Microwave Counter, Power Meter and DVM in One Portable Package Technical Overview

Working together, we can anticipate— and apply—the latest advances in electronic technology, accelerating your progress toward new successes. Simplify installation and maintenance of point-to- point microwave links Whether you are installing or main- taining cell-site to base-station links, business-to-business communication links, digital radio links (along rail- roads, pipelines or power lines) or even satellite ground stations, installing and maintaining microwave links typically requires three pieces of equipment. These are a CW microwave counter, a true power meter and a dc DVM. The 53140 Series reduces the weight, volume and hassle of carrying multiple pieces of equipment in the field by combining these three instruments into one. Its rubber bumpers make it rugged and ready to withstand the elements. A soft carrying case option makes transit to the field easy and has a pouch for accessory storage. You will not have to worry about ac power availability at the site with the 53140 Series’ battery option. Plus its LCD display with a switchable backlite saves on battery life. Everything you need for the installation and maintenance of microwave links: – A choice of frequency counter ranges up to 46 GHz – A true power meter to meet your “laboratory-accuracy” require - ments in the field – A dc DVM to assist with antenna alignment and telecom power supply measurements – Lightweight, rugged and a battery option for complete portability in the field

budget dollars by combining three instruments into one For measurements used in microwave component and assembly testing, the compact, three-in-one 53140 Series reduces the need for expensive ATE rack space. The 53140 Series comes ATE-ready with both GPIB and RS-232 SCPI programmable interfaces. A rack mount kit is optional. Is the convenience of measuring frequency and power with a single input more important to you than power measurement accuracy? Then the 53150 Series of CW Microwave Counters may be for you. For more information, visit our website at: www.keysight.com/find/53150A CW microwave counter up to 46 GHz Choose the frequency range you need. The 53140 Series has three ranges; 20 GHz, 26.5 GHz and 46 GHz. The ultra-wideband microwave input cov- ers from 50 MHz up to the maximum frequency. This reduces the need for channel switching. You don’t have to wait for resolution that is not needed as the resolution is selectable from The 53140 Series Measurement Suite 1 Hz to 1 MHz. For better measure- ment accuracy over time and tem- perature, an optional oven timebase is available. True power meter with a wide selection of sensors The 53140 Series true power meter provides laboratory instrument accu- racy in a rugged, field-ready package. Obtain 0.01 dB resolution and 0.02 dB basic instrument accuracy where you need it most—on site. The graphical peaking meter allows you to make fast and easy power adjustments. For more flexibility, a wide range of power sen- sors is available (Keysight Technolo - gies, Inc. 8480 Series*) with a power range from –70 dBm to +44 dBm. DC DVM for AGC and power supply measurements A ± 50 Vdc DVM monitors the mi- crowave receiver’s AGC circuitry for assistance during antenna alignment. The DVM can also check the –48 Vdc power supplies typically found at telecom sites. Advanced instrument features that help make the job easier The Keysight 53140 Series has the fea - tures you expect in a precision labora- tory instrument. Relative readings for both frequency and power measure- ments show deviations from nominal values. Offset reading allows indirect measurement of either final frequency or power values or both. Averaging smooths out rapidly changing mea- surement displays for ease of viewing. * Keysight announced the discontinu- ance of the 848x “A,” “B” and “H” model power sensors that you may use with your counter. However, depending on your power measurement requirements, several of these sensor models can still be purchased from Keysight for use with your microwave frequency counter. www.keysight.com/find/contactus

Specifications and Characteristics All specifications are over full signal and temperature ranges unless ot herwise noted. All specifications are warranted. Those items labeled “typical” or “nominal” are characteristics and are not war ranted. Counter specifications 53147A 53148A 53149A Frequency range Channel 1 Normal mode Low pass filter enabled

10 Hz to 125 MHz

10 Hz to 50 kHz

Channel 2 50 MHz to 20 GHz 50 MHz to 26.5 GHz 50 MHz to 46 GHz Sensitivity Channel 1 10–30 Hz

30 Hz–125 MHz

50–300 MHz 0.3–12.4 GHz 12.4–18 GHz 18–20 GHz 20–26.5 GHz 26.5–40 GHz 40–46 GHz –20 dBm –33 dBm –33 dBm –29 dBm N/A N/A N/A –20 dBm –33 dBm –33 dBm –29 dBm –25 dBm N/A N/A –20 dBm –33 dBm –30 dBm –27 dBm –27 dBm –23 dBm –17 dBm Maximum input Channel 1 2 V rms 2 Vrms 2 Vrms Channel 2

50 MHz to 2 GHz

2–46 GHz +5 dBm +13 dBm +5 dBm +13 dBm +5 dBm +13 dBm Damage level Channel 1 120 V (dc + ac pk) linearly derated to 5 Vrms at 125 MHz

