6240030 CLARKE | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 16
Technical content
OPERATING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC10/23 -Rev 9 JUMPSTART MODEL NO: JS4000 PART NO: 6240030
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INTRODUCTION Thank you for purchasing this CLARKE Jump-start. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. Please keep these instructions in a safe place for future reference. SPECIFICATIONS Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice. Item Specification Weight 17 kg Dimensions (L x H x D) mm 345 x 390 x 190 Insulation Class Class II Max Output Current Starting 1100A Peak 2200A Battery Type Sealed re-chargeable lead-acid 12V/40AH Lighter Socket output 12V DC /1.9A for 20 hours Estimated engine starting capacity Up to 4.0 litres (diesel) Up to 6.0 litres (petrol) Working lamp Screw-in 12V/0.3Amp
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERAL SAFETY RULES 1. ALWA YS ensure when jump-starting that there is air circulating around the machine. 2. NEVER allow the negative and positive leads on this unit, to touch each other or to touch the same metal object. 3. Although the jump-start is water resistant and may be used outdoors, DO NOT leave it exposed to the elements. Avoid direct sunlight, direct heat, rain/moisture etc. 4. The JS4000 jump-start is desi gned for use with 12V systems. 5. DO NOT operate the jump-start if any of the cables are damaged. Consult your CLARKE dealer for repair or replacement of the parts. 6. DO NOT operate the jump-start if the case is damaged. Consult your CLARKE dealer or a qualified person for inspection and repair. 7. Ensure the vehicle battery posts an d battery clamps are perfectly clean before use. 8. When connecting the jump-start le ads to a battery, ensure the ON/OFF switch is OFF, and ALWAYS connect the RED, (positive’+’) output conductor to the UNEARTHED (+) battery terminal FIRST, then connect the BLACK, (negative) conductor to a suitable earthing point on the chassis, well away from any fuel lines. 9. To prevent the battery overheatin g and consequent damage, do not exceed our recommendations for the duration of jump starting. 10. ALWA YS wear suitable protective clothing and eye protection when working with lead-acid batteries. 11. The jump-start is NOT designed to be used as a replacement for a vehicle battery. 12. DO NOT attempt to BOOST CHARGE the jump-start's sealed battery. 13. NEVER allow the battery to become completely discharged. 14. NEVER jump-start the engine whilst the jump-start is being charged. 15. NEVER allow the cables to become wrapped around the operator or any other person. 16. NEVER attempt any repairs yourself. If you have a problem with the jump- start contact your local CLARKE dealer. 17. ALWA YS keep your body and clothing dry. Never work in damp area without adequate insulation against electric shock.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 18. ALWA YS store the jump-starter out of reach of children. 19. ALWA YS wear safety glasses when working with lead acid batteries. 20. If splashed by battery acid, immediately flush the area of the splash with clean water. If a burning sensation is felt or any blistering occurs, seek medical help. 21. If acid comes into contact with the eyes, flush the eyes with clean water continuously and seek medical help. ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility. ELECTRICAL SYMBOLS DISPLA YED The meanings of the safety markings and symbols which may be displayed on this product are shown below. Class II appliance without an earth connection Always read instructions before use Electrical hazard due to exposed live terminals Chemical Hazard from battery acid WARNING: ALL LEAD ACID BATTERIES GENERATE HYDROGEN GAS DURING NORMAL OPERATION. THIS PROCESS INCREASES DURING A PERIOD OF RAPID DISCHARGE, SUCH AS WHEN USING FOR JUMP - STARTING. WARNING: HYDROGEN GAS AND BATTERY ACID (SULPHURIC ACID) CAN BE: EXPLOSIVE, CORROSIVE TO SKIN, EYES AND HAIR, DAMAGING TO CLOTHING AND METALS, FLAMMABLE, POISONOUS TO BREATHE
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ELECTRICAL CONNECTIONS This product is provided with a 13 amp, 230 volt (50Hz), charging adaptor for connection to a standard, domestic electrical supply. Should the plug need changing at any time, ensure that a plug of identical specification is used. This product is of double insulated design. No earth conductor is provided. No earth conductor is provided. The two wires in the mains lead should be wired up in accordance with the following colour code: Blue — Neutral Brown — Live Connect the BROWN coloured cable to the plug terminal marked a letter “L”. Connect the BLUE coloured cable to the plug terminal marked a letter “N”. If the battery charger for this appliance is fitted with a plug which is moulded on to the electric cable (i.e. non-rewireable) please note: 1. The plug must be thrown away if it is cut from the electric cable. There is a danger of electric shock if it is subsequently inserted into a socket outlet. 2. Never use the plug without the fuse cover fitted. 3. Should you wish to replace the fu se cover, ensure that the correct replacement is used (as indicated by marking or colour code). 4. Replacement fuse covers can be obta ined from your local CLARKE dealer or most electrical stockists. FUSE RATING The fuse in the plug must be replaced with one of the same rating and this replacement must be ASTA approved to BS1362. If in any doubt, consult a qualified electrician. DO NOT attempt any electrical repairs yourself.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com COMPONENT IDENTIFICATION The JS4000 is a rechargable power supply which can be used to start a car in the event of a flat battery. The unit can also be used to power electrical appliances via a cigarette lighter type socket using the adaptor supplied. The unit also incorporates a built-in lamp and may be used as a stand alone light source. An audible warning will sound in the event of low battery voltage, or if the clamps are incorrectly fitted for jump starting (wrong polarity).
