6680A KEYSIGHT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
6680A Series Single-Output,
5000 W DC Power Supplies, GPIB
Reliable DC power for manufacturing test and long-term burn-in – Low output ripple and noise – Selectable compensation for inductive loads – Analog control of output voltage and current – Fan-speed control to minimize acoustic noise – Built-in measurements and advanced programmable features – Protection features to ensure DUT safety
Page 2Find us at www.keysight.com Introduction This series of 5000 watt DC power supplies has the exceptional, proven reliability that test system engineers look for. It also has the features needed for easy test system integration. Programming of the DC output and the extensive protection features can be done either from the front panel or using industry standard SCPI commands via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified by using the VXIplug&play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. The 6680A series has extremely low ripple and noise for a 5000 watt DC power supply. This helps the built-in measurement system make extremely accurate current and voltage measurements. Selectable compensation is provided for problem-free powering of inductive loads.
Page 3Find us at www.keysight.com Specifications Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) 6680A 6681A 6682A 6683A 6684A 6680A-J04 Special order option Ripple and noise constant voltage mode from 20 Hz to 20 MHz Current rms 290 mA 190 mA 40 mA 28 mA 23 mA Average programming resolution Voltage Current OVP 1.35 mV 235 mA 30 mV 2.15 mV 155 mA 45 mV 5.7 mV 64 mA 120 mV 8.6 mV 43 mA 180 mV 10.8 mV 34 mA 225 mV 12 mV 260 mA 25 mV Output voltage programming response time* (excluding command processing time) 9 ms 12 ms 45 ms 60 ms 60 ms 9 ms Output common-mode noise current (to signal-ground binding post) rms peak-to-peak 1.5 mA 10 mA 1.5 mA 10 mA 3 mA 20 mA 3 mA 20 mA 3 mA 20 mA 2.0 mA 12.5 mA Specifications (at 0 ° to 55 °C unless otherwise specified) 6680A 6681A 6682A 6683A 6684A 6680A-J04 Special order option Number of outputs 1 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Yes Output ratings Output voltage Output current 0 to 5 V 0 to 875 A 0 to 8 V 0 to 580 A 0 to 21 V 0 to 240 A 0 to 32 V 0 to 160 A 0 to 40 V 0 to 128 A 0 to 3.3 V 0 to 1000 A Programming accuracy (at 25 °C ± 5 °C) Voltage 0.04% + Current 0.1% + 5 mV 450 mA 8 mV 300 mA 21 mV 125 mA 32 mV 85 mA 40 mV 65 mA 5 V 450 A Ripple and noise constant voltage mode from 20 Hz to 20 MHz Voltage rms peak-to-peak 1.5 mV 15 mV 1.5 mV 10 mV 1.5 mV 10 mV 1.0 mV 10 mV 1.0 mV 10 mV 3.4 mV 15 mV Readback accuracy at 25 °C ± 5 °C (percent of reading plus fixed) Voltage 0.05% + ±Current 0.1% + 7.5 mV 600 mA 12 mV 400 mA 32 mV 165 mA 48 mV 110 mA 60 mV 90 mA 7.5 mV 600 mA Load and line regulation Voltage 0.002% + Current 0.005% + 0.19 mV 65 mA 0.3 mV 40 mA 0.65 mV 17 mA 1.1 mV 12 mA 1.5 mV 9 mA 0.19 mV 77 mA Transient response time Less than 900 μs for the output voltage to recover to within 150 mV following a change in load from 100% to 50% or 50% to 100% of the output current rating of the supply * Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current.
Page 4Find us at www.keysight.com Keysight Technologies, Inc. Models: 6680A, 6681A, 6682A, 6683A, 6684A Supplemental characteristics for all model numbers DC floating voltage: Output terminals can be floated up to ± 60 VDC from chassis ground Remote sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Command processing time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for power supplies connected directly to the GPIB. Modulation: (Analog programming of output voltage and current): Input signal: 0 to –5 V for voltage, 0 to +5 V for current Input impedance: 30 kΩ or greater AC input (47 to 63 Hz): 180 to 235 VAC (line-to-line, 3 phase),
27.7 A rms maximum worst case,
21.4 A rms nominal; 360 to 440 VAC,
14.3 A rms maximum worst case,
10.7 A rms nominal (maximum line current includes 5%
unbalanced phase voltage condition.) Output voltage derated 5% at 50 Hz and below 200 VAC Input power: 7350 VA and 6000 W maximum; 160 W at no load GPIB interface capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI command set. Software driver: – IVI-COM – VXIplug&play Size: 425.5 mm W x 221.5 mm H x 674.7 mm D (16.75 in x 8.75 in x 25.56 in) Weight: Net, 51.3 kg (113 lbs); shipping, 63.6 kg (140 lbs) SideOutput Buss Bars Top Buss Bar Detail Rear 12.7 mm 0.5" 28.6 mm 1.13" 30.2 mm 1.19" 65.1 mm 2.56" 27.8 mm 1.09" 9.5 mm 0.38" 12.7 mm 0.5" 674.7 mm 26.56" 667.3 mm 26.27" 574 mm 22.6" 221.5 mm 8.75" 425.5 mm 16.75" 3/8" Diameter (6) 3 3/4"
This information is subject to change without notice. © Keysight Technologies, 2018, Published in USA, August 27, 2018, 5990-9307EN Page 5Find us at www.keysight.com Learn more at: www.keysight.com For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus
Ordering information
The 6680A power supplies come with full documentation on CD-ROM. The CD-ROM includes user’s guide, programming guide, service manual, quick start guide, and application notes. Opt 208 180 to 235 VAC, 3 phase, 47 to 63 Hz Opt 400 360 to 440 VAC, 3 phase, 47 to 63 Hz Opt 602 Two bus bar spacers for paralleling power supplies (p/n 5060-3514) Opt 0L1 Printed user’s and programming guides Opt 0B3 Printed service manual Accessories 1CM028A* Rack mount flange kit 88.1 mm H (3U) and 132.6 mm H (2U) – 4 brackets (5U total) 1CP014A* Double rack mount flange and handle kit 88.1 mm H (2U) and 132.6 mm H (3U) E3663AC Support rails for Keysight rack cabinets P/n 5080-2148 Serial link cable 2 m (6.6 ft.) P/n 5060-3513 Three 30 A replacement fuses for 180 to 235 VAC line P/n 5060-3512 Three 16 A replacement fuses for 360 to 440 VAC line Application notes 6671A/72A/81A/82A/90A System DC Power Supplies Product Overview, 5988-3050EN Keysight DC Power Supplies for Base Station Testing , 5988-2386EN
10 Practical Tips You Need to Know About Your Power Products , 5965-8239E
*Support rails required