9S0612S401 SANYODENKI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

(Pa)(inch H2O) 静圧 風量 0.25 0.20 0.15 0.10 0.05 0 5 10 15 20 25 (CFM) (m3/min) 13.8 V 12 V 6 V (Pa)(inch H2O) 静圧 風量 0.25 0.20 0.15 0.10 0.05 0 5 10 15 20 25 (CFM) (m3/min) 13.8 V 12 V 5 V 0.1 0.2 0.3 0.4 0.5 1.2 0 10 30 20 40 0.20 0.4 0.6 0.8 1.0 100 120 静圧 風量 (inch H2O) (Pa) 13.8 V 12 V 5 V (m3/min) (CFM) DC CATALOG No. C1097B001 '20.1 .IT DC Fan 60 mm sq. Static pressure Static pressure AirflowAirflow Static pressure Airflow Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 9S0612S401 With pulse sensor 9S0612H401 With pulse sensor 9S0612F401 With pulse sensor DC Fan 60×60×25 mm San Ace 60 9S type Silent Fan ■ ■General Specifications

  • Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
  • Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only.
  • Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573.
  • Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
  • Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
  • Sound pressure level (SPL) …………… At 1 m away from the air inlet
  • Storage temperature …………………… -30 to +70˚C (Non-condensing) ■ ■Specifications The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers. Model no. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life [V] [V] [A] [W] [min-1] [m3/min] [CFM] [Pa] [inchH 2O] [dB (A)] [˚C] [h] 9S0612S401 -10 to +70 40000/60˚C (70000/40˚C) The following sensor and control options are available for selection. Differs according to the model. Refer to the table on p. 609. Without sensor Lock sensor PWM control The mark indicates Short Lead Time Service applicable models. See p. 626 for details.

(3) 25±0.5 (3) 60±0.5 50±0.3 4-ø4.3±0.3 50±0.3 60±0.5 (10) +50 300 0 リード線 AWG24 UL 1007 風吹出方向 回転方向 取付用穴 62.7 29.7 29.7 4-ø4.550±0.3 50±0.3 (Pa)(inch H2O) 静圧 風量 0.125 0.100 0.075 0.050 0.025 0 5 10 15 20 25 (CFM) (m3/min) 12 V 13.8 V 6 V CATALOG No. C1097B001 '20.1 .IT DC DC Fan 60 mm sq. Rotating direction Airflow direction Mounting hole Lead wire Inlet side, Outlet side ■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) ■ Dimensions (unit: mm) (With ribs) ■ Options Finger guards page: p. 558 Resin finger guards page: p. 565 Model no.: 109-139E, 109-139H Model no.: 109-1003G Resin filter kits page: p. 566 Model no.: 109-1003F13 (13PPI), 109-1003F20 (20PPI), 109-1003F30 (30PPI), 109-1003F40 (40PPI) Static pressure Airflow Operating voltage range 9S0612M401 With pulse sensor ■ Airflow - Static Pressure Characteristics