1 Positive Battery Connecting Lead to
connect to positive battery terminal
7 Voltage Meter to indicate the volt-
age level of the units battery.
2 Lamp to provide light for roadside
repairs or emergency situations.
8 Cigar Lighter Socket for use with
the cigar lighter adapter provided. 3 12 DC Socket connects the 230 Volt charger for mains charging. 9 Voltage Test Switch. Press to indi- cate the internal battery power level. 4 230 Volt Charger to charge the internal battery pack 10 Lamp ON/OFF Switch. Switches the lamp ON or OFF.
5 Cigar Lighter Adaptor complete
with 5 Amp fuse.
11 Negative Battery Connection Lead
to connect to the negative battery terminal.
6 ON/OFF Switch 12 Charging Light (red)
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INITIAL BATTERY CHARGING 1. Charge your jump-start battery be fore using it for the first time. 2. Recharge the jump-start battery afte r every occasion of use if possible, and thereafter, at least every 30 days. 3. Always avoid leaving your jump -start in a discharged state. FOLLOW THE ABOVE POINTS TO ENSURE MAXIMUM LIFE FROM THE BATTERY. Two means of charging the battery are provided: 1. Via a 230V mains electricity supply, using the mains adaptor, as shown. 2. Via a 12V supply using the vehicle cigar lighter adapter with cable and plug provided. NOTE: Using a 12V vehicle supply, the battery will not charge to maximum, but only to approx. 50% of its capacity. NOTE: A 5 amp fuse is fitted into the cigarette lighter plug adaptor, accessed by unscrewing the end cap of the adaptor. Take care not to loose the spring when unscrewing this cap. CHARGING USING THE 230V MAINS ADAPTOR 1. Plug the cable into the socket at the rear of the unit, then plug the adaptor into the mains supply and switch on. The red CHARGING light on the jump-start will come on to indicate charging is in progress. 2. Continue to charge until the RED charging light changes from red to green. It is important to note that this could take several days, dependant upon the state of charge of the battery. NOTE: Pressing the ‘TEST’ voltage test switch with the charger disconnected, will cause the REVERSE
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com needle on the voltage meter to indicate the state of charge of the battery. Once the charger is disconnected, it will be noted that the voltage will slowly settle back. This is quite normal and should not cause alarm. When the LED extinguishes, charging will automatically stop, indicating that the battery is fully charged. IMPORTANT: DO NOT allow the needle to enter the RED zone while pressing the test switch as this could damage the battery. CHARGING USING THE 12V ADAPTOR 1. Plug the jack plug into the charging so cket at the rear of the unit, then into the cigar lighter socket on the vehicle and start the engine. The red LED on the jump-start will indicate that charging is in progress. 2. Continue to charge until the “Interna l Battery Status” gauge registers ‘OK’ when the ‘TEST’ button is pressed, WITH THE CHARGING CURRENT DISCONNECTED. i.e. disconnect the cigar lighter adapter from the socket on the vehicle before pressing the TEST button. NOTE: We recommend that you use this system only when necessary, as prolonged use will reduce the life expectancy of the battery, due to the fact that this method can only charge the battery to approx. 50% of its capacity. NOTE: For maximum battery life, we strongly recommend that you maintain the battery in a fully charged state at all times. NOTE: If charging does not take place, check the green LED on the adapter. Ensure all connections are clean and free of grease etc.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com OPERATION Always carry out the following preliminary checks before connecting the jump-start to the car battery: Ensure the vehicle ignition and ALL ancillary equipment - lighting, radio etc, is switched off. Ensure the vehicle battery is rated at 12V and is not damaged in any way. Ensure the battery terminals are cl ean and the clamps are firm and secure. Remove any vehicle battery filler plugs and check the electrolyte level. If necessary, top up with distilled water. Ensure the area is well ventilated. Take great care not to touch the red positive (+) clamp against the black negative (-) clamp. 1. Ensure the ON/OFF switch is in the OFF position. 2. Connect the red positive (+ ) clamp to the positive (+) battery terminal first. Take care the clamp does not contact any moving parts or fuel lines. 3. Connect the black negative (-) clamp to the negative (-) battery terminal or to a suitable earthing point on the vehicle chassis ensuring the connections are firm and secure. If the polarity is incorrect, and audible warning will sound. Disconnect IMMEDIATELY and reverse the clamp connections. 4. Switch the Jump-start, then the vehi cle ignition ‘ON’ and leave in this condition FOR APPROX TWO MINUTES. (This will provide the vehicle battery with a short ‘boost’ charge to allow for easier starting). 5. Switch the ignition to ‘start ’, for NO MORE than 6 seconds.
- If the engine does not start, withi n this time, SWITCH OFF the ignition and wait for at least 3 minutes before trying again to prevent damage to the jumpstarter due to overheating before trying again. After this cooling off period, it is safe to resume trying to start the vehicle. 6. Once the vehicle has started, turn the jump-start ON/OFF switch OFF. WARNING: FAILURE TO FOLLOW THE INSTRUCTIONS BELOW AND THE SAFETY INSTRUCTIONS ON PAGES 3/4, MAY RESULT IN PERSONAL INJURY, DAMAGE TO THE VEHICLE, OR THE POSSIBILITY OF AN EXPLOSION
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 7. Once the engine is running, disconne ct the earthed clamp FIRST i.e. that connected to the chassis or Negative terminal etc, and return it to its storage position, then disconnect the Positive clamp from the battery terminal, and restore to its storage position. 8. After use, always recharge the jump -start. If the battery is allowed to remain in a discharged state, its life may be shortened. 9. Regularly check the charge level of th e battery by pressing the TEST push- button on the front panel. USING AS A 12VOLT POWER SUPPLY The unit has a cigar lighter type socket located on the side of the casing (see page 6), that allows connection via a standard DC connector to other DC electrical equipment. WARNING: Be Aware that a fully charged 12V battery can have an output of approx.13.5V. Consult the appliance handbook to ensure it is safe to operate from a 12V battery. The table below indicates the approx. operating time from a fully charged battery. ESTIMATED OPERATING PERIOD PROVIDED WARNING: IT IS POSSIBLE THAT SOME ELECTRONIC EQUIPMENT COULD BE DAMAGED BY JUMP STARTING. ALWAYS CHECK WITH THE CAR MANUFACTURER’S HANDBOOK TO DETERMINE WHAT PRECAUTIONS IF ANY SHOULD BE TAKEN. Estimated Use Electrical Appliance 30 hours Mobile phones 21 hours Radios, fans 12 hours Cam-corder, VCR, Spotlight 7 hours Electrical tools, bilge pump
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com MAINTENANCE Always inspect the jump-start before use to ensure the cables are in good condition and the clamps are clean and free from corrosion. If damaged they should be replaced. Keep the unit clean by wiping with a dry cloth. DO NOT use solvents as a cleaning agent. GENERAL CARE Keep the unit at HIGH or FULL CHARGE status at all times. Always turn the jump-start OFF during storage and store in an upright position, away from direct sunlight, moisture or sources of extreme heat or cold. NEVER attempt any repair unless your are a qualified technician. If you have a problem with the machine contact your local CLARKE dealer. Your CLARKE jump-start has been designed to give long and trouble free service. If, however, having followed the instructions in this booklet carefully, you encounter problems, take the unit to your local CLARKE dealer. REPLACING THE BATTERY 1. Unscrew and remove the self tapping sc rews securing the back cover. Lift off the cover to expose the battery and other components. 2. Lift out the battery fr om the battery compartment, and detach the heavy duty, and other cables, from the battery terminals. 3. Taking great care not to short acro ss the battery terminals, connect the RED heavy duty cable, and other cable with red sheath, to the battery terminal painted RED, and the black cables to the other battery terminal. 4. Gently slide the new battery into posi tion in its compartment, taking care not to damage the printed circuit board 5. Replace the back cove r and secure with the self tapping screws. CHANGING THE LIGHT BULB 1. Gently squeeze the sides of the lens bezel together, or very carefully use a screwdriver to disengage the clips at either side, and pull the lens and bezel out. 2. Unscrew and remove the burned ou t bulb and screw in a replacement. 3. Snap the lens and bezel back into place and replace the back cover.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com REPLACING THE 13 AMP PLUG Should the transformer’s 13 amp plug require changing, take note that transformer is DOUBLE INSULATED, i.e. NO earth lead. The new plug must be 13amp, BS1363 approved. Connect the Blue lead to the plug’s Neutral terminal and the Brown lead to the live terminal. IMPORTANT: The old, moulded plug MUST be thrown away. DO NOT RE-USE. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com COMPONENT PARTS No Description No Description 1H o u s i n g 13 Cigarette Cable - Negative 2L a b e l 14 Protective Cover
3 Working Light Holder 15 Cigarette Cable - Positive
4W o r k i n g L i g h t B a s e 16 Cigarette Cable 5W o r k i n g L i g h t B u l b 17 Adaptor
6 Working Light Mirror 18 Protector
7W o r k i n g L i g h t C o v e r 19 Switch
8 On/off Switch -1 20 PC Board
9 On/off Switch -2 21 Battery (2 x 20Ah)
10 Voltage Meter 22 Rear Housing
11 Connection Cable 23 Battery Retainer
12 F2G Booster Cable
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATIONS OF CONFORMITY - UKCA
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATIONS OF CONFORMITY - CE