DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

1950 MHz SAW Bandpass Filter

Data Sheet: Rev D 04-01-15 - 1 of 6 - Disclaimer: Subject to change without notice RFMD + TriQuint = Qorvo

Applications

  • LTE Band 1 UL Filter for Infrastructure
  • 3G, 4G Multi-Standard
  • Wireless Repeaters
  • General Purpose Wireless
  • Base Stations SMP-12, 3.00 x 3.00 x 1.22 mm Functional Block Diagram 1 6 5Input Output Gnd Gnd Gnd Gnd Product Features
  • 60 MHz Bandwidth
  • Low Loss
  • High Attenuation
  • Single-ended Operation
  • No impedance matching required for operation at 50 Ω
  • Small Size: 3.00 x 3.00 x 1.22 mm
  • Ceramic Surface Mount Package (SMP)
  • Hermetically Sealed
  • RoHS Compliant, Pb-Free

Ordering Information

Part No. Description

856532 Packaged part

856532-EVB Evaluation board Standard T/R size = 5000 units/reel Pin Configuration – Single Ended Pin No. Label

2 Input

5 Output

1,3, 4 6 Ground General Description 856532 is a Band 1 Uplink filter for general purpose wireless applications. This filter was specifically designed in a 3x3 mm hermetic package f or base station applications and is part of our wide portfolio of R F filters in the same package. 856532 has l ow insertion loss, coupled with high attenuation and good power handling, making this filter a natural choice for our customers uplink RF filteri ng needs and other general purpose applications. 856532 require no matching components , making filter implementation easy. Pb

Data Sheet: Rev D 04-01-15 - 2 of 6 - Disclaimer: Subject to change without notice RFMD + TriQuint = Qorvo Absolute Maximum Ratings Parameter Rating Notes: 1. Operation of this device outside the parameter r anges given may cause permanent damage. 2. Specifications are not guaranteed over all operating conditions. 3. Input Power is targeted for an applied CW modula ted RF signal at 105 ° C for 10 years. Storage Temperature (1) −40 to +105 ° C Operating Temperature (2) −30 to +85 ° C RF Input Power (3) +10 dBm Electrical Specifications (1) Test conditions unless otherwise noted: (2) Temp= −30 ° C to +85 ° C Parameter (3) Conditions Min Typ (4) Max Units Center Frequency - 1950 - MHz Maximum Insertion Loss 1920 – 1980 MHz - 2.5 3.0 dB Amplitude Ripple (5) - 0.7 1.5 dB p-p Absolute Attenuation (6) 10 – 1000 MHz 1000 – 1880 MHz 2110 – 2170 MHz 2170 – 3800 MHz 3800 – 5000 MHz 31.7 31.8 43.6 29.1 22.5 - dB Input/Output Return Loss 1920 – 1980 MHz 8 9.6 - dB Test conditions unless otherwise noted: (2) Temp= −40 ° C to +85 ° C Parameter (3) Conditions Min Typ (4) Max Units Maximum Insertion Loss 1920 – 1980 MHz 2.5 3.2 dB Amplitude Ripple (5) 1920 – 1980 MHz 0.7 1.5 dB p-p Absolute Attenuation (6) 10 – 1000 MHz 1000 – 1880 MHz 2110 – 2170 MHz 2170 – 3800 MHz 3800 – 5000 MHz 3800 – 5000 MHz at +105 ° C (8) 31.7 31.8 43.6 29.1 22.5 22.5 - dB Input/Output Return Loss 1920 – 1980 MHz 1920 – 1980 MHz at +105 ° C (8) 9.6 8.6 - dB Source Impedance (7) single-ended - 50 - Ω Load Impedance (7) single-ended - 50 - Ω Notes: 1. All specifications are based on the TriQuint sch ematic for the main reference design shown on page 3. 2. In production, devices will be tested at room te mperature to a guardbanded specification to ensure electrical compliance over temperature. 3. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances. 4. Typical values are based on average measurements at room temperature. 5. Evaluated as peak-to-adjacent valley ripple. 6. Relative to zero dB. 7. This is the optimum impedance in order to achiev e the performance shown. 8. Extended temperature operation: the filter can be operated up to +105 ° C with de -rated specification as noted.

Data Sheet: Rev D 04-01-15 - 3 of 6 - Disclaimer: Subject to change without notice RFMD + TriQuint = Qorvo Evaluation Board CH JJJYM 960700 1,3,4,6 2 5 50 50 ΩΩ ΩΩ Ω Ω ΩΩ Notes: 1. No impedance matching required. 0.2 µm thick. Hole plating: Copper min .0008 µm thick. Bill of Material Reference Des. Value Description Manuf. Part Number U1 - 1950 MHz SAW filter TriQuint 856532 SMA - SMA connector Radiall 9602-1111-018 PCB - 3-Layer TriQuint 960700 PCB Mounting Pattern .96 3.20 SQ 1.27 .38 .81 1.70 Notes: 1. All dimensions are in millimeters. Angles are i n degrees. 2. This drawing specifies the mounting pattern used on the TriQuint evaluation board for this product. Some modification may be necessary to suit end user assembly materials and processes.

Data Sheet: Rev D 04-01-15 - 4 of 6 - Disclaimer: Subject to change without notice RFMD + TriQuint = Qorvo Performance Plots – Evaluation Board Test conditions unless otherwise noted: Temp= +25 ° C

Data Sheet: Rev D 04-01-15 - 5 of 6 - Disclaimer: Subject to change without notice RFMD + TriQuint = Qorvo Package Information, Marking and Dimensions 0.69 1.22 NOM. 1.32 MAX. 0.75 0.60 1.50 0.75 3.00 3.00 CH code Marking Date code JJJYM logo ID dot TriQuint Package Style: SMP-12A Body: Al 2O3 ceramic. Lid: Kovar , Ni plated. Terminations: Au plating 0.5 - 1.0 μm, over a 2-6 μm Ni plating. The date code consists of: day of the current year (Julian, 3 digits), Y = last digit of the year, and M = manufacturing site code. Notes: 1. All dimensions shown are typical in millimeters. 2. All tolerances are ±0.15 mm except overall length and width ±0.10 mm. 3. An asterisk (*) in front of the marking code ind icates prototype. Tape and Reel information Standard T/R size = 5000 units/reel . All dimensions are in millimeters logo TriQuint Pad 1 ID dot Direction of travel 2.0 Ø13.0 Ø20.2 12.8 Ø330 2.7 Ø102 3.25 Section A-A 1.75 Ø1.5 4.0 A 12.0 5.5 Ø1.5 4.0 2.0 3.25 1.4 0.21 A

Data Sheet: Rev D 04-01-15 - 6 of 6 - Disclaimer: Subject to change without notice RFMD + TriQuint = Qorvo Product Compliance Information ESD Sensitivity Ratings Caution! ESD-Sensitive Device ESD Rating: Class 1B Test:Electrostatic Discharge Sensitivity Testing, Human Body Model (HBM) - com ponent level Standard: ESDA/JEDEC JS-001-2012 ESD Rating: Class B Test: Machine Model (MM) Standard: JEDEC Standard JESD22-A115 Solderability Compatible with both lead- free (260° C maximum reflow temperature) and tin/lead (245° C maximum reflow temperature) soldering processes. Refer to Soldering Profile for recommended guidelines . RoHs Compliance This part is compliant with EU 2002/95/EC RoHS directive (Restrictions on the Use of Certain Hazar dous Substances in Electrical and Electronic Equipment). This product also has the following attributes:

  • Lead Free
  • Halogen Free (Chlorine, Bromine)
  • Antimony Free
  • TBBP-A (C 15 H12 Br 402) Free
  • PFOS Free
  • SVHC Free MSL Rating Not applicable. Hermetic package. Contact Information For the latest specifications, additional product information, worldwide sales and distribution locations: Web: www.triquint.com Tel: 877-800-8584 Email: customer.support@qorvo.com For information about the merger of RFMD and TriQuint as Qorvo: Web: www.qorvo.com For technical questions and application information: Email: flapplication.engineering@tqs.com Important Notice The information contained herein is believed to be reliable. TriQuint makes no warranties regarding the informat ion contained herein. TriQuint assumes no responsibility or liability wha tsoever for any of the information contained herein. TriQuint assumes no responsibility or liab ility whatsoever for the use of the information con tained herein. The information contained herein is provided "AS IS, WH ERE IS" and with all faults, and the entire risk as sociated with such information is entirely with the user. All information contained herein is subject to change w ithout notice. Customers should obtain and verify the latest relev ant information before placing orders for TriQuint products. The information contained herein or any use of such inf ormation does not gr ant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with regard to such inform ation itself or anything described by such information. TriQuint products are not warranted or authorized f or use as critical components in medical, life-savi ng, or life- sustaining applications, or other applications wher e a failure would reasonably be expected to cause s evere personal injury or death.