120 V (dc + ac pk) linearly

derated to 5 Vrms at 125 MHz derated to 5 Vrms at 125 MHz Channel 2 +27 dBm +27 dBm +27 dBm Impedance (nominal) Channel 1 1 MΩ/60 pF 1 MΩ/60 pF 1 MΩ/60 pF Channel 2 50 Ω 50 Ω 50 Ω Connector Channel 1 BNC female BNC female BNC female Channel 2 SMA/APC-3.5 compatible female SMA/APC-3.5 compatible female 2.92 mm removable, SMA/APC-3.5 compatible female SWR (typical) Channel 2 50–300 MHz 0.3–10 GHz 10–20 GHz 20–26.5 GHz 26.5–46 GHz 1.5:1 2.0:1 3.0:1 N/A N/A 1.5:1 2.0:1 3.0:1 3.0:1 N/A 1.5:1 2.0:1 3.0:1 2.5:1 2.5:1 Coupling Channel 1 ac ac ac Channel 2 ac ac ac

Counter specifications (continued) 53147A 53148A 53149A Emissions (typical) (“kickback noise”) Channel 1 N/A N/A N/A Channel 2 (measuring/no input) –40 dBm/< –70 dBm –40 dBm/< –70 dBm –40 dBm/ < – 70 dBm Resolution selection Channel 1 and 2 1 Hz to 1 MHz 1 Hz to 1 MHz 1 Hz to 1 MHz Accuracy Channel 1 and 2, LSD = resolution selected ± 1 LSD ± residual stability ± (timebase error x frequency) ± 1 LSD ± residual stability ± (timebase error x frequency) ± 1 LSD ± residual stability ± (timebase error x frequency) Residual stability (counter and source tied to same timebase) Channel 1 N/A N/A N/A Channel 2 0.6 LSD rms 0.8 LSD rms 1.25 LSD rms Measurement time (typical) Channel 1 1/resolution + 30 ms 1/resolution + 30 ms 1/resolution + 30 ms Channel 2 1/Resolution + Acquisition time + 30 ms 1/Resolution + Acquisition time + 30 ms 1/Resolution + Acquisition time + 30 ms Acquisition time (typical) (1 MHz FM rate, power meter off) Channel 1 N/A N/A N/A Channel 2 (FM Auto/FM Off) 150 ms/125 ms 150 ms/125 ms 165 ms/140 ms FM tolerance Channel 1 N/A N/A N/A Channel 2 FM Auto 20 MHz p-p max at 10 MHz rate 20 MHz p-p max at 10 MHz rate 20 MHz p-p max to 26.5 GHz,

12 MHz p-p max above

26.5 GHz at 10 MHz rate

Channel 2 FM Off 1 MHz p-p at 10 MHz rate 1 MHz p-p at 10 MHz rate 1 MHz p-p at 10 MHz rate AM tolerance Channel 1 and 2 Any index provided minimum signal level is not less than sensitivity Any index provided minimum signal level is not less than sensitivity Any index provided minimum signal level is not less than sensitivity Amplitude discrimination Channel 1 N/A N/A N/A Channel 2 < 300 MHz N/A N/A N/A Channel 2 > 300 MHz Automatically measures the largest signal present provided signal is > 10 dB (typical) above any signal separated by less than 75 MHz; > 20 dB (typical) above any signal separated by more than 75 MHz Automatically measures the largest signal present provided signal is > 10 dB (typical) above any signal separated by less than 75 MHz; > 20 dB (typical) above any signal separated by more than 75 MHz Automatically measures the largest signal present provided signal is > 10 dB (typical) above any signal separated by less than 75 MHz; > 20 dB (typical) above any signal separated by more than 75 MHz

Counter specifications (continued) Timebase Frequency 10 MHz Output 10 MHz sine wave, 1 Vrms into 50 Ω External timebase input 1, 2, 5, 10 MHz; 1 to 5 Vrms into 50 Ω Connector BNC female located on rear panel Internal timebase stability Aging rate per day Aging rate per month Short term (1 sec. average time) Line variation (± 10%) Warm-up Temperature stability (0–55 °C) TCXO (standard) N/A < 1 x 10–7 < 1 x 10–9 < 1 x 10–7 N/A < 1 x 10–6 Oven (Option 001) < 5 x 10–10 < 1.5 x 10–8 < 2 x 10–10 < 1 x 10–10 < 1 x 10–8 within 5 min. after turn-on at 25 °C < 1 x 10–8 Power meter specifications Frequency range 100 kHz to 50 GHz, sensor dependent. Power range –70 to +44 dBm, sensor dependent. Power sensors supported 8480 Series (see table on page 8) Resolution 0.01 dB in log mode, 0.1% of full scale in linear mode. Display units Absolute Relative dBm or Watts dB or % Accuracy Instrumentation Zero set (digital setting capability of zero) ± 0.02 dB or ± 0.5%. Add power sensor linearity specification for overall syst em accuracy. Sensor dependent (see table on page 8) Power reference Power output Accuracy Frequency Connector 1.00 mW. Factory set to ± 0.7%, traceable to NIST. ± 1.2% worst case (± 0.9 RSS) for one year

50 MHz (nominal)

N (f) DVM specifications Function DC volts Range ± 50 Vdc Resolution 2 mV Accuracy ± 0.25% of reading ± 10 mV Damage level ± 60 Vdc Input resistance 0.5 MΩ (nominal) Connector 4 mm banana sockets Display Replaces frequency display when DVM activated

Save and recall Up to 9 complete instrument setups may be saved and later recalle d. These setups are retained when power is removed. Sample rate User-selectable fast (nominally 20 ms between readings), m edium (nominally 250 ms between readings), slow (nominally 1 s between readings) and hold. Counter gate time 1/resolution selected Math functions Offset (relative/fixed) Averaging Last reading and/or entered offset to reading for either power or frequency 1 to 99 measurement running average Display Backlit LCD. Backlight can be turned on or off via front panel control. Sleep mode (Option 002 only) Backlight automatically shuts off if no input signal and power sensor prese nt, and no keys pressed, for 5 minutes (nominal). Self test Count and power meter circuitry and internal memory automatical ly tested at startup, via menu selection, or remotely. Error messages displayed to indicate failed te sts. Programming Interface Language RS-232 rates GPIB (IEEE-488.1-1987, IEEE 488.2-1987) and RS-232 SCPI-1992.0 (Standard Commands for Programmable Instruments) User selectable 2400 to 19200 baud Power supply ac Line selection Power requirements dc (Option 002 only) Battery (Option 002) Type Charge time Capacity 90–132 Vac; 47.5–66 Hz or 360–440 Hz 216–264 Vac; 47.5–66 Hz automatic 80 VA max. (32 W typical) 11–18 Vdc; 2A max. VHS camcorder, lead acid (2 each) 8 hours in unit (typical) 2 hours min. at 25 °C Size 330 mm W x 156 mm H x 376 mm D with bumpers and handles. Rack panel is full EIA width and 3U ISO height. Operating temperature With battery option 0–55 °C 0–40 °C Weight (nominal) 4.5 kg without battery option, 6.6 kg with battery option Warranty 1 year Safety Designed in compliance with IEC-1010, CAN/CSA 1010.1 EMC Designed in compliance with IEC-11, EN50082-1, IEC801-2, -3, -4 Accessories Supplied Power sensor cable (11730A) DVM test leads (34132B) Operating/programming and service manuals ac power cord Available Power sensors Spare battery dc power input cable

8480 Series (see table on page 8)

Keysight announced the discontinuance of the 848x “A,” “B” and “H” model pow er sensors that you may use with your counter. However, depending on your power measurement requirements , several of these sensor models can still be pur- chased from Keysight for use with your microwave frequency counter. www.keysight.com/find/contactus Available sensors Frequency range Connector Zero set

25 Watt sensors

1 mW to 25 W (0 to +44 dBm) 8481B 8482B

10 MHz to 18 GHz

100 kHz to 4.2 GHz N (m) N (m) ± 50 µW ± 50 µW

3 Watt sensors

100 µW to 3 W (–10 to +35 dBm) 8481H 8482H 100 kHz to 4.2 GHz N (m) N (m) ± 5 µW ± 5 µW 100 mW sensors 1 µW to 100 mW (–30 to +20 dBm) 8485A 8485A Option 033 8481A 8482A 8487A 50 MHz to 26.5 GHz

50 MHz to 33 GHz

100 kHz to 4.2 GHz

50 MHz to 50 GHz

APC-3.5 mm (m) APC-3.5 mm (m) N (m) N (m) 2.4 mm (m) ± 50 nW ± 50 nW ± 50 nW ± 50 nW ± 50 nW High sensitivity sensors 100 pW to 10 µW (–70 to –20 dBm) 8481D 8485D 8485D Option 033 8487D 50 MHz to 26.5 GHz N (m) APC-3.5 mm (m) APC-3.5 mm (m) 2.4 mm (m) ± 20 pW ± 20 pW ± 20 pW ± 20 pW

Ordering Information

53147A 20 GHz Counter/Power Meter/DVM 53148A 26.5 GHz Counter/Power Meter/DVM 53149A 46 GHz Counter/Power Meter/DVM Option 001 High Stability Oven Timebase Option 002 Internal Battery and DC Power Input Option 1CM Rackmount Kit (53147-67001) 53146A Soft Carrying Case for 5314xA Microwave Counters

www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/counters For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-01-14) 09 | Keysight | 53140 Series Microwave Counter, Power Meter and DVM in One Portable Package - Technical Overview This information is subject to change without notice. © Keysight Technologies, 1999 - 2014 Published in USA, July 31, 2014 5988-0300EN www.keysight.com