Recommended replacement products:
53200 Series RF and universal frequency counter/timers (Data sheet
publication number: 5990-6283EN)
02 | Keysight | 53131A/132A/181A Counters - Data Sheet Overview – 225 MHz bandwidth (optional 1.5, 3, 5, or 12.4 GHz) – 10- or 12-digit resolution with 1 s gate time – GPIB interface and IntuiLink connectivity software standard – Data transfer rate of up to 200 fully formatted measurements/second A family of universal and RF counters to meet your needs The Keysight Technologies, Inc. 53131A/132A/181A high-performance counters give you fast, precise frequency measurements at an affordable price. These counters feature an intuitive user interface and one-button access to frequently used functions so you can make accurate measurements quickly and easily. Real-time digital signal processing technology is used to analyze data while simultaneously taking new readings, speeding measurement throughput. The technology, developed for Keysight’s high-end line of modulation domain analyzers, allows the counters to gather more data for each measurement, so you get higher-resolution measurements in a fraction of the time it takes other counters. The 53131A/132A/181A counters offer built-in statistics and math functions so you can scale measurements and simultaneously measure and track average, min/max and standard deviation. Automated limit testing lets you set upper and lower limits for any measurement. An analog display mode lets you see at a glance whether a measurement is within pass/fail limits. The counters flag out-of-limit conditions and can generate an output signal to trigger external devices when a limit is exceeded. For quick access to frequently used tests, a single keystroke recalls up to 20 different stored front-panel set-ups. For computer-controlled systems applications, each counter includes a standard GPIB interface with full SCPI-compatible programmability and a data transfer rate of up to 200 fully formatted measurements per second. The standard RS-232 talk-only interface provides printer support or data transfer to a computer through a terminal-emulation program. Keysight 53131A universal counter The two-channel 53131A counter offers 10 digits per second of frequency/period resolution and a bandwidth of 225 MHz. Time interval resolution is specified at 500 ps. An optional third channel provides frequency measurements up to 3, 5, or 12.4 GHz. Standard measurements include frequency, period, ratio, time interval, pulse width, rise/fall time, phase angle, duty cycle, totalize, and peak voltage. Keysight 53132A universal counter For applications requiring higher resolution, the 53132A offers the same features and functions as the 53131A, with up to 12 digits/sec frequency/period resolution and 150 ps time interval resolution. In addition, the 53132A offers advanced arming modes for time interval measurements. Keysight 53181A RF counter Optimized for RF applications, the single-channel 10 digit/s 53181A measures frequency, period and peak voltage. A digit-blanking function lets you easily eliminate unnecessary digits when you want to read measurements quickly. For higher-frequency measurements, choose an optional second channel that provides measurements up to 1.5, 3, 5, or 12.4 GHz. A self-guided shallow menu makes this counter exceptionally easy to use.
03 | Keysight | 53131A/132A/181A Counters - Data Sheet Keysight IntuiLink provides easy access to the counter’s data from your PC The Keysight 53131A/132A/181A counters, capture precise frequency and time measurements. IntuiLink software allows that data to be put to work easily. You work in a familiar environment at all times, using PC applications such as Microsoft Excel or Word to analyze, interpret, display, print, and document the data you get from the counter. It gives you the flexibility to configure and run tests from your PC making data gathering more convenient. Keysight IntuiLink lets you: – Configure tests, including measurement type, number of readings, measurement speed, and more. – Choose display modes from real-time strip chart, histogram, readout, and table mode. – Scale measurements data. – Copy captured data to other programs. Optional timebases offer increased stability Optional timebases are available for 53131A/132A/181A counters to increase measurement accuracy. Option 010 provides a high stability oven timebase with aging of less than 5 x 10 -10 per day. 3-year warranty Each counter comes with operating, programming and service manuals, IntuiLink software, a power cord and a full 3-year warranty. Time base Internal time base stability (see graph 3 for timebase contribution of measurement error). Standard (0 to 50 °C) Medium oven (Option 001) High oven (Option 010) Ultra high oven (Option 012 for 53132A only) Temperature stability (referenced to 25°C) < 5 x 10-6 < 2 x 10-7 < 2.5 x 10-9 < 2.5 x 10-9 Aging rate (after 30 days) Per day < 4 x 10-8 < 5 x 10-10 < 1 x 10-10 Per month < 3 x 10-7 < 2 x 10-7 < 1.5 x 10-8 < 3 x 10-9 Per year < 2 x 10-8 Turn-on stability vs. time (in 30 minutes) < 2 x 10-7 referenced to 2 h < 5 x 10-9 referenced to 24 h < 5 x 10-9 referenced to 24 h Calibration Manual adjust Electronic Electronic Electronic Note that power to the time base is maintained when the counter is placed in standby via the front panel switch. The internal fan will continue to operate when in standby to maintain long-term measurement reliability.
04 | Keysight | 53131A/132A/181A Counters - Data Sheet Instrument Inputs Input specifications Channel 1 and 2 (53131A, 53132A) 1 Channel 1 (53181A) Frequency range DC coupled DC to 225 MHz AC coupled 1 to 225 MHz (50 Ω)
30 Hz to 225 MHz (1 MΩ)
FM tolerance 25% Voltage range and sensitivity (Sinusoid) 2 DC to 100 MHz 20 mVrms to ± 5 V AC + DC 100 to 200 MHz 30 mVrms to ± 5 V AC + DC 200 to 225 MHz 40 mVrms to ± 5 V AC + DC (all specified at 75 mVrms with option rear connectors) 3 Voltage range and sensitivity (Single-shot pulse) 2 4.5 to 10 ns pulse width 100 mVpp to 10 Vpp (150 mVpp with optional rear connectors) 3 > 10 ns pulse width 50 mVpp to 10 Vpp (100 mVpp with optional rear connectors) 3 Trigger level 2 Range ± 5.125 V Accuracy ± (15 mV + 1% of trigger level) Resolution 5 mV Damage level 50 Ω 5 Vrms 0 to 3.5 kHz, 1 MΩ 350 VDC + AC pk 3.5 to 100 kHz, 1 MΩ 350 VDC + AC pk linearly derated to 5 Vrms > 100 kHz, 1 MΩ 5 Vrms Input characteristics Channel 1 and 2 (53131A, 53132A) 1 Channel 1 (53181A) Impedance 1 MΩ or 50 Ω
1 MΩ capacitance 30 pF
Low-pass filter 100 kHz, switchable –20 dB at > 1 MHz Input sensitivity Selectable between Low, Medium, or High (default). Low is approximately 2x High Sensitivity. Trigger slope Positive or negative Auto trigger level Range 0 to 100% in 10% steps Frequency > 100 Hz Input amplitude > 100 mVpp (No amplitude modulation) Attenuator Voltage range x10 Trigger range x10 Input specifications 4 Channel 3 (53131A, 53132A) Channel 2 (53181A) Frequency range Option 015 (for 53181A only) 100 MHz to 1.5 GHz (see Option 030 for additional specs) Option 030 100 MHz to 3 GHz Option 050 200 MHz to 5 GHz Option 124 200 MHz to 12.4 GHz Power range and sensitivity (Sinusoid) Option 030 100 MHz to 2.7 GHz: –27 dBm to +19 dBm
2.7 GHz to 3 GHz: –21 dBm to +13 dBm
Option 050 200 MHz to 5 GHz: –23 dBm to +13 dBm Option 124 200 MHz to 12.4 GHz –23 dBm to +13 dBm Damage level Option 030 5 Vrms Option 050 +25 dBm Option 124 +25 dBm Characteristics Impedance 50 Ω Coupling AC VSWR < 2.5:1
05 | Keysight | 53131A/132A/181A Counters - Data Sheet Instrument Inputs (Continued) Input specifications 4 (Continued) Channel 3 (53131A, 53132A) Channel 2 (53181A) External arm input specifications 5 Signal input range TTL compatible Timing restrictions Pulse width > 50 ns Transition time < 250 ns Start-to-stop time > 50 ns Damage level 10 Vrms External arm input characteristics 5 Impedance 1 kΩ Input capacitance 17 pF Start/stop slope Positive or negative External time base input specifications Voltage range 200 mVrms to 10 Vrms Damage level 10 Vrms Frequency 1 MHz, 5 MHz, and 10 MHz (53132A 10 MHz only) Time base output specifications Output frequency 10 MHz Voltage > 1 Vpp into 50 Ω (centered around 0 V) 1. Specifications and characteristics for Channels 1 and 2 are identical for both common and separate configurations. 2. Values shown are for X1 attenuator setting. Multiply all values by 10 (nominal) when using the X10 attenuator setting. 3. When the 53131A or 53132A are ordered with the optional rear terminals (Option 060), the channel 1 and 2 inputs are active on both front and rear of the counter. When the 53181A is ordered with the optional rear terminal, the channel 1 input is active on both front and rear of the counter. For this condition, specifications indicated for the rear connections also apply to the front connections. 4. When optional additional channels are ordered with Option 060, refer to configuration table for Option 060 under ordering info on page 8. There is no degradation in specifications for this input, as applicable. 5. Available for all measurements except peak volts. External arm is referred to as external gate forsome measurements.
06 | Keysight | 53131A/132A/181A Counters - Data Sheet For automatic or external arming: (and signals < 100 Hz using timed arming) See graphs for worst case resolution performance. Frequency N For automatic arming: Gate time = where N = 1 for standard channel frequency < 1 MHz 4 for standard channel frequency > 1 MHz 128 for optional channel Trigger: Default setting is auto trigger at 50%. x Gate time tres Frequency or periodLSD displayed: 650 ps 53131A tres Typical 200 ps 53132A t res 650 ps 53181A t res x Frequency or periodRMS resolution: Gate time + (2 x Trigger error) 2t res 350 ps 1.25 ns 53131A tacc Typical Worst case 100 ps 500 ps 53132A t acc 350 ps 1.25 ns 53181A tacc x Frequency or periodSystematic uncertainty: ± Time base error ± tacc Gate time
07 | Keysight | 53131A/132A/181A Counters - Data Sheet For time or digits arming: Number of samples = Gate time × Frequency (Frequency < 200 kHz) Gate time × 200,000 (Frequency > 200 kHz) Trigger: Default setting is auto trigger at 50%. 100 ps 300 ps 53131A/81A tacc Typical Worst case 10 ps 100 ps 53132A t acc x Frequency or periodSystematic uncertainty: ± Time base error ± tacc Gate time See graphs for worst case resolution performance. Gate time tjitter Gate time tjitter Frequency or periodLSD displayed: 500 ps 53131A/181A t res Typical 50 ps tjitter 225 ps t res 3 ps 53132A tjitter x Frequency or period RMS resolution (see Graph 2): Gate time x Number of samples 2 2 tres Gate time x Number of samples + (2 x Trigger error )2t res 4 x x
08 | Keysight | 53131A/132A/181A Counters - Data Sheet Measurement Specifications Frequency (53131A, 53132A, 53181A) Channel 1 and 2 (53131A, 53132A) Channel 1 (53181A) Range 0.1 Hz to 225 MHz Channel 3 (53131A, 53132A) Channel 2 (53181A) Option 015 (53181 A only) 100 MHz to 1.5 GHz Option 030 100 MHz to 3 GHz Option 050 200 MHz to 5 GHz Option 124 200 MHz to 12.4 GHz (Period 2 or 3 selectable via GPIB only) Period (53131A, 53132A, 53181A) Channel 1 and 2 (53131A, 53132A) Channel 1 (53181A) Range 4.44 ns to 10 s Channel 3 (53131A, 53132A) Option 015 (53181A only) 0.66 to 10 ns Channel 2 (53181A) Option 030 0.33 to 10 ns Option 050 0.2 to 5 ns Option 124 80 ps to 5 ns Frequency ratio (53131A, 53132A, 53181A) Measurement is specified over the full signal range of each input. Results range 10–10 to 1011 “Auto” gate time 100 ms Time interval (53131A, 53132A) Measurement is specified over the full signal ranges 6 of Channels 1 and 2 Results range –1 ns to 10 5 s LSD 500 ps (53131A)/150 ps (53132A) Phase (53131A, 53132A) Measurement is specified over the full signal range of Channels 1 and 2 Results range –180° to +360° Duty cycle (53131A, 53132A) Measurement is specified over the full signal range of Channel 1. However, both the positive and negative pulse widths must be greater than 4 ns. Results range 0 to 1 (e.g. 50% duty cycle would be displayed as .5) Rise/fall time (53131A, 53132A) Measurement is specified over the full signal ranges of Channel 1. The interval between the end of one edge and start of a similar edge must be greater than 4 ns. Edge selection Positive or negative Trigger Default setting is auto trigger at 10 and 90% Results range 5 ns to 10 5 s LSD 500 ps (53131A)/150 ps (53132A) Pulse width (53131A, 53132A) Measurement is specified over the full signal range of Channel 1. The width of the opposing pulse must be greater than 4 ns. Pulse selection Positive or negative Trigger Default setting is auto trigger at 50% Results range 5 ns to 10 5 s LSD 500 ps (53131A)/150 ps (53132A) Totalize (53131A, 53132A) Measurement is specified over the full signal range of Channel 1. Results range 0 to 1015 Resolution ± 1 count Peak volts (53131A, 53132A, 53181A) Measurement is specified on Channels 1 and 2 for DC signals; or for ac signals of frequencies between 100 Hz and 30 MHz with peak-to-peak amplitude greater than 100 mV. Results range –5.1 V to +5.1 V Resolution 10 mV Peak volts systematic uncertainty (53131A, 53132A, 53181A) Use of the input attenuator multiplies all voltage specifications (input range, results range, resolution and systematic uncertainty) by a nominal factor of 10. For AC signals 25 mV + 10% of V For DC signals 25 mV + 2% of V
09 | Keysight | 53131A/132A/181A Counters - Data Sheet Measurement Specifications (Continued) Gate time Auto mode 1 ms to 1000 s Measurement throughput GPIB ASCII 200 measurements/s (maximum) Measurement arming Start measurement Free run, manual, or external Stop measurement Continuous, single, external, or timed Time interval 100 μs to 10 s (53131A) Delayed arming 100 ns to 10 s (53132A) Arming modes Note that not all arming modes are available for every measurement function 5. Available for all measurements except peak volts. External arm is referred to as external gate for some measurements. 6. See specifications for pulse width and rise/fall time measurements for additional restrictions on signal timing characteristics.
10 | Keysight | 53131A/132A/181A Counters - Data Sheet Systematic uncertainty: ± 2x resolution For measurements using Ch3, substitute Ch3 for Ch2 in these equations. To minimize relative phase measurement error, connect the higher frequency signal to channel 1. Time interval, pulse width, rise/fall time (53131A and 53132A only): Systematic uncertainty: ± (Time base error × Measurement) Trigger level timing error ± 1.5 ns Differential channel error (53131A) ± (Time base error × Measurement) Trigger level timing error ± 900 ps Differential channel error (53132A) where t res = 750 ps for the 53131A, 300 ps for the 53132A Phase (53131A and 53132A) 53132ASystematic uncertainty: – (± Trigger level timing error ± 1.5 ns Differential channel error) × Frequency × 360° (53131A) – (± Trigger level timing error ± 900 ps Differential channel error) × Frequency × 360° (53132A) Duty cycle (53131A and 53132A) RMS resolution: + Start trigger error(t )res 22 2 + Stop trigger error Frequency ratio: Ch1 Ch1 Ch2 Ch3 Ch2 Ch3 Ch1 Ch1 , , , (53131A and 53132A) Ch1 Ch2 Ch2 Ch1 (53181A) Ch2 Freq × Gate time 1LSD: Ratio :1 2(Ch1 Freq) × Gate time Ch2 FreqRatio :2 RMS resolution: Ratio :1 Ch2 Freq × Gate time 22 × 1 + (Ch1 Freq × Ch2 Trigger error) Ratio :2 2(Ch1 Freq) × Gate time 22 × Ch2 Freq × 1 + (Ch1 Freq × Ch2 Trigger error) RMS resolution: + (2 x Trigger error )( )(T )res 22 × Frequency × 360° 360° Phase1 +× RMS resolution: + (2 x Trigger error )( )(T )res 22 2× (1 + Duty cycle ) × Frequency 53131A 750 ps 53132A 300 ps tres
11 | Keysight | 53131A/132A/181A Counters - Data Sheet Auto arming Measurements are initiated immediately and acquired as fast as possible, using a minimum number of signal edges. Timed arming The duration of the measurement is internally timed to a user-specified value (also known as the “gate time”). Digits arming Measurements are performed to the requested resolution (number of digits) through automatic selection of the acquisition time. External arming An edge on the external arm Input enables the start of each measurement. Auto arming, timed arming modes or another edge on the external arm input may be used to complete the measurement. Time interval delayed arming For time interval measurements, the stop trigger condition is inhibited for a user-specified time following the start trigger. The 53132A offers advanced time interval arming capabilities including use of user specified time or Channel 2 events to delay both start and stop triggers. Measurement limits Limit checking The measurement value is checked against user-specified limits at the end of each measurement. Display modes The measurement result may be displayed as either the traditional numeric value or graphically as an asterisk moving between two vertical bars. Out-of-limits indications: – The limits annunciator will light on the front panel display. – The instrument will generate an SRQ if enabled via GPIB. – The limits hardware signal provided via the RS-232 connector will go low for the duration of the out-of-limit condition. – If the analog display mode is enabled, the asterisk appears outside the vertical bars, which define the upper and lower limits.
