(Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 10 15 20 25 305 110 100 13.2 V 12 V 6 V (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.30 0.25 0.20 0.15 0.10 0.05 0 10 15 20 25 30 355 13.8 V 12 V 6 V (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.20 0.25 0.15 0.10 0.05 0 10 15 20 255 13.8 V 12 V 6 V DC CATALOG No. C1097B001 '20.1 .IT DC Fan 60 mm sq. Static pressure Static pressure Static pressure Airflow Airflow Airflow Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 9A0612G401 With pulse sensor 9A0612S401 With pulse sensor 9A0612H401 With pulse sensor DC Fan 60×60×25 mm San Cooler 60 9A type ■ ■General Specifications
- Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
- Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only.
- Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573.
- Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
- Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
- Sound pressure level (SPL) …………… At 1 m away from the air inlet
- Storage temperature …………………… -30 to +70˚C (Non-condensing) ■ ■Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life [V] [V] [A] [W] [min-1] [m3/min] [CFM] [Pa] [inchH 2O] [dB (A)] [˚C] [h] 9A0612G401 (53000/40˚C) 9A0612S401 6 to 13.8 -20 to +70 40000/60˚C (70000/40˚C) 9A0624G401 24 12 to 27.6 (53000/40˚C) -20 to +70 40000/60˚C (70000/40˚C) The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 597 to 598. Lock sensor PWM control The mark indicates Short Lead Time Service applicable models. See p. 626 for details.
(Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 10 15 20 25 305 120 110 100 12 V 24 V 27.6 V (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.30 0.25 0.20 0.15 0.10 0.05 0 10 15 20 25 30 355 27.6 V 24 V 12 V (inch H2O) (CFM) (m3/min) 静圧 風量 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 10 15 205 13.8 V 12 V 6 V (Pa) (inch H2O) (CFM) (m3/min) 静圧 風量 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 10 15 205 27.6 V 24 V 12 V (Pa) (inch H2O) (CFM) (m3/min) 静圧 風量 0.12 0.10 0.08 0.06 0.04 0.02 0 10 15 205 0 0.1 0.3 0.40.2 0.5 13.8 V 12 V 7 V (Pa) (inch H2O) (CFM) (m3/min) 静圧 風量 0.12 0.10 0.08 0.06 0.04 0.02 0 10 15 205 0 0.1 0.3 0.40.2 0.5 27.6 V 24 V 14 V (Pa) (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.20 0.25 0.15 0.10 0.05 0 10 15 20 255 27.6 V 24 V 12 V CATALOG No. C1097B001 '20.1 .IT DC DC Fan 60 mm sq. Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Airflow Airflow Airflow Airflow Airflow Airflow Airflow Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 9A0612F401 With pulse sensor 9A0612M401 With pulse sensor 9A0624G401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range Operating voltage range 9A0624S401 With pulse sensor 9A0624H401 With pulse sensor 9A0624F401 With pulse sensor 9A0624M401 With pulse sensor
50±0.3 25±0.5 (3) (3) (10) 50±0.3 リード線 AWG24 UL 1007 回転方向 風吹出方向 4-ø4.3±0.3 60 0 60 0 +50 300 0 取付用穴 62.7 50±0.3 29.7 29.7 50±0.3 4-ø4.5 DC CATALOG No. C1097B001 '20.1 .IT DC Fan 60 mm sq. Inlet side, Outlet side Rotating direction Airflow direction Mounting hole Lead wire ■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) ■ Dimensions (unit: mm) (With ribs) ■ Options Finger guards page: p. 558 Resin finger guards page: p. 565 Model no.: 109-139E, 109-139H Model no.: 109-1003G Resin filter kits page: p. 566 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI)