N6700 Modular Power System Family Low-Profile MPS Mainframes N6700C–N6702C, N6710C–N6712C DC Power Modules N6731B–N6786A Data Sheet

within 1U of rack space (1.75 in./44 mm). Figure 1. Connectivity: GPIB, 10/100 Base-T ethernet, and USB 2.0 all standard often require multiple power sources. simple DC power requirements. with the LXI Class C specification. be cleared from the front panel. control, and setup of the MPS.

Figure 2. Output sequencing set to turn on or to turn off with a delay. down the modules in a particular order. across multiple N6700 mainframes. to its slowest change of up to 10 seconds. N6700 manually or via computer control. of the paralleled power supplies. manually or via computer control. module and three 100 W DC modules.

500 W modules in an N6700C 400 W MPS

module at its full rated output power.

Plug high power mainframes into standard AC sockets without dedicated high current AC circuits When you first turn on the N6702C

1200 W MPS mainframe, the mainframe

automatically senses the power available from the AC line. If the AC line voltage is such that the resulting current would exceed a standard AC outlet rating, the mainframe automatically scales back the available output power to prevent overloading the AC line. The N6702C will limit the output power to 600 W allowing the high power mainframe to be plugged into any standard outlet. This is very convenient for initial bench checkout of the MPS system. It is also very convenient for test development, which is typically done on the bench when DUT is not yet driven to full power. You can also control this power reduction by manually allocating less than the full available mainframe power among the modules. As a result, the N6702C will draw less power (and less current) from the AC line. Triggering The N6700 Low-Profile MPS mainframe has hardware trigger in/trigger out signals which permit the N6700 to be synchronized with external events. For example, a switch closure in the fixture can trigger the N6700 to apply voltage to the DUT or take a measurement. Drivers The N6700 comes with both VXI plug&play drivers and IVI-COM drivers. LabView drivers are also available at NI.COM. Programming language The N6700 supports SCPI (Standard Commands for Programmable Instruments). Firmware updates The N6700 firmware is stored in FLASH ROM and can be easily updated when new features become available. Firmware can be downloaded into the N6700 over GPIB, LAN, or USB using the supplied firmware update utility program. Keysight recommends that you keep your N6700 system up to date with the latest firmware available at www.keysight.com/find/N6700firmware . Output disconnect and polarity reversal relays Modules in the N6700 can be individually ordered with optional Output Disconnect Relays (option 761) or Output Disconnect/ Polarity Reversal Relays (option 760). See the table on page 14 for option 760 and 761 availability. All relays are built into the module, so no additional wiring or rack space is needed to incorporate the relay function. Although the plus and minus rail of the output power mesh are physically discon - nected from the output terminals with options 760 and 761, a small AC network is still connected across the plus and minus output terminals, This AC network is required for EMI compliance. With option 761, Output Disconnect Relays, mechanical relays disconnect both the plus and minus side of the power supply, including the sense leads. With option 760, Output Disconnect/ Polarity Reversal Relays, mechanical relays switch the leads on both the plus and the minus side of the power supply, including the sense leads, resulting in a voltage polarity reversal at the DUT. In addition to polarity reversal, option 760 provides the same output disconnect function as option 761. Note: Output current is limited on some modules when option 760 Output Disconnect/Polarity Reversal Relays is installed. See the “Available options” table on page 14 for more information about maximum current limitations with option 760. 4 | Keysight | N6700 Modular Power System Family - Data Sheet

DC power modules are the perfect fit. found on linear power supplies.

50 V, or 50 V to 0 V for example, can be

accomplished in less than 1.5 milliseconds.

01 A5 A

50 W Curve

100 W Curve

2 A 3 A – 100 W output

flexibility by providing autoranging outputs. low current operating points.

50 A, and 500 W can provide full power at

10 V @ 50 A (= 500 W),

20 V @ 25 A (= 500 W),

15 V @ 33 A (= 500 W),

1000 W non-autoranging power supply. requirements are determined. Figure 7. Autoranging characteristic

Figure 8. High speed test extensions LIST mode provides the N6730/40/50/70 DC power modules. ing the computer I/O from the process. operation and in DUT standby mode. during a pulsed output voltage. on both programming and measurement. measurements are needed during test.

applications

The N6780 Series of Source/Measure Units offer the highest level of performance in the N6700 Series. These SMUs feature highly accurate measurements down to nanoamperes while providing operation as a DC voltage source, DC current source, and electronic load. For details on these products and how they can be used for applications including battery drain analysis and functional test, visit www.keysight.com/find/N6780 and download the N6780 Series Source/ Measure Units (SMUs) for the N6700 Modular Power System Data Sheet , literature number 5990-5829EN. * Note that the output response time is less than 5 milliseconds per voltage change, so steps of less than 5 milliseconds will not achieve their final output voltage value before moving on to the next step. This is useful when trying to create a smooth waveform. 8 | Keysight | N6700 Modular Power System Family - Data Sheet

For detailed product specifications and characteristics, refer to the Keysight N6700 Modular Power System Family Specifications Guide at DC Power Module Feature Map Feature (  = available) DC power N673xB, N674xB, N677xA High-performance N675xA Precision N676xA

50 W output rating N6731B – N6736B N6751A N6761A

100 W output rating N6741B – N6746B N6752A N6762A

300 W output rating N6773A – N6777A N6753A, N6754A N6763A, N6764A

500 W output rating N6755A, N6756A N6765A, N6766A

Output disconnect relays Option 761 Option 761 Option 761 Output disconnect/polarity reversal relays Option 760 Option 760 Option 760 Autoranging output capability   Voltage or current turn-on priority N6761A, N6762A Precision voltage and current measurements  Low voltage and current output ranges N6761A, N6762A Low voltage and current measurement ranges  200 µA measurement range (N6761A/N6762A only) Option 2UA Simultaneous voltage and current scope traces  Output list capability (High speed test extensions) Option 054 Option 054  Array readback capability (High speed test extensions) Option 054 Option 054  Programmable sample rate (High speed test extensions) Option 054 Option 054  Double-wide (Occupies two channel locations) N6753A, N6756A N6763A, N6766A Feature (  = available) Source/measure units (SMU) Application-specific N6781A N6785A N6782A N6786A N6784A N6783A-BAT N6783A-MFG Output rating 20 W 80 W 20 W 80 W 20 W 24 W 18 W 4-quadrant operation  Auxiliary voltage measurement input   Output disconnect relays      Option 761 Option 761 Negative voltage protection        Voltage or current priority mode      Programmable output resistance   600 mV output range    300 mA output range   100 mA, 10 mA output ranges 

1 V, 100 mV measurement ranges   

100 mA, 1 mA, 10 μA measurement ranges    8A, 100 mA, 1 mA measurement range   150 mA measurement range   Simultaneous voltage and current measurements      Seamless measurement autoranging     Output list capability        Array readback capability        Programmable sample rate        Double-wide (occupies two channel locations)   9 | Keysight | N6700 Modular Power System Family - Data Sheet

