Datasheet sections

  • 1 General Description
  • 2 Key Features
  • 3 Applications
  • 4 Pin Assignments
  • 4.1 Pin Descriptions
  • 5 Absolute Maximum Ratings
  • 6 Electrical Characteristics
  • 6.1 DC Characteristics for Digital Inputs and Outputs
  • 6.1.1 CMOS Input: ADR
  • 6.1.2 CMOS I²C: SDA, SCL
  • 6.2 Electrical and Magnetic Specifications
  • 7 Detailed Description
  • 7.1 Typical Application
  • 7.2 I²C Interface
  • 7.2.1 I²C Interface Data
  • 7.3 I²C Modes
  • 7.4 SDA, SCL Input Filters
  • 7.5 Register Map and Description
  • 8 Package Drawings and Markings
  • 8.2 Package Dimensions
  • 8.3 Recommended Footprint
  • 9 Ordering Information

www.ams.com high performance needs great design. Datasheet : AS5510 Linear Hall Sensor with I²C Output Please be patient while we update our brand image as austriamicrosystems and TAOS are now ams.

1 General Description

for an ambient temperature range from -30°C to +85°C.

2 Key Features

3 Applications

Closed loop position control. Figure 1. Linear Position Sensor with AS5510 + Magnet Figure 2. Block Diagram

4 Pin Assignments

Figure 3. Pin Configuration of AS5510 (Top view) Note: The AS5510 is available in a 6-pin Chip Scale Package with a ball pitch of 400μm.

4.1 Pin Descriptions

Table 1. Pin Description

5 Absolute Maximum Ratings

maximum rating conditions for extended periods may affect device reliability. Table 2. Absolute Maximum Ratings

6 Electrical Characteristics

6.1 DC Characteristics for Di gital Inputs and Outputs

6.1.1 CMOS Input: ADR

Note: Operating conditions: Tamb = -30°C to +85°C, VDD = 2.5V to 3.6V (3V operation) unless otherwise noted.

6.1.2 CMOS I²C: SDA, SCL

Table 3. Operating Conditions Table 4. Electrical Characteristics ADR Input Table 5. Electrical Characteristics I²C

  1. In Fast-mode Plus, fall time is specified the same for both output stage and bus timing. If series resistors are used this has to be consid-
  2. Input filters on the SDA and SCL inputs suppress noise spikes of less than 50 ns.
  3. I/O pins of Fast-mode and Fast-mode plus devices must not obstruct the SDA and SCL lines if VDD is switched off.
  4. Special purpose devices such as multiplexers and switches may exceed this capacitance due to the fact that they connect multiple

Note: Operating conditions: Tamb = -30°C to +85°C, VDD = 2.5V to 3.6V (3V operation) unless otherwise noted.

6.2 Electrical and Magnetic Specifications

Table 6. Electrical and Magnetic Specifications

  1. Offset inp = 0.35mT residual offset + 0.1mT earth magnetic field.
  2. This time is needed for the first power-up of the device until the offset compensation is finished; Includes readout of the PPROM fuses;

It depends on the sensitivity setting.

  1. Time after switching from power-down mode into active mode until the offset compensation is finished.

50 KHz

  1. Input related Noise (Noise Inp) is the repeatability of the measurement.

12.5 KHz

7 Detailed Description

7.1 Typical Application

Figure 4. Typical Application

7.2 I²C Interface

The AS5510 includes an I²C slave according to the NXP specification UM10204.

7.2.1 I²C Interface Data

Note: Operating conditions Tamb = -30 to +85°C, VDD=2.5 to 3.6V (3V operation) unless otherwise noted. Table 7. I²C Timings

  1. After this time the first clock is generated
  2. A device must internally provide a hold time of at least 120ns (Fast-mode Plus) for the SDA signal (referred to the VIHmin of the SCL) to

bridge the undefined region of the falling edge of SCL.

  1. A fast-mode device can be used in standard-mode system, but the requirement tSU.DAT = 250ns must then be met. This is automatically

nal, it must output the next data bit to the SDA line tRmax + TSU.DAT = 1000 + 250 = 1250ns before the SCL line is released.

  1. In Fast-mode Plus, fall time is specified the same for both output stage and bus timing. If series resistors are used this has to be consid-

Figure 5. I²C Timing Diagram

7.3 I²C Modes

to the bus are made through the open-drain I/O lines SDA and the input SCL. Clock stretching is not included. Data transfer may be initiated only when the bus is not busy. are interpreted as start or stop signals. Bus Not Busy. Both data and clock lines remain HIGH. Start Data Transfer. A change in the state of the data line, from HIGH to LOW, while the clock is HIGH, defines a START condition. Stop Data Transfer. A change in the state of the data line, from LOW to HIGH, while the clock line is HIGH, defines the STOP condition. each receiver acknowledges with a ninth bit. enable the master to generate the STOP condition.

Figure 9. Data Read (Write Pointer, Then Read) - Slave Receive and Transmit Automatic increment of address pointer. The AS5510 slave automatically increments the address pointer after each byte transferred. The increase of the address pointer is independent from the address being valid or not. write cycle is possible. The address pointer is increased after each byte. read over the whole address range is possible including address overflow.

7.4 SDA, SCL Input Filters

than tHD.STA 260ns. For Standard-mode and Fast-mode an internal hold time of 300ns is required, which is not covered by the AS5510 slave.

7.5 Register Map and Description

Table 8. Register Map

Table 9. Register Description 03h, 04h Offs9 to Offs0 10 Bit value of the offset compensation.

8 Package Drawings and Markings

Figure 10. 6-Pin WL-CSP 1.4 x 1.1mm

8.2 Package Dimensions

Figure 11. Package Dimensions

8.3 Recommended Footprint

Figure 12. Recommended Footprint

www.ams.com/AS5510 Revision 0.1 16 - 18 AS5510 Datasheet - Revision History

Revision History

Note: Typos may not be explicitly mentioned under revision history. Revision Date Owner Description 0.1 27 Jan, 2012 rph Initial revision

9 Ordering Information

The devices are available as the standard products shown in Table 10. Note: All products are RoHS compliant and ams green. Table 10. Ordering Information

www.ams.com/AS5510 Revision 0.1 18 - 18 AS5510 Datasheet - Copyrights Copyrights Copyright © 1997-2012, ams AG, Tobelbaderstrasse 30, 8141 Unterpremstaetten, Austria-Europe. Trademarks Registered ®. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. All products and companies mentioned are trademarks or registered trademarks of their respective companies. Disclaimer Devices sold by ams AG are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. ams AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. ams AG reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with ams AG for current information. This product is intended for use in normal commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are specifically not recommended without additional processing by ams AG for each application. For shipments of less than 100 parts the manufacturing flow might show deviations from the standard production flow, such as test flow or test location. The information furnished here by ams AG is believed to be correct and accurate. However, ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of ams AG rendering of technical or other services. Contact Information Headquarters ams AG Tobelbaderstrasse 30 A-8141 Unterpremstaetten, Austria Tel : +43 (0) 3136 500 0 Fax : +43 (0) 3136 525 01 For Sales Offices, Distributors and Representatives, please visit: http://www.ams.com/contact