Features

  • Outside mounting tabs
  • Telescoping sampling tube*
  • Built-in reset button
  • Easy to clean
  • 12/24 VDC operation
  • Ion or photo models available
  • Remote test station option
  • Air velocity rating from 500 to 4000 FPM
  • Remote annunciator option
  • Easy and quick mounting to round or rectangular ducts from 1′–12′ wide
  • Textured cover for convenient visual inspection
  • UL 268A listed
  • 3-year warranty System Sensor DH100 2-wire duct smoke detector is available as either an ionization or photoelectric model. This new design allows for simplified cleaning and maintenance, or a change in application without removing the duct housing. The DH100 samples air currents passing through a duct and gives dependable performance for management of fans, blowers, and air conditioning systems, preventing the spread of toxic smoke and fire gases through the protected area. WARNING: Duct smoke detectors have specific limitations. DUCT DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building’s regular fire detection system. Refer to NFPA 72 and 90A for additional duct detector application information. Specifications Length: 14 3/8 inches (37 cm.) Width: 5 1/2 inches (14 cm.) Depth: 2 3/4 inches (7 cm.) Shipping Weight: 3.75 lbs. (1.7 kg.) Operating Temperature Range: 23 ° to 131° F (–5° to 55° C) Operating Humidity Range: 10% to 93% relative humidity Air Duct Velocity: 500 to 4000 ft./min. *Patent pending

System Voltage: 12/24 VDC Ripple Voltage: 4 Volts peak to peak Start-up Capacitance: 0.02 µF maximum Standby Ratings: 8.5 VDC minimum

35 VDC maximum

µA maximum Alarm Ratings: 4.2 VDC minimum at 10mA

6.6 VDC maximum at 100mA

Alarm current must be limited to 100mA or less by the control panel. If used, the RA400Z remote lamp operates within the specified alarm currents. Reset Voltage: 2.50 VDC minimum Reset Time: 0.3 Sec. maximum Start-up Time: 34.0 Sec. maximum Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor Model DH100 Series Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The detector shall operate at air velocities of 500 feet per minute to 4000 feet per minute. It shall be capable of local testing via magnetic switch or remote testing using the RTS451KEY Remote Test Station. The unit shall be reset by local reset button or RTS451KEY. The duct detector housing shall incorporate an airtight smoke chamber in compliance with UL 268A, Standard for Smoke Detectors for Duct Applications. The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and residue effects on detector and housing, thereby reducing maintenance and servicing. Sampling tubes shall either be telescoping or be easily installed after the housing is mounted to the duct by passing through the duct housing. The enlosure shall meet all applicable NEC and NFPA standards regarding electrical junction boxes. Terminal connections shall be of the strip and clamp method suitable for 12-18 A WG wiring.

(+) IN (+) OUT (+) (+) (–) (–) IN (–) OUT 1ST DETECTOR IN LOOP DH100 (–) RA400Z (OPTIONAL) REMOTE ALARM LED 2.8 VDC NOM. IN ALARM SUPERVISORY SWITCH (+) IN (+) OUT (+) (+) (–) (–) IN (–) OUT LAST DETECTOR IN LOOP DH100 (–) RA400Z (OPTIONAL) REMOTE ALARM LED 2.8 VDC NOM. IN ALARM E O L R STYLE D OPTIONAL WIRING UL LISTED COMPATIBLE 2-WIRE CONTROL PANEL ALARM INITIATION LOOP (+) (–) EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER Wiring diagram for RTS451/RTS451KEY Remote Test Station to 2-wire duct detectors System wiring diagram for 2-wire duct detectors (detectors powered from initiating circuit) 5Test + Test / Reset – Reset + Test ResetRA + RA – V Out + V In + V In / V Out – V In + V In / V Out – DH100 RTS451 KEY

1 Alarm

System Sensor Worldwide Manufacturing & DistributionSystem Sensor Worldwide Manufacturing & Distribution In Canada: Telephone: 905-812-0767 Fax: 905-812-0771 In China: Telephone: 852-2191-9003 Fax: 852-2736-6580 In the Far East: Telephone: 852-2191-9003 Fax: 852-2736-6580 In India: Telefax: 91-022-8202564 In Italy: Telephone: 39-40-9490-111 Fax: 39-40-382137 In Singapore: Telephone: 65-273-2230 Fax: 65-273-2610 In the United Kingdom: Telephone: 44-1403-276500 Fax: 44-1403-276501

Ordering Information

Part No. Description DH100I 2-wire ionization duct detector DH100P 2-wire photoelectronic duct detector A5052-00 Replacement ionization sensor board A5069-00 Replacement photoelectronic sensor board A5061-00 2-wire power board Accessories ST-1.5 Metal sampling tube duct widths 1 ′–2′ ST-3 Metal sampling tube duct widths 2 ′–4′ ST-5 Metal sampling tube duct widths 4 ′–8′ ST-10 Metal sampling tube duct widths 8 ′–12′ T80-71-00 Telescoping sampling tube P48-55-00 End cap for T80-71-00 RTS451KEY Remote test station with key lock RTS451 Remote test station RA400Z Remote annunciator alarm LED APA451 Remote annunciator with piezo alarm MOD400R Sensitivity test module F36-09-00 Replacement air filters (two per package) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes S08-39-01 Photo replacement screen PA400B Mini-Alert sounder PS24LOB Mini-Alert add-on strobe PS12/24LENSC Ceiling-mount “SMOKE” lens PS12/24LENSW Wall-mount “SMOKE” lens RA400Z Remote Annunciator (UL S2522) RTS451 Remote Test Station (UL S2522) ALARM RESET PA400 with PS24LOW Add-on Strobe (PS12/24LENSW smoke lens option available) (UL S3593) F I R E RTS451KEY Remote Test Station with Key (UL S2522) ALARM ON RESET TEST APA451 Piezo Annunciator (UL S401 1) ALARM POWER Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations, and several different means of visible and audible system annunciation. As with our duct detectors, all duct detector accessories are UL listed.