5989-8853EN KEYSIGHT | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 37
Technical content
Power Products – October 2015 A guide to power product solutions to match your test and measurement needs Selection Guide
No surprises from Keysight – delivering high-quality power products for more than 50 years. Since power supplies are used in such a wide variety of applications, Keysi ght Technologies, Inc. offers a full line of DC and AC power supplies to meet your test requirements. Our famil y starts with high-value basic power supplies and goes up to high-performance produ cts. In addition, we have specialty power supplies and three modular power supplies to give you the le xibility you need in test system development. For whatever application or industr y you work in, Keysight power supplies offer excellent performance and high reliability to give y ou conidence when making your power supply purchase. Because Keysight knows how to make power sup plies.
03 | Keysight | Power Products – October 2015 - Selection Guide In this guide: Power Supply Categories / 4 Selecting the Right DC Power Supply / 5 - 8 DC Voltage and Current At a Glance / 9 - 10 DC Power Supply Details New E36100, E3600 and U8000 Series Basic Power Supplies / 11 – 6030 Series Basic Autoranging DC Power Supplies / 12 – N5700 and N8700 Series Basic DC Power Supplies / 13 – N8900 Series Autoranging System DC Power Supplies / 14 – 6600 Series High-Performance DC Power Supplies / 15 – B2961A/B2962A 6.5 Digit Low Noise Power Source / 16 – N6900 and N7900 Advanced Power System (APS) / 17 – N6700 Low-Proile Modular Power System / 18 – High-Power N6700 DC Power Modules / 18 – N6705B DC Power Analyzer / 19 – 66000 Modular Power System / 20 DC Electronic Loads / 21 AC Single-Phase Power Sources – AC6800 Series Basic AC Power Sources / 22 – 6800 Series AC Power Source/Analyzers / 22 Application-Speciic Power Products New N6780 Series Source/Measure Units / 23 – B2900A Series Precision Source/Measure Units / 24 – U2720 USB Modular Source Measure Units /25 – E5260A/E5270B Precision IV Analyzer/Source Monitor Unit Mainfr ame Series / 26 – B1500A Semiconductor Device Analyzer / 27 – B1505A Power Device Analyzer/Curve Tracer /28 – B1506A Power Device Analyzer for Circuit Design /29 – B1507A Power Device Capacitance Analyzer /30 – N6783A Application-Speciic Modules /31 – 66300 Mobile Communications DC Sources / 32 – E4360 Modular Solar Array Simulators / 33 New N8937APV and N8957APV Photovoltaic Array Simulators / 34 – New PA2201A IntegraVision Power Analyzer / 35
04 | Keysight | Power Products – October 2015 - Selection Guide Basic Affordable, quiet and stable power supplies for both manual and simple computer-controlled operation. The Keysight line of basic power suppl ies is optimized to provide DC power in applications where speed and accuracy are a low consideration. These power supplies are a high-value it for the bench an d in a system rack. Performance Speed, accuracy and advanced programming features make the performance power supplies the right choice when the DC power supply is a factor in test performance. With features such as DUT protection, fast programming times and downloadable V and I sequences, these DC power supplies can reduce your risk during test and system development. Specialty Sometimes it is best to have a power supply with unique capabilities that are tailored to a speciic application. For example, the Keysight 66300 Mobil e Communications DC Sources are designed to emulate the unique character- istics of a battery for mobile device testing and maintain those characte ristics even when using long load leads, such as in an ATE system. The Keysight E4360 Solar Array Simulator simulates solar panel I-V characteristics for sat ellite development and testing. Modular Keysight offers fully programmable power supplies in a modular format: the N6700 low-proile modular power system, N6705B DC power analyzer, and 66000 modular power system series. With this feature, you now have an extensive choice of power options—from basic through performance. Additionally, all modules interact in the same way at a single interface node , which simpliies system architecture and reduces cost when the test system inevitably changes. AC Sources Keysight provides a full line of basic and performance AC sources to help you test a variety of AC-powered devices. Basic sources provide reliable pow er while performance sources provide advanced measurements and waveform generation. DC Electronic Loads Electronic loads sink current and dissipate power in an accurate and control led manner. Connected to circuit under test, an electronic load provides a convenient way to vary the load on the circuit’s output in order to understand the circuit’s performance. Keysight offers two families of electron ic loads—a single output family and a modular, multiple output family. Power Supply Categories
05 | Keysight | Power Products – October 2015 - Selection Guide When you need just a basic power supply, it’s quite easy to pick the right one based on your voltage and current requirements. The voltage and current tables are found on pages 9 - 10. From there you can go to the product page(s) for more detail. When you have specialized requirements that need features such as source and measure, it is quite easy to select from a set of power supplies that are designed exactly for those requirements. Refer to page 23 for specialty power products. But when you have more complex requirements and you know the power supply is an important part of your test bench, where do you start and what do you need to consider? Selecting the Right DC Power Supply For Your Application Output Characteristics Use the following information to help select the features you need in a DC power supply. Then go to the product page(s) for more detail. Of course you need to select the right voltage and current, but there are other factors to consider when selecting a DC power supply for your applications. This guide gives a deinition of the feature, states why it’s important, and tells you how to use that feature when specifying the right power supply. In addition, the product families are listed so you can quickly see which product best its your application. With that information, you can go to the product pages for detailed speciications. LOW ripple and noise <10 mVp-p MEDIUM ripple and noise 5–500 mVp-p Ripple and noise Use the ripple and noise speciication to determine what, if any, affects these variations will have on your circuit or device. Ideally, an output is free from any variations in voltage. In practice, there are periodic variations, called ripple, and random variations, called noise. Typically speciied as either Vrms or Vp-p, the most useful spec is Vp-p. With Vp-p you will know the maximum variation away from the DC setpoint. 6611C-55A 66309B-32A B2961A-62A E3600 Series N6751A-66A N6781A-84A N6900 Series N7900 Series U8031A-32A p15 p32 p16 p11 p18 p23 p17 p17 p11 66101A-06A 6671A-92A E36100 Series N5700 Series N6731B-46B N6773A-77A N6785A-86A N8700 Series N8900 Series U8001A-02A p20 p15 p11 p13 p18 p18 p23 p13 p14 p11 HIGH accuracy <0.03% MEDIUM accuracy >0.05% Programming Accuracy Use programming accuracy to determine if the power supply can produce a voltage and current within the precision needed by your device. Programming accuracy is a measure of how closely the output will be to the setpoint. Spec - iied as a percent of output plus an offset, you can calculate whether or not the power supply has the precision required. In addition, many power supplies have built-in voltmeters and ammeters to measure its output.
6620 Series
6600 Series
66100 Series
06 | Keysight | Power Products – October 2015 - Selection Guide Output Characteristics Continued FAST output response <15 ms MEDIUM output response <200 ms Output Response Use this speciication to select the power supply that is fast enough for your application. When the setpoint changes it will take some time before the output reaches the setting. How fast it reaches the setpoint is a result of its regulation design and the output bandwidth. The speciications are typically for a voltage change from 10% to 90% of its rated output or a load change of 50% to 100%. 6610A-55A
66300 Series
Specify power supplies with the appropriate hardware and software interface for computer control. Many DC power supplies have both manual and computer control. Some are only manually controlled. Hardware interfaces for DC power supplies include GPIB, USB, and LAN (LXI Core). Software interfaces include the SCPI language and drivers such as IVI-C, IVI-COM, and VXIplug&play. E3620A-30A U8000 Series p11 p11 All others WITH analog input WITHOUT analog input Analog Voltage Control Signal Specify a power supply with an analog input whenever you need to amplify the power or need to track an analog voltage. Some power supplies provide an analog voltage control input to cause the voltage output to follow this input. Essentially, it ampliies the power since the power supply can provide current up to its rated maximum.
6640 Series
6650 Series
Measure V & I Output Specify power supplies with built-in measurements whenever you need to check the actual voltage and current. Many power supplies have a built in voltmeter and ammeter to read back their own output. The measurements can be displayed on the front panel or queried by a computer connected to the interface. These measurements are particularly useful in computer- controlled systems. Measure- ment (or read back) accuracy is speciied as a percent of full scale plus an offset. All others
07 | Keysight | Power Products – October 2015 - Selection Guide mfr = mainframes for the E4360, N6700, N6707B, N6705B and 66000 modular power supplies Packaging QUARTER rack MEDIUM output response <200 ms FULL rack Physical Size Use the size speciication to match bench or system use. Keysight power supplies have stan - dard EIA 19-inch rack dimensions. The width is either half rack width or full rack width while the height ranges from 1U to 5U (1.75 in to 8.57 in). While any size can be used on the bench or in a system rack, the half rack width is generally better for bench applications while the full rack width works well in system racks. Of special note is the 1U height of the N5700 and N6700 Series. E36100 Series p11 6610 Series B2961A-62A E3600 Series U8000 Series p15 p16 p11 p11 All others FRONT terminals REAR terminals Front or Rear Output Terminals Select the model with its output terminals in the best location for your application on either the bench or in a system rack. The output terminals can be located on the front of the power supply or the rear. System and high-current power supplies have their outputs located on the rear panel while bench and some low current power supplies have outputs on the front. 6610A-55A B2961A-62A E3620A-30A E36100 Series N6705B U8000 Series p15 p16 p11 p11 p19 p11 All others SINGLE outputs MULTIPLE outputs Number of Outputs Specify multiple outputs per unit when you need to save space on the bench or in a system rack. Keysight power supplies are con - igured with 1 to 8 outputs per unit. Multiple output power supplies can save space on the bench or in a rack. Of special note are the 66000 and N6700 modular mainframes that can hold up to 8 and 4 modules respectively. All others 66000 mfr
08 | Keysight | Power Products – October 2015 - Selection Guide Specialty WITH DUT protection WITHOUT DUT protection DUT protection Select power supplies with DUT protection whenever your load may be damaged by over voltage or over current. Many power supplies can be set for a maximum voltage and current to protect the device under test (DUT). When set, the power supply will limit the voltage and/or current regardless of the load. This feature provides a margin of safety when something goes wrong. All others E3620A-31A p11 WITH LIST memory WITHOUT LIST memory Computer Interface Specify power supplies with the appropriate hardware and software interface for computer control. Many DC power supplies have both manual and computer control. Some are only manually controlled. Hardware interfaces for DC power supplies include GPIB, USB, and LAN (LXI Core). Software interfaces include the SCPI language and drivers such as IVI-C, IVI-COM, and VXIplug&play.
66000 Series
Output disconnect or polarity reversal Select power supplies with optional output relays when your application requires power to be physically disconnected from the device. Automatic connect, disconnect, and polarity reversal can be accomplished with programma - ble output relays. By doing so, you will eliminate an external relay and have an easy method to programmatically actuate the relay.