DC Power Module Key Performance Specifications Note: This data sheet does not include a comprehensive list of all power module specifications and characteristics. Complete performance specifications and supplemental characteristics for all power Keysight N6700 Modular Power System Family Specifications Guide , part number N6700-90001. DC output ratings (volts/amps/watts) Ripple & noise (p-p/rms) Voltage programming accuracy Current programming accuracy Voltage measurement accuracy Current measurement accuracy N6731B 5 V/10 A/50 W 10 mV/2 mV 0.1% + 19 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 20 mA N6741B 5 V/20 A/100 W 20 mV/2 mV 0.1% + 19 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 20 mA N6743B 20 V/5 A/100 W 14 mV/3 mV 0.1% + 20 mV 0.15% + 20 mA 0.1% + 20 mV 0.15% + 5 mA N6744B 35 V/3 A/105 W 15 mV/5 mV 0.1% + 35 mV 0.15% + 20 mA 0.1% + 35 mV 0.15% + 4 mA N6746B 100 V/1 A/100 W 30 mV/18 mV 0.1% + 100 mV 0.15% + 10 mA 0.1% + 100 mV 0.15% + 2 mA N6753A 20 V/50 A/300 W 5 mV/1 mV 0.06% + 10 mV 0.1% + 30 mA 0.05% + 10 mV 0.1% + 30 mA N6754A 60 V/20 A/300 W 6 mV/1 mV 0.06% + 25 mV 0.1% + 12 mA 0.05% + 25 mV 0.1% + 8 mA N6755A 20 V/50 A/500 W 5 mV/1 mV 0.06% + 10 mV 0.1% + 30 mA 0.05% + 10 mV 0.1% + 30 mA N6756A 60 V/17 A/500 W 6 mV/1 mV 0.06% + 25 mV 0.1% + 12 mA 0.05% + 25 mV 0.1% + 8 mA N6763A 1 20 V/50 A/300 W 5 mV/1 mV 0.03% + 5 mV 0.1% + 15 mA 0.03% + 10 mV 0.1% + 10 mA N6764A 1 60 V/20 A/300 W 6 mV/1 mV 0.03% + 12 mV 0.1% + 15 mA 0.03% + 25 mV 0.1% + 5 mA N6765A 1 20 V/50 A/500 W 5 mV/1 mV 0.03% + 5 mV 0.1% + 15 mA 0.03% + 10 mV 0.1% + 10 mA N6766A 1 60 V/17 A/500 W 6 mV/1 mV 0.03% + 12 mV 0.1% + 15 mA 0.03% + 25 mV 0.1% + 5 mA N6773A 20 V/15 A/300 W 20 mV/3 mV 0.1% + 20 mV 0.15% + 60 mA 0.1% + 20 mV 0.15% + 15 mA N6775A 60 V/5 A/300 W 35 mV/9 mV 0.1% + 60 mV 0.15% +60 mA 0.1% + 60 mV 0.15% +12 mA N6776A 100 V/3 A/300 W 45 mV/18 mV 0.1% + 100 mV 0.15% + 30 mA 0.1% + 100 mV 0.15% + 6 mA N6777A 150 V/2 A/300 W 68 mV/27 mV 0.1% + 150 mV 0.15% + 30 mA 0.1% + 150 mV 0.15% + 6 mA 1. These power modules have multiple output and measurement ranges; values shown are for the highest range. 2. These power modules have multiple measurement ranges; values shown are for the highest range. 10 | Keysight | N6700 Modular Power System Family - Data Sheet

DC Power Analyzer Mainframe Key Characteristics Interface capabilities GPIB SCPI – 1993, IEEE 488.2 compliant interface LXI compliance Class C USB 2.0 Requires Keysight IO Library version M.01.01 or 14.0 and up 10/100 LAN Requires Keysight IO Library version L.01.01 or 14.0 and up Environmental conditions Operating environment Indoor use, installation category II (for AC input), pollution degree 2 Temperature range 0 °C to 55 °C (output current is derated 1% per °C above 40 °C ambient temperature) Relative humidity Up to 95% Altitude Up to 2000 meters AC input Input ratings ~ 100 VAC – 240 VAC; 50/60/400 Hz Power consumption 1000 VA (N6700C)

1440 VA (N6701C)

1440 VA (N6702C @ < 180 VAC input)

2200 VA (N6702C @ > 180 VAC input)

Power factor 0.99 @ nominal input and rated power Net weight N6700C with 4 modules (typical) 12.73 kg/28 lbs. N6701C with 4 power modules 11.82 kg/26 lbs. N6702C with 4 power modules 14.09 kg/31 lbs. Dimensions N6700C/N6701C N6702C Height/width/depth 44.45 mm/432.5 mm/585.6 mm 44.45 mm/432.5 mm/633.9 mm 11 | Keysight | N6700 Modular Power System Family - Data Sheet

Ordering Information

The DC power analyzer system is available two ways – You can order an N6700C, N6701C or N6702C mainframe and various modules as separate products. (See steps below.) Each item will arrive in a separate box so that you can assemble the system yourself. – You can order an N6710C, N6711C or N6712C system, which is a build- to-order system that is shipped as a fully assembled multiple-output power supply. (See pages 15 and 16 for N6710C, N6711C and N6712C ordering information. When ordering the N6700 MPS as a mainframe and modules, follow these steps. Step 1 Select which mainframe you want based on your power requirements. Step 2 Select the appropriate documentation and line cord options. Step 3 Order 1 to 4 modules (see next page). If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 3 for an explanation of Keysight’s power management capability. Each module occupies one module slot, except for the N6753A–N6756A and N6763A–N6766A which occupy two module slots. Mainframes N6700C Low-profile modular power system mainframe, 400 W Holds 1 to 4 modules. Total available output power = 400 W N6701C Low-profile modular power system mainframe, 600 W Holds 1 to 4 modules. Total available output power = 600 W N6702C Low-profile modular power system mainframe, 1200 W Holds 1 to 4 modules. Total available output power = 1200 W Available options to the N6710C, N6711C, and N6712C systems N6709C Rack mount kit Required for rack mounting. Standard rack mount hardware will not work. N6708A Filler panel kit Required when you have less than 4 modules in a mainframe. Each filler kit contains 3 filler panels. OL1 Full documentation on CD-ROM and printed users guide

900 Power cord, United Kingdom, P/N 8120-1351

901 Power cord, Australia, New Zealand, P/N 8120-1369

902 Power cord, Europe, Korea, P/N 8120-1689

903 Power cord, USA, Canada, 120 V, P/N 8120-4383

904 Power cord, USA, Canada, 240 V, P/N 8120-0698

906 Power cord, Switzerland, P/N 8120-2104

912 Power cord, Denmark, P/N 8120-2956

917 Power cord, South Africa, India, P/N 8120-4211

918 Power cord, Japan, 100 V, P/N 8120-5342

Note: For model N6712C, the maximum output power is limited to 600 W at 100 VAC. To achieve full output power of 1200 W, you must use option 929 and operate at 200 VAC.

919 Power cord, Israel, P/N 8120-6800

920 Power cord, Argentina, P/N 8120-6869

921 Power cord, Chile, P/N 8120-6980

922 Power cord, China, P/N 8120-8376

927 Power cord, Thailand, Brazil, P/N 8120-8871

929 Power cord, Japan, 200 V, P/N 8121-1392

Note: This option is available only on model N6702C Step 4 For proper operation, you must fill any empty module slots with filler panels. When configuring a mainframe with less than four filled module slots, you MUST order a filler panel kit. Each kit contains three filler panels. Each filler panel fills one empty module slot. Step 5 If you will be rack mounting your N6700, you MUST order the rack mount kit. 12 | Keysight | N6700 Modular Power System Family - Data Sheet

Ordering Information, continued Modules Order 1 to 4 modules to be installed in each N6700C, N6701C or N6702C mainframe. (To order modules as part of the N6710C, N6711C or N6712C build-to-order systems, see page 15). If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 3 for an explanation of Keysight’s power management capability. You can individually specify each option for each module. For example, you can order one module with Option 761 Output Disconnect Relays while the remaining modules have no relay options. As your needs change and you want to change configuration or add more modules to existing N6700C, N6701C or N6702C mainframes, use this ordering information to order the required modules. Modules N6730 50 W DC power modules N6731B 5 V, 10 A, 50 W DC power module N6732B 8 V, 6.25 A, 50 W DC power module N6733B 20 V, 2.5 A, 50 W DC power module N6734B 35 V, 1.5 A, 50 W DC power module N6735B 60 V, 0.8 A, 50 W DC power module N6736B 100 V, 0.5 A, 50 W DC power module N6740 100 W DC power modules N6741B 5 V, 20 A, 100 W DC power module N6742B 8 V, 12.5 A, 100 W DC power module N6743B 20 V, 5 A, 100 W DC power module N6744B 35 V, 3 A, 100 W DC power module N6745B 60 V, 1.6 A, 100 W DC power module N6750 high- performance, auto-ranging DC power modules N6751A 50 V, 5 A, 50 W high-performance autoranging DC power module N6752A 50 V, 10 A, 100 W high-performance autoranging DC power module N6753A 20 V, 50 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6754A 60 V, 20 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6755A 20 V, 50 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6756A 60 V, 17 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6760 precision DC power modules N6761A 50 V, 1.5 A, 50 W precision DC power module N6762A 50 V, 3 A, 100 W precision DC power module N6763A 20 V, 50 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6764A 60 V, 20 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6765A 20 V, 50 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6766A 60 V, 17 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6770 300 W DC power modules N6773A 20 V, 15 A, 300 W DC power module N6774A 35 V, 8.5 A, 300 W DC power module N6775A 60 V, 5 A, 300 W DC power module N6776A 100 V, 3 A, 300 W DC power module N6777A 150 V, 2 A, 300 W DC power module N6780 ~80 W application-specific modules N6781A 20 V, ± 3 A, 20 W source/measure unit N6782A 20 V, ± 3 A, 20 W source/measure unit N6783A-BAT 8 V, 3 A, 24 W battery charge/discharge module N6783A-MFG 6 V, 3 A, 18 W mobile communications module N6784A ± 20 V, ± 3 A, 20 W source/measure unit N6785A 20 V, +/-8 A, 80 W source/measure unit N6786A 20 V, +/-8 A, 80 W source/measure unit 13 | Keysight | N6700 Modular Power System Family - Data Sheet

Ordering Information, continued Available options to N6700 modules N6731B- N6736B 50 W DC power modules N6741B- N6746B 100 W DC power modules N6751A- N6756A high- performance autoranging DC power modules N6761A- N6766A precision DC power modules N6773A- N6776A 300 W DC power modules N6781A, N6782A, N6784A, N6785A, N6786A, SMU modules N6783A-BAT N6783A-MFG application-specific Output disconnect relays 761 761 761 761 761 Standard 761 Output disconnect and polarity reversal relays 760 760 1, 2 760 1 760 1 760 2 Not available Not available High speed test extensions (HSTE) 054 054 054 Standard 054 Standard Standard 200 microampere measurement range Not available Not available Not available 2UA 3 Not available Not available Not available Commercial calibration with test results data UK6 UK6 UK6 UK6 UK6 UK6 UK6 ISO 17025 calibration certificate 1A7 1A7 1A7 1A7 1A7 Not available 1A7 1. Option 760 is not available on Models N6741B, N6751A, N6752A, N6761A, N6762A. 2. Option 760 limits the output current to 10 A maximum on Models N6742B and N6773A. 3. Option 2UA is only available on Models N6761A and N6762A. 14 | Keysight | N6700 Modular Power System Family - Data Sheet

N6700 build-to-order system To purchase an N6700 system, order an N6710C, N6711C, or N6712C. These model numbers are build-to-order systems that are shipped as a fully tested and assembled multiple-output power supplies. Each system consists of one mainframe plus optionally 1 to 4 modules. Each mainframe has four module slots to hold modules. Each module occupies one module slot, except for the N6753A–N6755A and the N6763A–N6766A, which occupy two module slots. To specify which modules you want installed in the system, the modules are ordered as options to the system model number. If you order less than four modules, the empty slots will be automatically filled with blank filler panels. You must order at least one module. If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 3 for an explanation of Keysight’s powermanage - ment capability. If you prefer to purchase a mainframe and modules as separate pieces, see page 14. Build-to-order system N6710C System Build-to-order modular power system, 400 W Consists of 1 N6700C mainframe with total available power of 400 W N6711C System Build-to-order modular power system, 600 W Consists of 1 N6701C mainframe with total available power of 600 W N6712C System Build-to-order modular power system, 1200 W Consists of 1 N6702C mainframe with total available power of 1200 W Available options to the N6715B system N6709C Rack mount kit Required for rack mounting. Standard rack mount hardware will not work Full documentation on CD-ROM and printed users guide OL1 Full documentation on CD-ROM and printed users guide Note: For model N6712C, the maximum output power is limited to 600 W at 100 VAC. To achieve full output power of 1200 W, you must use option 929 and operate at 200 VAC. Note: This option is available only on model N6712C 15 | Keysight | N6700 Modular Power System Family - Data Sheet

