LF24US BELIMO | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Power Supply 24 VAC, ±20%, 50/60 Hz, 24 VDC, ±10% Power consumption in operation 5 W Power consumption in rest position 2.5 W Transformer sizing 7 VA (class 2 power source) Shaft Diameter 3/8...1/2” round, centers on 1/2” Electrical Connection 18 GA appliance cable, 3 ft [1 m], with 1/2” conduit connector Overload Protection electronic throughout 0...95° rotation Electrical Protection actuators are double insulated Angle of rotation Max. 95°, Torque motor 35 in-lb [4 Nm] Direction of motion motor selectable with switch 0/1 Direction of motion fail-safe reversible with cw/ccw mounting Position indication Mechanical Running Time (Motor) 75 s -22°F [-30°C] Ambient humidity max. 95% r.H., non-condensing Degree of Protection IP54, NEMA 2 Housing material galvanized steel Agency Listing cULus acc. To UL 873 and CAN/CSA C22.2 No. 24-93 Noise level, motor 50 dB(A) Noise level, fail-safe 62 dB(A) Servicing maintenance-free Quality Standard ISO 9001 Weight 3.2 lb [1.5 kg] †Rated Impulse Voltage 800V, Type of action 1.AA, Control Pollution Degree 3 Torque min. 35 in-lb, for control of air dampers. Application For On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. Control is On/Off from an auxiliary contact or a manual switch. The actuator is mounted directly to a damper shaft from 3/8” up to 1/2” in diameter by means of its universal clamp, 1/2” shaft centered at delivery. For shafts up to 3/4” use K6-1 accessory. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The LF series actuators provide true spring return operation for reliable fail-safe application and positive close off on air tight dampers. The spring return system provides consistent torque to the damper with, and without, power applied to the actuator. The LF series provides 95° of rotation and is provided with a graduated position indicator showing 0° to 95°. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. Power consumption is reduced in holding mode. The actuator is double insulated so an electrical ground connection is not necessary. Dimensions (Inches[mm]) 2.74" [69.6] 2.25" [57.1] 0.73" [18.54] 3.23" [82] 0.25" [6.25] 1.15" [29.3] 2.3" [58.42] 3.15" [80] 7.66" [194.501] 0.2" [5.08] 0.97" [24.6] 3.86" [98] 6.1" [155] 3.66" [93] 6.1" [155] 0.26" [6.5] LF24 US Technical Data Sheet On/Off, Spring Return, AC/DC 24 V 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/10/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.
K6 US Standard LF clamp (3/8” to 1/2”). K6-1 Shaft clamp reversible KG10A Ball joint KG8 Ball joint KH8 Damper crank arm KH-LF Actuator arm KH-LFV V-bolt Kit for KH-LF. LF-P Anti-rotation bracket LF. SH10 Push rod for KG10A ball joint (36” L, 3/8” diameter). SH8 Push rod for KG6 & KG8 ball joints (36” L, 5/16” diameter). TOOL-06 8 mm and 10 mm wrench. ZDB-LF Angle of rotation limiter ZF8-LF Form fit adapter ZG-109 Right angle bracket for ZS-260. ZG-110 Stand-off bracket for ZS-260. ZG-112 LF right angle bracket 4-1/2x5-1/2x2-1/2” (HxWxD). ZG-DC1 Damper clip for damper blade, 3.5” width. ZG-DC2 Damper clip for damper blade, 6” width. ZG-LF112 LF crankarm adaptor kit (includes ZG-112). ZG-LF2 LF crankarm adaptor kit (T bracket included). ZG-LMSA-1 Shaft extension for 3/8” diameter shafts (4” L). ZG-LMSA-1/2-5 Shaft extension for 1/2” diameter shafts (5” L). ZS-100 Weather shield - galvaneal 13x8x6” (LxWxD). ZS-101 Base plate for ZS-100. ZS-150 Weather shield - PC w/ foam seal 16x8-3/8x4” (LxWxD). ZS-260 Explosion proof housing. ZS-300 NEMA 4X, 304 stainless steel enclosure. ZS-300-5 NEMA 4X, 316L stainless steel enclosure. ZS-300-C1 1/2” shaft adaptor, standard wtih ZS-300(-5). ZS-300-C2 3/4” shaft adaptor for ZS-300(-5). ZS-300-C3 1” shaft adaptor for ZS-300(-5). P475 Shaft mount, non-Mercury aux. switch for 1/2” dia. shafts. P475-1 Shaft mount, non-Mercury aux. switch for 1” dia. shafts. PS-100 Low voltage and control signal simulator. ZG-X40 120 to 24 VAC, 40 VA transformer. Typical Specification On/Off spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a shaft up to a 3/4” diameter and center on a 1/2” shaft (default). Actuator shall deliver a minimum output torque of 35 in-lbs. The actuator must be designed so that they may be used for either clockwise or counter clockwise failsafe operation. Actuators shall be protected from overload at all angles of rotation. If required, one SPDT auxiliary switch shall be provided with one switch having the capability of being adjustable. Actuators with auxiliary switch must be constructed to meet the requirement for Double Insulation so an electrical ground connection is not required to meet agency listings. Actuators shall be cULus listed, have a 5 year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Blk (1) Common Wht (2) + Hot Line Volts 1 3 1124 VAC Transformer A On/Off LF24 US Technical Data Sheet On/Off, Spring Return, AC/DC 24 V 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/10/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.
! WARNING! LIVE ELECTRICAL COMPONENTS! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Meets cULus requirements without the need of an electrical ground connection. A Actuators with appliance cables are numbered. Provide overload protection and disconnect as required. Actuators may also be powered by 24 VDC. Actuators may be connected in parallel if not mechanically linked. Power consumption and input impedance must be observed. LF24 US Technical Data Sheet On/Off, Spring Return, AC/DC 24 V 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/10/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.