisions in register SRR_FWU_REV & SRR_FWA_REV
- Check whether the release code for autoconfiguration is set (0x16B). If yes then
- Transfer of configuration data to register area
- Enabling Measure Rate Generator
- Setting “FW Init” request in SHR_CPU_REQ which is performed after bootloader sequence has been finished
- Setting NVRAM check request in SHR_CPU_REQ
- Finally, the bootloader clears the bootloader request in SHR_CPU_REQ and jumps back to ROM code for checking CPU requests. The bootloader does not set USM_RLS_DLY. This needs to be set manually or per initialization in the firmware.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 96 Figure 101: Bootloader actions
11.6.3 NVRAM Check
NVRAM check can be requested by remote command RC_FW_CHKSUM, by the checksum timer or, if autoconfiguration release code is set, it’s automatically performed after bootloader. Then the checksums of all FW areas are generated and compared to checksums which can be stored to FW Data memory. Then different FW areas are checked:
- FWCU: compared to checksum stored on address 0x100
- FWDU: compared to checksum stored on address 0x101
- Applied FW: Different areas compared to applied checksums internally Finally, the checksum generation clears its request in SHR_CPU_REQ and jumps back to ROM code for checking CPU requests. The checksum for FWCU is generated by adding read data bytewise. The checksums for FWDU is generated by reading DWORDs (32 bit) and adding read data bytewise to checksum. START Bootloader Autoconfig Release Code set ? no yes End Bootloader Clear Bootloader Request in SHR_CPU_REQ Register Configuration Enable Measure Rate Generator Set FW Init Request in SHR_CPU_REQ Set NVRAM Check Request in SHR_CPU_REQ Get Firmware Revisions
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 97 Figure 102: Relevant Registers for NVRAM Check Register Parameter Description CR_IEH (Interrupt & Error Handling) EF_EN_XX_XX_XX Bits 12 to 14 enable error flags corresponding to register SRR_ERR_FLAG 12: FWCU check failed 13: FWDU check failed 13: Applied FW check failed SHR_GPO (General Purpose Out) FW_XX_CS_ERR For more details on applied FW 12: FWCU checksum error 13: FWDU checksum error 14 to 18 Any of applied FW checksum errors CR_MRG_TS (Measure Rate Generator & Task Sequencer) TS_CST_RATE Firmware Check(sum) Timer Rate 000: disabled 001: 1h 010: 2h 011: 6h 100: 24h 101: 48h 110: 96h 111: 168h Under worst case conditions, the checksum generation can consume up to 8.6 ms. This should be considered when invoking this task timer based during measure cycle: The FW check(sum) task has to be integrated with all other measure tasks within 1 measure cycle.
11.6.4 CPU Error
As part of the error handling the CPU Error Flag indicates following error cases of CPU:
- Invalid program counter
- Stack overflow of program counter Figure 103: Relevant Registers for CPU Error Register Parameter Description CR_IEH (Interrupt & Error Handling) EF_EN_CPU_ERR Bits 15 enables error flags corresponding to register SRR_ERR_FLAG 15: CPU Error
11.7 Assembler
The AS6031 assembler is a multi-pass assembler that translates assembly language files into HEX files as they will be downloaded into the device. For convenience, the assembler can include header
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 98 files. The user can write his own header files but also integrate the library files as they are provided by ScioSense. The assembly program is made of many statements which contain instructions and directives. The instructions have been explained in the former section 3 of this datasheet. In the following sections we describe the directives and some sample code. Each line of the assembly program can contain only one directive or instruction statement. Statements must be contained in exactly one line. Symbols A symbol is a name that represents a value. Symbols are composed of up to 31 characters from the following list: Symbols are not allowed to start with numbers. The assembler is case sensitive, so care has to be taken for this. Numbers Numbers can be specified in hexadecimal or decimal. Decimals have no additional specifier. Hexadecimals are specified by leading “0x”. Expressions and Operators An expression is a combination of symbols, numbers and operators. Expressions are evaluated at assembly time and can be used to calculate values that otherwise would be difficult to be determined. The following operators are available with the given precedence: Figure 104: Assembler Operators Level Operator Description 1 () Brackets, specify order of execution 2 * / Multiplication, Division 3 + — Addition, Subtraction Example: const value 1 equal ((value + 2)/3)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 99 Directives The assembler directives define the way the assembly language instructions are processed. They also provide the possibility to define constants, to reserve memory space and to control the placement of the code. Directives do not produce executable code. The following table provides an overview of the assembler directives. Figure 105: Useful Caption Directive Description Example CONST Constant definition, CONST [name] [value] value might be a number, a constant, a sum of both CONST REV_ADDRESS 3964 CONST FW_VER + 2 LABEL: Label for target address of jump instructions. Labels end with a colon. All rules that apply to symbol names also apply to labels. jsub BLD_CFG; BLD_CFG: move y,16; ; Comment, lines of text that might be implemented to explain the code. It begins with a semicolon character. The semicolon and all subsequent characters in this line will be ignored by the assembler. A comment can appear on a line itself or follow an instruction. ; Call Address: XXX org Sets a new origin in program memory for subsequent statements. org 0 equal Insert three bytes of user defined data in program memory, starting at the address as defined by org. equal 0xcfcf01 #include Include the header or library file named in the quotation marks "". The code will be added at the line of the include command. In quotation marks there might be just the file name in case it is in the same folder as the program, but also the complete path. #include "common.h"
11.7.1 Basic Structure
The following flow chart shows the basic structure of a AS6031 firmware. Figure 106: Basic Program Flow Chart t.b.d.
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 100 The AS6031 has two operation modes with different usage of the memory.
- Time conversion mode: In this mode, the CPU is not active. The device runs as a pure front-end providing the raw time measurement results for flow, temperature and amplitude. The only relevant section of the memory is the random access area (RAA) with the configuration registers, system handling registers, result register and status registers.
- Flow meter mode: In this mode, The CPU is active and does post-processing on the raw data, typically calculating temperature, flow and volume, accompanied by error handling. The program code is stored in NVRAM, in addition to ROM for ready supporting functions. Customers may write their own code or use the applied firmware of AS6031F1. In any case there is a small mandatory applied firmware section. There is a separate section in the NVRAM to store firmware-specific data as well as configuration data. The CPU uses the full 176 × 32 bit RAM to read measurement results, to do its calculations and to write the final results. ROM and firmware code memory share a different address bus system and are not readable from outside the chip. The firmware code memory and the firmware data memory are zero static power NVRAMs. Since they don’t draw current when not in use, they are not switched down and remain permanently usable. However, the address and data bus of the RAA can only be allocated to one system at a time, so access to RAA memory cells from outside is usually not possible when the frontend or the CPU operate on it. The following diagram shows the memory organization and the interaction of the frontend, the CPU and the remote interface.
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 101 Figure 107: Memory Organization
12.1 Program Area
The program area consists of two memory parts: A 4 kB NVRAM for re-programmable program code, and a 4 kB ROM with read-only program code. The firmware code in re-programmable NVRAM memory consists of:
- A USER part which can be programmed by customer
- A divided ScioSense part, pre-programmed by ScioSense including general subroutines addressable by customer. RAM 176 * 32 Bit CPU Core Remote Interface Firmware Code Memory NVRAM 4 kByte ROM Code ROM 4 kByte Program Area FDB Random Access Area Firmware Data NVRAM 128 * 32 Bit not used, 16 * 32 Bit Register Area 64 * 32 Bit Frontend Firmware USER Applied firmware SPI not used, 56 * 32 Bit ACP 8 * 32 Bit FDB, 0x80 to 0x9B
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 102 Figure 108: Program Area The available size of USER Firmware (FWU) is defined in register SRR_FWU_RNG. The user can read this. In addition, the USER firmware has a reserved area of 4 byte at the beginning of the code memory, which can be used to implement a revision number. The revision can be read via register SRR_FWU_REV. The revision of applied firmware (FWA) can be read via SRR_FWA_REV. Note that these two registers get updated by the bootloader, which is run after each POR, system reset or system init. The bootloader updates the SRR_FWU_RNG as well as the revision registers. The firmware code in read-only ROM memory includes system subroutines (bootloader, checksum generation) and general subroutines which are also addressable by users. It further handles an initial check of CPU requests set in SHR_CPU_REQ register
12.2 Random Access Area (RAA)
The random access area can be separated into 4 sections: FWCU User Code FWCA Applied Code FWCU_RNG 0x0000 0x1000 FWC Firmware Code Memory FWCA Applied Code 0x0024
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 103
- Random access memory (RAM) storing volatile firmware data and including frontend data buffer
- Register area
- Non-volatile RAM (NVRAM) storing non-volatile firmware data
- Asynchronous Communication Port The RAA has the following structure: Figure 109: Random Access Area (RAA) IP Address DWORD Section Description Type(1) RAM 176×32 0x000 to 0x07F 128 FWV Firmware variables RW 0x080 to 0x087 8 FDB Frontend Data Buffer RW 0x088 to 0x09B 20 FDB / (FWV) Frontend Data Buffer / Firmware variables RW 0x09C to 0x09F 4 FWV Firmware variables RW 0x0A0 to 0x0AF 16 FWV or (TEMP) Firmware variables or temporary variables RW 0x0B0 to 0x0BF 16 NU Not used Direct Mapped Registers 0x0C0 to 0x0CF 16 CR Configuration Registers RW 0x0D0 to 0x0DF 16 SHR Special Handling Registers RW 0x0E0 to 0x0EF 16 SRR Status & Result Registers RO 0x0F0 to 0x0F7 8 NU Not used 0x0F8 to 0x0FB 4 DR For internal use only RO 0x0FC to 0x0FF 4 NU Not used NVRAM 120×32 0x100 1 FWCU_CS Firmware Code User, Checksum RW 0x101 1 FWDU_CS Firmware Data User, Checksum RW 0x102 to 0x16A 105 FWDU Firmware Data RW 0x16B 1 ACR Autoconfig Release Code RW 0x16C to 0x177 12 CDU Configuration Data User RW NVRAM 8×32 0x178 to 0x17A 3 FWDA_CD CDA Configuration Data ScioSense RW(1) 0x17B to 0x17C 2 PUID Production Unique ID RW(1) 0x17D 1 FWDA_CS Firmware Data SCIOSENSE, Checksum RW(1) 0x17E 1 FWCA_CS Firmware Code SCIOSENSE, Checksum RW(1) 0x17F 1 FWD_CPT For internal use only RW(1) 0x180 to 0x1BF 64 NU Not used Direct Mapped Registers 0x1C0 to 0x1C7 8 ACP Asynchronous communication port GET: CPU → SPI RO/WO(2) 0x1C8 to 0x1FF 56 NU Not used (1) Write Access for Page 2 of NVRAM is disabled for users, and only foreseen for ScioSense production flow. (2) Read only by remote interface, write only by CPU
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 104
12.2.1 Frontend Data Buffer (FDB)
The frontend data buffer is used by the ultrasonic measurement (including time of flight-, amplitude- and pulse-width-measurement). Time-of-flight measurement and the temperature measurement cover the same FBD section alternately. The RAM content of the FDB depends on which measurement has been executed recently. FDB in case of Time-of-Flight Measurement In case of an ultrasonic ToF measurement the FDB contains the results for up to 10 individual zero crossing data in up and down as well as the average over all as being configured. In addition, the pulse width ratio, the amplitude measurement result and the amplitude calibration result are stored. Figure 110: FDB in case of ToF Addr Name(1) Description 0x080 FDB_US_TOF_SUM_OF_ALL_U Ultrasonic TOF Sum of All Value Up 0x081 FDB_US_PW_U Ultrasonic Pulse Width Ratio Up 0x082 FDB_US_AM_U Ultrasonic Amplitude Value Up 0x083 FDB_US_AMC_VH Ultrasonic Amplitude Calibrate Value High 0x084 FDB_US_TOF_SUM_OF_ALL_D Ultrasonic TOF Sum of All Value Down 0x085 FDB_US_PW_D Ultrasonic Pulse Width Ratio Down 0x086 FDB_US_AM_D Ultrasonic Amplitude Value Down 0x087 FDB_US_AMC_VL Ultrasonic Amplitude Calibrate Value Low 0x088 FDB_US_TOF_0_U Ultrasonic TOF Up: Value 0 (1-0) 0x089 FDB_US_TOF_1_U Ultrasonic TOF Up: Value 1 (1-1) 0x08A FDB_US_TOF_2_U Ultrasonic TOF Up: Value 2 (1-2) 0x08B FDB_US_TOF_3_U Ultrasonic TOF Up: Value 3 (2-0) 0x08C FDB_US_TOF_4_U Ultrasonic TOF Up: Value 4 (2-1) 0x08D FDB_US_TOF_5_U Ultrasonic TOF Up: Value 5 (2-2) 0x08E FDB_US_TOF_6_U Ultrasonic TOF Up: Value 6 (3-0) 0x08F FDB_US_TOF_7_U Ultrasonic TOF Up: Value 7 (3-1) 0x090 FDB_US_TOF_8_U Ultrasonic TOF Up: Value 8 (3-2) 0x091 FDB_US_TOF_9_U Ultrasonic TOF Up: Value 0 (3-3) 0x092 FDB_US_TOF_0_D Ultrasonic TOF Down: Value 0 (1-0) 0x093 FDB_US_TOF_1_D Ultrasonic TOF Down: Value 1 (1-1) 0x094 FDB_US_TOF_2_D Ultrasonic TOF Down: Value 2 (1-2) 0x095 FDB_US_TOF_3_D Ultrasonic TOF Down: Value 3 (2-0) 0x096 FDB_US_TOF_4_D Ultrasonic TOF Down: Value 4 (2-1) 0x097 FDB_US_TOF_5_D Ultrasonic TOF Down: Value 5 (2-2) 0x098 FDB_US_TOF_6_D Ultrasonic TOF Down: Value 6 (3-0) 0x099 FDB_US_TOF_7_D Ultrasonic TOF Down: Value 7 (3-1)
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 106 Addr Name(1) Unit(1) Seq.(2) Description FDB_TPM2_M1B_RAB_G12 0x08F FDB_TPM2_RAB_G12 Reference port REF-AB 0x090 FDB_TPM2_M1A_G12 T Temperature port M1-A 0x091 FDB_TPM2_M2A_G12 Temperature port M2-A 0x092 FDB_TPM2_RA_G12 C RDSON compensation 0x093 FDB_TPM2_MI_R_G12 I Internal temperature reference 0x094 FDB_TPM2_MI_RM_G12 Internal temperature compensation 0x095 FDB_TPM2_MI_M_G12 Internal temperature measurement (1) C [grey] = Compensation T [red] = Temperature I [orange] = Internal temperature (2) Seq. = measurement sequence Figure 113: FDB in case of 4-wire Temperature Addr Name(1) Seq. (1) Description 0x080 FDB_T4W1_M1AB_RAB_G12 Gain compensation 0x081 FDB_T4W1_RAB_G12 Reference port REF-AB 0x082 FDB_T4W1_M1AB_G12 Temperature port M1-AB 0x083 FDB_T4W1_M2AB_G12 Temperature port M2-AB 0x084 FDB_T4W1_RA_G12 Reference port REF A 0x085 FDB_T4W1_RB_G12 Reference port REF B 0x086 FDB_T4W1_M1A_G12 Temperature port M1-A 0x087 FDB_T4W1_M1B_G12 Temperature port M1-B 0x088 FDB_T4W1_M1AB_G1 Temperature port M1-AB 0x089 FDB_T4W1_M1AB_G2 Temperature port M1-AB 0x08A FDB_T4W1_M2A_G12 Temperature port M2-A 0x08B FDB_T4W1_M2B_G12 Temperature port M2-B 0x08C FDB_TPM1_M2B_G1 Temperature port M2-AB 0x08D FDB_TPM1_M2B_G2 Temperature port M2-AB 0x08E FDB_T4W2_M1AB_RAB_G12 Gain compensation 0x08F FDB_T4W2_RAB_G12 Reference port REF-AB 0x090 FDB_T4W2_M1AB_G12 Temperature port M1-AB 0x091 FDB_T4W2_M2AB_G12 Temperature port M2-AB 0x092 FDB_T4W2_RA_G12 Reference port REF A 0x093 FDB_T4W2_RB_G12 Reference port REF B 0x094 FDB_T4W2_M1A_G12 Temperature port M1-A 0x095 FDB_T4W2_M1B_G12 Temperature port M1-B 0x096 FDB_T4W2_M1AB_G1 Temperature port M1-AB 0x097 FDB_T4W2_M1AB_G2 Temperature port M1-AB
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 107 Addr Name(1) Seq. (1) Description 0x098 FDB_T4W2_M2A_G12 Temperature port M2-A 0x099 FDB_T4W2_M2B_G12 Temperature port M2-B 0x09A FDB_T4W2_M2AB_G1 Temperature port M2-AB 0x09B FDB_T4W2_M2AB_G2 Temperature port M2-AB (1) Seq. = Measurement sequence
12.2.2 Configuration Registers
The AS6031 has 15 configuration registers of up to 32 bit word length. Configuration registers mainly contain fixed parameters which define the operation of all functional blocks of the UFC. They can be automatically initialized by the bootloader from firmware data in the NVRAM. Figure 114: Configuration Registers Overview Addr Name Description 0x0C0 CR_WD_DIS Watchdog Disable 0x0C1 CR_IFC_CTRL Interfaces Control 0x0C2 CR_GP_CTRL General Purpose Control 0x0C3 CR_USM_OPT USM: Options 0x0C4 CR_IEH Interrupt & Error Handling 0x0C5 CR_CPM Clock & Power Management 0x0C6 CR_MRG_TS Measure Rate Generator & Task Sequencer 0x0C7 CR_TPM Temperature Measurement 0x0C8 CR_USM_PRC USM: Processing 0x0C9 CR_USM_FRC USM: Fire & Receive Control 0x0CA CR_USM_TOF USM: Time of Flight 0x0CB CR_USM_AM USM: Amplitude Measurement 0x0CC CR_TRIM1 Trim Parameter 0x0CD CR_TRIM2 Trim Parameter 0x0CE CR_TRIM3 Trim Parameter 0x0CF NOT USED Not used
12.2.3 Special Handling Registers (SHR)
The AS6031 has 15 special handling registers of up to 32 bit word length. Special handling registers define the operation of the various units of UFC, like the configuration registers. Unlike the configuration registers, they contain data that is supposed to change during operation. Most of these
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 108 registers are not automatically initialized. The bootloader initializes SHR_TOF_RATE with FWD(118)[29:24] and SHR_ZCD_FHL_U/D with FWD(119)[31:24]. Figure 115: Special Handling Registers Overview Addr Name Description 0x0D0 SHR_TOF_RATE Time-of-Flight rate 0x0D1 SHR_USM_RLS_DLY_U Multi-hit Start Delay Up 0x0D2 SHR_USM_RLS_DLY_D Multi-hit Start Delay Down 0x0D3 SHR_GPO General Purpose Out 0x0D4 SHR_PI_NPULSE Pulse Interface Number of Pulses 0x0D5 SHR_PI_TPA Pulse Interface Time Pulse Distance 0x0D6 SHR_PI_IU_TIME Pulse Interface, Internal Update Time Distance 0x0D7 SHR_PI_IU_NO Pulse Interface Number of internal Update 0x0D8 NOT USED not used 0x0D9 SHR_ZCD_LVL Zero cross detection, level 0x0DA SHR_ZCD_FHL_U Zero Cross Detection First Hit Level Up 0x0DB SHR_ZCD_FHL_D Zero Cross Detection First Hit Level Down 0x0DC SHR_CPU_REQ CPU Requests 0x0DD SHR_EXC Executables 0x0DE SHR_RC Remote Control 0x0DF SHR_RC_RLS Release Code for actions of SHR_RC
12.2.4 Status & Result Registers
The AS6031 has 14 status & result registers of up to 32 bit word length. The status & result registers contain information generated by the chip hardware, e.g. status information like error flags or timing information, or measurement values from various hard-coded calibrations. It is not possible to write them directly. Figure 116: Status & Result Registers Overview Addr Name Description 0x0E0 SRR_IRQ_FLAG Interrupt Flags 0x0E1 SRR_ERR_FLAG Error Flags 0x0E2 SRR_FEP_STF Frontend Processing Status Flags 0x0E3 SRR_GPI General Purpose In 0x0E4 SRR_HCC_VAL High-Speed Clock Calibration Value 0x0E5 SRR_VCC_VAL Measurement Value for VCC Voltage 0x0E6 SRR_TSV_HOUR Time Stamp Value: Hours
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 109 Addr Name Description 0x0E7 SRR_TSV_MIN_SEC Time Stamp Value: Minutes & Seconds 0x0E8 NOT USED not used 0x0E9 SRR_TS_TIME Task Sequencer Time 0x0EA SRR_MSC_STF Miscellaneous Status Flags 0x0EB SRR_I2C_RD 2-wire Master Interface Read Data 0x0EC SRR_FWU_RNG Range Firmware Code User 0x0ED SRR_FWU_REV Revision Firmware Code User 0x0EE SRR_FWA_REV Revision Firmware Code ScioSense 0x0EF NOT USED Not used
12.3 Detailed Register Description
12.3.1 Frontend Data Buffer
Data Format of TDC Time Values in Frontend Data Buffer This data format is given for all provided result values in Frontend Data Buffer, except value for pulse width ratio. Figure 117: FDB DATA FORMAT OF TDC DATA Bit Description 31:0 TDC Time Value Unsigned integer, 1 LSB: 1/ 216 * tperiod(HSO) tperiod(HSO) = 250 ns TDC running with 4 MHz tperiod(HSO) = 125 ns TDC running with 8 MHz Notes: 1. The sum of TOF values may not exceed 16 ms @ 4 MHz, 8 ms @ 8 Mhz. Individual TOF values shall not exceed 4 ms @ 4 MHz, 2 ms @ 8 MHz 2. The average of the TOF hits, (FDB_US_TOF_SUM_OF_ALL_x / TOF_HIT_SUM_NO), is shifted by (TOF_HIT_SUM_NO – 1)/2*Tref versus the first hit FDB_US_TOF_0_x Data Format of Pulse Width Ratio This data format is only given for value of pulse width ratio.
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 110 Figure 118: FDB DATA FORMAT OF PULSE WIDTH DATA Bit Description 31:0 Pulse Width Ratio Ratio of pulse width between first hit and start hit Unsigned integer [7:0], 1 LSB: 1/ 27, Range: 0 to 1.992
12.3.2 Configuration Registers
CR_WD_DIS Register (Address 0x0C0) Figure 119: CR_WD_DIS Register Addr: 0x0C0 CR_WD_DIS (Watchdog Disable) Bit Bit Name Bit Description 31:0 WS_DIS Code to disable Watchdog: 0x48DB_A399, Write only register, with default 0xAF0A7435. Status of watchdog can be checked in WD_DIS in register SRR_MSC_STF CR_IFC_CTRL Register (Address 0x0C1) Figure 120: CR_IFC_CTRL Register Addr: 0x0C1 CR_IFC_CTRL (Interfaces Control) Bit Bit Name Bit Description 7:0 PI_TPW Pulse Interface, Pulse Width = PI_TPW * 976.5625 μs (LP_MODE = 1), = PI_TPW * 1 ms (LP_MODE = 0)
8 PI_EN
Pulse Interface Enable, if operating in flow meter mode 0: Pulse Interface disabled 1: Pulse Interface enabled
9 PI_OUT_MODE
0: Output of pulses on 1 line with additional direction signal 1: Output of pulses on different lines for each direction
10 PI_UPD_MODE
0: Automatic Update disabled, only by PI_UPD in SHR_EXC 1: Automatic Update wit next TOF Trigger
11 NOT_USED Mandatory setting: b0
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 111 Addr: 0x0C1 CR_IFC_CTRL (Interfaces Control) Bit Bit Name Bit Description 13:12 I2C_MODE 2-wire master interface mode, I2C like 00: I2C disabled 01: I2C enabled on GPIO 0/1 10: I2C enabled on GPIO 2/3 11: Not allowed 20:14 I2C_ADR 2-wire master interface slave address
21 NOT_USED Mandatory setting: b0
23:22 SPI_INPORT_CFG Configuration of SPI input ports: SSN, MOSI & SCK 00: Inputs High Z (recommended if SPI is connected) 01: Inputs Pull Up (recommended if SPI is disconnected) 10: Inputs Pull Down 11: Inputs High Z 31:24 NOT USED CR_GP_CTRL Register (Address 0x0C2) Figure 121: CR_GP_CTRL Register Addr: 0x0C2 CR_GP_CTRL (General Purpose Control) Bit Bit Name Bit Description 1:0 GP0_DIR Direction of General Purpose Port 0 00: Output 01: Input Pull Up 10: Input Pull Down 11: Input High Z 3:2 GP0_SEL Selection for General Purpose Port 0 Output (GP0_DIR = 00) 00: General Purpose Out[0] 01: Pulse Interface -> Pulse 10: Low Speed Clock 11: Ultrasonic Fire Burst Input (GP2_DIR = 01 / 10 / 11) provided to SRR_GPI[0] 00: Mandatory setting 01 / 1x : Not allowed 5:4 GP1_DIR Direction of General Purpose Port 1 see definition for GP0_DIR
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 112 Addr: 0x0C2 CR_GP_CTRL (General Purpose Control) Bit Bit Name Bit Description 7:6 GP1_SEL Selection for General Purpose Port 1 Output (GP1_DIR = 00) 00: General Purpose Out[1] 01: Pulse Interface -> Direction 10: Error Flag (low active) 11: Ultrasonic Direction Input (GP1_DIR = 01 / 10 / 11) provided to SRR_GPI[1] 00: Mandatory setting 01 / 1x : Not allowed 9:8 GP2_DIR Direction of General Purpose Port 2 see definition for GP0_DIR 11:10 GP2_SEL Select of General Purpose Port 2 Output (GP2_DIR = 00) 00: General Purpose Out[2] 01: Pulse Interface -> Pulse 10: TI_FP_PCH 11: not used Input (GP2_DIR = 01 / 10 / 11) provided to SRR_GPI[2] 00: Mandatory setting 01 / 1x : Not allowed 13:12 GP3_DIR Direction of General Purpose Port 3 00: Output 01: Input Pull Up 10: Input Pull Down 11: Input High Z 15:14 GP3_SEL Selection for General Purpose Port 3 Output (GP3_DIR = 00) 00: General Purpose Out[3] 01: Pulse Interface -> Direction 10: not used 11: Ultrasonic Fire Busy (TI_FIRE_BUSY) Input (GP3_DIR = 01 / 10 / 11) provided to SRR_GPI[3] 00: Mandatory setting 01 / 1x : Not allowed 17:16 GP4_DIR Direction of General Purpose Port 4 00: Output 01: Input Pull Up 10: Input Pull Down 11: Input High Z 19:18 GP4_SEL Selection for General Purpose Port 4 Output (GP4_DIR = 00): 00: General Purpose Out[4] 01: Ultrasonic Measurement Busy 10: PGA Enable (TI_PGA_EN) 11: not used Input (GP4_DIR = 01 / 10 / 11) provided to SRR_GPI[4] 00: Mandatory setting 01 / 1x : Not allowed
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 113 Addr: 0x0C2 CR_GP_CTRL (General Purpose Control) Bit Bit Name Bit Description 21:20 GP5_DIR Direction of General Purpose Port 5. 00: Output 01: Input Pull Up 10: Input Pull Down 11: Input High Z 23:22 GP5_SEL Selection for General Purpose Port 5 Output (GP5_DIR = 00) 00: General Purpose Out[5] 01: not used 10: PGA VREF Enable (TI_PGA_VREF) 11: not used Input (GP5_DIR = 01 / 10 / 11) provided to SRR_GPI[5] 00: Mandatory setting 01 / 1x : Not allowed 31:24 NOT_USED Not used CR_USM_OPT Register (Address 0x0C3) Figure 122: CR_USM_OPT Register Addr: 0x0C3 CR_USM_OPT (Ultrasonic Measurement Options) Bit Bit Name Bit Description 4:0 USM_OPT Mandatory setting b00001 31:5 NOT USED CR_IEH (Interrupt & Error Handling) Figure 123: CR_IEH Register Addr: 0x0C4 CR_IEH (Interfaces Control) Bit Bit Name Bit Description
0 EF_EN_TDC_TMO Error Flag Enable, TDC Timeout
1 EF_EN_TOF_TMO Error Flag Enable, TOF Timeout
2 EF_EN_AM_TMO Error Flag Enable, Amplitude Measurement Timeout
3 EF_EN_TM_OC Error Flag Enable, Temperature Measurement Open
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 114 Addr: 0x0C4 CR_IEH (Interfaces Control) Bit Bit Name Bit Description
4 EF_EN_TM_SC Error Flag Enable, Temperature Measurement Short
5 EF_EN_ZCC_ERR Error Flag Enable, Zero Cross Calibration Error
6 EF_EN_LBD_ERR Error Flag Enable, Low Battery Detect Error
7 EF_EN_USM_SQC_TMO Error Flag Enable, Ultrasonic Sequence Timeout
8 EF_EN_TM_SQC_TMO Error Flag Enable, Temperature Sequence Timeout
9 EF_EN_TSQ_TMO Error Flag Enable, Task Sequencer Timeout
10 EF_EN_I2C_ACK_ERR Error Flag Enable, EEPROM Acknowledge Error
11 NOT USED Mandatory setting: b0
12 EF_EN_NVM_FWCU_ERR Error Flag Enable, NVM FWCU Error
13 EF_EN_NVM_FWDU_ERR Error Flag Enable, NVM FWDU Error
14 EF_EN_NVM_FWA_ERR Error Flag Enable, NVM Applied Firmware Error
15 EF_EN_CPU_ERR Error Flag Enable, CPU Error
16 IRQ_EN_TSQ_FNS Interrupt Request Enable, Task Sequencer finished
17 IRQ_EN_TRANS_FNS Interrupt Request Enable, FW Transaction finished
18 IRQ_EN_BLD_FNS Interrupt Request Enable, Bootload finished
19 IRQ_EN_CHKSUM_FNS Interrupt Request Enable, Checksum generation
20 IRQ_EN_FW_S Interrupt Request Enable , Firmware, synchronized
21 IRQ_EN_TSQ_TO Interrupt Request Enable, Task Sequencer Timeout
22 NOT_USED Mandatory to set: b0
23 IRQ_EN_ERR_FLAG Interrupt Request Enable, Error Flag
26:24 NOT_USED Mandatory setting: b000
27 CPU_REQ_EN_GPH
CPU Request Enable, General Purpose Handling 0: disabled 1: enabled, to be triggered by GP Timer via TS_GPT_RATE, via SHR_EXC or RC_REQ_GPH
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 115 Addr: 0x0C4 CR_IEH (Interfaces Control) Bit Bit Name Bit Description 31:28 TS_GPT_RATE General Purpose Timer Rate 0000: GPT Timer disabled 0001: 1 sec 0010: 2 sec 0011: 5 sec 0100: 10 sec 0101: 30 sec 0110: 1 min 0111: 2 min 1000: 5 min 1001: 10 min 1010: 30 min 1011: 1 h 1100: 2 h 1101: 6 h 1110: 24 h 1111: 48 h If enabled, also CPU_REQ_EN_GPH must be set ! CR_CPM (Clock- & Power-Management) Figure 124: CR_CPM Register Addr: 0x0C5 CR_CPM (Clock- & Power-Management) Bit Bit Name Bit Description
0 HSC_DIV_MODE
High Speed Clock Divider Mode 0: Recommended for HS_CLK = 4 MHz 1: Recommended for HS_CLK = 8 MHz
1 NOT_USED Mandatory to set: b0
4:2 HSC_CLK_ST High-Speed Clock Settling Time 000: On Request, Settling Time 74 µs 001: On Request, Settling Time 104 µs 010: On Request, Settling Time 135 µs 011: On Request, Settling Time 196 µs 100: On Request, Settling Time 257 µs 101: On Request, Settling Time 379 µs 110: On Request, Settling Time 502 µs 111: On Request, Settling Time ~5000 µs 7:5 NOT_USED Recommended setting: b001
8 HSC_DIV
0: Recommended for HS_CLK = 4 MHz 1: HS_CLK divided by 2 for all individual high speed clock dividers. Recommended for HS_CLK = 8 MHz
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 116 Addr: 0x0C5 CR_CPM (Clock- & Power-Management) Bit Bit Name Bit Description 11:9 HSC_RATE High-Speed Clock Calibration Rate, every Nth measure cycle trigger 000: disabled 001: every 010: every 2nd 011: every 5th 100: every 10th 101: every 20th 110: every 50th 111: every 100th
12 HSC_MODE_CPU
0: High Speed Clock for CPU running with 4 MHz 1: High Speed Clock for CPU running with 1 MHz Note: Clock source can be changed in FW code with opcode clkmode, default is internal CPU clock. 15:13 VM_RATE VCC Voltage measurement rate, every Nth measure cycle trigger 000: disabled 001: every 010: every 2nd 011: every 5th 100: every 10th 101: every 20th 110: every 50th 111: every 100th 21:16 LBD_TH Low battery detection threshold, can be used with VCC measurement LBD_TH = 0: 2.15 V LBD_TH = 63: 3.725 V
22 TSV_UPD_MODE
0: updated by TSV_UPD in SHR_EXC 1: automatically updated every measure cycle trigger
23 BF_SEL
0: 50 Hz TBF = 20 ms 1: 60 Hz TBF = 16.66 ms 27:24 NOT_USED Mandatory to set: b0000
28 NOT_USED Set to b0
30:29 TI_PATH_SEL Transducer Fire Buffer Impedance: 00:= buffer disabled 01:= enables 550 Ohm Buffer 10:= enables 350 Ohm buffer 11:= enables 214 Ohm buffer
31 NOT_USED Mandatory to set: b0
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 117 CR_MRG_TS (Measure Rate Generator & Task Sequencer) Figure 125: CR_MRG_TS Register Addr: 0x0C6 CR_MRG_TS (Measure Rate Generator & Task Sequencer) Bit Bit Name Bit Description 12:0 MR_CT Measure rate cycle time 0: disabled 1 to 8191: Cycle time = MR_CT x 976.5625 µs (LP_MODE = 1), = MR_CT x 1 ms (LP_MODE = 0)
13 TS_MCM
Task Sequencer Measure Cycle Mode 0: Cycle Trigger in same phase for USM and TM 1: Cycle Trigger in different phases for USM and TM
14 TS_PP_T_EN
Enables final post processing T (after last measurement task) 0: Post Processing T disabled 1: Post Processing T enabled
15 TS_PP_F_EN
Enables post processing F (after flow and amplitude measurement task) 0: Post Processing F disabled 1: Post Processing F enabled
16 TS_PP_MODE
Post processing mode (only if post processing is enabled) 0: Post processing requested with every task sequencer trigger 1: Post processing only requested if a measurement task is requested 19:17 TS_CST_RATE Firmware Check(sum) Timer Rate 000: disabled 001: 1h 010: 2h 011: 6h 100: 24h 101: 48h 110: 96h 111: 168h 23:20 TS_NVR_RATE Recall Timer Rate 0000: NVR Timer disabled 1011: 1 h 1100: 2 h 1101: 6 h 1110: 24 h 1111: 48 h 25:24 NOT_USED Mandatory to set: b01
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 118 Addr: 0x0C6 CR_MRG_TS (Measure Rate Generator & Task Sequencer) Bit Bit Name Bit Description 30:26 NOT_USED Mandatory to set: b00000
31 TS_CST_MODE
0: performed as soon as timer request occurs (recommended if TS_MCM = 0) 1: only performed if no TPM or USM measurement task is requested in this task sequencer cycle (recommended if TS_MCM = 1) CR_TPM (Temperature Measurement) Figure 126: CR_TPM Register Addr: 0x0C7 CR_TPM (Temperature Measurement) Bit Bit Name Bit Description 9:0 TM_RATE Temperature Measurement Rate 0: disabled 1 to 1023: Rate related to sequencer cycle trigger 12:10 TPM_PAUSE Pause time between 2 temperature measurements 00x: not used 010: Pause = 0.25 * T(BF_SEL) ms 011: Pause = 0.5 * T(BF_SEL) ms 100: Pause = 1.0 * T(BF_SEL) ms 101: Pause = 1.5 * T(BF_SEL) ms 110: Pause = 2.0 * T(BF_SEL) ms 111: Pause = 2.5 * T(BF_SEL) ms 15:13 TM_MODE Temperature Measurement Mode 000: Off 001: Internal only 010: Internal & 2-wire/1 port 011: Internal & 2-wire/2 ports 100: 2-wire/1 port 101: 2-wire/2 ports 110: 4-wire/1 port 111: 4-wire/2 ports
16 NOT USED Mandatory to set: b0
17 TPM_PORT_MODE
Temperature Measurement Port Mode 0: Inactive ports pulled to GND while measurement 1: Inactive ports set to HighZ while measurement (only for extern measurement)
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 119 Addr: 0x0C7 CR_TPM (Temperature Measurement) Bit Bit Name Bit Description 19:18 TM_PORT_ORDER Temperature Measurement Port Order 10: 1st measurement: default order / 2nd measurement: reversed order (recommended) 21:20 TPM_CLOAD_TRIM Temperature Measurement Load Trim Defines a delay between enabling of measure port(s) and starting measurement (switching point of CLOAD between charging & discharging) 10: 3.95 µs ± 1ns (recommended)
22 TPM_CYCLE_SEL
Temperature Measurement Cycle Select 0: 512 µs (recommended) 1: 1024 µs
23 TPM_FAKE_NO
Number of Fake measurements 0: 2 fake measurements (recommended) 1: 8 fake measurements 31:24 NOT USED Not used Mandatory setting: h00 CR_USM_PRC (Ultrasonic Measurement Processing) Figure 127: CR_USM_PRC Register Addr: 0x0C8 CR_USM_PRC (Ultrasonic Measurement Processing) Bit Bit Name Bit Description 2:0 USM_PAUSE Pause time between two ultrasonic measurements 000: no pause, only 1 measurement performed * 001: not allowed 010: 0.25 * T(BF_SEL) ms 011: 0.5 * T(BF_SEL) ms 100: 1.0 * T(BF_SEL) ms 101: 1.5 * T(BF_SEL) ms 110: 2.0 * T(BF_SEL) ms 111: 2.5 * T(BF_SEL) ms If no pause is configured (USM_PAUSE = 0), CR_TRIM2[7:6] has to be configured to b00.
3 NOT_USED Mandatory setting: b0
5:4 USM_DIR_MODE Ultrasonic Measurement Direction Mode 00: Always starting firing via UP-buffer 01: Always starting firing via DOWN-buffer 1x: Toggling direction with every ultrasonic measurement
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 120 Addr: 0x0C8 CR_USM_PRC (Ultrasonic Measurement Processing) Bit Bit Name Bit Description 15:6 USM_NOISE_MASK_WIN Defines the window as long any signal (e.g. noise) is masked on receive path. Starting time refers to rising edge of 1st fire pulse. End time defines switching point between firing and receiving state of transducer interface. Offset: -0.4 µs
1 LSB: 1 µs
17:16 USM_TO Timeout 00: 128 µs 01: 256 µs 10: 1024 µs 11: 4096 µs If HSC_DIV_TDC = 0 for HS_CLK = 4 MHz or it HSC_DIV_TDC = 1 for HS_CLK = 8 MHz. It starts with the sequence of the fire burst. It has to be selected to a value which covers fire burst sequence, time of flight and receive burst sequence.