6630 Series
09 | Keysight | Power Products – October 2015 - Selection Guide Model numbers Page Outputs 5 to 9 V 12 to 20 V 21 to 40 V 6611C-14C 15 1 0-8 V, 5 A (6611C) 0-20 V, 2 A (6612C) 6621A-24A, 6627A 15 2 to 4 0-7 V, 5 A or 0-20 V, 2 A 0-7 V, 10 A or 0-20 V, 4 A 0-20 V, 2 A or 0-50 V, 0.8 A 6625A-26A, 6628A-29A 15 2 to 4 0-7 V, 15 mA or 0-50 V, 500 mA 0-16 V, 200 mA or 0-50 V, 1 A 6631B-34B 15 1 0-8 V, 10 A (6631B) 0-20 V, 5 A (6632B) 6641A-45A 15 1 0-8 V, 20 A (6641A) 0-20 V, 10 A (6642A) 0-35 V, 6 A (6643A) 6651A-55A 15 1 0-8 V, 50 A (6651A) 0-20 V, 25 A (6652A) 0-35 V, 15 A (6653A) 6671A-75A 15 1 0-8 V, 220 A (6671A) 0-20 V, 100 A (6672A) 0-35 V, 60 A (6673A) 6680A-84A 15 1 0-5 V, 875 A (6680A) 0-8 V, 580 A (6681A) 0-21 V, 240 A (6682A) 0-32 V, 160 A (6683A) 0-40 V, 128 A (6684A) 6690A-92A 15 1 0-15 V, 440 A (6690A) 0-30 V, 220 A (6691A) 66001A-6A 19 1 to 8* 0-8 V, 16 A (66601A) 0-20 V, 7.5 A (66602A) 0-20, 5 A (66603A) 0-35, 4.5 A (66603A) 66309B-32A 33 1 to 2 0-15 V, 3 A (all 663xx) E36102A-06A 11 1 0-6V, 5A (E36102A) 0-20V, 2A (E36103A) 0-35V, 1A (E36104A) E3620A 11 2 0-25 V, 1 A (E3620A x2) E3630A-31A 11 3 0-6 V, 2.5 (E3630A x1) 0-6 V, 5 A (E3631A x1) 0-±20 V, 0.5 A (E3630A x2) 0-±25 V, 1 A (E3631A x2) E3632A-34A 11 1 0-8 V, 20 A (E3633A r1) 0-15 V, 7 A (E3632A r1) 0-20 V, 10 A (E3633A r2) 0-30 V, 4 A (E3632A r2) 0-25 V, 7 A (E3634A r1) E3640A-45A 11 1 0-8 V, 3 A (E3640A r1) 0-8 V, 5 A (E3642A r1) 0-8 V, 8 A (E3644A r1) 0-20 V, 1.5 A (E3640A r2) 0-20 V, 2.5 A (E3642A r2) 0-20 V, 4 A (E3644A r2) 0-35 V, 0.8 A (E3641A r1) 0-35 V,1.4 A (E3643A r1) 0-35 V, 2.2 A (E3645A r1) E3646A-49A ** 11 2 0-8 V, 3 A (E3646A r1) 0-8 V, 5 A (E3648A r1) 0-20 V, 1.5 A (E3646A r2) 0-20 V, 2.5 A (E3648A r2) 0-35 V, 0.8 A (E3647A r1) 0-35 V, 1.4 A (E3649A r1) N5741A-52A 13 1 0-6 V, 100 A (N5741A) 0-8 V, 90 A (N5742A) 0-12.5 V, 60 A (N5743A) 0-20 V, 38 A (N5744A) 0-30 V, 25 A (N5745A) 0-40 V, 19 A (N5746A) N5761A-72A 13 1 0-6 V, 180 A (N5761A) 0-8 V, 165 A (N5762A) 0-12.5 V, 120 A (N5763A) 0-20 V, 76 A (N5764A) 0-30 V, 50 A (N5765A) 0-40 V, 38 A (N5766A) N6731B-36B 17 1 to 4* 0-5 V, 10 A (N6731B) 0-8 V, 6.25 A (N6732B) 0-20 V, 2.5 A (N6733B) 0-35 V, 1.5 A (N6734B) N6741B-46B 17 1 to 4* 0-5 V, 20 A (N6741B) 0-8 V, 12.5 A (N6742B) 0-20 V, 5 A (N6743B) 0-35 V, 3 A (N6744B) N6751A-52A N6761A-62A N6773A-77A 17 1 to 4* 0-20 V, 15 A (N6773A) 0-35 V, 8.5 A (N6774A) N6753A-56A N6763A-66A 17 2* 0-20 V, 50 A (N6753A) 0-20 V, 50 A (N6755A) 0-20 V, 50 A (N6763A) 0-20 V, 50 A (N6765A) N6781A-86A 23 1 to 4* 0-6 V, +3 to-2 A (N6783A-MFG) 0-8 V, +3 to-2 A (N6783A-BAT) 0-20 V, ±3 A (N6781A-82A) N6950A-52A, N6970A-72A N7950A-52A, N7970A-72A 0-9 V, 100 A (N69/N7950A) 0-9 V, 200 A (N69/N7970A) 0-20 V, 50 A (N69/N7951A) 0-20 V, 100 A (N69/N7971A) 0-40 V, 25 A (N69/N7952A) 0-40 V, 50 A (N69/N7972A) N8731A-42A 13 1 0-8 V, 400 A (N8771A) 0-10 V, 300 A (N8732A) 0-15 V, 220 A (N8733A) 0-20 V, 165 A (N8734A) 0-30 V, 110 A (N8735A) 0-40 V, 85 A (N8736A) N8754A-62A 13 1 0-20 V, 250 A (N8754A) 0-30 V, 170 A (N8755A) 0-40 V, 125 A (N8756A) U8001A 11 1 0-30 V, 3 A U8002A 11 1 0-30 V, 5 A U8031A 11 3 0-30 V, 6 A (Output 1 & 2); 5 V, 3 A (Output 3) * Power modules that require a modular mainframe (66000 Series, N6700 Ser ies, N6705) ** Dual range power supplies; r1 denotes range 1; r2 denotes range 2 DC Voltage and Current At a Glance Voltage ranges: 5 V to 40 V
10 | Keysight | Power Products – October 2015 - Selection Guide DC Voltage and Current At a Glance, continued Voltage ranges: 50 V to 1500 V Model numbers Page Outputs 50 to 80 V 100 to 210 V 300 to 1500 V 6611C-14C 15 1 0-50 V, 1 A (6613C) 0-100 V, 0.5 A (6614C) 6621A-24A, 6627A 15 2 to 4 0-20 V, 4 A or 0-50 V, 2 A 6631B-34B 15 1 0-50 V, 2 A (6633B) 0-100 V, 1 A (6634B) 6641A-45A 15 1 0-60 V, 3.5 A (6644A) 0-120 V, 1.5 A (6645A) 6651A-55A 15 1 0-60 V, 9 A (6654A) 0-120 V, 4 A (6655A) 6671A-75A 15 1 0-60 V, 35 A (6674A) 0-120 V, 18 A (6675A) 6690A-92A 15 1 0-60 V, 110 A (6692A) 66101A-6A 20 1 to 8* 0-60 V, 2.5 A (66104A) 0-120 V, 1.25 A (66105A) 0-200 V, 0.75 A (66106A) B2961A-62A 16 1 to 2 0-±210 V, ±0.105 A to ±3 A 0-±210 V, ±0.105 A to ±3 A E36102A -06A 11 1 0-60V, 0.6A (E36105A) 0-100V, 0.4A (E36106A) E3632A-34A 11 1 0-50 V, 4 A (E3634A r2) E3640A-45A 11 1 0-60 V, 0.5 A (E3641A r2) 0-60 V, 0.8 A (E3643A r2) 0-60 V, 1.3 A (E3645A r2) E3646A-49A ** 11 2 0-60 V, 0.5 A (E3647A r2) 0-60 V, 0.8 A (E3649A r2) E4361A-62A 33 1 to 2* 0-65 V, 8.5 A (E4361A) 0-130 V, 5 A (E4362A) N5741A-52A 13 1 0-60 V, 12.5 A (N5747A) 0-80 V, 9.5 A (N5748A) 0-100 V, 7.5 A (N5749A) 0-150 V, 5 A (N5750A) 0-300 V, 2.5 A (N5751A) 0-600 V, 1.3 A (N5752A) N5761A-72A 13 1 0-60 V, 25 A (N5767A) 0-80 V, 19 A (N5768A) 0-100 V, 15 A (N5769A) 0-150 V, 10 A (N5770A) 0-300 V, 5 A (N5771A) 0-600 V, 2.6 A (N5772A) N6731B-36B 18 1 to 4* 0-60 V, 0.8 A (N6735B) 0-100 V, 0.5 A (N6736B) N6741B-46B 18 1 to 4* 0-60 V, 1.6 A (N6745B) 0-100 V, 1 A (N6746B) N6751A-52A N6761A-62A N6773A-77A 18 1 to 4* 0-50 V, 5 A (N6751A) 0-50 V, 10 A (N6752A) 0-50 V, 1.5 A (N6761A) 0-50 V, 3 A (N6762A) 0-60 V, 5 A (N6775A) 0-100 V, 3 A (N6776A) 0-150 V, 2 A (N6777A) N6753A-56A N6763A-66A 18 2* 0-60 V, 20 A (N6754A) 0-60 V, 17 A (N6756A) 0-60 V, 20 A (N6764A) 0-60 V, 17 A (N6766A) N6953A-54A N6973A-77A N7953A-54A N7973A-77A 0-60 V, 16.7 A (N69/N7953A) 0-60 V, 33.3 A (N69/N7973A) 0-80 V, 12.5 A (N69/N7954A) 0-80 V, 25 A (N69/N7974A) 0-120 V, 16.7 A (N69/N7976A) 0-160 V, 12.5 A (N69/N7977A) N8731A-42A 13 1 0-60 V, 55 A (N8737A) 0-80 V, 42 A (N8738A) 0-100 V, 33 A (N8739A) 0-150 V, 22 A (N8740A) 0-300 V, 11 A (N8741A) 0-600 V, 5.5 A (N8742A) N8754-62A 13 1 0-60 V, 85 A (N8757A) 0-80 V, 42 A (N8738A) 0-100 V, 50 A (N8759A) 0-150 V, 34 A (N8760A) 0-300 V, 17 A (N8761A) 0-600 V, 8.5 A (N8762A) N8920A-57A N8937APV/57APV 0-80 V, 170 A (N8920A/40A) 0-80 V, 340 A (N8925A/45A) 0-80 V, 510 A (N8931A/51A) 0-200 V, 70 A (N8921A/41A) 0-200 V, 140 A (N8926A/46A) 0-200 V, 210 A (N8932A/52A) 0-500 V, 30 A (N8923A/43A) 0-500 V, 60 A (N8928A/48A) 0-500 V, 90 A (N8934A/54A) 0-750 V, 20 A (N8924A/44A) 0-750 V, 40 A (N8929A/49A) 0-750 V, 60 A (N8935A/55A) 0-1000 V, 30 A (N8930A/50A) 0-1500 V, 30 A (N8937A/57A/APV) U8032A 11 3 0-60 V, 3 A (Output 1 & 2);
5 V, 3 A (Output 3)
- Power modules that require a modular mainframe (66000 Series, N6700 Ser ies, N6705) ** Dual range power supplies; r1 denotes range 1; r2 denotes range 2
11 | Keysight | Power Products – October 2015 - Selection Guide When you need reliable power with minimal features, you can rely on the NEW E36100, E3600 and U8000 Series basic power supplies. NEW E36100 Series BASIC Power Supplies Compact bench supplies The NEW E36100 series features a high-contrast OLED display that is viewable from any angle, modern I/O connectivity, and saves valuable space with its compact size (2U, ¼ rack). – Up to 100V, up to 5A – Clean and stable DC power – Excellent programming and read - back accuracy – LAN (LXI Core), and USB E3600 and U8000 Basic Power Supplies The E3600 Series offers an extensive choice of voltages, programmability, and number of outputs. The U8000 Series offers more afford- able DC power and provides features typical only found in programmable power supplies (like output sequenc- ing, save/recall, and more). – 30 W to 375 W outputs, 6 V to 60 V, and 0.5 A to 20 A – Single- to triple-output models – Low noise, linear regulation – Dual range outputs to provide more current at lower voltage settings NEW E36100, E3600 and U8000 Series Basic Power Supplies Essential features for a tight budget E3631A Power (W) Maximum V (V) Maximum I (A) NEW E36102A 30 6 5 1 1 LAN, USB 10 1 ¼ RU w x 2 RU h NEW E36103A 40 20 2 1 1 30 1 NEW E36104A 35 35 1 1 1 60 2 NEW E36105A 36 60 0.6 1 1 100 3 NEW E36106A 40 100 0.4 1 1 150 6 E3620A 50 25 V / 25 V* 1 A / 1 A* 2 1 No 1.5 10 ½ RU w x 2 RU hE3630A 35 6 V / +20 V / - -20 V* 2.5 A / 0.5 A / 0.5 A* 3 1 1.5 10 E3631A 80 6 V / +25 V / --25 V 5 A / 1 A / 1 A 3 1 GPIB 2 1.5 ½ RU w x 3 RU h E3632A 120 15 V r1 / 30 V r2 7 A r1 / 4 A r2 1 2 2 1 E3633A 200 8 V r1 / 20 V r2 20 A r1 / 10 A r2 1 2 3 1 E3634A 200 25 V r1 / 50 V r2 7 A r1 / 4 A r2 1 2 3 3 E3640A 30 8 V r1 / 20 V r2 3 A r1 / 1.5 A r2 1 2 GPIB 5 5 ½ RU w x 2 RU h E3641A 30 35 V r1 / 60 V r2 0.8 A r1 / 0.5 A r2 1 2 8 5 E3642A 50 8 V r1 / 20 V r2 5 A r1 / 2.5 A r2 1 2 5 5 E3643A 50 35 V r1 / 60 V r2 1.4 A r1 / 0.8 A r2 1 2 8 5 E3644A 80 8 V r1 / 20 V r2 8 A r1 / 4 A r2 1 2 5 5 E3645A 80 35 V r1 / 60 V r2 2.2 A r1 / 1.3 A r2 1 2 8 5 E3646A 60 8 V r1 / 20 V r2 3 A r1 / 1.5 A r2 2 2 GPIB 5 5 ½ RU w x 3 RU h E3647A 60 35 V r1 / 60 V r2 0.8 A r1 / 0.5 A r2 2 2 8 5 E3648A 100 8 V r1 / 20 V r2 5 A r1 / 2.5 A r2 2 2 5 5 E3649A 100 35 V r1 / 60 V r2 1.4 A r1 / 0.8 A r2 2 2 8 5 U8001A 90 30 3 1 1 No 12 10 ½ RU w x 2 RU hU8002A 150 30 5 1 1 12 10 U8031A 375 30 6 3 1 No 10 10 ½ RU w x 4 RU hU8032A 375 60 3 3 1 10 10 Model Size** Basic Program. or meter res. mV * Output 1 / Output 2 / Output 3 ** NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is e ither 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For example : a 3 RU h has a height of 5.25” (133.3 mm) Number of outputsNumber of rangesComputer interfaceRipple and noise mVp-p E36100 Series