Ordering Information, continued Modules as options to N6710C, N6711C, or N6712C Order 1 to 4 modules as options to an N6710C, N6711C or N6712C, specify its model number, followed by “-ATO.” For example, to order an N6731B as an option to the N6710C, you would specify “-ATO.” For example, to order an N6731B as an option to the N6710C, you would specify “N6731B-ATO”as the option. (To order modules as separate products, see page 14). If the sum of the power of the modules exceeds the available output power rating on the mainframe, see page 3 for an explanation of Keysight’s power management capability. You can individually specify each option for each module. For example, you can order one module with Option 761 Output Disconnect Relays while the remaining modules have no relay options. Module options for N6710C, N6711C, and N6712C systems N6730 50 W DC power modules N6731B-ATO 5 V, 10 A, 50 W DC power module N6732B-ATO 8 V, 6.25 A, 50 W DC power module N6733B-ATO 20 V, 2.5 A, 50 W DC power module N6734B-ATO 35 V, 1.5 A, 50 W DC power module N6735B-ATO 60 V, 0.8 A, 50 W DC power module N6736B-ATO 100 V, 0.5 A, 50 W DC power module N6740 100 W DC power modules N6741B-ATO 5 V, 20 A, 100 W DC power module N6742B-ATO 8 V, 12.5 A, 100 W DC power module N6743B-ATO 20 V, 5 A, 100 W DC power module N6744B-ATO 35 V, 3 A, 100 W DC power module N6745B-ATO 60 V, 1.6 A, 100 W DC power module N6750 high-performance, auto-ranging DC power modules N6751A-ATO 50 V, 5 A, 50 W high-performance autoranging DC power module N6752A-ATO 50 V, 10 A, 100 W high-performance autoranging DC power module N6753A-ATO 20 V, 50 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6754A-ATO 60 V, 20 A, 300 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6755A-ATO 20 V, 50 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6756A-ATO 60 V, 17 A, 500 W high-performance autoranging DC power module (occupies 2 of 4 mainframe slots) N6760 precision DC power modules N6761A-ATO 50 V, 1.5 A, 50 W precision DC power module N6762A-ATO 50 V, 3 A, 100 W precision DC power module N6763A-ATO 20 V, 50 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6764A-ATO 60 V, 20 A, 300 W precision DC power module (occupies 2 of 4 mainframe slots) N6765A-ATO 20 V, 50 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6766A-ATO 60 V, 17 A, 500 W precision DC power module (occupies 2 of 4 mainframe slots) N6770 300 W DC power modules N6773A-ATO 20 V, 15 A, 300 W DC power module N6774A-ATO 5 V, 8.5 A, 300 W DC power module N6775A-ATO 60 V, 5 A, 300 W DC power module N6776A-ATO 100 V, 3 A, 300 W DC power module N6777A-ATO 150 V, 2 A, 300 W DC power module N6780 ~80 W application-specific modules N6781A-ATO 20 V, ± 3 A, 20 W source/measure unit N6782A-ATO 20 V, ± 3 A, 20 W source/measure unit N6783A-BAT 8 V, 3 A, 24 W battery charge/discharge module N6783A-MFG 6 V, 3 A, 18 W mobile communications module N6784A-ATO ± 20 V, ± 3 A, 20 W source/measure unit N6785A-ATO 20 V, +/-8 A, 80 W source/measure unit N6786A-ATO 20 V, +/-8 A, 80 W source/measure unit 16 | Keysight | N6700 Modular Power System Family - Data Sheet

Need a power solution for R&D bench work? The Keysight N6705C DC Power Analyzer saves time – Provides unrivaled productivity gains for sourcing and measuring DC voltage and current into your DUT by integrating up to 4 advanced power supplies with DMM, scope, arb, and data logger features. – Eliminates the need to gather multiple pieces of equipment, create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. – Eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all the functions and measurements are available at the front panel. – Modular system: Uses the same DC power modules at the N6700 low- profile modular power system. Complete specifications can be found in the N6705C DC Power Analyzer Data Sheet, publication 5992-1880EN. For more information go to www.keysight.com/find/dcpoweranalyzer 17 | Keysight | N6700 Modular Power System Family - Data Sheet

18 | Keysight | N6700 Modular Power System Family - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Infoline www.keysight.com/find/Infoline Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-06-08-16) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2012 - 2017 Published in USA, January 13, 2017 5992-1857EN www.keysight.com www.keysight.com/find/n6700 Evolving Our unique combination of hardware, software, support, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight