AMB120-3 BELIMO | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Power Supply 100...240 VAC, ±10%, 50/60 Hz, 24 VDC, Power consumption in operation 2.5 W Power consumption in rest position 0.5 W Transformer sizing 5.5 VA (class 2 power source) Shaft Diameter 1/2...1.05” round, centers on 1/2” and 3/4” with insert, 1.05” without insert Electrical Connection 18 GA plenum cable, 3 ft [1 m], with 1/2” conduit connector, degree of protection NEMA 2 / IP54 Overload Protection electronic throughout 0...95° rotation Input Impedance 600 Ω Angle of rotation Max. 95°, adjustable with mechanical stop Torque motor 180 in-lb [20 Nm] Direction of motion motor selectable with switch 0/1 Position indication Mechanically, 30...65 mm stroke Manual override external push button Running Time (Motor) 95 s, constant, independent of load Ambient humidity max. 95% r.H., non-condensing Degree of Protection IP54, NEMA 2, UL Enclosure Type 2 Housing material UL94-5VA Agency Listing cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2014/30/EU and 2014/35/EU Noise level, motor 45 dB(A) Servicing maintenance-free Quality Standard ISO 9001 Weight 1.1 lb [1.0 kg] †Rated Impulse Voltage 800V, Type action 1.B, Control Pollution Degree 3. Torque min. 180 in-lb, for control of damper surfaces up to 45 sq. ft. Application For on/off and floating point control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp, self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The actuator provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The actuators use a sensorless brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. The -S version is provided with 1 built-in auxiliary switch. This SPDT switch is provided for safety interfacing or signaling, for example, for fan start-up. The switching function is adjustable 0 to 95°. The auxiliary switch is double insulated so an electrical ground connection is not necessary. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches[mm]) 5.47” [139] 4.06” [103] 2.2” [56] 2.49” [63.4] 4.3” [109] 1.18” [30] 3.46” [88] 2” [50.8] To center of mounting slot. AMB120-3 Technical Data Sheet On/Off, Floating Point, Non-Spring Return, AC 100...240 V 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/10/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.

K-SA Shaft clamp reversible ZG-100 Univ. right angle bracket 17”x11-1/8”x6” (HxWxbase). ZG-101 Univ. right angle bracket 13x11x7-7/16” (HxWxbase). ZG-103 Univ. right angle bracket 7-1/2x11x2-3/4” (HxWxbase). ZG-104 Univ. right angle bracket 13-5/8x7-1/2x4” (HxWxbase). ZG-NMA Mounting kit for linkage operation AV8-25 Shaft extension ZG-JSA-1 1” diameter jackshaft adaptor (11” L). ZS-T Terminal-strip cover for NEMA 2 rating (-T models). ZS-100 Weather shield - galvaneal 13x8x6” (LxWxD). ZS-150 Weather shield - PC w/ foam seal 16x8-3/8x4” (LxWxD). ZS-260 Explosion proof housing. ZS-300 NEMA 4X, 304 stainless steel enclosure. TOOL-06 8 mm and 10 mm wrench. PS-100 Low voltage and control signal simulator. S1A Auxiliary switch for damper actuators and rotary actuators S2A Auxiliary switch for damper actuators and rotary actuators P1000A GR Feedback potentiometer for damper actuators and rotary actuators Typical Specification Floating point, on/off control damper actuators shall be electronic direct- coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. If required, actuators shall be provided with one adjustable SPDT auxiliary switch. Actuators with auxiliary switches must be constructed to meet the requirements for double insulation so an electrical ground is not required to meet agency listings. If required, actuators will be provided with a screw terminal strip for electrical connections (AMX24-3-T). Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Wiring Diagrams A Actuators with appliance cables are numbered. Provide overload protection and disconnect as required. Actuators may be connected in parallel if not mechanically linked. Power consumption and input impedance must be observed. Blu (1) Common Brn (2) Load Wht (3) Load N L Line Wht Volts Blk A 1 11 On/Off 100 to 240 VAC Blu (1) Common Brn (2) Load Wht (3) Load Wht N Blk L Line Volts A 1 11 Floating Point 100 to 240 VAC AMB120-3 Technical Data Sheet On/Off, Floating Point, Non-Spring Return, AC 100...240 V 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/10/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.