12 | Keysight | Power Products – October 2015 - Selection Guide The 6030 Series basic power supplies offer autoranging outputs that give you maximum power at a variety of operating voltages. This enables you to use one power supply to do the job of multiple power supplies, saving rack space and reducing your system complexity. – 240 W to 1200 W outputs, up to
500 V, and up to 120 A
– Built-in measurements and advance programming features simplify system design – Full protection from over voltage and over current – Computer control via GPIB
6030 Series Basic Autoranging DC Power Supplies
Autoranging to do the job of multiple power supplies Power (W)Maximum V (V)Maximum I (A)Number of outputsNumber of ranges 6030A 1200 200 17 1 Autoranging 50 0.035 + 145 2 Full RU w x 3 RU h6031A 1064 20 120 1 Autoranging 50 0.035 + 15 2 6032A 1200 60 50 1 Autoranging 40 0.035 + 40 2 6033A 242 20 30 1 Autoranging 30 0.035 + 9 1 ½ RU w x 4 RU h 6035A 1050 500 5 1 Autoranging 160 0.25 + 400 5 Full RU w x 3 RU h 6038A 240 60 10 1 Autoranging 30 0.035 + 40 1 ½ RU w x 4 RU h Model Size* Basic Transient response, msProgramming accuracy % + mV * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is eit her 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For example : a 3 RU h has a height 6032A I1 I2 I3 V2Volts Autoranging Output Amps Ripple and noise mVp-p
13 | Keysight | Power Products – October 2015 - Selection Guide Power (W)Maximum V (V) Maximum I (A) Programming accuracy % + mVModel Size* Basic Transient response (ms) N8731A 3200 8 400 1 1 60 0.05 + 4 < 1 Full RU w x
2 RU h
N8732A 3300 10 330 1 1 60 0.05 + 5 < 1 N8733A 3300 15 220 1 1 60 0.05 + 7.5 < 1 N8734A 3300 20 165 1 1 60 0.05 + 10 < 1 N8735A 3300 30 110 1 1 60 0.05 + 15 < 1 N8736A 3400 40 85 1 1 60 0.05 + 20 < 1 N8737A 3300 60 55 1 1 60 0.05 + 30 < 1 N8738A 3360 80 42 1 1 80 0.05 + 40 < 1 N8739A 3300 100 33 1 1 100 0.05 + 50 < 1 N8740A 3300 150 22 1 1 100 0.05 + 75 < 2 N8741A 3300 300 11 1 1 300 0.05 + 150 < 2 N8742A 3300 600 5.5 1 1 500 0.05 + 300 < 2 N8754A 5000 20 250 1 1 75 0.025 + 15 < 1 Full RU w x N8755A 5100 30 170 1 1 75 0.025 + 22.5 < 1 N8756A 5000 40 125 1 1 75 0.025 + 30 < 1 N8757A 5100 60 85 1 1 75 0.025 + 45 < 1 N8758A 5200 80 65 1 1 100 0.025 + 60 < 1 N8759A 5000 100 50 1 1 100 0.025 + 75 < 1 N8760A 5100 150 34 1 1 120 0.025 + 112.5 < 2 N8761A 5100 300 17 1 1 300 0.025 + 225 < 2 N8762A 5100 600 8.5 1 1 500 0.025 + 450 < 2 N5700 Series and N8700 Series Basic DC Power Supplies Space-saving basic power with modern interfaces * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is eit her 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For exampl e: a 3 RU h has a height of 5.25” (133.3 mm) Basic N5749A: front/back Now get up to 5200 W in a compact, 2U package with the N8700 Series or up to 1560 W in a compact, 1U package with the N5700 Series. Both series offers solid performance and a variety of basic and enhanced capabilities. – Remote programming via GPIB, LAN and USB interfaces with the SCPI command set (drivers available) – Analog control and monitoring of output voltage and current – Connect multiple supplies in parallel or series for greater output current or voltage respectively – Built-in measurements – Front panel control and advanced programmable
features
– Built-in protection features such as OVP, OCP, UVL, and OTP – LXI Core compliant N8731A: front/back Number of outputsNumber of rangesRipple and noise mVp-p N5741A 600 6 100 1 1 60 0.5 + 3 ≤ 1.5 Full RU w x
1 RU h
N5742A 720 8 90 1 1 60 0.5 + 4 ≤ 1.5 N5743A 750 12.5 60 1 1 60 0.5 + 6.25 ≤ 1.5 N5744A 760 20 38 1 1 60 0.5 + 10 ≤ 1 N5745A 750 30 25 1 1 60 0.5 + 15 ≤ 1 N5746A 760 40 19 1 1 60 0.5 + 20 ≤ 1 N5747A 750 60 12.5 1 1 60 0.5 + 30 ≤ 1 N5748A 760 80 9.5 1 1 80 0.5 + 40 ≤ 1 N5749A 750 100 7.5 1 1 80 0.5 + 50 ≤ 1 N5750A 750 150 5 1 1 100 0.5 + 75 ≤ 2 N5751A 750 300 2.5 1 1 150 0.5 + 150 ≤ 2 N5752A 780 600 1.3 1 1 300 0.5 + 300 ≤ 2 N5761A 1080 6 180 1 1 60 0.5 + 3 ≤ 1.5 Full RU w x N5762A 1320 8 165 1 1 60 0.5 + 4 ≤ 1.5 N5763A 1500 12.5 120 1 1 60 0.5 + 6.25 ≤ 1.5 N5764A 1520 20 76 1 1 60 0.5 + 10 ≤ 1 N5765A 1500 30 50 1 1 60 0.5 + 15 ≤ 1 N5766A 1520 40 38 1 1 60 0.5 + 20 ≤ 1 N5767A 1500 60 25 1 1 60 0.5 + 30 ≤ 1 N5768A 1520 80 19 1 1 80 0.5 + 40 ≤ 1 N5769A 1500 100 15 1 1 80 0.5 + 50 ≤ 1 N5770A 1500 150 10 1 1 100 0.5 + 75 ≤ 2 N5771A 1500 300 5 1 1 150 0.5 + 150 ≤ 2 N5772A 1560 600 2.6 1 1 300 0.5 + 300 ≤ 2
14 | Keysight | Power Products – October 2015 - Selection Guide N8900 Series Autoranging System DC Power Supplies High-power, autoranging output does the job of multiple supplies The N8900 Series autoranging DC power supplies provide unprecedented lexibility by offering a wide range of voltage and current combinations at full power. Just one N8900 does the job of multiple power supplies! It’s like having many power sup- plies in one! – Up to 1500 V, up to 510 A – 5 kW, 10 kW and 15 kW models in a small 3U package – Easily parallel to create “one” power supply with > 100 kW of power – Protection from over-voltage, over-current and over-temperature – Control via GPIB, USB, LAN (LXI Core), and analog programming Power (W)Maximum V (V)Maximum I (A)Model Size* Basic Transient response (ms) N8940A 5000 80 170 1 1 200 ≤ 80 ≤ 1.5 400 Full RU w x
3 RU h
N8941A 5000 200 70 1 1 300 ≤ 200 ≤ 1.5 400 N8943A 5000 500 30 1 1 350 ≤ 500 ≤ 1.5 400 N8944A 5000 750 20 1 1 800 ≤ 750 ≤ 1.5 400 N8945A 10000 80 340 1 1 200 ≤ 80 ≤ 1.5 400 N8946A 10000 200 140 1 1 300 ≤ 200 ≤ 1.5 400 N8948A 10000 500 60 1 1 350 ≤ 500 ≤ 1.5 400 N8949A 10000 750 40 1 1 800 ≤ 750 ≤ 1.5 400 N8950A 10000 1000 30 1 1 800 ≤ 1000 ≤ 1.5 400 N8951A 15000 80 510 1 1 200 ≤ 80 ≤ 1.5 400 N8952A 15000 200 210 1 1 300 ≤ 200 ≤ 1.5 400 N8954A 15000 500 90 1 1 350 ≤ 500 ≤ 1.5 400 N8955A 15000 750 60 1 1 800 ≤ 750 ≤ 1.5 400 N8957A 15000 1500 30 1 1 1000 ≤ 1500 ≤ 1.5 400 * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is ei ther 1/2 or full. The height is in number of rack units which are 1. 75” (44.4 mm) each. For example: a 3 RU h has a hei ght of 5.25” (133.3 mm) Basic Number of outputsNumber of rangesRipple and noise mVp-pProgramming accuracy 0.1% mV AC Input Voltage (VAC) N8920A 5000 80 170 1 1 200 ≤ 80 ≤ 1.5 208 Full RU w x N8921A 5000 200 70 1 1 300 ≤ 200 ≤ 1.5 208 N8923A 5000 500 30 1 1 350 ≤ 500 ≤ 1.5 208 N8924A 5000 750 20 1 1 800 ≤ 750 ≤ 1.5 208 N8925A 10000 80 340 1 1 200 ≤ 80 ≤ 1.5 208 N8926A 10000 200 140 1 1 300 ≤ 200 ≤ 1.5 208 N8928A 10000 500 60 1 1 350 ≤ 500 ≤ 1.5 208 N8929A 10000 750 40 1 1 800 ≤ 750 ≤ 1.5 208 N8930A 10000 1000 30 1 1 800 ≤ 1000 ≤ 1.5 208 N8931A 15000 80 510 1 1 200 ≤ 80 ≤ 1.5 208 N8932A 15000 200 210 1 1 300 ≤ 200 ≤ 1.5 208 N8934A 15000 500 90 1 1 350 ≤ 500 ≤ 1.5 208 N8935A 15000 750 60 1 1 800 ≤ 750 ≤ 1.5 208 N8937A 15000 1500 30 1 1 1000 ≤ 1500 ≤ 1.5 208 Max Voltage (V) N89201A 208 N8931A 80 3060 A N8932A 200 1260 A N89202A 208 N8934A 500 540 A N8935A 750 360 A N8937A 1500 180 A N89401A 400 N8951A 80 3060 A N8952A 200 1260 A N89402A 400 N8954A 500 540 A N8955A 750 360 A N8957A 1500 180 A Rack Max System Current (A) NEW N8900 Series Pre- wired Rack Systems Up to 90 kW – Reduced system assembly and design time – Prewired control of up to six 15-kW N8900 power supplies (30 to 90 kW) – Control of the system as if it were one high-power supply, using the N8900 Series power supplies’ smart paralleling capability – LAN (LXI Core), USB, and GPIB I/O all standard AC input voltage (VAC)Power supply model
15 | Keysight | Power Products – October 2015 - Selection Guide The 6600 Series high-performance power supplies are designed to meet your most demanding requirements. With an exten - sive feature set, the 6600 Series can help you reduce test time and simplify your test system design. – 40 W to 6600 W outputs, up to 120 V, and up to 875 A – Fast, low-noise outputs increase your test throughput – Extensive programming capability for lexible system design – Built-in measurements and advance programming features simplify system design – Computer control via GPIB
6600 Series High-Performance DC Power Supplies
High-performance when the power supply matters to test 6680A 6623A 6631B Power (W) Maximum V (V) Maximum I (A) Programming accuracy % + mV6611C 40 8 5 1 1 3 0.05 + 5 < 100 ½ RU w x 6612C 40 20 2 1 1 3 0.05 + 10 < 100 6613C 50 50 1 1 1 4 0.05 + 20 < 100 6614C 50 100 0.5 1 1 5 0.05 + 50 < 100 6621A 80 20 / 7 4 / 10 2 2 3 0.06 + 19 < 75 Full RU w x 6622A 100 20 / 50 4 / 2 2 2 3 0.06 + 50 < 75 6623A 80 20 / 50 / 20* 5 / 2 / 10* 3 2 3 0.06 + 50 < 75 6624A 40 20 / 20 / 50 / 50* 5 / 5 / 2 / 2* 4 2 3 0.06 + 50 < 75 6627A 40 50 2 4 2 3 0.06 + 50 < 75 6625A 40 50 / 50* 0.5 / 2* 2 2 3 0.016 + 10 < 75 Full RU w x 6626A 50 50 / 50 / 50 / 50* 0.5 / 0.5 / 2 / 2* 4 2 3 0.016 + 10 < 75 6628A 50 50 2 2 2 3 0.016 + 10 < 75 6629A 50 50 2 4 2 3 0.016 + 10. < 75 6631B 80 8 10 1 1 3 0.05 + 5 < 100 Full RU w x 6632B 100 20 5 1 1 3 0.05 + 10 < 100 6633B 100 50 2 1 1 3 0.05 + 20 < 100 6634B 100 100 1 1 1 3 0.05 + 50 < 100 6641A 160 8 20 1 1 3 0.06 + 5 < 100 Full RU w x 6642A 200 20 10 1 1 3 0.06 + 10 < 100 6643A 210 35 6 1 1 4 0.06 + 15 < 100 6644A 210 60 3.5 1 1 5 0.06 + 26 < 100 6645A 180 120 1.5 1 1 7 0.06 + 51 < 100 6651A 400 8 50 1 1 3 0.06 + 5 < 100 Full RU w x 6652A 500 20 25 1 1 3 0.06 + 10 < 100 6653A 525 35 15 1 1 4 0.06 + 15 < 100 6654A 540 60 9 1 1 5 0.06 + 26 < 100 6655A 480 120 4 1 1 7 0.06 + 51 < 100 6671A 1760 8 220 1 1 7 0.04 + 8 < 900 Full RU w x 6672A 2000 20 100 1 1 9 0.04 + 20 < 900 6673A 2100 35 60 1 1 9 0.04 + 35 < 900 6674A 2100 60 35 1 1 11 0.04 + 60 < 900 6675A 2160 120 18 1 1 16 0.04 + 120 < 900 6680A 4375 5 875 1 1 10 0.04 + 5 < 900 Full RU w x
5 RU h
6681A 4640 8 580 1 1 10 0.04 + 8 < 900 6682A 5040 21 240 1 1 10 0.04 + 21 < 900 6683A 5120 32 160 1 1 10 0.04 + 32 < 900 6684A 4800 40 128 1 1 10 0.04 + 40 < 900 6690A 6600 15 440 1 1 15 0.04 + 15 < 900 Full RU w x 6691A 6600 30 220 1 1 25 0.04 + 30 < 900 6692A 6600 60 110 1 1 25 0.04 + 60 < 900 Model Size** PerformancePerformance Precision Transient response (µs) * Output 1 / Output 2 / Output 3 / Output 4 ** NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is e ither 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For exampl e: a 3 RU h has a height of 5.25” (133.3 mm) Number of outputsNumber of rangesRipple and noise mVp-p
16 | Keysight | Power Products – October 2015 - Selection Guide B2961A/62A 6.5 Digit Low Noise Power Source The Keysight B2961A/B2962A 6.5 Digit Low Noise Power Source is an advanced low cost power supply/source offering: – 6.5 digit precision, wide and bipolar (4-quadrant) output – Both voltage(100 nV – 210 V) and current(10 fA – 3A DC/10.5 A pulsed) source modes – 10 μVrms (1 nVrms/√Hz at 10 kHz) output noise with external ultra-low noise ilter – 100 nV/10 fA sourcing resolution – Precision arbitrary waveform genera- tion capability (1 mHz – 10 kHz) – Programmable output resistance and emulation – Time domain voltage/current monitor- ing on the front panel These superior capabilities allow tests and evaluation that conventional power supply/ sources cannot do. They make the B2961A and B2962A ideal companion instruments for use with other instruments such as oscilloscopes, network analyzers, spec - trum analyzers, frequency counters, digital multi meters, nanovoltmeters, etc. The Keysight B2961A/B2962A can support the dificult measurement challenges faced by researchers, electronic development engi - neers and electronic technicians working on advanced devices and materials. Since the Keysight B2961A & B2962A are highly stable current/voltage sources ideal for evaluating the physical properties of materials and many types of samples, they ensure that you can detect all tiny signal variations emanating from materials under test. Performance Model B2961A/62A B2961A/62A with LNF (Low Noise Filter) B2961A/62A with ULNF (Ultra Low Noise Filter) Number of channels 1 / 2 1 / 2 1 / 2 Max output Voltage ± 210 V ± 210 V ± 42 V Current DC ± 3.03 A ± 3.03 A ± 105 mA Pulsed ± 10.5 A ± 10.5 A ± 105 mA Power 31.8 W 31.8 W 31.8 W Source Max digits Digits 6½ 6½ 6½ Min resolu - tion Voltage 100 nV 100 nV 100 nV Current 10 fA 10 pA 10 pA Noise
0.1 Hz - 10 Hz < 5 µVpp
< 1 pApp < 5 µVpp < 1 pApp < 5 µVpp < 1 pApp
10 Hz - 20 MHz 3 mVrms 350 µVrms
10 µVrms 1 nVrms/√Hz at 10 kHz Measurement Max digits Digits 4½ 4½ 4½ Min programmable interval for arbitrary waveform 10 µs (100,000 pts/s) 10 µs (100,000 pts/s) 10 µs (100,000 pts/s) B2961A/62A
17 | Keysight | Power Products – October 2015 - Selection Guide NEW N6900 and N7900 Advanced Power System (APS) Overcome your toughest power test challenges With Advanced Power System (APS) 1 kW and 2 kW system power supplies, you get a new level of power supply performance. VersaPower architecture delivers industry-leading speciications and innovative features for today’s advanced ATE power testing needs—the fastest, most accurate, integrated power system. – Accelerate test-system throughput with industry-leading speed – Capture your DUT’s current proile with accurate measurements – Reduce your ATE development time and cost with highly integrated capa- bilities Need high performance in your ATE system? Choose the Keysight N6900 Series APS DC Power Supply. Need high speed dynamic sourcing and measurement? Choose the Keysight N7900 Series APS Dynamic DC Power Supply. Get lots of power in a small test-system footprint Two power ranges deliver a large amount of power in a small test-system footprint. Building a continuous source and load Increasing test system throughput Protecting against power related damage Generating power transients Character- izing inrush current Characterizing dynamic current proiles Properly powering on/off a DUT Tracking power events for root-cause analysis Maintaining output integrity under dynamic load conditions Programming accuracy % + mVModel Performance Transient response (µs)Power (W)Maximum V (V)Maximum I (A)Number of outputsNumber of rangesRipple and noise mVp-p Size* N6950A 1000 9 100 1 1 9 0.03 + 1.5 100 Full RU w x N6951A 1000 20 50 1 1 9 0.03 + 3 100 N6952A 1000 40 25 1 1 9 0.03 + 6 100 N6953A 1000 60 16.7 1 1 9 0.03 + 9 100 N6954A 1000 80 12.5 1 1 9 0.03 + 12 100 N6970A 2000 9 200 1 1 9 0.03 + 1.5 100 Full RU w x N6971A 2000 20 100 1 1 9 0.03 + 3 100 N6972A 2000 40 50 1 1 9 0.03 + 6 100 N6973A 2000 60 33 1 1 9 0.03 + 9 100 N6974A 2000 80 25 1 1 9 0.03 + 12 100 N6976A 2000 120 16.7 1 1 30 0.03 + 17 100 N6977A 2000 160 12.5 1 1 30 0.03 + 24 100 N7950A 1000 9 100 1 1 9 0.03 + 1 100 Full RU w x N7951A 1000 20 50 1 1 9 0.03 + 2 100 N7952A 1000 40 25 1 1 9 0.03 + 4 100 N7953A 1000 60 16.7 1 1 9 0.03 + 6 100 N7954A 1000 80 12.5 1 1 9 0.03 + 8 100 N7970A 2000 9 200 1 1 9 0.03 + 1 100 Full RU w x N7971A 2000 20 100 1 1 9 0.03 + 2 100 N7972A 2000 40 50 1 1 9 0.03 + 4 100 N7973A 2000 60 33 1 1 9 0.03 + 6 100 N7974A 2000 80 25 1 1 9 0.03 + 8 100 N7976A 2000 120 16.7 1 1 30 0.03 + 11 100 N7977A 2000 160 12.5 1 1 30 0.03 + 14 100 * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is ei ther 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For exampl e: a 3 RU h has a height Overcome a wide variety of power test challenges with the APS
18 | Keysight | Power Products – October 2015 - Selection Guide The N6700 Series 1U-high, multiple-out- put programmable DC power supply system gives you the lexibility to optimize performance, power and price to match your test needs. – Small size: up to 4 outputs in 1U of rack space – Mainframes are available with
400 W, 600 W, or 1200 W
– Mix and match from 36 different DC power modules, ranging 50 W, 100 W,
300 W, or 500 W
– Streamline your tasks with built-in measurements, output sequencing, and optional LIST mode, built-in digitizer and disconnect relays – Ultra fast command processing time (< 1 ms) reduces test time – Computer control via GPIB, USB, and LAN (LXI Core) N6700 Low-Proile Modular Power System Extensive family of modular power in a 1U package Model Power (W) Max # modules Physical size* N6700 low-proile modular power system mainframe N6702A N6700B 400 4 Full RU w x
- NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is eit her 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For example : a 3 RU h has a height Programming accuracy % + mV N6731B 50 5 10 1 1 1 10 0.1 + 19 < 200 N6732B 50 8 6.25 1 1 1 12 0.1 + 19 < 200 N6733B 50 20 2.5 1 1 1 14 0.1 + 20 < 200 N6734B 50 35 1.5 1 1 1 15 0.1 + 35 < 200 N6735B 50 60 0.8 1 1 1 25 0.1 + 60 < 200 N6736B 50 100 0.5 1 1 1 30 0.1 + 100 < 200 N6741B 100 5 20 1 1 1 11 0.1 + 19 < 200 N6742B 100 8 12.5 1 1 1 12 0.1 + 19 < 200 N6743B 100 20 5 1 1 1 14 0.1 + 20 < 200 N6744B 100 35 3 1 1 1 15 0.1 + 35 < 200 N6745B 100 60 1.6 1 1 1 25 0.1 + 60 < 200 N6746B 100 100 1 1 1 1 30 0.1 + 100 < 200 N6773A 300 20 15 1 1 1 20 0.1 + 20 < 250 N6774A 300 35 8.5 1 1 1 22 0.1 + 35 < 250 N6775A 300 60 5 1 1 1 35 0.1 + 60 < 250 N6776A 300 100 3 1 1 1 45 0.1 + 100 < 250 N6777A 300 150 2 1 1 1 68 0.1 + 150 < 250 N6751A 50 50 5 1 1 Autoranging 4.5 0.06 + 19 < 100 N6752A 100 50 10 1 1 Autoranging 4.5 0.06 + 19 < 100 N6753A 300 20 50 1 2 Autoranging 5 0.06 + 10 < 100 N6754A 300 60 20 1 2 Autoranging 6 0.06 + 25 < 100 N6755A 500 20 50 1 2 Autoranging 5 0.06 + 10 < 100 N6756A 500 60 17 1 2 Autoranging 6 0.06 + 25 < 100 N6761A 50 50 1.5 1 1 Autoranging 4.5 0.016 + 6 < 100 N6762A 100 50 3 1 1 Autoranging 4.5 0.016 + 6 < 100 N6763A 300 20 50 1 2 Autoranging 5 0.03 + 5 < 100 N6764A 300 60 20 1 2 Autoranging 6 0.03 + 12 < 100 N6765A 500 20 50 1 2 Autoranging 5 0.03 + 5 < 100 N6766A 500 60 17 1 2 Autoranging 6 0.03 + 12 < 100 Model BasicPerformancePrecision Transient response (µs) Specialty Additional N6780 series source measure unit modules and application speciic modules available, see page 23. Power (W)Maximum V (V)Maximum I (A)Number of outputsNumber of rangesRipple and noise mVp-pNumber of slots occupied
19 | Keysight | Power Products – October 2015 - Selection Guide Gain insight into your device’s power consumption in minutes without writing a single line of code. The N6705B combines one to four DC power supplies, a DMM, an oscilloscope, an arbitrary waveform generator, and a data logger in one integrated package. – Saves time—no programming required and it eliminates the need to gather multiple instruments – Flexible, modular system—mix and match power modules to optimize your testing – Uses the same modules as the N6700 Series low-proile modular power supply—see page 15 – Computer control via GPIB, USB, and LAN (LXI Core) N6705B DC Power Analyzer Quickly understand your device’s power consumption Function Description Output speed Voltage changes as fast as 160 μs per step voltage change Voltmeter accuracy Up to 0.025% + 50 μV, up to 18-bit resolution Ammeter accuracy Up to 0.025% + 8 nA, up to 18-bit resolution Arbitrary Waveform Bandwidth up to 100 kHz, output power up to 300 W Scope function Digitizes voltage and current at up to 200 kHz, up to 512 k points, up to 18-bits resolution Data logger function Measurement interval from 20 μs to 60 s, maximum of 500 Mreadings per data log Non-volatile data storage 4 GB
20 | Keysight | Power Products – October 2015 - Selection Guide The 66000 Series modular DC power supplies give you up to eight outputs per mainframe. The modular design conserves rack space and simpliies system cabling and assembly. – Modular system permits up to 8 outputs of 150 W per output in 4U of rack space – Modules are available with 150 W, 8 V to 200 V, 0.75 A to 16 A – Simplify reconiguration or repair with easily swappable modules – Streamline your tasks with built-in measurements, LIST mode, and optional keyboard for manual control – Full protection from over voltage and over current – Computer control via GPIB
66000 Modular Power System
Speed and accuracy with up to eight outputs Model Power, (W) Max # modules Physical size* 66000A 1200 8 Full RU w x 4 RU h 66000 modular power system mainframe * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is ei ther 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For exampl e: a 3 RU h has a height of 5.25” (133.3 mm) Power (W)Model Performance Transient response (ms)Programming accuracy % + mV 66000 modules Maximum V (V)Maximum I (A)Number of outputsNumber of rangesRipple and noise mVp-p 66101A 128 8 16 1 1 5 0.03 + 3 < 1 66102A 150 20 7.5 1 1 7 0.03 + 8 < 1 66103A 150 35 4.5 1 1 10 0.03 + 13 < 1 66104A 150 60 2.5 1 1 15 0.03 + 27 < 1 66105A 150 120 1.25 1 1 25 0.03 + 54 < 1 66106A 150 200 0.75 1 1 50 0.03 + 90 < 1
21 | Keysight | Power Products – October 2015 - Selection Guide Loads Loads Constant current accuracy, % + mAConstant voltage accuracy, % + mV 6060B 300 60 60 0.1 + 75 0.1 + 50 0.05 + 65 0.05 + 45 Full RU w x 4 RU h6063B 250 240 10 0.15 + 10 0.12 + 120 0.12 + 10 0.1 + 150 Model Size* 6060 loads Current measurement accuracy, % + mA Voltage measurement accuracy, % + mV N3300 and 6060 Series DC Electronic Loads Programmable loads with measurements * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is ei ther 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For ex ample: a 3 RU h has a height of 5.25” (133.3 mm) – Cost effective load for single input
applications
– Ideal for bench applications, provides optional front panel connection – Computer control via GPIB N3300 Multiple Input Electronic Loads
6060 Single Input
accuracy, % + mAConstant voltage accuracy, % + mV N3302A 150 60 30 0.1 + 10 0.1 + 8 0.05 + 6 0.05 + 8 1 N3304A 300 60 60 0.1 + 15 0.1 + 8 0.05 + 10 0.05 + 8 1 N3305A 500 150 60 0.1 + 15 0.1 + 20 0.05 + 10 0.05 + 16 2 N3307A 250 150 30 0.1 + 15 0.1 + 20 0.05 + 6 0.05 + 16 1 Model N3300 modules Current measurement accuracy, % + mA Width, slotVoltage measurement accuracy, % + mV Model Max # modules Physical size* N3300A 6 Full RU w x 4 RU h N3301A 2 ½ RU w x 4 RU h N3300 mainframes N3300A – Increase test throughput with short command processing time and stored command sequences – Test multiple power supply outputs with up to 6 modules with 150 W to 600 W capability – Operate in constant current, con- stant voltage, or constant resistance modes – Measure voltage and current simulta - neously – Use in parallel for greater current sinking capability – Computer control with GPIB The N3300 and 6060 Series DC electronic loads give you lexibility for testing power supplies and other devices requiring a load. The built-in measurement system provides both accuracy and convenience and eliminates the need for a DMM, external shunts and wiring. The N3300 multiple-input models are fast, accurate, and ideal for high-volume manufacturing, while single input 6060 models are ideal for evaluation of DC power sources and power components on your bench. Maximum input, V Maximum input, V Input power, W Input power, W Maximum input, I Maximum input, I
22 | Keysight | Power Products – October 2015 - Selection Guide AC Single-Phase Power Sources An integrated AC power solution Keysight offers two families of AC power sources to meet your AC test challenges— from basic to complex. The AC6800 Series of basic AC sources offer stable, reliable power with models available up to 4000 VA. The 6800B series of performance AC sources provide a complete AC test solu- tion with built in arbitrary waveform generator to simulate many types of power waveforms, at power levels up to 1750 VA. Both families may also be used to produce DC power, either alone or as a DC offset to an AC waveform. All models are backed with global support and the longest stan- dard warranty in the industry. AC6800 Series Basic AC Sources The quality and capability you need. – Models up to 4000 VA are available to meet your basic AC power source and measurement requirements – An intuitive user interface tested over time – LAN/LXI Core and USB (standard), and GPIB (optional plug-in card) 6800B Series Performance AC Sources/Analyzers The complete AC power test solution. – Models up to 1750 VA are available to meet your performance AC source requirements – Extensive built-in power measurement capabilities – GPIB – Integrated transient waveform gen- eration and harmonic capabilities to simulate and analyze your AC environ- ment 6800B Series AC6800 Series BasicPerformance Model RMS power RMS voltage RMS current Output frequency Peak current DC power DC voltage AC6801A 500 VA 270 V 5 A 500 Hz 7.5 A 400 W 380 V AC6802A 1000 VA 270 V 10 A 500 Hz 15 A 800 W 380 V AC6803A 2000 VA 270 V 20 A 500 Hz 30 A 1600 W 380 V AC6804A 4000 VA 270 V 40 A 500 Hz 60 A 3200 W 380 V 6811B 375 VA 300 V 3.25 A 1 kHz 40 A 285 W 425 V 6812B 750 VA 300 V 6.5 A 1 kHz 40 A 575 W 425 V 6813B 1750 VA 300 V 13 A 1 kHz 80 A 1350 W 425 V