18 NOT_USED Mandatory to set: b0
19 USM_RLS_MODE
Select mode for multihit start release 0: Start release condition derived by detection of First Hit Level only 1: Start release condition derived by Ultrasonic Release Delay only or in combination by First Hit Level detection 22:20 ZCC_RATE Zero Cross Calibration Rate Triggered by the measurement cycle trigger B 000: disabled 001: every cycle 010: every 2nd cycle 011: every 5th cycle 100: every 10th cycle 101: every 20th cycle 110: every 50th cycle 111: 100th cycle 31:23 NOT_USED Mandatory to set: b000000000
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 121 CR_USM_FRC (Ultrasonic Measurement Fire & Receive Control) Figure 128: CR_USM_FRC Register Addr: 0x0C9 CR_USM_FRC (Ultrasonic Measurement Fire & Receive Control) Bit Bit Name Bit Description 6:0 FBG_CLK_DIV Clock divider for fire burst generator Frequency = High speed clock divided by FPG_CLK_DIV 0, 1: not allowed 2 to 127: divided by 2 to 127
7 FBG_MODE
0: Insertion of low phase 1: Insertion of high phase 15:8 FBG_PHASE_INS Fire Burst Generator, Phase Insertion
1 LSB: 1/(2 * f(FBG_HS_CLK))
0: 2 LSBs 1: 2 LSBs 2 to 255: 2 to 255 LSBs If fFBG_HS_CLK = fHS_CLK then it’s recommended to configure an even value. Otherwise pulse width distortion of HS_CLK will affect inserted phase. 21:16 FBG_BURST_PRE Fire Burst Generator, number of pulses in the initial sequence (pre-burst) 0: Not allowed 1 to 63: 1 to 63 pre pulses 27:22 FBG_BURST_POST Fire Burst Generator, number of pulses in the ending sequence (post-burst) 0: Not allowed 1 to 63: 1 to 63 pre pulses
28 NOT_USED Mandatory to set: b0
29 NOT_USED Mandatory to set: b1
30 TOF_HIT_MODE
TOF data in FDB according to: 0: Multi-hit mode AS6031, 10 TOF data in 3 bundles 1: Multi-hit mode GP30, 10 TOF data in 1 bundle
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 122 CR_USM_TOF (Ultrasonic Measurement Time of Flight) Figure 129: CR_USM_TOF Register Addr: 0x0CA CR_USM_TOF (Ultrasonic Measurement Time of Flight) Bit Bit Name Bit Description
0 NOT USED Mandatory setting: b0
5:1 TOF_HIT_START Defines number of detected hits (including first hit) before hit which is taken as TOF start hit for TDC measurement 0: 0 hits not allowed because start hit cannot be first hit 1: 1 hits (not recommended) 2: 2 hits 31: 31 hits 7:6 TOF_HIT_IGN Number of multi hits ignored between two hits taken for TOF measurement 00: 0 hits 01: 1 hit 10: 2 hits 11: 3 hits 12:8 TOF_HIT_SUM_NO Number of hits taken for sum value of TOF measurement 0: not allowed 1: 1 hit 2: 2 hits ... 31: 31 hits Note: The sum of TOF values may not exceed 16 ms @ 4 MHz, 8 ms @ 8 Mhz. Individual TOF values shall not exceed 4 ms @ 4 MHz, 2 ms @ 8 MHz 19:13 TOF_HIT_END TOF_HIT_MODE =1: not applicable, set to TOF_HIT_END =127 TOF_HIT_MODE =0: Defines hit after start hit which triggers multi-hit end sequence 0: not allowed 1: 1 hit 2: 2 hits ... 127: 127 hits Necessary condition: TOF_HIT_END ≥ TOF_HIT_SUM_NO + 4 21:20 NOT_USED Mandatory to set: b00
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 123 Addr: 0x0CA CR_USM_TOF (Ultrasonic Measurement Time of Flight) Bit Bit Name Bit Description 23:22 TOF_EDGE_MODE Time of Flight, edge mode 00: Time measurement on positive edge of TOF Hit 01: Time measurement on negative edge of TOF Hit 10: Edge for TOF hit toggling after every measurement cycle 11: Edge for TOF hit toggling after every 2. measurement cycle 29:24 TOF_RATE_INIT FWD copy of initial value for TOF rate Only important if autoconfig release code is set. Then, during the boot process, the according FWD cell content is copied into this register (with no further effect) but also into the register SHR_TOF_RATE from which TOF rate is supplied for dynamic operation. 31:30 NOT USED Not used CR_USM_AM (Ultrasonic Amplitude Measurement) Figure 130: CR_USM_AM Register Addr: 0x0CB CR_USM_AM (Ultrasonic Amplitude Measurement) Bit Bit Name Bit Description 2:0 AM_RATE Amplitude measurement rate 000: disabled 001: every TOF trigger 010: every 2nd TOF trigger 011: every 5th TOF trigger 100: every 10ht TOF trigger 101: every 20th TOF trigger 110: every 50th TOF trigger 111: every 100th TOF trigger
3 NOT USED Set to default 0
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 124 Addr: 0x0CB CR_USM_AM (Ultrasonic Amplitude Measurement) Bit Bit Name Bit Description 8:4 AM_PD_END Amplitude measurement, end of peak detection, defined by number of detected hits after hit count has been released 0: not allowed 1: after 1st detected hit 2: after 2nd detected hit 30: after 30th detected hit 31: not allowed Recommended conditions: Amplitude Measurement disabled (AM_RATE = b000) AM_PD_END = 1 Amplitude Measurement enabled (AM_RATE > b000) AM_PD_END ≤ End of TOF measurement 11:9 NOT USED Mandatory setting: b111 14:12 AMC_RATE Amplitude measurement calibration rate 000: disabled 001: with every amplitude measurement 010: every 2nd amplitude measurement 011: every 5th amplitude measurement 100: every 10ht amplitude measurement 101: every 20th amplitude measurement 110: every 50th amplitude measurement 111: every 100th amplitude measurement
15 PWD_EN
Enables pulse width detection 0: pulse width detection disabled 1: pulse width detection enabled 18:16 PGA_TRIM PGA_TRIM sets the DC gain of the PGA via trim bits in steps of
19 NOT_USED Set to default 0
20 PGA_EN_MODE
0: PGA enabled as given by frontend control 1: PGA permanently enabled
21 PGA_MODE
Ultrasonic measurement PGA Mode 0: PGA disabled 1: PGA enabled
22 NOT_USED Mandatory setting: b0
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 125 Addr: 0x0CB CR_USM_AM (Ultrasonic Amplitude Measurement) Bit Bit Name Bit Description
23 AM_PD_START_MODE
0: AM peak detection starts after noise mask window expires 1: AM peak detection starts after ultrasonic release delay expires Suitable only for combined start hit mode, when ultrasonic release delay is configured between end of noise mask window and ultrasonic receive burst 31:24 ZCD_FHL_INIT FWD copy of initial value for first hit levels Only important if autoconfig release code is set. Then, during the boot process, the according FWD cell content is copied into this register (with no further effect) but also into the register SHR_FHL_U & SHR_FHL_D from which first hit levels are supplied for dynamic operation CR_TRIM1 (Trim Parameter 1) Figure 131: CR_TRIM1 Register Addr: 0x0CC CR_TRIM1 (Trim Parameter 1) Bit Bit Name Bit Description 31:0 TRIM1 Default 0x95A0C06C . Has to be 0x94A0C46C CR_TRIM2 (Trim Parameter 2) Figure 132: CR_TRIM2 Register Addr: 0x0CD CR_TRIM2 (Trim Parameter 2) Bit Bit Name Bit Description 31:0 TRIM2 Default 0x40110000 . Has to be 0x401100C4
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 126 CR_TRIM3 (Trim Parameter 3) Figure 133: CR_TRIM3 Register Addr: 0x0CE CR_TRIM3 (Trim Parameter 3) Bit Bit Name Bit Description 31:0 TRIM3 Default 0x4027000F. Has to be 0x00A7400F
12.3.3 Special Handling Registers
SHR_TOF_RATE (Time Of Flight Rate) Figure 134: SHR_TOF_RATE Register Addr: 0x0D0 SHR_TOF_RATE (Time Of Flight Rate) Bit Bit Name Bit Description 5:0 TOF_RATE TOF Rate 0: TOF Measurement disabled 1 to 63: Rate of TOF Measurement relative to measure rate cycle trigger 31:6 NOT USED Not used SHR_USM_RLS_DLY_U (Ultrasonic Release Delay Up) Figure 135: SHR_USM_RLS_DLY_U Register Addr: 0x0D1 SHR_USM_RLS_DLY_U (Ultrasonic Release Delay Up) Bit Bit Name Bit Description 18:0 USM_RLS_DLY_U Delay window in up direction, releasing ultrasonic measurement The start time of the delay window refers to rising edge of the 1st fire pulse 1 LSB: 7.8125 ns 31:19 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 127 SHR_USM_RLS_DLY_D (Ultrasonic Release Delay Down) Figure 136: SHR_USM_RLS_DLY_D Register Addr: 0x0D2 SHR_USM_RLS_DLY_D (Ultrasonic Release Delay Down) Bit Bit Name Bit Description 18:0 USM_RLS_DLY_D Delay window in down direction, releasing ultrasonic measurement. The start time of the delay window refers to rising edge of the 1st fire pulse 1 LSB: 7.8125 ns 31:19 NOT USED Not used SHR_GPO (General Purpose Out) Figure 137: SHR_GPO Register Addr: 0x0D3 SHR_GPO (General Purpose Out) Bit Bit Name Bit Description 5:0 GPO General Purpose Out 7:6 NOT_USED Not used
8 PI_OUT_FRC0 Forces LOW on pulse output (unless PI_OUT_FRC1 is set)
Typically set by firmware for zero flow
9 PI_OUT_FRC1 Forces HIGH on pulse output (priority over PI_OUT_FRC0)
Typically set by firmware for error indication
10 PI_DIR_FRC0 Forces Low on pulse direction (unless PI_DIR_FRC1 is set)
11 PI_DIR_FRC1 Forces HIGH on pulse direction (priority over PI_DIR_FRC0)
12 FWCU_CS_ERR
Set by NVRAM check subroutine in ROM code Triggers EF_NVM_FWCU_ERR
13 FWDU_CS_ERR
Set by NVRAM check subroutine in ROM code Triggers EF_NVM_FWDU_ERR 18:14 FWA_CS_ERR Different FWA checksum errors Set by NVRAM check subroutine in ROM code Triggers EF_NVM_FWA_ERR
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 128 Addr: 0x0D3 SHR_GPO (General Purpose Out) Bit Bit Name Bit Description
19 FW_ERR
Triggers EF_FWA_ERR 31:20 NOT USED Not used SHR_PI_NPULSE (Pulse Interface Number of Pulses) Figure 138: SHR_PI_NPULSE Register Addr: 0x0D4 SHR_PI_NPULSE (Pulse Interface Number of Pulses) Bit Bit Name Bit Description 31:0 PI_NPULSE Number of pulses, signed integer
1 LSB: 1/224
SHR_PI_TPA (Pulse Interface Time Pulse Distance) Figure 139: SHR_PI_TPA Register Addr: 0x0D5 SHR_PI_TPA (Pulse Interface Time Pulse Distance) Bit Bit Name Bit Description 15:0 PI_TPA Minimal distance between two pulses 1 LSB: 0.97656 ms (LP_MODE = 1)
1 LSB: 1 ms (LP_MODE = 0)
Mandatory condition: PI_TPA > PI_TPW 31:16 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 129 SHR_PI_IU_TIME (Pulse Interface Internal Update Time) Figure 140: SHR_ PI_IU_TIME Register Addr: 0x0D6 SHR_PI_IU_TIME (Pulse Interface Internal Update Time) Bit Bit Name Bit Description 15:0 PI_IU_TIME Time between two internal updates 1 LSB: 0.97656 ms (LP_MODE = 1) Mandatory condition: PI_IU_TIME > 2 and PI_IU_TIME > PI_TPW 31:16 NOT USED Not used SHR_PI_IU_NO (Pulse Interface Number of Auto Updates) Figure 141: SHR_ PI_IU_NO Register Addr: 0x0D7 SHR_PI_IU_NO (Pulse Interface Number of Auto Updates) Bit Bit Name Bit Description 7:0 PI_IU_NO Number of internal updates between two general updates Recommended condition for uniformed pulse generation: (PI_IU_NO + 1) * PI_IU_TIME = TOF_RATE * MR_CT 31:8 NOT USED Not used SHR_ZCD_LVL (Zero Cross Detection Level) Figure 142: SHR_ZCD_LVL Register Addr: 0x0D9 SHR_ZCD_LVL (Zero Cross Detection Level) Bit Bit Name Bit Description 9:0 ZCD_LVL Zero Cross Detection Level 1 LSB: ~ 0.88 mV 31:10 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 130 SHR_FHL_U (Zero Cross Detection Level) Figure 143: SHR_FHL_U Register Addr: 0x0DA SHR_FHL_U (Zero Cross Detection Level) Bit Bit Name Bit Description 7:0 ZCD_FHL_U First Hit Level Up 1 LSB ~ 0.88 mV, maximum 200 mV 31:8 NOT USED Not used SHR_FHL_D (First Hit Level Down) Figure 144: SHR_FHL_D Register Addr: 0x0DB SHR_ FHL_D (First Hit Level Down) Bit Bit Name Bit Description 7:0 ZCD_FHL_D First Hit Level Down 1 LSB ~ 0.88 mV, maximum 200 mV 31:8 NOT USED Not used SHR_CPU_REQ (CPU Requests) It is strongly recommended to write to this register via SPI interface only for debug purpose. In this case, Bit 17 of CR_TRIM3 has to be configured to 0. Figure 145: SHR_CPU_REQ Register Addr: 0x0DC SHR_CPU_REQ (CPU Requests) Bit Bit Name Bit Description
0 CPU_REQ_BLD_EXC(1)
CPU Request Bootloader Execute 0: Bootloader subroutine in CPU not requested 1: Bootloader subroutine in CPU requested Triggered by task sequencer, automatically cleared when CPU stops
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 131 Addr: 0x0DC SHR_CPU_REQ (CPU Requests) Bit Bit Name Bit Description
1 CPU_REQ_CHKSUM(1)
CPU Request Build Checksum 0: Build checksum in CPU not requested 1: Configuration compare in CPU requested Triggered by task sequencer, automatically cleared when CPU stops
2 CPU_REQ_PP_T(1)
CPU Request Post Processing PB 0: Post processing PB in CPU not requested 1: Post processing PB in CPU requested Triggered by task sequencer, automatically cleared when CPU stops
3 CPU_REQ_PP_F(1)
CPU Request Post Processing PA 0: Post processing PA in CPU not requested 1: Post processing PA in CPU requested Triggered by task sequencer, automatically cleared when CPU stops
4 CPU_REQ_GPH(1)
CPU Request General Purpose Handling 0: General purpose handling in CPU not requested 1: General purpose handling in CPU requested Triggered by task sequencer, automatically cleared when CPU stops
5 CPU_REQ_FW_INIT(1)
CPU Request Firmware Initialization 0: Firmware initialization not requested 1: Firmware initialization requested Triggered by bootloader sequence in ROM code, automatically cleared when CPU stops
6 NOT USED Not used
7 NOT USED Not used
8 CPU_SFLAG_HSO_ST_TO
0: High speed oscillator not settled yet (not in timeout condition) 1: High speed oscillator settled and stable (in timeout condition) Cleared by HSO_CLR in SHR_EXC Updated and valid only while CPU is running (synchronized by CPU clock)
9 CPU_COM_REQ
0: No communication request (RC_COM_REQ) set by SPI interface 1: Communication request (RC_COM_REQ) set by SPI interface Updated and valid only while CPU is running (synchronized by CPU clock)
10 CPU_LS_CORE_CLK
0: Low phase of LS_CORE_CLK 1: High phase of LS_CORE_CLK Updated and valid only while CPU is running (synchronized by CPU clock) 31:11 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 132 (1) BIT-T= Bits have to be cleared by the system program code or the user program code. SHR_EXC (Executables) Figure 146: SHR_EXC Register Addr: 0x0DD SHR_EXC (Executables) Bit Bit Name Bit Description
0 IF_CLR(1)
0: No action 1: Clears flag SRR_IRQ_FLAG
1 EF_CLR(1)
0: No action 1: Clears flag SRR_ERR_FLAG
2 FES_CLR(1)
0: No action 1: Clears flag SRR_FEP_STF
3 TSC_CLR(1)
0: No action 1: Clears time stamp counter
4 TSV_UPD(1)
0: No action 1: Update time stamp value
5 PI_UPD(1)
0: No action 1: Updates pulse interface
6 BG_REFRESH(1)
0: No action 1: Bandgap refresh
7 MCT_CLR(1)
0: No action 1: Clears measure cycle timer
8 RATE_CTR_CLR(1)
0: No action 1: Clears all rate counters
9 ZCC_RNG_CLR(1)
Zero Cross Calibration Range Clear 0: No action 1: Clears zero cross calibration range
10 FW_IRQ_S(1)
FW Interrupt Request, synchronized with task sequencer 0: No action 1: Interrupt request triggered by FW and synchronized with task sequencer
11 NOT_USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 133 Addr: 0x0DD SHR_EXC (Executables) Bit Bit Name Bit Description
12 COM_REQ_CLR(1)
Communication Request Clear 0: No action 1: Clears communication request via remote interface
13 GPR_REQ_CLR(1)
General Purpose Request Clear 0: No action 1: Clears general purpose request via remote interface
14 GPH_TRIG(1)
General Purpose Handling Trigger 0: No action 1: Triggers general purpose handling for CPU via task sequencer
15 I2C_CLR(1)
0: No action 1: Clears I2C interface controller
16 ACP_PAGE_TGL(1) Toggles ACP page (asynchronous communication)
17 HSO_REQ(1) Requests high speed oscillator
18 HSO_CLR(1) Clears high speed oscillator
31:19 NOT USED Not used (1) SCB= Self-clearing bit SHR_RC (Remote Control) The remote control register is implemented with radio buttons and self-clearing bits. It is used when operating in time conversion mode accessed by remote control. Radio buttons have the advantage in that single states of the register settings can be changed without knowing the complete state of the register. This saves a pre-reading of the register when operating in remote mode. To change a dedicated bit, write a 1 to this one and a 0 to all others. Figure 147: SHR_RC Register Addr: 0x0DE SHR_RC (Remote Control) Bit Bit Name Bit Description 1:0 CFG_OK(1) UFC Configuration OK. Set by bootloader 00: No change of CFG_OK state (WO(3)) 01: Not properly configured 10: Properly configured 11: No change of CFG_OK state (WO)
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 134 Addr: 0x0DE SHR_RC (Remote Control) Bit Bit Name Bit Description 3:2 HSC_DIV_STATE State of HSC_DIV in CR_CPM[8] (Read Only) 01: HSC_DIV = 0 10: HSC_DIV = 1 00, 11: not possible 5:4 RC_FLAG2(1) User Definable Flag, can also be set by firmware. 00: No Change of RC_FLAG2 state (WO) 01: RC_FLAG2 not set 10: RC_FLAG2 set 11: No Change of RC_FLAG2 state (WO) This flag is used if flow firmware is applied. Please refer for appropriate firmware manual for detailed description. 7:6 NOT_USED Mandatory to set: b01 9:8 HSO_MODE(1) High Speed Oscillator Mode 00: No change of HSO_MODE state (WO) 01: HSO controlled as configured 10: HSO always on 11: No change of HSO_MODE state (WO) 11:10 BG_MODE(1) Bandgap Mode 00: No change of BG_MODE state (WO) 01: Bandgap controlled as configured 10: Bandgap always on 11: No Change of BG_MODE state (WO) 13:12 RC_FLAG3(1) User Definable Flag, can also be set by firmware. 00: No Change of RC_FLAG3 state (WO) 01: RC_FLAG2 not set 10: RC_FLAG2 set 11: No Change of RC_FLAG3 state (WO)
14 SYS_RST(2)
0: No action 1: Performs a system reset Execution needs to be enabled by RC_RLS_2
15 SYS_INIT(2)
0: No action 1: Performs a system init Execution needs to be enabled by RC_RLS_2
16 FW_STORE_ALL(2)
Stores Firmware Code & Firmware Data 0: No action 1: Requests storing of complete firmware code & data Execution needs to be enabled by RC_RLS_1
17 FW_STORE_LOCK(2)
Stores & Lock Firmware Program Code & Firmware Data 0: No action 1: Requests storing & locking of user firmware program code & data Execution needs to be enabled by RC_RLS_1
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 135 Addr: 0x0DE SHR_RC (Remote Control) Bit Bit Name Bit Description
18 FW_ERASE(2)
Erases User Firmware Program Code & Firmware Data 0: No action : Requests erasing user firmware program code & data Execution needs to be enabled by RC_RLS_1
19 FWC_RECALL(2)
Recalls Firmware Program Code 0: No action 1: Requests recalling of firmware program code from Flash to SRAM Execution needs to be enabled by RC_RLS_1
20 FWD_RECALL(2)
0: No action 1: Requests recalling of firmware data from Flash to SRAM Execution needs to be enabled by RC_RLS_1
21 FWC_STORE(2)
Stores Firmware Program Code 0: No action 1: Requests storing of firmware program code from SRAM to Flash Execution needs to be enabled by RC_RLS_1
22 FWD_STORE(2)
Stores Firmware Data (FWDU, user part only) 0: No action 1: Requests storing of user firmware data from SRAM to Flash Execution needs to be enabled by RC_RLS_1 31:23 NOT USED Not used (1) RB = Radio button (2) SCB = Self-clearing bit (3) WO = Write only, RO = Read only
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 136 SHR_RC_RLS (Remote Control Release) Figure 148: SHR_RC_RLS Register Addr: 0x0DF SHR_RC_RLS (Remote Control Release) Bit Bit Name Bit Description 31:0 RC_RLS Release codes for dedicated self-clearing bits in SHR_RC: RC_RLS_1 = h50F5_B8CA: Releases bits [22:16] in SHR_RC RC_RLS_2 = hAF0A_4735: Releases bits [15:14] in SHR_RC Status of RC_RLS_1/2 can be checked in RC_RLS_1/2 in SRR_MSC_STF Automatically cleared after one transaction via bits [22:14]. Release code must be re-written for each transaction again.
12.3.4 Status & Result Registers
The status registers contain all the flags indicating interrupt sources, error sources, updated data, GPIOs. In addition, they contain the measurement results for the high-speed clock calibration and for voltage measurement. The time stamp in hours, minutes and seconds is found there as well as I2C read data and firmware revision numbers. SRR_IRQ_FLAG (Interrupt Flags) Figure 149: SRR_IRQ_FLAG Register Addr: 0x0E0 SRR_IRQ_FLAG (Interrupt Flags) Bit Bit Name Bit Description
0 TSQ_FNS Task sequencer finished
1 FW_TRANS_FNS Firmware transaction finished
2 BLD_FNS Bootloader finished
3 CHKSUM_FNS Checksum subroutine finished
4 FW_IRQ_S Firmware interrupt request, synchronized with task
5 TSQ_TMO Task sequencer timeout
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 137 Addr: 0x0E0 SRR_IRQ_FLAG (Interrupt Flags) Bit Bit Name Bit Description
6 NOT_USED Not used
7 ERR_FLAG At least 1 error flag is set
31:8 NOT USED Not used SRR_ERR_FLAG (Error Flags) Figure 150: SRR_ERR_FLAG Register Addr: 0x0E1 SRR_ERR_FLAG (Error Flags) Bit Bit Name Bit Description
0 EF_TDC_TMO Error flag TDC timeout
1 EF_TOF_TMO Error flag TOF timeout
2 EF_AM_TMO Error flag amplitude measurement timeout
3 EF_TM_OC_ERR Error flag temperature measurement open circuit
4 EF_TM_SC_ERR Error flag temperature measurement short circuit
5 EF_ZCC_ERR Error flag zero cross calibration
6 EF_LBD_ERR Error flag low battery detect
7 EF_USM_SQC_TMO Error flag ultrasonic sequence timeout
8 EF_TM_SQC_TMO Error flag temperature sequence timeout
9 EF_TSQ_TMO Error flag task sequencer timeout
10 EF_I2C_ACK_ERR Error flag EEPROM acknowledge
11 NOT USED
12 EF_NVM_FWCU_ERR Error flag NVM error in FWCU area
13 EF_NVM_FWDU_ERR Error flag NVM error in FWDU area
14 EF_NVM_FWA_ERR Error flag NVM error in any FWA area or set by FW
(any bit set of SHR_GPO[19:14])
15 EF_CPU_ERR CPU error (invalid program counter or PC stack overflow)
16 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 138 SRR_FEP_STF (Frontend Processing Status Flags) Figure 151: SRR_FEP_STF Register Addr: 0x0E2 SRR_FEP_STF (Frontend Processing Status Flags) Bit Bit Name Bit Description
0 HCC_UPD
High-Speed Clock Calibration Update 0: No update in SRR_HCC_VAL 1: Updated value in SRR_HCC_VAL
1 TM_UPD
Temperature Measurement Update 0: No update in frontend buffer 1: Updated value in temperature measurement related frontend buffer
2 NOT USED Not used
3 TPM_ST
0: Temperature measurement with 1 subtask 1: Temperature measurement with 2 subtasks
4 US_U_UPD
Ultrasonic Update in Up direction 0: No update in frontend buffer 1: Updated value in ultrasonic up area of frontend buffer
5 US_D_UPD
Ultrasonic Update in Down direction 0: No update in frontend buffer 1: Updated value in ultrasonic down area of frontend buffer
6 US_TOF_UPD
Ultrasonic Update for TOF measurement 0: No update in frontend buffer 1: Updated value in TOF area of frontend buffer
7 US_TOF_EDGE
0: Positive edge 1: Negative edge
8 US_AM_UPD
Update for Amplitude measurement 0: No update in frontend buffer 1: Updated value in AM area of frontend buffer
9 US_AMC_UPD
Update for Amplitude Calibration Measurement 0: No update in frontend buffer 1: Updated value in AMC area of frontend buffer 31:10 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 139 SRR_GPI (General Purpose In) Figure 152: SRR_GPI Register Addr: 0x0E3 SRR_GPI (General Purpose In) Bit Bit Name Bit Description 5:0 GPI General Purpose Input, default 0x3F 7:6 NOT_USED Not used
8 LP_MODE Low Power Mode, default 1
31:8 NOT USED Not used SRR_HCC_VAL (High-Speed Clock Calibration Value) Figure 153: SRR_ Register Addr: 0x0E4 SRR_HCC_VAL (High-Speed Clock Calibration Value) Bit Bit Name Bit Description 25:0 HCC_VAL Clock calibration value, used for the correction factor. Eight times the real reference frequency at the TDC: 8 x fHSO /Hz 31:26 NOT USED Not used SRR_VCC_VAL (VCC Value) Figure 154: SRR_VCC_VAL Register Addr: 0x0E5 SRR_VCC_VAL (VCC Value) Bit Bit Name Bit Description 5:0 VCC_VAL Measured value of VCC voltage VCC_VAL = 0: 2.15 V VCC_VAL = 63: 3.725 V 31:6 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 140 SRR_TS_HOUR (Time Stamp Hours) Figure 155: SRR_TS_HOUR Register Addr: 0x0E6 SRR_TS_HOUR (Time Stamp Hours) Bit Bit Name Bit Description 17:0 TS_HOUR Timestamp Hours
1 LSB: 1h
31:18 NOT USED Not used SRR_TS_MIN_SEC (Time Stamp Minutes & Seconds) Figure 156: SRR_TS_MIN_SEC Register Addr: 0x0E7 SRR_TS_MIN_SEC (Time Stamp Minutes & Seconds) Bit Bit Name Bit Description 7:0 TS_SEC Timestamp Minutes
1 LSB: 1min Range (0 to 59)
15:8 TS_MIN TS_SEC: Timestamp Seconds
1 LSB: 1sec Range (0 to 59)
31:16 NOT USED Not used SRR_TS_TIME (Task Sequencer time) Figure 157: SRR_TS_TIME Register Addr: 0x0E9 SRR_TS_TIME (Task Sequencer time) Bit Bit Name Bit Description 11:0 TS_TIME Consumed time within a task sequencer cycle Current time = TS_TIME * 1953,125 µs (LP_MODE = 1), = TS_TIME* 2 ms (LP_MODE = 0) 31:12 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 141 SRR_MSC_STF (Miscellaneous Status Flags) Figure 158: SRR_MSC_STF Register Addr: 0x0EA SRR_MSC_STF (Miscellaneous Status Flags) Bit Bit Name Bit Description
0 RC_RLS_1 Release 1 of remote communication self-clearing bits
1 STUP_TO Start-up timeout
2 FW_UNLOCKED FW unlocked
3 SI_BUSY Serial remote interface busy
4 COM_REQ Communication request by remote interface
5 GPR_REQ General purpose request by remote interface
6 GPT_REQ General purpose request by GP timer
7 GPH_REQ General purpose request by GPH_TRIG in SHR_EXC
8 MCT_RLS Measure cycle timer release
9 NVM_RDY NVRAM ready
10 NVR_REQ Request by NVRAM recall timer
11 NOT USED Not used
12 HSO_ST_TO High speed oscillator settling timeout
13 I2C_ACK 2-wire interface acknowledge
14 I2C_BSY 2-wire interface busy
15 WD_DIS Watchdog disabled
16 RC_RLS_2 Release 2 of remote communication self-clearing bits
31:17 NOT USED Not used SRR_I2C_RD (I2C Read Data) Figure 159: SRR_RD Register Addr: 0x0EB SRR_I2C_RD (I2C Read Data) Bit Bit Name Bit Description 7:0 I2C_DATA 2-wire interface read data Read data from external device connected via 2-wire interface 31:8 NOT USED Not used
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 142 SRR_FWU_RNG (FW User Range) Figure 160: SRR_FWU_RNG Register Addr: 0x0EC SRR_FWU_RNG (FW User Range) Bit Bit Name Bit Description 11:0 FWU_RNG FW User Range Defines end address FW user code. End address = FWU_RNG - 1 31:12 NOT USED Not used SRR_FWU_REV (FW User Revision) Figure 161: SRR_FWU_REV Register Addr: 0x0ED SRR_FWU_REV (FW User Revision) Bit Bit Name Bit Description 31:0 FWU_REV FW User Revision First 4 bytes in FW user code range, reserved for revision. SRR_FWA_REV (FW SCIOSENSE Revision) Figure 162: SRR_FWA_REV Register Addr: 0x0EE SRR_FWA_REV (FW SCIOSENSE Revision) Bit Bit Name Bit Description 31:0 FWA_REV FW ScioSense Revision
12.3.5 Asynchronous Communication Port
The asynchronous communication port consists of two register banks to write 8 customer specific words. A register bank is only accessible by the FW in CPU. With ACP_PAGE_TGL in SHR_EXC it is possible to toggle between the two register banks. They are located in the RAA from 0x1C0 to 0x1C7. Over the remote interface the register content can be read. It is mandatory to read 0x1C0 first, it will
Memory and Register Description Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 143 trigger that the register content after toggling in CPU FW will be latched and readable by remote interface. Note: Any communication during a measurement can have a negative impact on the measurement quality. Therefore, it is recommended to use a filter in the postprocessing of the ToF measurements, i.e. outlier filter, median filter etc. Figure 163: Asynchronous Port Communication with CPU FW Step Description
1 Write up to 8 words with measurement results to address 0x1C0…0x1C7 in CPU
2 Setting ACP_PAGE_TGL, bit16 in SHR_EXC to 0x1 toggles between the two
3 The data is then available at the remote interface by accessing 0x1C0 first
Application Information
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 144
13.1 Schematic
Figure 164: AS6031 Schematic AS6031 VCC LP_MODE US_UP GND US_DOWN US_UP_M US_UP_P US_DOWN_P US_DOWM_M INVERT_IN NC NC VCC XOUT_4MHZ XIN_4MHZ VDD18_IN SSN MOSI GPIO4 TEST_MODE_PS SCK MISO INTN GPIO3 PGA_OUT GPIO5 US_VREF RECEIVE_SIG COMP_IN VCC GPIO0 GPIO2 TEST_RST XIN_32KHZ XOUT_32KHZ VDD18_OUT VDD18_IN NC NC TPI_PND2 TPI_GND1 TPI_M2_A TPI_M2_B TPI_CLOAD TPI_M1_A TPI_M1_B TPI_REF GPIO1 100n Ceramic resonator f = 4 MHz/8MHz R = 560 kΩ C = 10 pF Quartz f = 32.768 kHz R = 10 MΩ C = 10 pF Rhot Rcold Rref Cload100n 1k0 100n VCC VDD18_OUT VDD18 VCC VDD18 VDD18_OUT 22p 100µ 4R7 100n 1M0 680n to 820n
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 145
13.2 External Components
Figure 165: AS6031 Demo Board BOM Item Quantity Designator Value Part description 2 3 C1, C10, C11 10p CHIP-CAPACITOR 0603 3 1 C18 22p CHIP-CAPACITOR 0603 4 4 C3, C4, C5, C28 100n CHIP-CAPACITOR 0603 5 1 C6 680n CHIP-CAPACITOR 0603 6 2 C50, C51 100n CHIP-CAPACITOR 0805 7 2 C12, C32 100u CHIP-CAPACITOR 0805 8 1 C29 100n C0G CHIP-CAPACITOR 1206 9 3 R1, R2, R3 4R7 CHIP-RESISTOR 0603 10 1 R16 1k CHIP-RESISTOR 0603 11 1 R10 560k CHIP-RESISTOR 0603 12 1R19 1M CHIP-RESISTOR 0603 13 1 R8 10M CHIP-RESISTOR 0603 14 1 U1 AS6031 15 1 U2 3,0V XC6206 Torex 16 1 X1 4MHz Ceramic resonator CSTCR4M00G53-R0 Murata 17 1 X2 32,768kHz Quartz crystal KX-327XS Geyer 18 1 J1 Male Connector 7x1x180° 2,54 19 1 J2 Male Connector 2x1x180° 2,54 20 1 J3 Male Connector 2x1x90° 2,54
Package Drawings & Markings Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 146 Figure 166: Ref. Min Nom Max A 0.80 0.90 1.00 A1 0 0.02 0.05 A2 - 0.65 1.00 A3 0.20 REF L 0.35 0.40 0.45 Θ 0° 14° b 0.18 0.25 0.30 D 7.00 BSC E 7.00 BSC e 0.50 BSC D2 4.20 4.30 4.40 E2 4.20 4.30 4.40 D1 6.75 BSC E1 6.75 BSC aaa 0.15 bbb 0.10 ccc 0.10 ddd 0.05 eee 0.08 fff 0.10 N 48 RoHS Green
Package Drawings & Markings Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 147 (1) All dimensions are in millimeters. Angles in degrees. (2) Dimensioning and tolerancing conform to ASME Y14.5M-1994. (3) N is the total number of terminals. (4) This package contains no lead (Pb). (5) This drawing is subject to change without notice. Figure 167: AS6031 -BQF YYWWXZZ YY Manufacturing Year WW Manufacturing Week X Assembly Plant Identifier ZZ Assembly Traceability Code @ Sublot Identifier xxxxxxxx Tracecode
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 148
15 Appendix
15.1 Notational Conventions
Throughout the AS6031 documentation, the following stile formats are used to support efficient reading and understanding of the documents:
- Hexadecimal numbers are denoted by a leading 0x, e.g. 0xAF = 175 as decimal number. Decimal numbers are given as usual.
- Binary numbers are denoted by a leading 0b, e.g. 0b1101 = 13. The length of a binary number can be given in bit (b) or Byte (B), and the four bytes of a 32b word are denoted B0, B1, B2 and B3 where B0 is the lowest and B3 the highest byte.
- Abbreviations and expressions which have a special or uncommon meaning within the context of AS6031 application is listed and shortly explained in the list of abbreviations, see following page. They are written in plain text. Whenever the meaning of an abbreviation or expression is unclear, please refer to the glossary at the end of this document.
- Variable names for hard coded registers and flags are in bold. Meaning and location of these variables is explained in the datasheet (see registers CR, SRR and SHR).
- Variable names which represent memory or code addresses are in grey. Many of these addresses have a fixed value inside the ROM code, others may be freely defined by software. Their meaning is explained in the firmware and ROM code description, and their physical addresses can be found in the header files. These variable names are defined by the header files and thus known to the assembler as soon as the header files are included in the assembler source code. Note that different variable names may have the same address, especially temporary variables.
- Physical variables are in italics (real times, lengths, flows or temperatures).
15.2 Abbreviations
Figure 168: Abbreviations Short Description AM Amplitude measurement CD Configuration Data CPU Central Processing Unit CR Configuration Register DIFTOF, DIFTOF_ALL Difference of up and down → TOF FEP Frontend Processing
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 149 Short Description FDB Frontend data buffer FHL First hit level (physical value VFHL) FW Firmware, embedded software stored on the chip FWC Firmware Code FWD Firmware Data FWD-RAM Firmware Data, volatile memory part GPIO General purpose input/output Hit Stands for a detected wave period HSO High speed oscillator INIT Initialization process of → CPU or → FEP IO Input/output I2C Inter-Integrated Circuit bus LSO Low speed oscillator MRG Measurement Rate Generator NVRAM, NVM Programmable Non-Volatile Memory PI Pulse interface PP Post Processing PWR Pulse width ratio R RAM address pointer of the CPU, can also stand for the addressed register RAA Random Access Area RAM Random Access Memory RI Remote Interface ROM Read Only Memory ROM code Hard coded routines in ROM SHR Special Handling Register SPI Serial Peripheral Interface SRAM Static RAM SRR Status & Result Register SUMTOF Sum of up and down TOF Task Process, job TDC Time-to-digital-converter TOF, TOF_ALL Time of Flight TS Task Sequencer TM Temperature measurement
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 150 Short Description USM Ultrasonic measurement Vref Reference voltage X,Y,Z Internal registers of the CPU ZCD Zero cross detection, physical level VZCD
15.3 Glossary
Figure 169: Glossary Term Meaning AS6031 Interpretation ACP Asynchronous communication port Register to hold date for asynchronous communication with an external microcontroller. Content needs to be filled by firmware. AM Amplitude measurement This is a peak measurement of the received signal amplitude, which allows to pick the overall signal maximum (to control the signal level). Backup Permanent storage of a data copy AS6031 is prepared for an external data backup, foreseen over the built-in I2C-bus, which permits write and read with an external EEPROM. In principle, a user may also utilize the → GPIOs for his own interface implementation for external backup. Bootloader System routine that initializes CPU operation Typically, after a system reset, first time when the →TS calls the → CPU, the bootloader routine is called. If the → firmware is released, the bootloader loads the chip configuration from FWD into CR and does other hardware initializations like reading firmware revision numbers and calculation of checksums. Burst Analog signal containing a number of → wave periods For a flow measurement, a → fire burst, that means a fixed number of → wave periods of the measurement frequency, is send over a →transducer into the flow medium. After some travel time (see →TOF), a receive burst appears at the opposed transducer, which is detected as a number of →hits. Note that the peak amplitude of the receive burst must not exceed → Vref to avoid negative voltages. Calibration Parameter adjustment to compensate variations In AS6031, different calibration processes are implemented and needed for high quality measurements: → Firmware calibrations: Flow and temperature calibration, but also the → FHL adjustment are under full control of the firmware. Half-automated calibrations: → AM calibration and → HSO calibration are based on dedicated measurements, initiated by the → TS on demand. The actual calibrations need further evaluation by the firmware. Fully hard-coded calibrations: these calibrations need no interaction from firmware. One example is → ZCD level calibration, which only needs to be initiated by the → TS frequently. Another example is → TDC calibration which happens automatically before each measurement. CD Configuration Data 16 x (up to) 32b words of → flash memory for configuration of the chip, address range 0x16C - 0x17A (→ NVRAM). Is copied to → CR for actual usage. Comparator Device that compares two input signals See → ZCD-comparator
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 151 Term Meaning AS6031 Interpretation CPU Central Processing Unit 32b processor (Harvard architecture type) for general data processing. The CPU has a fixed instruction set and acts directly on its three input- and result-registers → X,Y and Z as well as on addressed RAM. The fourth register of the CPU is the → RAM address pointer R. Instructions for the CPU are read as → FWC or → ROM code at an address given by the → program counter. CR Configuration Register The chip actually uses for its hardware configuration a copy of the → CD into the CR address range 0x0C0 - 0x0CF (see → direct mapped registers). C0G Material of a ceramic capacitor with a very low temperature drift of capacity DIFTOF, DIFTOF_ALL Difference of up and down → TOF The difference between up and down → TOF is the actual measure for flow speed. (see also → SUMTOF). DIFTOF_ALL is the DIFTOF using → TOF_ALL results, averaged over all TOF → hits Direct mapped registers Registers with direct hardware access These register cells are not part of some fixed memory block, they rather have individual data access. This makes them suitable for hardware control. See → SHR, → SRR, → CR and → DR. Labels have the according prefix. FEP Frontend Processing Task of the → TS where frontend measurements are performed FDB Frontend data buffer Part of the → RAM where the → frontend temporarily stores its latest measurement results (→ RAA address range from 0x80 up to maximally 0x9B) FHL, VFHL First hit level Voltage level similar to the → ZCD level, but shifted away from Zero level, for save detection of a first → hit. The FHL determines, which of the → wave periods of the receive → burst is detected as first hit. It thus has a strong influence on → TOF and must be well controlled, in order to achieve comparable TOF measurements. Fire, fire burst, fire buffer Send signal → burst The measurement signal on sending side is called fire burst, its output amplifier correspondingly fire buffer. Firmware Firmware Firmware is the combination of -> Firmware Code and -> Firmware Data. A part of it is provided by ScioSense with the possibility of extended firmware programming by customer.” Flow meter mode Operation mode of AS6031 as full flow meter system In flow meter mode, the AS6031 also performs further evaluation of → TOF results, to calculate physical results like flow and temperature. To do this, it uses a → firmware running on its internal CPU. See for comparison → time conversion mode Frontend Main measurement circuit block This part of the AS6031 chip is the main measurement device, containing the analog measurement interface (including the → TDC). The frontend provides measurement results which are stored in the → FDB. FWC Firmware Code Firmware code denotes the complete content of the → NVRAM’s 4kB section (address range 0x0000 to 0x 0FFF). The difference to the term → firmware is on the one hand that firmware code means the program in the file. On the other hand, a particular firmware code may provide just a part of the complete FWC. FWC is addressed by the CPU’s program counter, it is not available for direct read processes like RAM. Firmware code by user is limited to the address range 32 to FWU_RNG. FWD Firmware Data The firmware configuration and calibration data, to be written to the → FWD-RAM FWD-RAM Firmware Data memory 128 x 32b words of → NVRAM (built as volatile → SRAM and non-volatile flash memory). Main purpose is calibration and configuration GPIO General purpose input/output AS6031 has up to 6 GPIO pins which can be configured by the user. Some of them can be configured as → PI or → I2C-interface.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 152 Term Meaning AS6031 Interpretation Hit Stands for a detected wave period The receive → burst is typically a signal which starts with → wave periods of the measurement frequency at increasing signal levels. While the first of these wave periods are too close to noise for a reliable detection, later signal wave periods with high level can be detected safely by the → ZCD- comparator. The comparator converts the analog input signal into a digital signal, which is a sequence of hits. To detect the first hit at an increased signal level, away from noise, the input signal is compared to the → FHL. After the first hit, the level for comparison is immediately reduced to the → ZCD level, such that all later hits are detected at zero crossing (note that the ZCD level is defined to zero with respect to the receive signal, it is actually close to → Vref or another user-defined level). Different hits are denoted according to their usage:
- Hit (in general) stands for any detected → wave period.
- First hit is actually the first hit in a → TOF measurement (not the first wave period!)
- TOF hits means all hits which are evaluated for → TOF measurements. Note that typically the first hit is not a TOF hit.
- Start hit is the initial TOF hit. This is typically not the first hit, but (according to configuration) some well-defined later hit. Minimum the 3rd hit has to set as Start hit.
- Last TOF hit. It is also defined by configuration and should not be too close to the end of the receive → burst.
- Ignored hits are all hits which are not evaluated for the TOF measurement: All hits between first hit and start hit, as well any hit between TOF hits or after the stop hit. HSO High speed oscillator The 4 or 8 MHz oscillator of the AS6031. In usual operation only switched on when needed, to reduce energy consumption. This is the time base for → TDC measurements. The HSO is typically less accurate that the → LSO. It should be frequently → calibrated against the LSO to obtain the desired absolute accuracy of the → TDC. INIT Initialization process of → CPU or → FEP In AS6031 terminology, INIT processes don’t reset registers or digital IOs, while → reset does at least one of it. Several different INIT processes are implemented, see chapter “Reset hierarchy” for details. IO Input/output Connections to the outside world for input or output I2C Inter-integrated circuit bus Standard serial bus for communication with external chips. LSO Low speed oscillator The 32768 Hz crystal oscillator of the AS6031. This oscillator controls the main timing functions (→ MRG and → TS, real time clock). MRG Measurement rate generator The measurement rate generator controls the cyclic → tasks of AS6031 by setting task requests in a rate defined by configuration (→ CR). When the MRG is activated, it periodically triggers the → TS for initiating the actual → tasks. NVRAM, NVM Programmable Non- Volatile Memory AS6031 contains two sections of programmable non-volatile memory: One section of 4kB → FWC memory, and another of → FWD-RAM (FWD1:→ RAM addresses 0x100 - 0x11F and FWD2: RAM addresses 0x120 – 0x17F), in total 128 x 32b words. It is organized as a volatile SRAM part which is directly accessed from outside, and a non-volatile flash memory part. PI Pulse interface Standard 2-wire interface for flow output of a water meter. Typically outputs one pulse per some fixed water volume (e.g. one pulse per 0.1 l ), while the other wire signals the flow direction. Permits stand-alone operation and is fully compatible to mechanical water meters. PP Post Processing Processing activities of the → CPU, typically after frontend processing (e.g. a measurement) , initiated by –>TS. Can be split for post processing related to a flow measurement and to a temperature measurement Program code Program Program Code is the combination of -> Firmware Code and -> ROM Code. Program Code is addressed by CPU’s -> program counter.”
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 153 Term Meaning AS6031 Interpretation Program counter Pointer to the current code address of the → CPU The program counter addresses the currently evaluated → FWC or → ROM-code cell during → CPU operation The program counter always starts at 0xF000, when any CPU action is requested. PWR Pulse width ratio Width of the pulse the first → hit, related to the pulse width at the start hit. This width indicates the position of the → FHL relative to the level of the detected → wave period and thus gives some information on detection safety (small value means FHL is close to the peak amplitude and the desired wave period may be missed due to noise; large value indicates the danger that an earlier wave period may reach FHL level and trigger the first hit before the desired wave period). R RAM address pointer of the CPU The → CPU acts on the data of the → X-,Y- and Z-register and on one single RAM cell. The pointer R defines the address of the current RAM cell. RAA Random Access Area Address range from 0x000 to 0x1FF covering the → RAM addresses. Memory cells within this address range can all be read, most of them can also be written (except → SRR and → DR). The RAA covers memory cells of different technology: → RAM (including → FDB), → FWD-RAM ( including → CD), → direct mapped registers (→ SHR, → SRR, → CR). Holds also the asynchronous communication port registers (→ACP). RAM Random Access Memory 176 x 32b words of volatile memory, used by → FDB and → Firmware. Address range 0x000 to 0x0AF RAM address Address of a cell in the RAA range A RAM address is used by the firmware or over → RI to point to a memory cell for data storage or retrieval. Note that RAM addresses cover not only actual RAM, but all cells in the RAA range. Address range from 0x000 to 0x1FF Register Memory cell for dedicated data storage Memory cells are typically called register when they contain flags or configuration bits, or when they have a single dedicated purpose (see → CPU, → CR, → SHR and → SRR). Reset Reset of the chip AS6031 has different processes and commands that can call resets and initializations at different levels. Some of them refresh → CR or GPIO state, others just (re-) initialize CPU or frontend. The latter are rather denoted → INIT. See chapter “Reset hierarchy” for details. RI Remote Interface Interface for communication with a remote controller (see → SPI) ROM Read Only Memory 4kB of fixed memory, contains hard coded routines for general purpose and parts of ScioSense’ → program (ROM code). Address range 0xF000 – 0xFFFF. The ROM code is addressed by the CPU’s program counter, it is not available for direct read processes like RAM. ROM code Hard coded routines in ROM See → ROM. SCL Serial Clock Serial clock of I2C interface SDA Serial Data Serial data of I2C interface SHR Special Handling Register Registers that directly control chip operation. The data & flags of special handling registers have a dynamic character. They are typically updated by post processing, but some of them have to be initially configured before measurement starts. SPI Serial Peripheral Interface Standard interface for communication of the AS6031 with an external master controller SRAM Static RAM AS6031 does not use any dynamic RAM, in fact all RAM in AS6031 is static RAM. However, the term “SRAM” is in particular used for the RAM- part of the → NVRAM. SRR Status & Result Register The SRR-registers describe the current state of the chip. They are set by the chip hardware and contain error and other condition flags, timing information and so on.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 154 Term Meaning AS6031 Interpretation SUMTOF, SUMTOF_ALL Sum of up and down TOF The sum of up and down → TOF is a measure for the speed of sound in the medium, which can be used for temperature calculation. SUMTOF_ALL is the SUMTOF using → TOF_ALL results, averaged over all TOF → hits. Supervisor Functional block of AS6031 that controls voltage and timing The supervisor of AS6031 controls chip operation and timing through the measurement rate generator (→ MRG) and the task sequencer (–>TS). It also covers voltage control and adjustment functions as well as the main oscillators → LSO and >HSO Task Process, job The term task is used for a process which aims at fulfilling some fixed purpose, separate from other tasks with different goals. Typical tasks in AS6031 are → TOF measurement, temperature measurement (→ TM), post processing (→ PP), remote communication and voltage measurement. Time conversion mode Remotely controlled operation of AS6031 In time conversion mode, the AS6031 mainly acts as a → TOF measurement system. It may operate self-controlled or remotely controlled, but it does no further result evaluation. This operation mode is similar to the typical usage of the ScioSense chips GP21 and GP22. For comparison see → Flow meter mode TDC Time-to-digital-converter The core measurement device of AS6031. Measures times between a start- and a stop-signal at high accuracy and high resolution. The internal fast time base of the TDC is automatically → calibrated against the → HSO before each measurement. TOF, TOF_ALL Time of Flight Basic measurement result for an ultrasonic flow meter: The time between send and receive → burst (with some offset, depending on → hit detection). Measurements of TOF are done in flow direction (down TOF) and in the opposite direction (up TOF). AS6031 also provides the sum of all TOF → hits in the values TOF_ALL. TS Task Sequencer The task sequencer arranges and initiates the → tasks which are requested by the → MRG in one measurement cycle or which are initiated remotely. TM Temperature measurement This task means a temperature measurement using sensors, in contrast to temperatures which are calculated results from a TOF measurement (see → SUMTOF) Transducer Electromechanical conversion device Transducers for flow measurements are piezoelectric devices that convert an electrical signal into ultrasound and reverse. They are usually matched to the flow medium (e.g. water). AS6031 can connect directly to the send and receive transducer. USM Ultrasonic measurement The principle of an ultrasonic flow meter is to measure → TOFs of ultrasound in flow direction and against it, and to calculate the flow from the result. See also → transducer. In this manual this includes also the amplitude measurement. Vref Reference voltage The analog interface of AS6031 refers to Vref, a nominal voltage for → VZCD of typically 0.7V. This makes it possible to receive a DC-free AC- signal with a single supply voltage. Up to the level of Vref, negative swings of the receive signal are avoided. VZCD Zero cross detection level This voltage level represents the virtual zero line for the receive → burst. It is normally close to → Vref, just differing by the offset of the → ZCD-comparator. Needs frequent → calibration to compensate the slowly changing offset. Optionally, this voltage can be configured differently in SHR_ZCD… through the firmware. Watchdog, watchdog clear Reset timer for chip re- initialization The watchdog of AS6031 → resets the chip (including → CR refresh) if no watchdog clear (→ firmware command clrwdt) within 15.2 s (typically) is executed. This is a safety function to interrupt hang-up situations. It can be disabled for remote control, when no firmware clears the watchdog automatically.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 155 Term Meaning AS6031 Interpretation Wave period One period of the signal wave A period of typically 1us length for a 1 MHz measurement frequency. This may be a digital pulse, for example when sending, or a more sinusoidal wave when receiving. Fire or receive → bursts are sequences of wave periods. X-, Y- and Z- register Input- and result registers of the CPU The → CPU acts on these → registers for data input and result output. ZCD Zero cross detection All → hits following the first hit are detected when the received signal crosses a voltage level VZCD, defined as zero with respect to the receive → burst. In contrast, the first hit is detected when the received signal crosses the different voltage level VFHL(→ FHL). ZCD- Comparator → comparator for → hit detection The ZCD-comparator in AS6031 detects → hits in the received → burst signal by comparing the received signal level to a given reference voltage (see also → FHL, → ZCD and → hit).
15.4 CPU Commands in Detail
The following description lists every instruction which is recognized by the assembler. Most of them directly correspond to an op-code, which is a sequence of bytes in an executable code for AS6031, as it is produced by the assembler. The tabular lines have the following meaning and usage: Figure 170: Structure Command Short Description Syntax: Command name, followed by parameters p1, p2, p3… Parameters: Description of parameters. They may be registers REG [x, y, z, r] or numbers in a given range. Calculus: Mathematical operation in Verilog notation (uncommon syntax is explained in case). This line also defines the result output, which is most of the time simply p1. Note that this means that the content of p1 is changed by the operation. Flags affected: Some or all of the flags C (carry), Z (Zero), S (sign) and O (Overflow) are affected by the described operation, according to the result Bytes: Length of the complete op-code, including parameter designation Cycles: Number of calculation cycles needed by the CPU Description: Literal description and remarks on the operation Category: One of the categories in the overview There are some more expressions used in the list:
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 156
- PC: The program counter; this is actually the code address where the next CPU op-code is read.
- JUMPLABEL: Label for a jump destination, which becomes an actual code address after code assembly. In assembler code, this is usually a placeholder for a position within the code, it may also be a fixed number (not recommended). To define a jump destination by a jump label in assembler code, write the label followed by a colon.
- LSB: Least significant bit, the rightmost bit of a binary number
- MSB: Most significant bit, the leftmost bit of a binary number. In the common two’s complement representation, the MSB is used to indicate the sign of a number; MSB = 1 defines a negative number.
- “>>” or “<<”: right shift and left shift, e.g. “1<<p2”: a 1 shifted left by p2 bit positions In the following, there is a list of all CPU instructions in alphabetic order. abs Absolute value of register Syntax: abs p1 Parameters: p1 = REG [x, y, z, r] Calculus: p1 = | p1 | Flags affected: C O Z S Bytes: 2 Cycles: 2 Description: Absolute value of register Category: Simple arithmetic add Addition Syntax: add p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p1 + p2 Flags affected: C O Z S Bytes: 1 (p2 = REG) 5 (p2 = number) Cycles: 1 (p2 = REG) 5 (p2 = number) Description: Addition of two registers or addition of a constant to a register Category: Simple arithmetic and Logic AND Syntax: and p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p1 AND p2 in the resulting bit sequence in p1, a bit is 1 when the corresponding bits of P1 and P2 are both equal to 1 Flags affected: Z S
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 157 and Logic AND Bytes: 2 (p2 = REG) 6 (p2 = number) Cycles: 3 (p2 = REG) 7 (p2 = number) Description: Bitwise logic AND of 2 registers or Logic AND of register and constant Category: Logic bitclr Clear single bit Syntax: bitclr p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = number 0 to 31 Calculus: p1 = p1 and not (1<<p2) “1<<p2”: a “1” shifted left by p2 bit positions Flags affected: Z S Bytes: 2 Cycles: 2 Description: Clear the single bit on position p2 in the destination register p1, other bits remain unchanged Note: Don’t use on register R in combination with bytesel ≠ 0 Category: Bitwise bitinv Invert single bit Syntax: bitinv p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = number 0 to 31 Calculus: p1 = p1 XOR (1<<p2) “1<<p2”: a “1” shifted left by p2 bit positions Flags affected: Z S Bytes: 2 Cycles: 2 Description: Invert the single bit on position 1<<p2 in the destination register p1, other bits remain unchanged Note: Don’t use on register R in combination with bytesel ≠ 0 Category: Bitwise bitset Set single bit Syntax: bitset p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = number 0 to 31 Calculus: p1 = p1 OR (1<<p2) “1<<p2”: a “1” shifted left by p2 bit positions Flags affected: Z S Bytes: 2 Cycles: 2 Description: Set the single bit on position p2 in the destination register p1, other bits remain unchanged Note: Don’t use on register R in combination with bytesel ≠ 0
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 158 bitset Set single bit Category: Bitwise bytedir Define configuration for bytesel Syntax: bytedir p1 Parameters: p1 = number 0 or 1 Calculus: - Flags affected: - Bytes: 1 Cycles: 1 Description: Basic definition for the configuration of bytesel (see description of bytesel) p1 = 0 : align read data at LSB p1 = 1 : shift read byte(s) to various positions Important remarks: Bytedir permanently sets the read configuration until it is changed. Bytedir is not affected by any conditional or unconditional skip command. Usage within the range of any skip command is not permitted. Category: RAM access bytesel Define RAM reading mode Syntax: bytesel p1 Parameters: p1 = number 0 to 7 Calculus: - Flags affected: - Bytes: 1 Cycles: 1
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 159 bytesel Define RAM reading mode Description: Read from addressed register R using a byte-oriented shift operation in various configurations. The bytesel command is implemented to simplify bytewise operations, for example read and write from an external EEPROM, or internal selection of coefficients which are shorter than 32 Bit. It actually provides a means for fast bytewise shifting. Denoting the four bytes in the 32-Bit word in R by B3/B2/B1/B0, the following content of R is actually read, depending on the last bytedir setting: After “bytedir 0” (or without using bytedir): p1 = 0 : R is read as B3/B2/B1/B0 (default setting, no shifts) p1 = 1 : R is read as 00/00/B2/B1 p1 = 2 : R is read as 00/00/B1/B0 p1 = 3 : R is read as 00/00/B3/B2 p1 = 4 : R is read as 00/00/00/B0 p1 = 5 : R is read as 00/00/00/B1 p1 = 6 : R is read as 00/00/00/B2 p1 = 7 : R is read as 00/00/00/B3 After “bytedir 1”: p1 = 0 : R is read as B3/B2/B1/B0 (default setting, no shifts) p1 = 1 : R is read as 00/B1/B0/00 p1 = 2 : R is read as 00/00/B1/B0 p1 = 3 : R is read as B1/B0/00/00 p1 = 4 : R is read as 00/00/00/B0 p1 = 5 : R is read as 00/00/B0/00 p1 = 6 : R is read as 00/B0/00/00 p1 = 7 : R is read as B0/00/00/00 Important remarks: Bytesel affects the read direction for any register addressed as R. Any read access to R is affected, so the content of R for any operation is configured according to the list above. Bytesel has no effect in write direction. Bytesel permanently sets the read configuration until it is changed. Bytesel is not affected by any conditional or unconditional skip command. Usage within the range of any skip command is not recommended. Note that the commands bitset, bitclr or bitinv and shiftL, shiftR, rotL and rotR include read access. Set bytesel = 0 before applying one of these commands to R, to avoid undefined results. Category: RAM access clear Clear register Syntax: clear p1 Parameters: p1 = REG [x, y, z, r] Calculus: p1 = 0 Flags affected: Z S Bytes: 1 Cycles: 1 Description: Clear addressed register to 0 Category: Register wise
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 160 clkmode Clock mode Syntax: clkmode p1 Parameters: p1 = number 0 or 1 Calculus: - Flags affected: - Bytes: 2 Cycles: 2 Description: p1 = 0 : CPU clock is the internal oscillator p1 = 1 : CPU clock is 2 MHz, derived from the high speed clock (HSC) Remark: clkmode sets the clock mode permanently until the next change or until stop. After stop or after power up, clkmode is 0. Category: Miscellaneous clrC Clear flags Syntax: clrC Parameters: - Calculus: - Flags affected: C O Bytes: 2 Cycles: 2 Description: Clear Carry and Overflow flags Category: Flags clrwdt Clear watchdog Syntax: clrwdt Parameters: - Calculus: - Flags affected: - Bytes: 2 Cycles: Description: Clear watchdog. This instruction is used to restart the watchdog timer at the end of a program run. Apply clrwdt right before ‚stop‘ to avoid a reset by the watchdog, if enabled. Category: Miscellaneous compare Compare two values Syntax: compare p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: no register change; only the flags are set to the result of the operation p2 - p1 Flags affected: C O Z S
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 161 compare Compare two values Bytes: 1 (p1 = REG, p2 = REG) 5 (p1 = REG, p2 = number) Cycles: 1 (p1 = REG, p2 = REG) 5 (p1 = REG, p2 = number) Description: Comparison of the two inputs by subtraction. The flags are changed according to the subtraction result, but not the register contents themselves. Category: Simple arithmetic compl Complement Syntax: compl p1 Parameters: p1 = REG [x, y, z, r] Calculus: p1 = - p1 = ( NOT p1 ) + 1 Flags affected: Z S Bytes: 2 Cycles: 2 Description: two‘s complement of register Category: Simple arithmetic decr Decrement Syntax: decr p1 Parameters: p1 = REG [x, y, z, r] Calculus: p1 = p1 – 1 Flags affected: C O Z S Bytes: 1 Cycles: 1 Description: Decrement register by 1 Category: Simple arithmetic decramadr Decrement RAM address pointer Syntax: decramadr Parameters: - Calculus: - Flags affected: - Bytes: 1 Cycles: 1 Description: Decrement RAM address pointer by one Category: RAM access div Signed division 32 Bit Syntax: div p1, p2
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 162 div Signed division 32 Bit Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] Calculus: p1 = ( p1 << 32 ) / p2 “p1<<32”: p1 shifted left by 32 bit positions or p1 = p1*232/ p2 in standard notation condition for correct calculation: |p1| < |2*p2| In consequence, the result integers in p1 are between -0.5*232 and 0.5*232 Flags affected: Z and S according to the result in p1 Bytes: 2 Cycles: 38 Description: Signed division of 2 registers: 32 fractional bits of the division of 2 registers are assigned to p1; p2 remains unchanged Category: Complex arithmetic divmod Signed modulo division Syntax: divmod p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] Calculus: p1 = integer ( p1 / p2 ) p2 = p1 % p2 “%” is the modulo operation Flags affected: Z and S according to the result in p1 Bytes: 2 Cycles: Similar to div Description: Signed modulo division of 2 registers, 32 higher bits of the integer division of 2 registers, result is assigned to p1; the remainder is assigned to p2 Category: Complex arithmetic eor Exclusive OR Syntax: eor p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p1 XOR p2 in the resulting bit sequence in p1, a bit is 0 when the corresponding bits of P1 and P2 are equal, or 1 otherwise Flags affected: Z S Bytes: 2 (p1 = REG, p2 = REG) 6 (p1 = REG, p2 = number) Cycles: 3 (p1 = REG, p2 = REG) 7 (p1 = REG, p2 = number) Description: Bitwise Logic exclusive OR (antivalence) of the two given parameters Category: Logic eorn Exclusive NOR Syntax: eorn p1, p2
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 163 eorn Exclusive NOR Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p1 XNOR p2 in the resulting bit sequence in p1, a bit is 1 when the corresponding bits of P1 and P2 are equal, or 0 otherwise Flags affected: Z S Bytes: 2 (p1 = REG, p2 = REG) 6 (p1 = REG, p2 = number) Cycles: 3 (p1 = REG, p2 = REG) 7 (p1 = REG, p2 = number) Description: Bitwise Logic, exclusive not OR (equivalence) of the two given parameters Category: Logic equal Write 3 given Bytes to the executable code Syntax: equal p1 Parameters: p1 = 3-Byte string Calculus: - Flags affected: - Bytes: 3 Cycles: 3 (or more if an executable command was written) Description: This instruction is recognized by the assembler. It writes exactly the three bytes given in p1 to the executable code. This can be used to add customized information like version numbers. Handle with care, since the bytes will be interpreted as code when the PC points to them. Category: Miscellaneous equal1 Write 1 given Bytes to the executable code Syntax: equal1 p1 Parameters: p1 = Byte string Calculus: - Flags affected: - Bytes: 1 Cycles: 1 (or more if an executable command was written) Description: This instruction is recognized only by the assembler. It writes exactly the one byte given in p1 to the executable code. This can be used to add customized information like version numbers. Handle with care, since the byte will be interpreted as code when the PC points to it. Category: Miscellaneous getflag Set S and Z flags Syntax: getflag p1 Parameters: p1 = REG [x, y, z, r] Calculus: Signum flag S is set if p1 < 0 Zero flag Z indicates Zero if p1 = 0 Flags affected: Z S
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 164 getflag Set S and Z flags Bytes: 1 Cycles: 1 Description: Set the signum and zero flag according to the addressed register, content of the register is not affected Category: Simple arithmetic getramadr Set RAM address pointer to the value in Z Syntax: getramadr Parameters: - The input address is always taken from Z Calculus: RAM address pointer = Z Flags affected: - Bytes: 1 Cycles: 1 Description: Set the RAM address pointer to the value given in Z Category: RAM access goto jump without condition Syntax: goto p1 Parameters: p1 = JUMPLABEL Calculus: PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump without condition. Program counter (PC) is set to target address. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoBitC Jump on bit clear Syntax: gotoBitC p1, p2, p3 Parameters: p1 = REG [x, y, z, r] p2 = number [0...31] p3 = JUMPLABEL or number Calculus: if (bit p2 of register p1 == 0) if ( ( 1<<p2 and p1) == 0 ) PC = p3 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 165 gotoBitC Jump on bit clear Description: Jump on bit clear. Program counter (PC) is set to target address if selected bit p2 in register p1 is clear. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoBitS Jump on bit set Syntax: gotoBitS p1, p2, p3 Parameters: p1 = REG [x, y, z, r] p2 = number [0..31] p3 = JUMPLABEL or number Calculus: if (bit p2 of register p1 == 1) if ( ( 2p2 AND p1) == 1 ) … PC = p3 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on bit set. Program counter (PC) is set to target address if selected bit p2 in register p1 is set. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoCarC Jump on carry clear Syntax: gotoCarC p1 Parameters: p1 = JUMPLABEL or number Calculus: if (carry is clear) PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on carry clear. Program counter (PC) is set to target address if the last operation that affected the carry (C) flag left it clear. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoCarS Jump on carry set Syntax: gotoCarS p1 Parameters: p1 = JUMPLABEL or number Calculus: if (carry is set) PC = p1 Flags affected: -
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 166 gotoCarS Jump on carry set Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on carry set. Program counter (PC) is set to target address if the last operation that affected the carry (C) flag left it set. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoEQ Jump on equal zero Syntax: gotoEQ p1 Parameters: p1 = JUMPLABEL or number Calculus: if (Z indicates zero) PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on equal zero. Program counter (PC) is set to target address if the last operation that affected the zero (Z) flag indicated a zero result. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoNE Jump on not equal zero Syntax: gotoNE p1 Parameters: p1 = JUMPLABEL or number Calculus: if (Z indicates not-equal zero) PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on not-equal zero. Program counter (PC) is set to target address if the last operation that affected the zero (Z) flag indicated a not-equal zero result. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoNeg Jump on negative Syntax: gotoNeg p1 Parameters: p1 = JUMPLABEL or number
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 167 gotoNeg Jump on negative Calculus: if (S indicates negative) PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on negative. Program counter (PC) is set to target address if the last operation that affected the sign (S) flag indicated a result below 0. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoOvrC Jump on overflow clear Syntax: gotoOvrC p1 Parameters: p1 = JUMPLABEL or number Calculus: if (O is clear) PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on overflow clear. Program counter (PC) is set to target address if the last operation that affected the overflow (O) flag indicated no overflow. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump gotoOvrS Jump on overflow set Syntax: gotoOvrS p1 Parameters: p1 = JUMPLABEL Calculus: if (O is set) PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on overflow set. Program counter (PC) is set to target address if the last operation that affected the overflow (O) flag indicated an overflow. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 168 gotoPos Jump on positive Syntax: gotoPos p1 Parameters: p1 = JUMPLABEL or number Calculus: if (S indicates positive) PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump on positive. Program counter (PC) is set to target address if the last operation that affected the sign (S) flag indicated a result equal or above 0. The target address is given by using a jump label or by an absolute number. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jump The following three I2C instructions are very basic and listed for the sake of completeness only. The user is asked to access the ready-made ROM routines as described in section 15.4. i2crw I2C read / write Syntax: i2crw p1 Parameters: p1 = number 0 or 1 Description: p1 = 0 : I2C write p1 = 1 : I2C read incr Increment Syntax: incr p1 Parameters: p1 = REG [x, y, z, r] Calculus: p1 = p1 + 1 Flags affected: C O Z S Bytes: 1 Cycles: 1 Description: Increment register by one Category: Simple arithmetic incramadr Increment RAM address Syntax: incramadr Parameters: - Calculus: - Flags affected: - Bytes: 1 Cycles: 1 Description: Increment RAM address pointer by 1
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 169 incramadr Increment RAM address Category: RAM access invert Bitwise inversion Syntax: invert p1 Parameters: p1 = REG [x, y, z, r] Calculus: p1 = NOT p1 Flags affected: Z S Bytes: 2 Cycles: 2 Description: Bitwise inversion of register Category: Logic jsub Unconditional jump to a subroutine Syntax: jsub p1 Parameters: p1 = JUMPLABEL or number Calculus: PC = p1 Flags affected: - Bytes: 2 (relative jump) see section “branch instructions” 3 (absolute jump) Cycles: 3 (relative jump) see section “branch instructions” 4 (absolute jump) Description: Jump to subroutine without condition. The program counter is loaded by the address given through the parameter. The subroutine is processed until the keyword ‚jsubret‘ occurs. Then a jump back is performed and the next command after the jsub instruction is executed. Jsub needs temporarily a place in the program counter (PC) stack to remember the return address. The PC stack has a depth of 8, so jsub works for up to 8 nested calls. Jump range: 0 to 4095 (Firmware code) and 61440 to 65535 (ROM code) Category: Jsub jsubret Return from subroutine Syntax: jsubret Parameters: - Calculus: PC = PC after last jsub operation Flags affected: - Bytes: 1 Cycles: 3 Description: Return from subroutine. A subroutine called via ‚jsub‘ has to be exited by using jsubret. The program is continued at the next command following the calling jsub instruction. The address for continuing is stored in the program counter (PC) stack, which has a depth of 8. This means, the combination jsub-jsubret can be used for up to 8 nested calls. Category: Jsub
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 170 mcten Enable / disable measure cycle timer Syntax: mcten p1 Parameters: p1 = number 0 or 1 Calculus: - Flags affected: - Bytes: 2 Cycles: 2 Description: p1 = 0 : Measure cycle timer disabled p1 = 1 : Measure cycle timer enabled Category: Miscellaneous Move Move Syntax: move p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-bit number Calculus: p1 = p2 Flags affected: Z S Bytes: 1 (p1 = REG, p2 = REG) 5 (p1 = REG, p2 = number) Cycles: 1 (p1 = REG, p2 = REG) 5 (p1 = REG, p2 = number) Description: Move content of p2 to p1 (p1 = REG, p2 = REG) Move constant to p1 (p1 = REG, p2 = number) Category: Register wise mult Signed 32-Bit multiplication Syntax: mult p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] Calculus: p1, p2 = p1 * p2 the 32-bit numbers p1 and p2 are multiplied to a 64-bit result which is stored in p1 (upper 32 bits and sign) and p2 (lower 32 bits) Flags affected: Z and S according to p1 Bytes: 2 Cycles: 38 Description: Signed multiplication of two registers. Higher 32 bits of the multiplication result are placed to p1; lower 32 bits of the multiplication result are placed to p2. Note that the sign of the whole number is defined through the MSB of p1, while the MSB of p2 is just bit 31 of the result (p2 is unsigned). This can lead to misinterpretation by subsequent operations which assume signed numbers. Category: Complex arithmetic nand Logic NAND Syntax: nand p1, p2
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 171 nand Logic NAND Parameters: p1 = REG [x, y, z, r] p1 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p1 NAND p2 not (p1 AND p2); in the resulting bit sequence in p1, a bit is 0 when the corresponding bits of P1 and P2 are both equal to 1, otherwise the bit is 1 Flags affected: Z S Bytes: 2 (p1 = REG, p2 = REG) 6 (p1 = REG, p2 = number) Cycles: 3 (p1 = REG, p2 = REG) 7 (p1 = REG, p2 = number) Description: Bitwise logic NAND (negated AND) of the two input parameters Category: Logic nop No operation Syntax: nop Parameters: - Calculus: - Flags affected: - Bytes: 1 Cycles: 1 Description: Placeholder code or timing adjust, no operation. May be needed sometimes to separate two code bytes to prevent an assembler error message. Category: Miscellaneous nor Logic NOR Syntax: nor p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p1 NOR p2 p1 = not (p1 OR p2); in the resulting bit sequence in p1, a bit is 1 when the corresponding bits of P1 and P2 are both equal to 0, otherwise the bit is 0 Flags affected: Z S Bytes: 2 (p1 = REG, p2 = REG) 6 (p1 = REG, p2 = number) Cycles: 3 (p1 = REG, p2 = REG) 7 (p1 = REG, p2 = number) Description: Bitwise logic NOR (negated OR) of the two input parameters Category: Logic or Logic OR Syntax: or p1, p2
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 172 or Logic OR Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p1 OR p2 in the resulting bit sequence in p1, a bit is 0 when the corresponding bits of P1 and P2 are both equal to 0, otherwise 1 Flags affected: Z S Bytes: 2 (p1 = REG, p2 = REG) 6 (p1 = REG, p2 = number) Cycles: 3 (p1 = REG, p2 = REG) 7 (p1 = REG, p2 = number) Description: Bitwise logic OR of the two input parameters Category: Logic ramadr Set RAM address pointer Syntax: ramadr p1 Parameters: p1 = RAM cell name or 8-Bit number Calculus: - Flags affected: - Bytes: 2 Cycles: 2 Description: Set pointer to RAM address (range: 0...255) Category: RAM access rotL Rotate left Syntax: rotL p1(, p2) Parameters: p1 = REG [x, y, z, r] p2 = no entry or number 2...15 Calculus: case rotL p1, without p2: p1 = (p1 << 1) + carry ; carry = MSB(p1) p1 = 2*p1 + carry ; carry = MSB(p1) case rotL p1, p2: p1 = repeat (p2 times) rotL p1 Adding carry finally lets the bits of p1 circulate left over 1 or p2 positions. Flag affected: C O (resulting from the last rot step), Z S (according to the final result in p1) Bytes: 1 (p1 = REG, p2 = none) 2 (p1 = REG, p2 = number) Cycles: 1 (p1 = REG, p2 = none) 1 + p2 (p1 = REG, p2 = number) Description: Without p2 or p2 = 1 : Rotate p1 left by one bit position over carry. This means in detail, shift p1 register to the left, fill LSB with present carry, then move the former MSB to carry. With 2 ≤ p2 ≤ 15 : Rotate p1 left by p2 bit positions over carry. This means in detail, shift p1 register p2 times to the left, in each step fill LSB with the present carry and then move the former MSB to carry. Note: Don’t use on register R in combination with bytesel ≠ 0 Category: Shift and rotate
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 173 rotR Rotate right Syntax: rotR p1(, p2) Parameters: p1 = REG [x, y, z, r] p2 = no entry or number 2...15 Calculus: case rotR p1, without p2: p1 = (p1 >> 1) + (carry << 31) ; carry = LSB(p1) → Carry is shifted left to position 31, or p1 = integer ( p1 / 2) + (carry*231) ; carry = LSB(p1) case rotR p1, p2: p1 = repeat (p2 times) rotL p1 Placing carry at MSB lets the bits of p1 circulate right over 1 or p2 positions. Flags affected: C O (resulting from the last rot step), Z S (according to the final result in p1) Bytes: 1 (p1 = REG, p2 = none) 2 (p1 = REG, p2 = number) Cycles: 1 (p1 = REG, p2 = none) 1 + p2 (p1 = REG, p2 = number) Description: Without p2 or p2 = 1 : Rotate p1 right by one bit position over carry. This means in detail, shift p1 register to the right, fill MSB with present carry, then move the former LSB to carry. With 2 ≤ p2 ≤ 15 : Rotate p1 right by p2 bit positions over carry. This means in detail, shift p1 register p2 times to the right, in each step fill MSB with the present carry and then move the former LSB to carry. Note: Don’t use on register R in combination with bytesel ≠ 0 Category: Shift and rotate setC Set carry flag Syntax: setC Parameters: - Calculus: - Flags affected: C O Bytes: 2 Cycles: 2 Description: Set carry flag and clear overflow flag Category: Flags shiftL Shift Left Syntax: shiftL p1(, p2) Parameters: p1 = REG [x, y, z, r] p2 = no entry or number 2...15 Calculus: case shiftL p1, without p2: p1 = (p1 << 1); carry = MSB(p1) “p1 << 1”: p1 shifted left by 1 bit, actually means p1 multiplied by 2 in standard notation: p1 = 2 *p1 as long as MSB remains unchanged case shiftL p1, p2: p1 = repeat (p2 times) shiftL p1 in standard notation: p1 = p1*2p2 as long as MSB remains unchanged Flags affected: C O (resulting from the last shift step), Z S (according to the final result in p1) Bytes: 1 (p1 = REG, p2 = none) 2 (p1 = REG, p2 = number)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 174 shiftL Shift Left Cycles: 1 (p1 = REG, p2 = none) 1 + p2 (p1 = REG, p2 = number) Description: Without p2 or p2 = 1 : Unsigned Shift p1 left by one bit position, LSB set to zero, MSB shifted out to carry. Note that this can cause fake sign changes. With 2 ≤ p2 ≤ 15 : Unsigned Shift p1 left by p2 bit positions, b2 lower bits set to zero, MSB of last step shifted out to carry. Note that this operation can cause fake sign changes. Check by OVL flag Note: Don’t use on register R in combination with bytesel ≠ 0 Category: Shift and rotate shiftR Shift right Syntax: shiftR p1(, p2) Parameters: p1 = REG [x, y, z, r] p2 = no entry or number 2...15 Calculus: case shiftR p1, without p2: p1 = (p1 >> 1); carry = LSB(p1) “p1 >> 1”: p1 shifted right by 1 bit, actually means p1 divided by 2 in standard notation: p1 = p1 /2 with a truncation error if LSB(p1)=1 case shiftR p1, p2: p1 = repeat (p2 times) shiftR p1 in standard notation: p1 = p1/2p2 with some truncation error due to lost lower bits Flags affected: C O (resulting from the last shift step), Z S (according to the final result in p1) Bytes: 1 (p1 = REG, p2 = none) 2 (p1 = REG, p2 = number) Cycles: 1 (p1 = REG, p2 = none) 1 + p2 (p1 = REG, p2 = number) Description: Without p2 or p2 = 1 : Signed Shift p1 right by one bit position, MSB duplicated to keep sign unchanged, LSB shifted out to carry. The latter can be used to correct a possible truncation error. With 2 ≤ p2 ≤ 15 : Signed Shift p1 right by p2 bit positions, p2 leading bits set to initial MSB to keep sign unchanged. Carry is set to the last LSB shifted out, which can be used to reduce a possible truncation error. Note: Don’t use on register R in combination with bytesel ≠ 0 Category: Shift and rotate sign Sign Syntax: sign p1 Parameters: p1 = REG [x, y, z, r] Calculus: p1 = 1 = 0x00000001 if p1 >= 0 p1 = -1 = 0xFFFFFFFF if p1 < 0 Flags affected: Z S Bytes: 2 Cycles: 2 Description: Sign of addressed register in complement of two notations. A positive value returns 1, a negative value returns -1 Zero is assumed to be positive Category: Simple arithmetic
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 175 skip Skip Syntax: skip p1 Parameters: p1 = number [1, 2, 3] Calculus: PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 instructions without conditions. The one, two or three active instructions following the skip command produce no result, except some instructions that may not be skipped (see below). Note that the skipped instructions are processed, but they produce no result or further activity. Use the skip commands (conditional or unconditional) for structured programming or to ignore very short code sequences – for long sequences goto is more effective. Note: The following instructions may not be skipped: bytedir, bytesel, clkmode, clrwdt, equal, equal1, i2crw, mcten Category: Skip skipBitC Skip on bit clear Syntax: skipBitC p1, p2,p3 Parameters: p1 = REG [x, y, z, r] p2 = number [0...23] p3 = number [1, 2, 3] Calculus: if (bit p2 of register p1 == 0) PC = PC + code bytes of next p3 instructions Flags affected: - Bytes: 2 Cycles: 2 + cycles of the skipped commands Description: Skip p3 commands if bit p2 of register p1 is clear. See “skip” for more details. Category: Skip skipBitS Skip on bit set Syntax: skipBitS p1, p2,p3 Parameters: p1 = REG [x, y, z, r] p2 = number[0...23] p3 = number[1, 2, 3] Calculus: if (bit p2 of register p1 == 1) PC = PC + code bytes of next p3 instructions Flags affected: - Bytes: 2 Cycles: 2 + cycles of the skipped commands Description: Skip p3 commands if bit p2 of register p1 is set. See “skip” for more details. Category: Skip
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 176 skipCarC Skip carry clear Syntax: skipCarC p1 Parameters: p1 = number [1, 2, 3] Calculus: if (carry == 0) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 commands if carry clear. See “skip” for more details. Category: Skip skipCarS Skip carry set Syntax: skipCarS p1 Parameters: p1 = number [1, 2, 3] Calculus: if (carry == 1) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 commands if carry set. See “skip” for more details. Category: Skip skipEQ Skip on zero Syntax: skipEQ p1 Parameters: p1 = number [1, 2, 3] Calculus: if (Z indicates zero) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 commands if result of previous operation is equal to zero. See “skip” for more details. Category: Skip skipNE Skip on non-zero Syntax: skipNE p1 Parameters: p1 = number [1, 2, 3] Calculus: if (Z indicates not-equal zero) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 177 skipNE Skip on non-zero Description: Skip p1 commands if result of previous operation is not equal to zero. See “skip” for more details. Category: Skip skipNeg Skip on negative Syntax: skipNeg p1 Parameters: p1 = number [1, 2, 3] Calculus: if (S indicates negative) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 commands if result of previous operation was smaller than 0. See “skip” for more details. Category: Skip skipOvrC Skip on overflow clear Syntax: skipOvrC p1 Parameters: p1 = number [1, 2, 3] Calculus: if (O is clear) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 commands if overflow is clear. See “skip” for more details. Category: Skip skipOvrS Skip on overflow set Syntax: skipOvrS p1 Parameters: p1 = number [1, 2, 3] Calculus: if (O is set) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 commands if overflow is set. See “skip” for more details. Category: Skip skipPos Skip on positive Syntax: skipPos p1 Parameters: p1 = number [1, 2, 3]
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 178 skipPos Skip on positive Calculus: if (S indicates positive) PC = PC + code bytes of next p1 instructions Flags affected: - Bytes: 1 Cycles: 1 + cycles of the skipped commands Description: Skip p1 commands if result of previous operation was greater or equal to 0. See “skip” for more details. Category: Skip stop Stop Syntax: stop Parameters: - Calculus: - Flags affected: - Bytes: 1 Cycles: 1 Description: The CPU and the CPU clock are stopped. Usually this instruction is the last command in the assembler listing, it ends any CPU activity. New activity starts by request of the task sequencer or over external communication. Note that the request flag that started the CPU activity must be cleared by the CPU before stop, to indicate that this request was processed. Category: Miscellaneous sub Subtraction Syntax: sub p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] or 32-Bit number Calculus: p1 = p2 – p1 Flags affected: C O Z S Bytes: 1 (p1 = REG, p2 = REG) 5 (p1 = REG, p2 = number) Cycles: 1 (p1 = REG, p2 = REG) 5 (p1 = REG, p2 = number) Description: Subtraction of the two parameters Category: Simple arithmetic swap Swap Syntax: swap p1, p2 Parameters: p1 = REG [x, y, z, r] p2 = REG [x, y, z, r] Calculus: p1 = p2 and p2 = p1 Flags affected: -
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 179 swap Swap Bytes: 1 Cycles: 3 Description: Swap of 2 registers. The value of two registers is exchanged between each other. Category: Register wise
15.5 ROM Routines in Detail
15.5.1 Data Filtering
ROM routine name ROM_INIT_FILTER / ROM_INIT_FILTER1
Description
Routine to initialize the RAM cells for any block of RAM cells of size N and starting at a given address with a given value (use to initialize rolling average filter). The routine has an alternative start address ROM_INIT_FILTER1, where RAM_R_V32_FILTER remains unchanged, but Y returns undefined. Prerequisite - Input parameters / register values X: contains value to be initialized in the RAM cells (any format) Y: Number of RAM cells to be initialized N (integer) Z: Starting RAM Address of the filter Output/Return value NVRAM cells starting at the address in Z are initialized with the value in X Temporary RAM RAM_R_V32_FILTER (remains unchanged when using ROM_INIT_FILTER1) Permanent RAM - Routines used - Unchanged registers X, Z; (Y unchanged when using ROM_INIT_FILTER) ROM routine name ROM_ROLL_AVG This routine averages a list of the last N FILTER_IN values using a rolling average filter. With every call it removes the oldest value from the list end and adds the new one at the beginning. Then it determines the new average by calculating the arithmetic mean from the N list values. The final output value must not exceed the maximal representable number/N in the chosen format (else overflow occurs). Prerequisite For correct results, all N RAM cells of the filter must contain valid values. Use ROM_INIT_FILTER once before first routine call for proper initialization. Input parameters / register values X: new value to be added to the filter list (FILTER_IN) (any format) Y: filter length N (integer) Z: Starting address of the rolling average filter RAM cell block of length N Output/Return value X: new average (same format as X input)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 180 ROM routine name ROM_ROLL_AVG Temporary RAM RAM_R_V32_FILTER Permanent RAM - Routines used - Unchanged registers (all registers X, Y, Z and R are in use) ROM routine name ROM_ROLLAVG_2OUTLIER This routine averages a list of the last N FILTER_IN values using a rolling average filter. With every call it removes the oldest value from the list end and adds the new one at the beginning. Then it determines the new average by calculating the arithmetic mean from the N list values – except the one value that deviates the most from the last average (the OUTLIER). This one value is replaced by the previous one (ONLY for the calculation, the original value remains in the list), in order to filter out single error points. The final output value must not exceed the maximal representable number/N in the chosen format (else overflow occurs). Prerequisite For correct results, all N RAM cells of the filter must contain valid values. Use ROM_INIT_FILTER once before first routine call for proper initialization. Input parameters / register values X: new value to be added to the filter list (FILTER_IN) (any format) Y: filter length N (integer) Z: Starting address of the rolling average filter RAM cell block of length N RAM_R_V30_PREV_AVG with the previous averaged result Output/Return value X: new average (same format as X input) Z: last valid value that replaced the OUTLIER (same format as X input) Bit BNR_NEW_VAL_IS_OUTLIER in RAM_R_FW_STATUS is set if the current new value is then OUTLIER – to be recognized for later error handling, for example to replace the new value by Z in other calculations. Temporary RAM RAM_R_V32_FILTER, RAM_R_V31_FILTER_2, RAM_R_V33_FILTER_SUM Permanent RAM RAM_R_FW_STATUS, RAM_R_V30_PREV_AVG Routines used - Unchanged registers (all registers X, Y, Z and R are in use) ROM routine name ROM_FILTER_FLOW Routine to filter the flow value with a rolling average filter of length 16. The routine initializes the filter at its first call with its input value and calculates with each new call a new averaged flow value with the oldest value replaced by the new input from The final output value must not exceed the maximal representable number/16 in the chosen format (else overflow occurs). Prerequisite All 16 filter cells in RAM, starting at RAM_R_ROLAVG_1, must still contain the former values. Input parameters / register values RAM_R_VA2_FLOW_LPH_TO_FLT (any format) Output/Return value X: averaged flow value (same format as input) Values in 16 filter cells in RAM, starting at RAM_R_ROLAVG_1, are shifted by one cell, dropping the oldest value at the end and storing the new input value in RAM_R_ROLAVG_1 First call: all 16 filter cells get initialized to RAM_R_VA2_FLOW_LPH_TO_FLT, and Bit BNR_FLOW_FILT_INIT_DONE in RAM_R_FW_STATUS is set.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 181 ROM routine name ROM_FILTER_FLOW Temporary RAM - Permanent RAM RAM_R_FW_STATUS, RAM_R_VA2_FLOW_LPH_TO_FLT, RAM_R_ROLAVG_1, RAM_ ROLAVG_2 . RAM_ROLAVG_16 Routines used ROM_INIT_FILTER, ROM_ROLL_AVG Unchanged registers (all registers X, Y, Z and R are in use)
15.5.2 Error Detection and Handling
ROM routine name ROM_EH Description Error Handling: This routine checks all error flags and suppresses processing of wrong results. Prerequisite - Input parameters / register values error flags in SRR_ERR_FLG Output/Return value error counters and flags are updated. Temporary RAM - Permanent RAM RAM_R_FW_STATUS, RAM_R_PT_INT_TEMPERATURE, RAM_R_PTC_TEMPERATURE, RAM_R_PTC_TEMPERATURE, RAM_R_V2D_PT_INT_TEMPERATURE_OLDVAL, RAM_R_V2B_PTC_TEMPERATURE_OLDVAL, RAM_R_V2C_PTH_TEMPERATURE_OLDVAL, RAM_R_FHL_ERR_CTR, RAM_R_FLOW_LPH, RAM_R_THETA, RAM_R_V29_FLOW_LPH_OLDVAL, RAM_R_V2A_FLOW_THETA_OLDVAL Routines used ROM_REPLACE_WITH_OLD_TOFS Unchanged registers Z ROM routine names ROM_PP_AM_MON / ROM_PP1_AM_MON AM monitoring: This routine reads the raw amplitude values from the front end data buffer and checks if they are above the user given limit in FWD_R_AM_MIN. This is done by direct comparison of FDB_US_AM_U and FDB_US_AM_D with RAM_R_AM_MIN_RAW (provided by ROM_PP_AM_CALIB or ROM_PP1_AM_CALIB). The routine sets the flag BNR_AMP_VAL_TOO_LOW bit in RAM_R_FW_ERR_FLAGS register, if any of the amplitudes is too low, or clears it in the opposite case (sufficient signal amplitudes). The alternative call ROM_PP1_AM_MON does not need the RAM cell RAM_R_AM_MIN_RAW, it gets the same value from Z. Prerequisite An AM measurement must be done before, with valid results in FDB_US_AM_U and FDB_US_AM_D. Input parameters / register values RAM_R_AM_MIN_RAW: Min. amplitude raw value in HSC periods (fd 16) equivalent to the user’s minimum amplitude limit FWD_R_AM_MIN in mV. or alternatively, with ROM_PP1_AM_MON, use Z instead as input: Z: Minimal. amplitude raw value in HSC periods (as above) (fd 16) Output/Return value BNR_AMP_VAL_TOO_LOW in RAM_R_FW_ERR_FLAGS register Temporary RAM - Permanent RAM RAM_R_FW_ERR_FLAGS only ROM_PP_AM_MON: RAM_R_AM_MIN_RAW
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 182 ROM routine names ROM_PP_AM_MON / ROM_PP1_AM_MON Routines used - Unchanged registers X, Y ROM routine name ROM_PP_AM_CALIB / ROM_PP1_AM_CALIB These routines are used after an amplitude calibration measurement. Using the new amplitude calibration values (FDB_US_AMC_VH and FDB_US_AMC_VL), they calculate gradient RAM_R_AMC_GRADIENT and offset RAM_R_AMC_OFFSET that are needed for calculating actual amplitudes (this is not done here, see manual for equations). In addition, they scale the amplitude limit FWD_R_AM_MIN into an equivalent raw value RAM_R_AM_MIN_RAW, which can be directly compared to measured time values. This avoids frequent multiplications or divisions. Note that all calculated values change slowly over time, so they need to be updated rarely, but regularly. The routine ROM_PP_AM_CALIB uses a hard-coded typical AM amplitude value of 350mV as reference. The alternative call ROM_PP1_AM_CALIB has an input cell from firmware data (FWD_R_VCAL_TYP) instead, such that the voltage reference can be adapted if necessary. Applied formulae: RAM_R_AMC_GRADIENT = VCAL/ (FDB_US_AMC_VH - FDB_US_AMC_VL) RAM_R_AMC_OFFSET = (2 * FDB_US_AMC_VL - FDB_US_AMC_VH) * RAM_R_AMC_GRADIENT (note: for subsequent amplitude calculations, RAM_R_AMC_OFFSET must be further corrected outside the routine: offset = RAM_R_AMC_OFFSET +(SHR_ZCD_LVL - 796)*0.9V/1024 ) RAM_R_AM_MIN_RAW = (FWD_R_AM_MIN + AMC_OFFSET + AM_CORR_FACTOR) / AMC_GRADIENT AM_CORR_FACTOR= (SHR_ZCD_LVL - 796) * 0.9V /1024 SHR_ZCD_LVL is the current zero cross detection level (LSB 0.88mV). Prerequisite AM calibration measurements must be done before, with valid results in FDB_US_AMC_VH and FDB_US_AMC_VL. The zero cross detection level SHR_ZCD_LVL must be adjusted. All these parameters are assumed to change slowly enough to be considered constant between two AM calibrations. Input parameters / register values FWD_R_AM_MIN: User given lower amplitude limit in mV (fd 16) only ROM_PP1_AM_CALIB: FWD_R_VCAL_TYP: reference amplitude in mV (integer) Output/Return value X = RAM_R_AM_MIN_RAW in HSC periods: (fd 16) raw lower amplitude limit for direct measurement comparison Y = RAM_R_AMC_GRADIENT in mV/HSC period, (fd 16) RAM_R_AMC_OFFSET in mV: (fd 16) parameters for calculation of amplitudes in mV from FDB_US_AM_U and FDB_US_AM_D (use raw values in HSC periods) Temporary RAM RAM_R_VA9_AMC_DIFF Permanent RAM FWD_R_AM_MIN, RAM_R_AM_MIN_RAW, RAM_R_AMC_GRADIENT, RAM_R_AMC_OFFSET; only ROM_PP1_AM_CALIB: FWD_R_VCAL_TYP Routines used ROM_FORMAT1_64_TO_32BIT Unchanged registers (all registers X, Y, Z and R are in use)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 183
15.5.3 Pulse Interface and Flow Volume
ROM routine name ROM_CFG_PULSE_IF This routine configures the pulse interface with the parameters calculated from the given configuration. The routine thus prepares the use of ROM_PI_UPD for flow output over the pulse interface. The implemented configuration aims at generating not more than one pulse per auto update, to prevent multiple pulses. Prerequisite - Input parameters / register values X : Number of pulses per liter (PULSE_PER_LITER) (integer) Y : Maximum flow in liter per hour (MAX_FLOW) (integer) Z : MEAS_RATE_INV = ((TS_CM + 1) * TS_CT * TOF_RATE) / 1024 (fd 16) - TS_CM : Cycle mode (Task sequencer) - TS_CT: Cycle time (Task sequencer) - TOF_RATE: Time of Flight Rate - HS_CLK = 4 MHz Output/Return value Pulse interface registers SHR_PI_AU_NMB, SHR_PI_AU_TIME, SHR_PI_TPA and the PI_TPW bits in CR_PI are configured. X: FLOW_SCALE_FACT = PULSE_PER_LITER*MEAS_RATE_INV (fd 16) The FLOW_SCALE_FACT is used to be multiplied with the actual flow (l/h) for updating the pulse interface. It is typically applied by moving it to RAM_R_FLOW_SCALE_FACT before calling ROM_PI_UPD. Temporary RAM RAM_R_VA4_FLOWVAR_2, RAM_R_VA5_FLOWVAR_1 Permanent RAM - Routines used ROM_DIV_BY_SHIFT Unchanged registers (all registers X, Y, Z and R are in use) ROM routine name ROM_PI_UPD Pulse Interface Update routine This routine calculates the number of pulses equivalent to a given flow (in l/h), based on the configuration settings, and initializes it in the SHR_PI_NPULSE register. Prerequisite ROM_CFG_PULSE_IF must be called ONCE before using this routine, and the resulting FLOW_SCALE_FACTOR must be moved to RAM_R_FLOW_SCALE_FACT. Input parameters / register values X : Flow in liter per Hour (fd 16) RAM_R_FLOW_SCALE_FACT must contain FLOW_SCALE_FACT (fd 16) (using ROM_CFG_PULSE_IF routine, see above) Output/Return value SHR_PI_NPULSE register is updated with the Number of Pulses equivalent to the current flow in l/h. Temporary RAM RAM_R_VA5_FLOWVAR_1 Permanent RAM RAM_R_FLOW_SCALE_FACT Routines used - Unchanged registers (all registers X, Y, Z and R are in use)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 184 ROM routine name ROM_PP_PI_UPD Description This routine organizes the update of the pulse interface by calling ROM_PI_UPD with RAM_R_FLOW_LPH as input argument. Prerequisite - Input parameters / register values RAM_R_FLOW_LPH: current flow in l/h (fd 16) Output/Return value SHR_PI_NPULSE register is updated with the Number of Pulses equivalent to the current flow in l/h. Temporary RAM - Permanent RAM RAM_R_FLOW_LPH Routines used ROM_PI_UPD Unchanged registers (all registers X, Y, Z and R are in use) ROM routine names ROM_SAVE_FLOW_VOLUME / ROM_SAVE01_FLOW_VOLUME ROM_SAVE1_FLOW_VOLUME / ROM_SAVE11_FLOW_VOLUME ROM_SAVE2_FLOW_VOLUME / ROM_SAVE21_FLOW_VOLUME These routines are used to calculate the flow volume of one measurement cycle from the present flow (usually in l/h) and store it cumulatively to flow volume (usually in cubic meter). Operation: FLOW_LPH * VOLUME_FACTOR (V.F.) -> flow (e.g. in cubic meters) per cycle -> accumulate (add to/subtract from) the flow volume (integer and fractional part) Calculation steps for VOLUME_FACTOR for liter -> l/h: a) FLOW_LPH/3600 -> FLOW_LPS b) FLOW_LPS * MEAS_RATE_INV -> FLOW in liter per meas. cycle c) Flow in liter per meas. cycle/1000 -> Flow in cubic meter per cycle d) Flow in cubic meter per cycle -> add it to the Flow Volume (integer and fractional part) Actual calculation of the VOLUME_FACTOR from configuration data: VOLUME_FACTOR = [(TS_CM + 1) * TS_CT * TOF_RATE] / [1024*3600*1000] Here the following configuration parameters are used: - TS_CM : Cycle mode (Task sequencer) - TS_CT: Cycle time (Task sequencer) - TOF_RATE: Time of Flight Rate - HS_CLK =4 MHz The actual decision on units is done by the user through defining the appropriate input scaling (l/h or something else) and VOLUME_FACTOR. Difference between the routine calls: The routines operate either on usual RAM or on firmware data (FWD) RAM, which is useful for regular permanent storage. Their input comes from X, Y or RAM, and can have different meaning (see below). ROM routine name RAM region: input from: parameter meaning: 1ROM_SAVE_FLOW_VOLUME RAM RAM Flow & V.F. 2ROM_SAVE1_FLOW_VOLUME RAM X,Y Flow & V.F. 3ROM_SAVE2_FLOW_VOLUME FWD X,Y Flow & V.F. 5ROM_SAVE01_FLOW_VOLUME, 6ROM_SAVE11_FLOW_VOLUME RAM X,Y Volume
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 185 ROM routine names ROM_SAVE_FLOW_VOLUME / ROM_SAVE01_FLOW_VOLUME ROM_SAVE1_FLOW_VOLUME / ROM_SAVE11_FLOW_VOLUME ROM_SAVE2_FLOW_VOLUME / ROM_SAVE21_FLOW_VOLUME 7ROM_SAVE21_FLOW_VOLUME, FWD X,Y Volume Prerequisite depending on actual call, see above The RAM cells RAM_R_FLOW_VOLUME_INT and RAM_R_FLOW_VOLUME_FRACTION must contain the flow volume of previous measurements. 1,4RAM cells used for input must contain the right parameter (see above) Input parameters / register values: The meaning of input depends on the actual call, see above. 2,3X or 4FWD_R_FLOW_LPH or 1RAM_R_FLOW_LPH: the present flow value (fd 16, usually in l/h) or 5,6,7,8X: the additional flow volume (fd 32, usually cubic meters) 2,3Y or 4FWD_R_VOLUME_FACTOR or 1FWD_R_VOLUME_FACTOR: VOLUME_FACTOR (fd 44; note that this is usually a very small number, so the upper 12 fractional digits are zero and “above” the actual data word) or 5,6,7,8Y = X Output/Return value Output may be in usual RAM or FWD, depending on actual call, see above. 64-bit Volume Flow result in RAM Addresses 1,2,5,6RAM_R_FLOW_VOLUME_INT (integer, usually in cubic meters) RAM_R_FLOW_VOLUME_FRACTION (fd 32, usually in cubic meters) or 3,4,7,8FWD_R_FLOW_VOLUME_INT (integer, usually in cubic meters) FWD_R_FLOW_VOLUME_FRACTION (fd 32, usually in cubic meters) Temporary RAM - Permanent RAM depending on actual call, see above 1,2,5,6RAM_R_FLOW_VOLUME_INT, RAM_R_FLOW_VOLUME_FRACTION or 3,4,7,8FWD_R_FLOW_VOLUME_INT, FWD_R_FLOW_VOLUME_FRACTION; 1RAM_R_FLOW_LPH, RAM_R_VOLUME_FACTOR or 4RAM_R_FLOW_LPH, RAM_R_VOLUME_FACTOR Routines used - Unchanged registers (all registers X, Y, Z and R are in use)
15.5.4 Temperature Measurement
ROM routine name ROM_TEMP_POLYNOM This routine calculates the temperature of a PT sensor in °C using the polynomial approximation Temperature T = {[(PT_COEFF2 * PT_RATIO) + PT_COEFF1] * PT_RATIO } + PT_COEFF0 where PT_RATIO = PT_RES / R0 of the PT sensor PT_COEFF2 = 10.115 (fd 16) PT_COEFF1 = 235.57 (fd 16) PT_COEFF0 = -245.683 (fd 16) This polynomial resembles the inverted R(T)-polynomial for PT (according to IEC 60751:2008) within 3mK accuracy between 0°C and 100°C. Prerequisite - Input parameters / register values X: PT_RATIO (fd 16)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 186 ROM routine name ROM_TEMP_POLYNOM Output/Return value X: Temperature in °C (fd 16) Temporary RAM - Permanent RAM - Routines used ROM_FORMAT1_64_TO_32BIT Unchanged registers (all registers X, Y, Z and R are in use) ROM routine name ROM_TEMP_LINEAR_FN This routine is used to calculate the temperature of any sensor as a linear function of sensor resistance using the nominal resistance and sensor slope. Applied formula: Temperature T = (Sensor Resistance at T[°C] – Nominal resistance) / RAM_R_VAF_REF_RES_VAL * Sensor slope Prerequisite - Input parameters / register values X: Nominal resistance (fd 16) Y: Sensor slope (fd 16) Z: Sensor resistance (fd 16) RAM_R_VAF_REF_RES_VAL: Reference Resistance (fd 16) Output/Return value X: Temperature (fd 16) Temporary RAM - Permanent RAM RAM_R_VAF_REF_RES_VAL Routines used ROM_FORMAT1_64_TO_32BIT Unchanged registers (all registers X, Y, Z and R are in use) ROM routine name ROM_TM_SUM_RESULT In sensor temperature measurement, each single time measurement is repeated after some fixed delay time. Averaging these results eliminates a possible 50/60 Hz disturbance. This routine sums up all duplicate measurements (from the frontend data buffer in cells for measurement 1 and 2) and stores it in the frontend data buffer (in the cells of measurement 1). The routine works for all 2-wire or 4-wire temperature measurement results, it reads the configuration from CR_TM. Prerequisite The routine should be called directly after a temperature measurement. Input parameters / register values All frontend data buffer (FDB) cells (addresses 0x80 – 0x9B) Output/Return value The added results overwrite the original measurements in the first measurement FDB cells (addresses 0x80- 0x84 and 0x8A - 0x92) Temporary RAM - Permanent RAM - Routines used - Unchanged registers (all registers X, Y, Z and R are in use)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 187
15.5.5 Interface Communication
ROM routine name ROM_I2C_ST Description I2C Start Byte Transfer: Initiate an I2C read or write operation, depending on preceding i2crw-command ( 1=read, 0=write ). Prerequisite I2C slave device address must be defined in CR_PI_I2C. Read or write direction must be defined by command i2crw ( 1=read, 0=write ). Input parameters / register values - Output/Return value SRR_MSC_STF contains a flag to indicate I2C acknowledge (Bit I2C_ACK). Temporary RAM - Permanent RAM - Routines used - Unchanged registers X, Y, Z, R ROM routine name ROM_I2C_BT Description I2C Byte Transfer: Read or write one byte of data over I2C, depending on preceding i2crw-command ( 1=read, 0=write ). Prerequisite I2C slave device address must be defined in CR_PI_I2C. Read or write direction must be defined by command i2crw ( 1=read, 0=write ).In write case, R must point to the desired input RAM cell, and usually the bytedir and bytesel command must be used to select the desired byte part of the 4Byte-word in the RAM cell (use bytedir 0 and bytesel 4, 5, 6 or 7). Input parameters / register values R is not changed but used as pointer to the data register by the chip hardware in write case (see “Prerequisite”). Output/Return value SRR_MSC_STF contains a flag to indicate I2C acknowledge (Bit I2C_ACK). In read case, SRR_E2P_RD contains the transferred byte. For storing the received byte in a 4Byte RAM cell, use the bytedir and bytesel command to select the desired byte position (use bytedir 1 and bytesel 4, 5, 6 or 7, and the or command to add a new byte to a partly filled 4Byte-word). Temporary RAM - Permanent RAM - Routines used - Unchanged registers X, Y, Z, R ROM routine name ROM_I2C_LT I2C Byte Transfer: Read or write the last transmitted byte of data over I2C, depending on preceding i2crw-command ( 1=read, 0=write ). The routine sends the stop signal at the end of transmission. Prerequisite I2C slave device address must be defined in CR_PI_I2C. Read or write direction must be defined by command i2crw ( 1=read, 0=write ).In write case, R must point to the desired input RAM cell, and usually the bytedir and bytesel command must be used to select the desired byte part of the 4Byte-word in the RAM cell (use bytedir 0 and bytesel 4, 5, 6 or 7). Input parameters / register values R is not changed but used as pointer to the data register by the chip hardware in write case (see “Prerequisite” below).
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 188 ROM routine name ROM_I2C_LT Output/Return value SRR_MSC_STF contains a flag to indicate I2C acknowledge (Bit I2C_ACK). In read case, SRR_E2P_RD contains the transferred byte. For storing the received byte in a 4Byte RAM cell, use the bytedir and bytesel command to select the desired byte position (use bytedir 1 and bytesel 4, 5, 6 or 7, and the or command to add a new byte to a partly filled 4Byte-word). Temporary RAM - Permanent RAM - Routines used - Unchanged registers X, Y, Z, R ROM routine name ROM_I2C_DWORD_WR This routine is used to write a 4 byte-word of data to the I2C slave device, starting at a given memory address. The device address for the I2C device is taken automatically from I2C slave address of CR_PI_I2C. The routine starts with switching on the HSC and switches it off after transmission. It thus causes a high current consumption and has a long runtime. In power critical applications, its use should thus be restricted. Timing properties of the I2C slave should also be considered (e.g. long storing times after some data transmission). Prerequisite - Input parameters / register values X: 16-bit memory address (start) where the data has to be written Y: 4 bytes of data Output/Return value The four bytes from Y are written to the I2C slave, starting at the address given in X. In case of an error, the transmission was not acknowledged by the I2C slave device and bit BNR_I2C_ABORT of RAM_R_FW_STATUS is set. Temporary RAM - Permanent RAM RAM_R_VA1_I2CADDR, RAM_R_VA2_I2CDATA, RAM_R_FW_STATUS Routines used ROM_I2C_ST, ROM_I2C_BT, ROM_I2C_LT Unchanged registers Z ROM routine name ROM_I2C_BYTE_WR This routine is used to write a single of data to the I2C slave device to given memory address. The device address for the I2C device is taken automatically from I2C slave address of CR_PI_I2C. The routine starts with switching on the HSC and switches it off after transmission. It thus causes a high current consumption and has a long runtime. In power critical applications, its use should thus be restricted. Timing properties of the I2C slave should also be considered (e.g. long storing times after some data transmission). Prerequisite - Input parameters / register values X: 16-bit address where the data has to be written Y: 1 byte of data (B0 of the 32 bit-word in Y is transferred) Output/Return value Byte B0 from Y is written to the I2C slave to the address given in X. In case of an error, the transmission was not acknowledged by the I2C slave device and bit BNR_I2C_ABORT of RAM_R_FW_STATUS is set. Temporary RAM - Permanent RAM RAM_R_VA1_I2CADDR, RAM_R_VA2_I2CDATA, RAM_R_FW_STATUS Routines used ROM_I2C_ST, ROM_I2C_BT, ROM_I2C_LT Unchanged registers Z
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 189 ROM routine name ROM_I2C_DWORD_RD This routine is used to sequentially read 4 data bytes from the I2C slave device, starting at a given memory address. The device address for the I2C device is taken automatically from I2C slave address of CR_PI_I2C. The routine starts with switching on the HSC and switches it off after transmission. It thus causes a high current consumption and has a long runtime. In power critical applications, its use should thus be restricted. Timing properties of the I2C slave should also be considered. Prerequisite - Input parameters / register values X: 16-bit memory address (start) where the data is read. Output/Return value X: 4 bytes of read data In case of an error, the transmission was not acknowledged by the I2C slave device and bit BNR_I2C_ABORT of RAM_R_FW_STATUS is set. Temporary RAM - Permanent RAM RAM_R_VA1_I2CADDR, RAM_R_FW_STATUS Routines used ROM_I2C_ST, ROM_I2C_BT, ROM_I2C_LT Unchanged registers Z ROM routine name ROM_I2C_BYTE_RD This routine is used to sequentially read one single byte from the I2C slave device from a given memory address. The device address for the I2C device is taken automatically from I2C slave address of CR_PI_I2C. The routine starts with switching on the HSC and switches it off after transmission. It thus causes a high current consumption and has a long runtime. In power critical applications, its use should thus be restricted. Timing properties of the I2C slave should also be considered. Prerequisite - Input parameters / register values X: 16-bit memory address where the data is read. Output/Return value X: Single data byte, stored in byte B0 of X In case of an error, the transmission was not acknowledged by the I2C slave device and bit BNR_I2C_ABORT of RAM_R_FW_STATUS is set. Temporary RAM - Permanent RAM RAM_R_VA1_I2CADDR, RAM_R_FW_STATUS Routines used ROM_I2C_ST, ROM_I2C_BT, ROM_I2C_LT Unchanged registers Z
15.5.6 Housekeeping
ROM routine name ROM_CPU_CHK Check kind of CPU request: This routine is called by hardware design after any Post Processing (PP) request. It checks the system handling register SHR_CPU_REQ and calls the requested routines. Prerequisite -
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 190 ROM routine name ROM_CPU_CHK Input parameters / register values Flag settings in SHR_CPU_REQ Output/Return value The routine directly calls firmware (MK_CPU_REQ), boot loader (ROM_BLD) or checksum generation (ROM_CSM) using goto. These routines generally return, after execution, to the start of ROM_CPU_CHK to see if SHR_CPU_REQ has changed in the meantime. Temporary RAM (depending on called routines) Permanent RAM (depending on called routines) Routines used MK_CPU_REQ, ROM_BLD, ROM_CSM Unchanged registers (all registers X, Y, Z and R are in use) Call Address 61440 / 0xF000 ROM routine name ROM_USER_RAM_INIT Description This ROM routine is used to initialize the entire user RAM with 0 as default value. Prerequisite - Input parameters / register values - Output/Return value All 176 user RAM cells (addresses 0x00 - 0xAF) are initialized to 0 Temporary RAM All 176 user RAM cells Permanent RAM - Routines used - Unchanged registers Y, Z
15.5.7 High-speed Oscillator
ROM routine name ROM_SCALE_WITH_HSC Routine to scale the input parameter with the HS Clock Calibration factor (RAM_R_HSC_SCALE_FACT) Scaled output = Input / RAM_R_HSC_SCALE_FACT Prerequisite RAM_R_HSC_SCALE_FACT must have the valid HS Clock Calibration factor (Use ROM_HSC_CALIB routine) Inputs X - Parameter to be scaled (any format, integer value < 230) Output X - Scaled parameter (same format as input X) Temporary RAM - Permanent RAM RAM_R_HSC_SCALE_FACT Routines used - Unchanged registers Z ROM routine name ROM_PP_HSC_CALIB
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 191 ROM routine name ROM_PP_HSC_CALIB Input parameters / register values Output/Return value Temporary RAM Permanent RAM Routines used Unchanged registers
15.5.8 Configuration
ROM routine name ROM_RECFG_TOF_RATE Routine to reconfigure TOF_RATE generator for less measurements, depending on the parameter N: New TOF_RATE = Original TOF_RATE * N The actual measurement is done only every Nth time. The routine manipulates SHR_TOF_RATE for this adjustment. It is only usable for TOF_RATES up to 31. Prerequisite - Input parameters / register values X - Factor N for lowering the TOF_RATE Output/Return value Z - Original TOF_RATE value from SHR_TOF_RATE Register TOF_RATE bits in SHR_TOF_RATE Register are changed (see description). Bit BNR_TOF_RATE_REDUCED is set in RAM_R_FW_STATUS register to indicate that the TOF_RATE was reconfigured. Temporary RAM - Permanent RAM RAM_R_FW_STATUS Routines used - Unchanged registers (all registers X, Y ,Z and R are in use)
15.5.9 Mathematics
ROM routine name ROM_FORMAT1_64_TO_32BIT Routine to format a 64-bit value (in Y and X) into a 32 bit result with 16 integer + 16 fractional bits This can be used to format 64 bit multiplication results with 32 integer + 32 fractional bits into a usual fd 16 word. The MSB of the integer part in Y defines the sign, as if Y and X would be a single 64 bit word. This routine has the same function as ROM_FORMAT_64_TO_32BIT, but is essentially faster at the cost of one temporary RAM cell. Prerequisite - Input parameters / register values Y: Higher 32 bits of the value (integer part with maximum 16 significant bits, signed !) X: Lower 32 bits of value (fractional part, unsigned !)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 192 ROM routine name ROM_FORMAT1_64_TO_32BIT Output/Return value X: 32-bit result with 16 Integer + 16 fractional bits (fd 16) Temporary RAM RAM_R_V1F_SHIFT Permanent RAM - Routines used - Unchanged registers Z ROM routine name ROM_DIV_BY_SHIFT Routine to perform the division of a value Y by X, where X=2^N is an integer power of two. Result = Y/X = Y/2^N Prerequisite - Input parameters / register values X - Divisor (denominator) = 2^N value (integer) Y - Dividend (numerator) (any format) Output/Return value Y - Result of division (same format as input Y) Temporary RAM - Permanent RAM - Routines used - Unchanged registers Z, R ROM routine name ROM_SQRT This routine is used to evaluate the square root using the Newton method accurately for values in the range (196 <= X <= 5476). sqrt(x) is calculated by iterating the following steps 1. Choose GUESS = 32; Iteration counter = 3 2. Find x/GUESS (1st division by shift and normal division for next 2 iterations) 3. Average of GUESS and x/GUESS 4. GUESS <--- Average ; Decrement iteration counter 5. Repeat steps 2-4 till counter = 0 6. Square Root = Last GUESS value When used in flow temperature calculation, values of X between 196 = (14^2) and 5476 = (74^2) result in temperature errors < 1°C. This X range is equivalent to a temperature range of 60°C to 0°C. Prerequisite - Input parameters / register values X : Radicand (fd 16, 196 <= X <= 5476) Output/Return value : Square root of input X (fd 16) Temporary RAM RAM_R_V2F_SQRT_X, RAM_R_V2E_SQRT_Y Permanent RAM - Routines used - Unchanged registers (all registers X, Y, Z and R are in use)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 193 ROM routine name ROM_LINEAR_CORRECTION / ROM_LINEAR1_CORRECTION Linear interpolation of a coefficient over any parameter (here: temperature), knowing the coefficient value at two points and given the current value of the parameter (stored in RAM_R_VA3_CURRENT_THETA) Applied formula: Result = slope * (RAM_R_VA3_CURRENT_THETA - Parameter@Point1) + offset = X * (RAM_R_VA3_CURRENT_THETA - Y) + Z When the coefficient value is known at two parameter points, slope and offset can be calculated as slope = (Coefficent@Point2 - Coefficent@Point1) / (Parameter@Point2 - Parameter@Point1) offset = Coefficent@Point1 The routine has an alternative call address ROM_LINEAR1_CORRECTION, where the RAM cell of the current parameter value can be freely chosen. Prerequisite - Input parameters / register values X : Slope between the two points (fd 16) Y: Parameter@Point1 (fd 16) Z: Offset (fd 16) RAM_R_VA3_CURRENT_THETA current parameter (temperature) (fd 16) With alternative call ROM_LINEAR1_CORRECTION: R: Pointer to RAM cell with current parameter value Output/Return value X: Coefficient corrected linearly over temperature Temporary RAM - Permanent RAM RAM_R_VA3_CURRENT_THETA (none when ROM_LINEAR1_CORRECTION is used) Routines used ROM_FORMAT1_64_TO_32BIT Unchanged registers (all registers X,Y,Z and R are in use) ROM routine name ROM_FIND_SLOPE This routine is used to find the slope between two points, given the coefficient and corresponding parameter values at the two points (for example two correction factors over two temperatures). The routine is used as preparation for any linear interpolation. Basically, all input- and output-values have the same format. Due to internal calculations, the format must be chosen such that the four leading bits of the parameters are zero, and at least 12 leading bits of the resulting slope are zero, too. Otherwise the result will be wrong. Prerequisite Parameter interval (RAM_R_VA5_FLOWVAR_1 – Z) must be numerically larger than (Y - X)/23, to avoid overflow in an internal division. Input parameters / register values X : Coefficient at point 1 (any format, typically 16 fd) Y: Coefficient at point 2 (same format as X) Z: Parameter at point 1 (same format as X, 4 leading bits must be 0) RAM_R_VA5_FLOWVAR_1: Parameter at point 2 (same format as Z) Output/Return value X : Slope (same format as input X; 12 leading bits are always 0) Temporary RAM - Permanent RAM RAM_R_VA5_FLOWVAR_1 Routines used - Unchanged registers (all registers X, Y, Z and R are in use)
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 194
15.6 Amplitude Calculation
The raw data of the amplitude measurement and amplitude calibration measurement are stored in the frontend data buffer: FDB_US_AM_U ≡ AMUp[𝑛𝑠] FDB_US_AM_D ≡ AMDown[𝑛𝑠] FDB_US_AMC_VH ≡ 𝐴𝑀𝐶ℎ𝑖𝑔ℎ[𝑛𝑠] FDB_US_AMC_VL ≡ 𝐴𝑀𝐶low [𝑛𝑠] The calibrated amplitudes in Volt are calculated according following formulas: Equation 1: 𝑉𝑈𝑝[𝑚𝑉] = 𝐴𝑀𝐶𝐺𝑟𝑎𝑑𝑖𝑒𝑛𝑡 [𝑚𝑉 𝑛𝑠 ] × 𝐴𝑀𝑈𝑝[𝑛𝑠] − 𝐴𝑀𝐶𝑂𝑓𝑓𝑠𝑒𝑡 [𝑛𝑠 𝑚𝑉 𝑛𝑠 ] 𝑉𝐷𝑜𝑤𝑛[𝑚𝑉] = 𝐴𝑀𝐶𝐺𝑟𝑎𝑑𝑖𝑒𝑛𝑡 [𝑚𝑉 𝑛𝑠 ] × 𝐴𝑀𝐷𝑜𝑤𝑛[𝑛𝑠] − 𝐴𝑀𝐶𝑂𝑓𝑓𝑠𝑒𝑡 [𝑛𝑠 𝑚𝑉 𝑛𝑠 ] With 𝐴𝑀𝐶𝐺𝑟𝑎𝑑𝑖𝑒𝑛𝑡 [𝑚𝑉 𝑛𝑠 ] = 𝑉𝐶𝑎𝑙[𝑚𝑉] 𝐴𝑀𝐶𝐻[𝑛𝑠] − 𝐴𝑀𝐶𝐿[𝑛𝑠] ; 𝑉𝐶𝑎𝑙 = 𝑡𝑦𝑝. 𝑉𝑟𝑒𝑓 2⁄ = 350𝑚𝑉 𝐴𝑀𝐶𝑂𝑓𝑓𝑠𝑒𝑡[𝑚𝑉] = (2 × 𝐴𝑀𝐶𝐿[𝑛𝑠] − 𝐴𝑀𝐶𝐻[𝑛𝑠]) × 𝐴𝑀𝐶𝐺𝑟𝑎𝑑𝑖𝑒𝑛𝑡 [𝑚𝑉 𝑛𝑠 ]
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 195
15.7 FW Handling Procedures
For FW handling, following procedures can be distinguished: [A] Write / Store FW Code & FW Data [B] Write / Store / Lock FW Code & FW Data [C] Erase / Unlock FW Code & FW Data [D] Write / Store FW Data only [E] Verify FW Code & FW Data Figure 171: Firmware handling FW handling procedures needs 3 or 4 phases to be properly performed: Phase 1: Wait time (dependent on start option) Phase 2: Preparation (common for all procedures) Phase 3: FW Update (different for procedures [A], [B], [C], [D] ) Phase 4: FW Retention Check (common for all procedures) Phase 3 is not needed for procedure [E]. START of any FW handling procedure is independent from current status of AS6031: Measure cycle mode can be either in disabled or in enabled state. Preparation START of FW Handling after Power On Write / Store FW Code & FW Data Write / Store / Lock FW Code & FW Data FW Retention Check END of FW Handling Mandatory Wait Time: 80 ms START of FW Handling after System Reset via SPI (0x99) Mandatory Wait Time: 1 ms Write / Store FW Data only Erase / Unlock FW Code & FW Data Phase 1 Phase 2 Phase 3 Phase 4 [A] [B] [C] [D] [E]
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 196 After END of any FW handling procedure the AS6031 is in IDLE state. Then flow meter mode can be triggered by executing a system reset (RC_SYS_RST) or a system init (RC_SYS_INIT). The following recommended FW handling procedures are timer based as well based on interrupt handling.
15.7.1 Phase1: Initial Wait Time
Initial wait time depends on start option:
- Power On
- System Reset via SPI Figure 172: Start with Power On Step Description SPI Opcodes & Data
1 Power On of AS6031
2 Mandatory wait time: At least 80 ms
The wait time after Power On is derived by release of internal power on resets. After this wait time SPI communication is possible with AS6031. Figure 173: Start with System Reset Step Description SPI Opcodes & Data
1 Execute System Reset by sending RC_SYS_RST 0x99
2 Mandatory wait time: At least 1 ms
15.7.2 Phase 2: Preparation
The preparation phase is common for all procedures and sets device in a stable idle state before starting a FW update. Figure 174: Preparation Step Description SPI Opcodes & Data
1 Request Bus Master 0x88
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 197 Step Description SPI Opcodes & Data
2 Disable Watchdog by writing code to CR_WD_DIS 0x5A 0xC0
3 Set RESTART_EN by writing code to CR_TRIM2
Sets also recommended CPU_SPEED 0x5A 0xCD 0x40100000 Disable BG, & Post Processing settings and set Measure Cycle Time to max. value by writing code to CR_MR_TS 0x5A 0xC6 0x00001000
5 Execute Supervisor Init by sending RC_SV_INIT
Clears task sequencer and sets MCT = OFF 0x9C
6 Mandatory wait time: At least 1 ms
7 Request Dummy Measurement Task
To clear pending HCC/ZCC calibration due to SV_INIT 0xDA 0x00
8 Mandatory wait time: At least 1 ms
9 Clear Interrupt, Error & FEP Status Flag by writing to
SHR_EXC 0x5A 0xDD 0x00000007
10 Execute Reset Flag Clear in SYS_STATUS by sending
RC_RF_CLR 0x89 Enable important interrupt & error flags in CR_IEH[19,17,15,14,13,12] for following FW transactions 0x5A 0xC4 0x000AF000
12 Release Bus Master 0x87
13 Perform Recall of Firmware Data via
FWD_RECALL (bit 20) in SHR_RC See subroutine “Perform FW Transaction”
14 Perform Recall of Firmware Code via
FWC_RECALL (bit 19) in SHR_RC See subroutine “Perform FW Transaction” IDLE state reached & Ready for FW Update Remarks:
- Step 14 Can be skipped if FW update [D] (Write / Store of FW Data only) is performed subsequently
15.7.3 Phase 3: FW Update
To fulfill specified NVRAM parameters “Data Retention” and “Endurance”, Vcc supply has to be in the range of 3.0 – 3.6 V when FW is updated. [A]: Write / Store FW Code & FW Data [B]: Write / Store / Lock FW Code & FW Data
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 198 Figure 175: [A] or [B]: Write / Store / (Lock) FW Code & FW Data only Step Description SPI Opcodes & Data
1 Get range of FW user code by reading SRR_FWU_RNG 0x7A 0xEC
read data (Bit [31:0]) Write Firmware Code User FWCU to FWC addresses 32….[FWU_RNG-1] 0x5C 0x00 0x20 0xXX 0xXX …..
3 Write Firmware Data User FWDU to FWD addresses
2….119 0x5B 0x02 0xXXXXXXXX 0xXXXXXXXX ……. After calculation: Write expected checksums for FWCU & FWDU to FWD addresses 0….1: FWCU_CS_EXP, FWDU_CS_EXP 0x5B 0x00 0xXXXXXXXX 0xXXXXXXXX [A]: Write / Store FW Code & FW Data Perform Store of Firmware Code & Data via FW_STORE_ALL (bit 16) in SHR_RC See subroutine “Perform FW Transaction” [B]: Write / Store / Lock FW Code & FW Data Perform Store of Firmware Code & Data with Lock via FW_STORE_LOCK (bit 17) in SHR_RC See subroutine “Perform FW Transaction” Remarks:
- Step 1 & 2 Writing FW Code up to [FWU_RNG-1] is not required in any case. For a one-time customer update (e.g. in production flow), the Firmware Code can be written up to last address of customer code only, as user area is filled with 0x00 up to [FWU_RNG-1] when delivered to customer.
- Step 4 Writing checksums separately facilitates the generation of checksums before in steps 2 & 3 while code and data are transferred. If checksums are generated before transferring of code and data, steps 3 & 4 can be combined to 1 block transfer: 0x5B 0x00 0xXXXXXXXX 0xXXXXXXXX ………..
- Step 5 This step is the only difference between FW update [A] and [B]. All steps before are common.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 199 Figure 176: [C]: Erase / Unlock FW Code & FW Data Step Description SPI Opcodes & Data
1 Perform Erase of Firmware Code & Data via
FW_ERASE (bit 18) in SHR_RC See subroutine “Perform FW Transaction” Figure 177: [D]: Write / Store FW Data only Step Description SPI Opcodes & Data
1 Write Firmware Data User FWDU to FWD addresses
2….119 0x5B 0x02 0xXXXXXXXX 0xXXXXXXXX ……. After calculation: Write expected checksum for FWDU to FWD address 1: FWDU_CS_EXP 0x5B 0x01 0xXXXXXXXX
3 Perform Store of Firmware Data via
FWD_STORE (bit 22) in SHR_RC See subroutine “Perform FW Transaction” Remarks: The previous recommended sequences for [A] – [D] allow minimum write access times by addressing user parts only (FWCU & FWDU). Alternatively, whole memory space can be addressed without any effect on applied FW sections (FWCA & FWDA)
15.7.4 Phase 4: FW Retention Check
Figure 178: FW retention check Step Description SPI Opcodes & Data
1 Perform Recall of Firmware Code via
FWC_RECALL (bit 19) in SHR_RC See subroutine “Perform FW Transaction”
2 Perform Recall of Firmware Data via
FWD_RECALL (bit 20) in SHR_RC See subroutine “Perform FW Transaction”
3 Initialize checksum error flags in SHR_GPO
SHR_GPO[18:12] == b1111111 0x5A 0xD3 0x0007F000
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 200 Step Description SPI Opcodes & Data
4 Execute Checksum Generation by sending
RC_FW_CHKSUM 0xB8
5 Check that FW checksum has been finished by reading
CHKSUM_FNS (bit 3) in SRR_IRQ_FLAG See subroutine “Interrupt Handling” Retention check by reading SHR_GPO PASS: SHR_GPO[18:12] == b0000000 FAIL: SHR_GPO[18:12] != b0000000 0x7A 0xD3 read data (Bit [31:0]) Remarks: ▪ Steps 1 & 2 Can be skipped if FW procedure [E] (Verify of FW Code & Data) is performed (no FW update before)
15.7.5 Common Subroutines
Figure 179: Interrupt handling Step Description SPI Opcodes & Data a Wait on interrupt INTN b Check interrupt flag on reading SRR_IRQ_FLAG(bit x) 0: not needed 1: FW_TRANS_FNS 2: not needed 3: CHKSUM_FNS 4-7: not needed 0x7A 0xE0 read data (Bit x of 32) c Clear interrupt flag register by sending RC_IF_CLR 0x8D Interrupt Handling requires that appropriate interrupt flag in CR_IEH is enabled in advance. Figure 180: Preform firmware transaction Step Description SPI Opcodes & Data a Enable FW Transaction by writing release code to SHR_RC_RLS 0x5A 0xDF 0x50F5B8CA
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 201 Step Description SPI Opcodes & Data b Execute FW Transaction by writing code to SHR_RC(bit x) 16: FW Store All 17: FW Store & Lock 18: FW Erase & Unlock 19: FW Code Recall 20: FW Data Recall 21: not needed 22: FW Data Store 0x5A 0xDE write data (Bit x of 32) c Check that FW transaction has been finished by reading FW_TRANS_FNS (bit 1) in SRR_IRQ_FLAG See subroutine “Interrupt Handling”
15.7.6 Optional Status Check
Figure 181: Preform optional status check Step Description SPI Opcodes & Data Prepare & perform short bootload sequence for updating FW revisions by writing code to CR_TRIM3, FWD_ACR, SHR_CPU_REQ 0x5A 0xCE 0x00000000 0x5B 0x6B 0x00000000 0x5A 0xDC 0x00000001 Get FW Range, FWU Revision, FWA Revision by reading SRR_FWU_RNG, SRR_FWU_REV, SRR_FWA_REV 0x7A 0xEC read data (Bit [31:0]) read data (Bit [31:0]) read data (Bit [31:0]) Check status of Watchdog and Lock State by reading SRR_MSC_STF: Bit 15: Watchdog State Bit 2: Lock State 0x7A 0xEA read data (Bit [31:0]) Check different status bits by reading System Status Bit 7: Error Flag Bit 5: Communication Fail Bit 4: Measure Cycle Timer State 0x8F read data (Bit [7:0]) Remarks:
- Steps 1 & 2 are mandatory for step 3
- Steps 4 & 5 can be performed separately
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 202
15.8 Measurement Start in Time Conversion Mode
A measurement start in time conversion mode typically requires that “Autoconfig Release Code” is disabled. Further interactions via remote interface have to be performed as follows (greyed actions as described above in flow diagram): Figure 182: Measurement Start Step Description Opcodes & Data
1 Wait on interrupt INTN
2 Check interrupt flag on reading SRR_IRQ_FLAG(bit 2)
2: BLD_FNS 0x7A 0xE0 read data (Bit 2 of 32)
3 Clear interrupt flag register by sending RC_IF_CLR 0x8D
Write Configuration Data to CR addresses: 0x0C0….0x0CB SHR addresses: 0x0D0…0x0D2 / 0x0DA…0x0DB 0x5A 0xC0 0xXXXXXXXX ……. 0x5A 0xD0 0xXXXXXXXX …….
5 Set Measure Cycle Timer On 0x8B
6 Check if Cycle Timer is on with RC_RD_STATUS, bit 4
MCT_STATE 0x8F read byte
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 203
16 Known Errors
16.1 Amplitude Measurement
- Description: AM measurement gets corrupted or fails completely at extreme operating parameters.
- Workaround: 4 actions needed: Figure 183: Workaround Actions HW implementation on PCB: GIPO4 connected to GPIO1 GPIO4 CR_GP_CTRL[19:16] b0100 GPIO1 CR_GP_CTRL[7:4] b1111 TI_EN_MODE CR_TRIM3[19] b1
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 204 Document Status Product Status Definition Product Preview Pre- Development Information in this datasheet is based on product ideas in the planning phase of development. All specifications are design goals without any warranty and are subject to change without notice Preliminary Datasheet Pre- Production Information in this datasheet is based on products in the design, validation or qualification phase of development. The performance and parameters shown in this document are preliminary without any warranty and are subject to change without notice Datasheet Production Information in this datasheet is based on products in ramp-up to full production or full production which conform to specifications in accordance with the terms of ScioSense B.V. standard warranty as given in the General Terms of Trade Datasheet (discontinued) Discontinued Information in this datasheet is based on products which conform to specifications in accordance with the terms of ScioSense B.V. standard warranty as given in the General Terms of Trade, but these products have been superseded and should not be used for new designs Changes from previous version to current revision v1-00 Page First officially released datasheet all
- Page and figure numbers for the previous version may differ from page and figure numbers in the current revision.
- Correction of typographical errors is not explicitly mentioned.
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 205
18 Legal Information
Copyrights & Disclaimer Copyright ScioSense B.V., High Tech Campus 10, 5656 AE Eindhoven, The Netherlands. Trademarks Registered. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. Devices sold by ScioSense B.V. are covered by the warranty and patent indemnification provisions appearing in its General Terms of Trade. ScioSense B.V. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein. ScioSense B.V. reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with ScioSense B.V. for current information. This product is intended for use in commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are specifically not recommended without additional IS” and any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are disclaimed. ScioSense B.V. shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of ScioSense B.V. rendering of technical or other services. RoHS Compliant & ScioSense Green Statement RoHS Compliant: The term RoHS compliant means that ScioSense B.V. products fully comply with current RoHS directives. Our semiconductor products do not contain any chemicals for all 6 substance categories, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, RoHS compliant products are suitable for use in specified lead-free processes. ScioSense Green (RoHS compliant and no Sb/Br): ScioSense Green defines that in addition to RoHS compliance, our products are free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material). Important Information: The information provided in this statement represents ScioSense B.V. knowledge and belief as of the date that it is provided. ScioSense B.V. bases its knowledge and belief on information provided by third parties and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. ScioSense B.V. has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming
Datasheet • PUBLIC DS000587 • v1-00 • 2020-May-06 206 │ 206 to be proprietary, and thus CAS numbers and other limited information may not be available for release.