DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
2-20GHz 20W Benchtop Power Amplifier Datasheet: Rev - 2-06-2014 - 1 of 5 - Disclaimer: Subject to change without notice © 2014 TriQuint Patent No: US 7,215,220 www.triquint.com Standard Configuration SMA (F)Coaxial Input/Output IEC 60320 C14 Compliant AC input 2 Meter AC Power Cord with NEMA 5-15P Front Panel Gain Adjust Air Flow – Side intake – Rear exhaust
Applications
Labwork Test and Measurement Load Pull EMI Test Anaechoic Chambers and Test Ranges Product Features Saturated Power ‐ 20 Watts typical Operating Band ‐ 2 GHz to 20 GHz Solid State MMIC Reliability Multi Element Redundancy Instant On (No Warm Up) Flat Gain Response Excellent Harmonic and Intermodulation Characteristics Optional Accessories Rack Mount Brackets RMO1.0 Alternate AC Cord Configurations General Description TriQuint’s RM022020 Amplifier utilizes our patented Spatium™ combining technology providing unprecedented performance in a general purpose laboratory bench top amplifier. Suitable for use a driver/booster amplifier, enabling more power incident upon the device under test (DUT) this amplifier is an excellent alternative to Traveling Wave Tube Amplifiers (TWTA) The RM022020 amplifier operates instanteously across the 2 GHz ‐ 20 GHz spectrum achieving saturated output powers (Psat) greater than 20 Watts. Front panel manual gain adjustment enables simple, rapid performance optimization. Built-In-Test (BIT) monitors continuously evaluate the amplifier performance and provide instant visual indication of anomalous behavior. Custom configurations and optimized screening conditions are available on request, consult factory.
Ordering Information
RM022020 3A001.b.4.b 2 – 20 GHz 20W Benchtop Amp
2-20GHz 20W Benchtop Power Amplifier Datasheet: Rev - 2-06-2014 - 2 of 5 - Disclaimer: Subject to change without notice © 2014 TriQuint Patent No: US 7,215,220 www.triquint.com Absolute Maximum Ratings Parameter Value RF Input +20dBm Load VSWR 3:1 Operating Temperature -20 to +60 °C Storage Temperature -20 to +75 °C Operation of this device outside the parameter ranges given above may cause permanent damage. These are stress ratings only, and functional operation of the device at these conditions is not implied. Recommended Operating Conditions Parameter Value AC Input (Rear) 85-264 Vac 47-63Hz 300VA Operating Temperature 0 to +50 °C Electrical specifications ar e measured at specified test conditions. Specifications are not guaranteed over all operating conditions. Specifications As measured into a load VSWR < 1.25:1 Parameter Min Typical Max Units Operational Frequency Range 2 20 GHz Power Gain 40 43 dB Gain Adjustment - Manual (Front) 10 dB Gain Flatness vs. Frequency +/-3 dB RF Power @ 5dBm Input 2-10GHz 40 43 dBm RF Power @ 5dBm Input 10-18GHz 39 42 dBm RF Power @ 5dBm Input 18-20GHz 38 39 dBm Input VSWR 1.5:1 2:1 Output VSWR 2.3:1 Noise Figure 8 13 dB Spurious -75 -60 dBc RF I/O (Front) SMA (F) Dimensions (L) x (W) x (H) 17.1 x 16.9 x 5.1 inches
2-20GHz 20W Benchtop Power Amplifier Datasheet: Rev - 2-06-2014 - 3 of 5 - Disclaimer: Subject to change without notice © 2014 TriQuint Patent No: US 7,215,220 www.triquint.com Thermal and Reliability Information Parameter Test Conditions Value Units Thermal Resistance (θJC) (1) Tbase = 85 °C, VD = 28 V, ID_Drive =
3.2 A, Pout = 45 dBm, PDISS = 58 W
2.05 ºC/W Channel Temperature (TCH) 204 °C Median Lifetime (TM) 8.94E+6 Hrs Notes: 1. Thermal resistance measured to back of carrier plate. MMIC mounted on 20 mils CuMo carrier using 1.5 mil 80/20 AuSn. Median Lifetime Typical Performance
2-20GHz 20W Benchtop Power Amplifier Datasheet: Rev - 2-06-2014 - 4 of 5 - Disclaimer: Subject to change without notice © 2014 TriQuint Patent No: US 7,215,220 www.triquint.com Outline Drawings
2-20GHz 20W Benchtop Power Amplifier Datasheet: Rev - 2-06-2014 - 5 of 5 - Disclaimer: Subject to change without notice © 2014 TriQuint Patent No: US 7,215,220 www.triquint.com Important Notice The information contained herein is believed to be reliable. TriQuint makes no warranties regarding the information contained herein. TriQuint assumes no responsibility or liability whatsoever for any of the information contained herein. TriQuint assumes no responsibility or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to change without notice. Customers should obtain and verify the latest relevant info rmation before placing orders for TriQuint products. The information contained herein or any use of such informatio n does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other inte llectual property rights, w hether with regard to such information itself o r anything described by such information. TriQuint products are not warranted or authorized for use as critical compo nents in medical, life-saving, or life- sustaining applications, or other applications where a failu re would reasonably be expected to cause severe personal injury or death. Contact Information For the latest specifications, additional product inform ation, worldwide sales and distribution locations, and information about TriQuint: Email: Spatium-info@tqs.com Fax: +1.805.499.6649 For technical questions and application information: Email: Spatium-info@tqs.com Product Compliance Information ESD Sensitivity Ratings Caution! ESD-Sensitive Device ESD Rating: TBD Value: TBD Test: Human Body Model (HBM) Standard: JEDEC Standard JESD22-A114 ECCN US Department of Commerce: 3A001.b.4.b