23 | Keysight | Power Products – October 2015 - Selection Guide NEW N6780 Series Source Measure Units (SMUs) Deliver exceptional battery life The N6781A and NEW N6785A are 2-quadrant SMUs for battery drain analysis. They offer advance features to accurately capture the power con- sumption of portable, battery-powered devices from 20 W to 80 W. Whether the DUT is a mobile phone, “phablet,” tablet, or pacemaker, the N6781A and N6785A’s seamless measurement rang- ing, programmable output resistance, and auxiliary DVM helps you deliver exceptional battery life. The N6782A and NEW N6786A are 2-quadrant SMUs for function test of a device from 20 W to 80 W. It has the ability to modulate its output up to 100 kHz along with the capability to source and sink current. The N6784A is a 4-quadrant SMUs that provides precise sourcing and measurement for general purpose applications. The N6780 source measure units (SMUs) are modules for the N6705B DC power analyzer mainframe for R&D, and the N6700 low-proile mainframes for ATE. – Seamless, dynamic measurements down to nA and μV (N6781A/82 and N6785A/86 only) – Glitch-free operation—change sourcing ranges or measurement ranges without any glitches – Excellent transient response for stable output voltage with dynamic loads – 2 or 4-quadrant operation: use as a DC power supply or electronic load – Fast modulation of DC output to create arbitrary waveforms up to 100 kHz – Computer control via GPIB, USB, and LAN (LXI Core) 14585A Control and Analysis Software The software for the DC power analyzer compliments the front panel of the N6705 mainframe, offering advanced functionality and PC control. It is a l exible R&D tool for any application. When used to control an N6781A or N6785A SMU, it can be used for advanced battery drain analysis applications. – Control and analyze data from up to four N6705 DC power analyzer and any installed modules at once – Easily create complex waveforms to stimulate or load down a DUT by inputting a formula, choosing from built-in, or importing waveform data. – Data log (gapless) measurements directly to a PC – Perform statistical analysis of power consumption Specialty Model Power (W) Max voltage (V) Max current (A) Ripple and noise (mVp-p) Programming accuracy % + µV Transient response (µs) N6781A 20 20 ± 3 12 0.025 + 200 ≤ 35 N6782A 20 20 ± 3 12 0.025 + 200 ≤ 35 N6784A 20 ± 20 ± 3 12 0.025 + 200 ≤ 35 New N6785A 80 20 ± 8 15 0.025 + 1800 ≤ 35 New N6786A 80 20 ± 8 15 0.025 + 1800 ≤ 35 N6780 SMU modules Flexible/reconigurable Available slots Mainframe accepts up to 4 DC power modules Power 600 W total DC module output power Instrument control GPIB, USB, LAN (LXI Class C Compliant) N6705B DC Power Analyzer N6781A N6782A N6705B N6785A
24 | Keysight | Power Products – October 2015 - Selection Guide Specialty B2900A Series Precision Source/Measure Units The Keysight B2900A Series of Precision Source/Measure Units are compact and cost-effective bench-top Source/Mea - sure Units (SMUs). The SMU combines the capabilities of a current source, a voltage source, a current meter and a voltage meter along with the capability to switch easily between these various functions into a single instrument. It offers: – Test capability up to 210 V and 3 A (DC) or 10.5 A (pulsed) with a single instrument – Best-in-class 6.5 digit source and measurement resolution down to 10 fA and 100 nV – 10 µs digitizing capability – Innovative GUI facilitate fast bench- top test, debug and characterization – Ultrafast throughput for lower cost-of- test These capabilities are ideal for a wide variety of IV (current versus voltage) measurement tasks that require both high resolution and accuracy. The innovative graphical user interface with four view- ing modes (single view, dual view, graph view and roll view) improves usability and productivity of bench-top tests, debug and characterization dramatically. The Keysight B2900A series of SMU is also well-suited for production with the fast measurement speed. B2901A B2902A B2911A B2912A Number of channels 1 2 1 2 Max output Voltage ± 210 V ± 210 V ± 210 V ± 210 V Current DC ± 3.03 A ± 3.03 A ± 3.03 A ± 3.03 A Pulsed ± 10.5 A ± 10.5 A ± 10.5 A ± 10.5 A Power 31.8 W 31.8 W 31.8 W 31.8 W Source Max digits Digits 5 ½ 5 ½ 6 ½ 6 ½ Min resolution Voltage 1 µV 1 µV 100 nV 100 nV Current 1 pA 1 pA 10 fA 10 fA Measurement Max digits Digits 6 ½ 6 ½ 6 ½ 6 ½ Max resolution Voltage 100 nV 100 nV 100 nV 100 nV Current 100 fA 100 fA 10 fA 10 fA Min programmable interval for List sweep/AWG waveform 20 µs 20 µs 10 µs 10 µs Min trigger interval for digitizing (Max sample rate) 20 µs (50,000 pts/s) 20 µs (50,000 pts/s) 10 µs (100,000 pts/s) 10 µs (100,000 pts/s)
25 | Keysight | Power Products – October 2015 - Selection Guide USB Modular Source Measure Unit Source and measure DC voltage/current reliably The Keysight USB modular source mea- sure unit (SMU) allows you to perform sweeps and make measurements using a single device. The SMU offers voltage and current programming/readback with high accuracy measurement capabilities. You can conigure each of the three channels separately or in a matrix—in series or par - allel—for increased power. It comes bun - dled with Keysight Measurement Manager (AMM) software that includes a command logger function to help you convert SCPI commands into snippets of VEE, V, C+ and C# code. – Three-channel, four-quadrant opera- tion (± 20 V, ± 120 mA) – High measurement sensitivity of 100 pA with 16-bit resolution – 0.1% basic accuracy – Low current measurement capability down to nA levels – Embedded test script able to support three channels with coherent source and measurement capabilities (for U2723A) – IV Curve application support in the Keysight Measurement Manager Software (for U2723A) – Faster rise/fall time (for U2723A) – Hi-Speed USB 2.0 (480 Mbps) U2722A SpecialtySpecialty Model U2722A/23A Number of outputs 3 Output ratings (at 0 °C to 50 °C) Voltage –20 V to 20 V per channel Current –120 mA to 120 mA per channel 1 Drive 50% of 1 V or 10 V output with a resistive load. Rise time is from 10% to 90% of program voltage change at maximum current. Fall time is from 90% to 10% of program voltage change at maximum current. 2 Measurements obtained are per default bandwidth setting. Model U2722A/23A Range Accuracy 1 Resolution Voltage programming/ readback ± 2 V 0.075% + 1.5 mV 0.1 mV ± 20 V 0.05% + 10 mV 1 mV Current programming/ readback ± 1 µA 0.085% + 0.85 nA 100 pA ± 10 µA 0.085% + 8.5 nA 1 nA ± 100 µA 0.075% + 75 nA 10 nA ± 1 mA 0.075% + 750 nA 100 nA ± 10 mA 0.075% + 7.5 µA 1 µA ± 120 mA 0.1% + 100 µA 20 µA Model U2722A U2723A Rise/fall time (ms) 1 Range Accuracy 1 Accuracy 1 For resistive measurement 2 ± 1 µA 170.0 15.0 ± 10 µA 18.0 5.0 ± 100 µA 6.0 1.0 ± 1 mA 1.0 1.0 ± 10 mA 1.0 1.0 ± 120 mA 1.0 1.0
26 | Keysight | Power Products – October 2015 - Selection Guide Precision IV Analyzer / Source Monitor Unit Mainframe Series Keysight Precision IV Analyzer Se- ries (E5262A, E5263A, E5260A and E5270B) is the complete solution for currentvoltage characterization. It sup - ports multiple SMUs (Source/Monitor Units) for voltage/current sourcing and voltage/current measurement with the best in the class current measurement performance. It’s modular architecture allows you to conigure or upgrade SMU modules for available eight slots (E5260A/E5270B) The EasyEXPERT group+ GUI based characterization software is furnished and available on your PC. It supports eficient and repeatable device charac - terization in the entire characterization process from measurement setup and execution to analysis and data management either by interactive manual operation or automation across a wafer in conjunction with a semi- automatic wafer prober. EasyEXPERT group+ makes it easy to perform cur- rentvoltage characterization immedi- ately with the ready-touse measure - ments (application tests) furnished, and allows you the option of storing test condition and measurement data automatically after each measurement in a unique built-in database (work- space), ensuring that valuable informa- tion is not lost and that measurements can be repeated at a later date. 8 slot mainframe SMU conigurable model (E5260A/E5270B) Two SMU pre-ixed coniguration model (E5262A/E5263A) Powerful integration of SMU’s versatile measurement capabilities and GUI based characterization software makes it the best solution for characterization and evaluation of devices, materials, semi- conductors, active/passive components, or virtually any other type of electronic device with uncompromised measure- ment reliability and eficiency. The Precision IV Analyzer Series is also available as a system component SMU for a rack and stuck test system. It provides the scalability and the highest measurement accuracy in the class for current-voltage measurement. It can be controlled remotely by the FLEX command set supporting the powerful measurement capabilities. Precision IV Analyzer series E5262A E5263A E5260A E5270B MPSMU Max. output 100 V / 200 mA 100 V / 200 mA 100 V / 200 mA 100 V / 100 mA (Medium Power SMU) Min. resolution 5 pA / 100 µV 5 pA / 100 µV 5 pA / 100 µV 10 fA / 0.5 µV HPSMU (High Power SMU) Max. output NA 200 V/1 A 200 V/1 A 200 V/1 A Min. resolution NA 5 pA / 100 µV 5 pA / 100 µV 10 fA / 2 µV HRSMU (High Resolution SMU) Max. output NA NA NA 100 V / 100 mA Min. resolution NA NA NA 1 fA / 0.5 µV ASU (*) (Atto-sense Switch Unit) Max. output NA NA NA 100 V / 100 mA Min. resolution NA NA NA 0.1 fA / 0.5 µV (*) One ASU requires one HRSMU module to connect it.
27 | Keysight | Power Products – October 2015 - Selection Guide Specialty Semiconductor Device Analyzer Keysight B1500A Semiconductor Device Analyzer of Precision Cur- rent-Voltage Analyzer Series is an all in one analyzer supporting IV, CV, pulse/dynamic IV and more, which is designed for all-round characterization from basic to cutting-edge appli- cations. It provides a wide range of measurement capabilities to cover the electrical characterization and evaluation of devices, materials, semiconductors, active/passive com - ponents, or virtually any other type of electronic device with uncompromised measurement reliability and eficiency. In addition, the B1500A’s modular architecture with ten available slots allows you to add or upgrade measure- ment modules if your measurement needs change over time. Keysight EasyEXPERT group+ GUI based characterization software is available either on the B1500A’s Test coverage Supported module Key speciications Key features For DC and pulsed IV measurement B1510A High Power Source/ Measure Unit (HPSMU) – Up to 200 V/1 A – Min 10 fA/2 μV resolution – Min 100 μs Sampling (time domain) measurement – Min 500 μs pulse width with 100 μs resolution – Quasi-static capacitance voltage (QSCV) measurement with leakage current compensation – 4 quadrant operation – Kelvin (4-wire) connection – Spot, sweep and other capabilities B1511B Medium Power Source/Measure Unit (MPSMU) – Up to 100 V/0.1 A – Min 10 fA/0.5 μV resolution – Optional ASU for 0.1 fA and IV/CV switching B1517A High Resolution Source/Measure Unit (HRSMU) – Up to 100 V/0.1 A – Min 1 fA/0.5 μV resolution – Optional ASU for 0.1 fA and IV/CV switching B1514A 50 μs Pulse Medium Current Source/Measure Unit (MCSMU) – Up to 30 V/1 A (0.1 A DC) – Min 50 μs pulse width with 2 μs resolution – Oscilloscope view for precision pulsed measurement For capacitance measurement B1520A Multi-Frequency Capacitance Measurement Unit (MFCMU) – 1 kHz to 5 MHz frequency range – 25 V built-in DC bias and
100 V DC bias with SMU
– AC impedance measurement (C-V, C-f, C-t) – Easy, fast and accurate IV and CV measurements with automated switching via SCUU For ultra-fast pulsed and transient IV measurement B1530A Waveform Generator/ Fast Measurement Unit (WGFMU) – 10 ns programmable resolution for waveform generation – 200 MSa/s simultaneous high-speed measurement – 10 V peak-to-peak output – No load line effects; accurate pulsed IV measurement using SMU-based technology – Enabled for advanced applications, such as NBTI/PBTI, RTN, etc. For pulse generation B1525A High Voltage Semiconductor Pulse Generator Unit (HV-SPGU) – Up to ± 40 V high voltage output – Two-level and three-level pulsing and arbitrary waveform generation capability on each channel – Ideal for non-volatile memory testing For ultra-fast pulsed high-k/SOI evaluation B1542A 10 ns Pulsed IV parametric test solution – Min 10 ns gate pulse width with 2 ns rise and fall times – 1 μs current measurement resolution – Accurate Id-Vd and Id-Vg measurement – Easy switching between DC and pulsed measurements B1500A embedded Windows 7 platform with 15-inch touch screen or on your PC to accelerate the characterization tasks. It supports eficient and repeatable device characterization in the entire characterization process from measure- ment setup and execution to analysis and data management either interactive manual operation or automation across a wafer in conjunction with a semi- automatic wafer prober. EasyEXPERT group+ makes it easy to perform com- plex device characterization immediate - ly with hundreds of ready-to-use mea- surements (application tests) furnished, and allows you the option of storing test condition and measurement data auto - matically after each measurement in a unique built-in database (workspace), ensuring that valuable information is not lost and that measurements can be repeated at a later date. Keysight B1500A provides the complete solution for device characterization with these versatile capabilities.
28 | Keysight | Power Products – October 2015 - Selection Guide B1505A Power Device Analyzer / Curve Tracer The B1505A Power Device Analyzer / Curve Tracer is a single box solu - tion for power device evaluation. Its broad measurement range from sub- pA to 10 kV/1500 A enables precise µΩ on-resistance measurements. Additionally, its 10 µs fast pulse capability enables complete power device characterization. This allows evaluation of new power devices such as IGBT and wide band-gap materials such as silicon carbide (SiC) and gallium nitride (GaN). – Very wide current, voltage oper- ating range up to 1500 A,10 kV – Supporting package and on-wa- fer device – Accurate sub-picoamp level current measurement and μΩ on-resistance measurement – 10 μs high power narrow pulse measurement – Three-terminal capacitance (Ciss, Coss, Crss) measurement at up to 3000 V DC bias volt- ages and independent terminal capacitance (Cgs, Cgd, Cds) measurement – Gate charge (Qg) measurement – GaN current collapse measure- ment – Automated thermal test from -50 ˚C to +250 ˚C – Upgradable and scalable hard - ware architecture – Oscilloscope View for current and voltage pulse veriication – EasyEXPERT software simpliies data management and data analysis B1505A Modules Description Key speciication Max Number B1510A High power SMU 200V, 1 A (DC), 10 fA resolution 4 B1511B Medium power SMU 100 V, 100 mA (DC), 10 fA resolution 10 B1512A High current SMU 20 V, 20 A (Pulsed)
30 V, 1 A (DC) 2
B1513C High voltage SMU 3000 V, 8 mA (Pulse and DC) 5 B1514A Medium current SMU 30 V, 1 A (Pulsed)
30 V, 100 mA (DC) 5
B1520A Multi-Frequency CMU 1 kHz to 5 MHz, ±25 V (internal bias) 1 External Modules Description Key speciication N1265A Ultra high current ex- pander / Fixture ±1500 A / 60 V (Pulsed) N1266A HVSMU Current Ex- pander ±1500 V/2.5 A (Pulsed), ±2200 V/1.1 A (Pulsed) N1267A High voltage/high cur- rent fast switch ±3000 V, ±20 A (Pulsed), Minimum transition (OFF to ON) : 20 μs N1268A Ultra High Voltage Unit 10 kV/10 mA (DC), 10 kV/20 mA (Pulsed) Accessories Description N1258A Module Selector N1259A Test Fixture N1260A High Voltage Bias-T N1271A Thermal Test Enclosure N1272A Device Capacitance Selector N1273A Capacitance Test Fixture N1274A On-wafer Gate Charge Measurement Adapter for 20 A/3 kV N1275A On-wafer Gate Charge Measurement Adapter for N1265A
29 | Keysight | Power Products – October 2015 - Selection Guide B1506A Power Device Analyzer for Circuit Design The B1506A Power Device Analyzer for Circuit Design is a complete solu - tion that can help power electronic circuit designers maximize the value of their power electronics products by enabling them to select the cor- rect power devices. It can evaluate all relevant device parameters under a wide range of operating condi- tions, including IV parameters such as breakdown voltage and on-re- sistance, as well as three terminal FET capacitances, gate charge and power loss. – Wide current and voltage oper- ating range up to 1500 A, 3000 V – 10 μs high power narrow pulse measurement – Automated thermal test from -50 ˚C to +250 ˚C – Three-terminal capacitance (Ciss, Coss, Crss) measurement at up to 3000 V DC bias volt- ages and independent terminal capacitance (Cgs, Cgd, Cds) measurement – Gate charge (Qg) measure- ment – Power loss calculation – Menu driven easy-to-use user interface (Easy Test Navigator – ETN) – Quick and automatic device datasheet generation – Oscilloscope view for current and voltage pulse veriication Category Parameters Threshold voltage V(th), Vge(th) Transfer characteristics Id-Vgs, Ic-Vge, gfs On resistance Rds-on, Vce(sat) Gate leakage current Igss, Iges Output leakage current Idss, Ices Output characteristics Id-Vds, Ic-Vce Breakdown voltage BVds, BVces Gate charge Qg, Qg(th), Qgs, Qgd, Qsw, Qsync, Qoss Gate resistance Rg Device capacitance Ciss, Coss, Crss, Cgs, Cgd, Cies, Coes, Cres Power loss calculation Driving loss, Switching loss, Conduction loss Model Number Option Description B1506A Power Device Analyzer for Circuit Design H21 20 A/3 kV/C-V/Gate Charge/Thermal Fixture Package H51 500 A/3 kV/C-V/Gate Charge/Thermal Fixture Package H71 1500 A/3 kV/C-V/Gate Charge/Thermal Fixture Package T01 Thermal Test Enclosure (Thermostream Compatible)
30 | Keysight | Power Products – October 2015 - Selection Guide B1507A Power Device Capacitance Analyzer With the increasing use of power devices fabricated from emerging new materials such as SiC and GaN, switching power supplies are operating at increasingly higher fre - quencies. The B1507A Power Device Capacitance Analyzer meets this need, providing a complete solution for the evaluation of power device capacitance. The B1507A can help power device development engi - neers maximize product value and performance by revealing detailed device characteristics. –Measure transistor input, output and reverse transfer capacitances (Ciss, Coss, Crss, Cies, Coes, Cres) at high bias voltages, and independent ter- minal capacitances (Cgs, Cgd, Cds, Cge, Cgc, Cce) –Measure capacitances for nor - mally-on devices such as SiC or GaN FET –Measure gate resistance (Rg) –Measure capacitance continu - ously as the gate voltage varies from negative to positive – Easy to switch back and forth between leakage tests and capacitance measurements – Wide operation voltage bias up to +/-3000 V – Easy to use and fully automat- ed measurement Frequency Range Capacitance Range Maximum Collector / Drain voltage Maximum Gate voltage 1 kHz to 1 MHz 10 fF to 1 μF ± 3000 V ± 100 V Category Parameters Device capacitance Ciss, Coss, Crss, Cgs, Cgd, Cies, Coes, Cres Gate leakage current Igss, Iges Output leakage current Idss, Ices Breakdown voltage BVds, BVces Threshold voltage V(th), Vge(th) Ciss/Coss/Crss measurement up to 3kV Gate Resistance Measurement Device capacitance selector for automated CV measurement HVSMU MPSMU MFCMU Device capacitance selector - Switch - AC blocking R - DC blocking C
31 | Keysight | Power Products – October 2015 - Selection Guide Model Power, (W) Max # modules N6700B low-proile (ATE) 400 4 N6701A low-proile (ATE) 600 4 N6702A low-proile (ATE) 1200 4 N6705B DC power analyzer (R&D) 600 4 N6700 modular power system mainframeSpecialty Model Power (W) Max voltage (V) Max current (A) Ripple and noise (mVp-p) Programming accuracy % + µV Transient response (µs) N6783A-BAT 24 8 +3 to –2 A 8 0.1 + 10 ≤ 45 N6783A-MFG 18 6 +3 to –2 A 8 0.1 + 10 ≤ 45 N6700B N6705B The Keysight N6783A-BAT Battery Charge/Discharge Module is a basic, 2-quadrant module designed to be used by battery-powered (mobile) device designers. The N6783A-BAT’s 2-quadrant operation allows it to act as a power supply to charge the battery or as an electronic load to discharge the battery. When used in the N6705B DC Power Analyzer mainframe along with the 14585A Control and Analysis software, short-and long-term measurements for battery validation are made easy. The Keysight N6783A-MFG Mobile Communications DC Power Module offers advanced features speciically for testing battery-powered (mobile) devices in manufacturing. The N6783A-MFG offers fast, accurate measurements and excellent voltage transient response to address the unique challenges associated with testing mobile wireless devices. The N6783A-BAT and N6783A-MFG modules can be used with the N6700 low-proile mainframes for ATE and with the N6705B DC power analyzer mainframe for R&D. – Optimized for basic battery charge/discharge application (N6783A-BAT) – Optimized for mobile device manufacturing test (N6783A-MFG) – Fast transient response ensures stable power supply output voltage – Digitizing measurement system for lexible, accurate current measurements – USB, LAN (LXI Core), and GPIB interfaces
32 | Keysight | Power Products – October 2015 - Selection Guide 66300 mobile communications power supplies are designed and optimized to help you test mobile wireless devices. They provide the DC sourcing, current sinking, and measurement capabilities to address the unique challenges of simulating batteries and battery packs and measuring the current drawn by your device under test. – Fast DC power source to replace and simulate the battery during testing – Fast voltage transient response ensures maximum test-system throughput by minimizing device shutdowns – Dynamic measurement system enables accurate current measurement from µA to A – When the 66319B/D and 66321B/D are coupled with the 14565B Software, it gives you a powerful analysis tool to optimize your device designs for long battery life – Graphical user software— no programming required – 3 modes of operation: waveform capture, data logging, CCDF statistical analysis – Visualization and analysis tools to help you identify anomalies and characterize and quantify battery drain to optimize your design – Automation capability allows you to control the 14565B from other programs to automate and synchronize DUT activity with current drain measurements
66300 Mobile Communications DC Sources
Power (W)Maximum V (V) Maximum I (A) Programming accuracy % + mV 66309B/D 45 15 3 (5 A peak) 2 1 6 0.05 + 10 < 35 ½ RU w x 66311B 45 15 3 (5 A peak) 1 1 6 0.05 + 10 < 35 66319B/D 45 15 3 (5 A peak) 2 1 6 0.05 + 10 < 20 66321B/D 45 15 3 (5 A peak) 1 1 6 0.05 + 10 < 20 66332A 100 20 5 2 1 3 0.05 + 10 < 100 Model Size*Transient response (µs) * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is ei ther 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For exampl e: a 3 RU h has a height of 5.25” (133.3 mm) Number of outputsNumber of rangesRipple and noise mVp-p Specialty
33 | Keysight | Power Products – October 2015 - Selection Guide The modular solar array simulator (SAS) is a DC power source that simulates the output characteristics of a solar array. The SAS is primarily a current source with very low output capacitance. It is capable of simulating the I-V curve of different arrays under different environmental conditions (temperature, age, etc.). You can set the I-V curve from the front panel or program it over GPIB, LAN (LXI Core) or USB. – Accurate simulation of any type of solar array – Small size: up to 2 outputs in 2U of rack space – High output power—up to
600 W per output
– Fast I-V curve changes to simulate eclipse or spin – 14360A System Control Tools software included to simplify control of multiple solar array simulators in a system – Custom turn-key system or individual instruments available E4360 Modular Solar Array Simulation Specialty Model Power, W Max Voc Max Isc Number of outputs Ripple and noise mVp-p Programming accuracy % + mV E4361A 510 65 8.5 1 125 0.075 + 10 E4362A 600 130 5 1 195 0.075 + 20 E4360 modules * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is ei ther 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For example: a 3 RU h has a height of 5.25” (133.3 mm) Specialty Model Power, W Modules Max # of modules Physical size* E4360A 120 0 Choose from E4361A and E4362A 2 Full RU w x 2 RU h E4367A 120 0 Pre-conigured with 2x E4361A 2 Full RU w x 1 RU h E4368A 120 0 Pre-conigured with 2x E4362A 2 Full RU w x 1 RU h E4360 modular solar array simulator mainframes E4360A modules E4360A SAS mainframe
34 | Keysight | Power Products – October 2015 - Selection Guide NEW N8937APV and N8957APV Photovoltaic Array Simulators Quickly Test and Optimize Inverter MPPT Algorithms for Improved Solar Power Production The Keysight N8937APV and N8957APV Photovoltaic Array Simulator helps engineers develop, verify and maximize the performance of inverter maximum power point tracking algorithms. With its 1500Vdc output, the N8937APV and N8957APV enables designers to test to emerging solar panel technologies. – 15 kW (1500 Vdc, 30 A) in 3 RU Chassis – Parallel supplies up to 90 kW –Curve & Table PV Simulation Modes –Measure inverter eficiency over a va - riety of simulated conditions (varying temperature and irradiance) – Verify the ability of the inverter to produce grid-level power from low to high voltage extremes – PC based Software Power (W)Maximum V (V) Maximum I (A) Programming accuracy 0.1% + mV N8937APV 15000 1500 30 1 2400 ≤1500 208 Full RU w x
3 RU hN8957APV 15000 1500 30 1 2400 ≤1500 400
Model Size*AC Output Voltage (VAC) * NOTE: RU refers to rack unit of a standard 19” EIA equipment rack. The width is ei ther 1/2 or full. The height is in number of rack units which are 1.75” (44.4 mm) each. For exampl e: a 3 RU h has a height of 5.25” (133.3 mm) Number of outputsRipple and noise mVp-p N8937APV N8957APV
35 | Keysight | Power Products – October 2015 - Selection Guide NEW PA2201A IntegraVision Power Analyzer See it, measure it, prove it The Keysight IntegraVision power analyzer is an intuitive combination of accurate power measurements and touch-driven oscilloscope visualization. Within a single instrument, it delivers the dynamic views you need to see, measure and prove the performance of your design. Make all of your critical power measurements with one instrument – Achieve power analyzer accuracies and scope-like waveform visualization with reduced setup time – Address multiple test scenarios with the lexibility of wide-ranging, isolated inputs – Visualize transients, in-rush currents and state changes with a high-speed digitizer that captures voltage, current and power in real-time – Analyze voltage, current and power in the time and frequency domains – Explore you design and gain new insights through the 12.1”/310 mm high-resolution display with touch interface – Save space on your bench with minimum-depth form factor Function Description Basic power accuracy (50/60 Hz) 0.05% of reading + 0.05% of range Power Channels (Voltage and Current) 2 Voltage Measurement Bandwidth (-3 dB) 2.5 MHz (-3 dB) Current Measurement Bandwidth (2 A or 50 A Input) 100 kHz (-3 dB) Current Measurement Bandwidth (External Input) 2.5 MHz (-3 dB) Maximum Voltage 1000 Vrms (2000 V peak) Maximum Current Direct input: 2 Arms (6 A peak) or 50 Arms (100 A peak) External transducer: 10 Vrms (30 V peak) Record Size Maximum 1.5 M points on each waveform simultaneously Digitizing Speed Maximum 5 M samples/second at 16 bits on each waveform simultaneously Display size and type 12.1- inch capacitive multi-touch/gesture enabled display
www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. 36 | Keysight | Power Products – October 2015 - Selection Guide
www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a full one-year warranty on all accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com www.keysight.com/ind/power From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939.
1939 THE FUTURE
For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-24-15) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System 37 | Keysight | Power Products – October 2015 - Selection Guide This information is subject to change without notice. © Keysight Technologies, 2012 - 2015 Published in USA, October 9, 2015 5989-8853EN www.keysight.com