(Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.25 0.30 0.20 0.15 0.10 0.05 0 10 20 30 40 50 0 1.5 1.0 0.5 13.8 V 12 V 6 V (Pa) (CFM) (m3/min) 静圧 風量 0.20 0.15 0.10 0.05 0 10 20 30 40 50 0 1.5 1.0 0.5 13.8 V 12 V 6 V (inch H2O)(Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 10 20 30 40 50 60 70 100 12 V 6 V 13.2 V CATALOG No. C1097B001 '20.1 .IT DC DC Fan 80 mm sq. Static pressure Static pressure Static pressure Airflow Airflow Airflow Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 9A0812G401 With pulse sensor 9A0812S401 With pulse sensor 9A0812H401 With pulse sensor DC Fan 80×80×25 mm San Cooler 80 9A type ■ ■General Specifications
- Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
- Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only.
- Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573.
- Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
- Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
- Sound pressure level (SPL) …………… At 1 m away from the air inlet
- Storage temperature …………………… -30 to +70˚C (Non-condensing) ■ ■Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life [V] [V] [A] [W] [min-1] [m3/min] [CFM] [Pa] [inchH 2O] [dB (A)] [˚C] [h] 9A0812G401 (53000/40˚C) 9A0812S401 6 to 13.8 -20 to +70 40000/60˚C (70000/40˚C) 9A0824G401 (53000/40˚C) 9A0824S401 12 to 27.6 -20 to +70 40000/60˚C (70000/40˚C) The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 598. PWM control The mark indicates Short Lead Time Service applicable models. See p. 626 for details.
(Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.25 0.30 0.20 0.15 0.10 0.05 0 10 20 30 40 50 0 1.5 1.0 0.5 27.6 V 24 V 12 V (Pa) (CFM) (m3/min) 静圧 風量 0.20 0.15 0.10 0.05 0 10 20 30 40 50 0 1.5 1.0 0.5 27.6 V 24 V 12 V (inch H2O) (inch H2O) (CFM) (m3/min) 静圧 風量 0.12 0.10 0.08 0.06 0.04 0.02 0 20 30 40 0 0.5 1.0 (Pa) 27.6 V 24 V 12 V (inch H2O) (CFM) (m3/min) 静圧 風量 0.12 0.10 0.08 0.06 0.04 0.02 0 20 30 40 0 0.5 1.0 (Pa) 13.8 V 12 V 6 V (inch H2O) (CFM) (m3/min) 静圧 風量 0.10 0.08 0.06 0.04 0.02 0 20 30 40 0 0.5 1.0 (Pa) 27.6 V 24 V 14 V (inch H2O) (CFM) (m3/min) 静圧 風量 0.10 0.08 0.06 0.04 0.02 0 20 30 40 0 0.5 1.0 (Pa) 13.8 V 12 V 7 V (Pa) (CFM) (m3/min) 静圧 風量 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 10 20 30 40 50 0 1.5 1.0 0.5 27.6 V 24 V 12 V (inch H2O) (Pa) (CFM) (m3/min) 静圧 風量 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0 10 20 30 40 50 0 1.5 1.0 0.5 13.8 V 12 V 6 V (inch H2O) (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 10 20 30 40 50 60 70 100 24 V 12 V 26.4 V DC CATALOG No. C1097B001 '20.1 .IT DC Fan 80 mm sq. Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Airflow Airflow Airflow Airflow Airflow Airflow Airflow Airflow Airflow Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 9A0812F401 With pulse sensor 9A0812M401 With pulse sensor 9A0812L401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range Operating voltage range Operating voltage range Operating voltage range 9A0824G401 With pulse sensor 9A0824S401 With pulse sensor 9A0824H401 With pulse sensor 9A0824F401 With pulse sensor 9A0824M401 With pulse sensor 9A0824L401 With pulse sensor DC Fan 80×80×25 mm San Cooler 80 9A type ■ ■General Specifications
- Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
- Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only.
- Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573.
- Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
- Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
- Sound pressure level (SPL) …………… At 1 m away from the air inlet
- Storage temperature …………………… -30 to +70˚C (Non-condensing) ■ ■Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life [V] [V] [A] [W] [min-1] [m3/min] [CFM] [Pa] [inchH 2O] [dB (A)] [˚C] [h] 9A0812G401 (53000/40˚C) 9A0812S401 6 to 13.8 -20 to +70 40000/60˚C (70000/40˚C) 9A0824G401 (53000/40˚C) 9A0824S401 12 to 27.6 -20 to +70 40000/60˚C (70000/40˚C) The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Differs according to the model. Refer to the table on p. 598. PWM control The mark indicates Short Lead Time Service applicable models. See p. 626 for details.
+50 300 0 80±0.5 71.5±0.3 25±0.5 (4) (4) (10) 4-ø4.3±0.3 80±0.5 71.5±0.3 リード線 AWG24 UL 1007 回転方向 風吹出方向 取付用穴 ø90 71.5±0.3 4-ø4.5 78.5 71.5±0.3 78.5 CATALOG No. C1097B001 '20.1 .IT DC DC Fan 80 mm sq. Inlet side, Outlet side Rotating direction Airflow direction Mounting hole Lead wire ■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) ■ Dimensions (unit: mm) (With ribs) ■ Options Finger guards page: p. 558 Resin finger guards page: p. 565 Model no.: 109-049E, 109-049H, 109-049C Model no.: 109-1002G Resin filter kits page: p. 566 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI)