Speed and accuracy for test optimization – Small, compact size for bench and system use – Fast, low-noise outputs – Dual-range, precision low current measurement – Built-in measurements and advanced programmable features – Protection features to ensure DUT safety Data Sheet Keysight Technologies 6610C Series Single-Output, 40-50 W GPIB Power Supplies

02 | Keysight | 6610C Series Single-Output, 40-50 W GPIB Power Supplies - Data Sheet This series of linear-regulated 40-50 W DC power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast programming and measurement, and also active downprogramming. It offers many advanced programmable features including stored states and status reporting. Programming is done using industry standard SCPI commands via the GPIB or RS-232. Test system integration is further simplified by using the VXIplug&play drivers. The optional relays simplify system design and troubleshooting. The half-rack size of the 6610C series makes it a convenient DC power supply for the R&D lab bench. The built-in microamp measurement system helps the engineer to easily and accurately monitor the output voltage and current without a complicated test setup.

03 | Keysight | 6610C Series Single-Output, 40-50 W GPIB Power Supplies - Data Sheet Speciications Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) 6611C 6612C 6613C 6614C 6611C-J05 Special order option Average programming resolution Voltage Current 2 mV 1.25 mA 5 mV 0.5 mA 12.5 mV 0.25 mA 25 mV 0.125 mA 3 mV 1.25 mA Sink current 3 A 1.2 A 0.6 A 0.3 A 3 A Specifications (at 0 ° to 55 ° unless otherwise specified) 6611C 6612C 6613C 6614C 6611C-J05 Special Order Option Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Output ratings Voltage Current 0 to 8 V 0 to 5 A 0 to 20 V 0 to 2 A 0 to 50 V 0 to 1 A 0 to 100 V 0 to 0.5 A 0 to 10 V 0 to 5 A Programming accuracy at 25 °C ± 5 °C Voltage Current 0.05% + 5 mV 2 mA 10 mV 1 mA 20 mV 0.75 mA 50 mV 0.5 mA 5 mV 2 mA Ripple and noise

20 Hz to 20 MHz;with outputs ungrounded

or with either terminal grounded Voltage rms peak-to-peak Normal mode rms 0.5 mV 3 mV 2 mA 0.5 mV 3 mV 1 mA 0.5 mV 4 mV 1 mA 0.5 mV 5 mV 1 mA 0.5 mV 3 mV 2 mA DC measurement accuracy via GPIB or front-panel meters with respect to actual output at 25 °C ± 5 °C Voltage 0.03% + Low current range –20 mA to + 20 mA 0.1% + High current range +20 mA to + rated I 0.2% + –20 mA to – rated I 0.2% + 2 mV 2.5 µA 0.5 mA 1.1 mA 3 mV 2.5 µA 0.25 mA 0.85 mA 6 mV 2.5 µA 0.2 mA 0.8 mA 2 mV 2.5 µA 0.1 mA 0.7 mA 2 mV 2.5 µA 0.5 mA 1.1 mA Load regulation Voltage Current 2 mV 1 mA 2.5 mV 0.5 mA 1 mV 2 mA 2.5 mV 1 mA 2 mV 1 mA Line regulation Voltage Current 0.5 mV 0.5 mA 0.5 mV 0.5 mA 1 mV 0.25 mA 1 mV 0.25 mA 0.5 mV 0.5 mA Transient response time Less than 100 µs for the output to recover to its p revious level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) followi ng any step change in load current of up to 50% of the output c urrent rating of the supply

04 | Keysight | 6610C Series Single-Output, 40-50 W GPIB Power Supplies - Data Sheet Keysight Models: 6611C, 6612C, 6613C, 6614C, 6611C-J05 Top Side Rear 368.3 mm 14.5" 368.3 mm 14.5" 212.8 mm 8.4" 88.1 mm 3.5" Supplemental characteristics for all model numbers DC floating voltage: Output terminals can be floated up to ± 240 VDC maximum from chassis ground Remote sensing: Up to two volts dropped in each load lead. Add 2 mV to the voltage load regulation specification for each one volt change in the positive output lead due to load current change. Command processing time: Average time required for the output voltage to begin to change following receipt of digital date is 4 ms for the power supplies connected directly to the GPIB. Output programming response time: The rise and fall time (10/90% and 90/10%) of the output voltage is less t han 2 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 6 ms. GPIB interface capabilities: IEEE-488.2, SCPI command set, and 6610A/B Series programming compatibility Input power: (full load): 1.6 A, 100 W (6611C: 2.2 A, 120 W) Regulatory compliance: Complies with EMC directive 89/336/EEC (ISM 1B). Software driver: VXIplug&play Weight: 8.2 kg (18.16 lb) net; 10.6 kg (23.5 lb) shipping

05 | Keysight | 6610C Series Single-Output, 40-50 W GPIB Power Supplies - Data Sheet

Ordering information

Opt 100 87 to 106 VAC, 47 to 63 Hz Opt 120 104 to 127 VAC, 47 to 63 Hz Opt 220 191 to 233 VAC, 47 to 63 Hz Opt 230 207 to 253 VAC, 47 to 63 Hz Opt 760 Isolation and reversal relays Opt 87J Removes feet for use in rack system Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package. CD-ROM includes User’s Guide, Programming Guide, Service Manual and Quick Start Guide Opt 0B3 Printed service manual Accessories p/n 1494-0015 Rack slide kit E3663AC* Support rails for Keysight rack cabinets 1CM002A* Rack mount flange kit 88.1 mm H (2U), 1.5 inch hole space for side by side mounting of two units. Requires lock link kit (and support rails) 5061-9694 Lock link kit 1CM024A* Rack mount flange kit 88.1 mm H (2U), one bracket, one half-module bracket, and filler panel Application notes

10 Practical Tips You Need to Know About Your Power

Products, 5965-8239E

10 Hints for Using Your Power Supply to Decrease Test

Time, 5968-6359E Understanding Linear Power Supply Operation (AN1554), 5989-2291EN *Support rails required

06 | Keysight | 6610C Series Single-Output, 40-50 W GPIB Power Supplies - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2012 - 2014 Published in USA, August 2, 2014 5990-9301EN www.keysight.com myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) www.keysight.com/find/6610