12 | Keysight | 53131A/132A/181A Counters - Data Sheet Fractional time base error (see Graph 3) Time base error is the maximum fractional frequency variation of the time base due to aging or fluctuations in ambient temperature or line voltage: Time base error = Aging rate Temperature+( )+ Line voltage f f f Multiply this quantity by the measurement result to yield the absolute error for that measurement. Averaging measurements will not reduce (fractional) time base error. The counters exhibit negligible sensitivity to line voltage; consequently the line voltage term may be ignored. Trigger error External source and input amplifier noise may advance or delay the trigger points that define the beginning and end of a measurement. The resulting timing uncertainty is a function of the slew rate of the signal and the amplitude of spurious noise spikes (relative to the input hysteresis band). The (rms) trigger error associated with a single trigger point is: Trigger error = Input signal slew rate at trigger point (in seconds) (E )input 2 + (E )signal where Einput = RMS noise of the input amplifier: 1 mVrms (350 µVrms typical). Note that the internal measurement algorithms significantly reduce the contribution of this term. Esignal = RMS noise of the input signal over a 225 MHz bandwidth (100 kHz bandwidth when the low-pass filter is enabled). Note that the filter may substantially degrade the signal’s slew rate at the input of the trigger comparator. For two-trigger-point measurements (e.g. rise time, pulse width), the trigger errors will be referred to independently as start trigger error and stop trigger error. Trigger level timing error (see Graph 6) Trigger level timing error results from a deviation of the actual trigger level from the specified level. The magnitude of this error depends on resolution and accuracy of the trigger level circuit, input amplifier fidelity, input signal slew rate, and width of the input hysteresis band. The following equations should be summed together to obtain the overall trigger level timing error. At the “High” sensitivity input setting, the hysteresis band can be assumed to be the sensitivity of the counter input (see page 4). Reduction of input sensitivity or use of the attenuator will increase the size of this band. Input hysteresis error: 0.5 x hysteresis band Input signal slew rate at start trigger point 0.5 x hysteresis band Input signal slew rate at stop trigger point Trigger level setting error: 15 mV ± (1% x start trigger level setting) Input signal slew rate at start trigger point 15 mV ± (1% x stop trigger level setting) Input signal slew rate at stop trigger point
13 | Keysight | 53131A/132A/181A Counters - Data Sheet Graph 1: Keysight 53131A/181A–Worst case RMS resolution 7 (Automatic or external arming) The graphs may also be used to compute errors for period measurements. To find the period error (DP), calculate the frequency of the input signal (F = 1/P) and find the frequency error (DF) from the chart. Then calculate the period error as: ∆P = × P F Graph 2: Keysight 53131A/181A–Worst case RMS resolution 7 (Time or digits arming) 1E + 02 1E + 00 1E – 02 1E – 04 1E – 06 1E – 08 1E – 10 10 100 1000 10000 1E + 05 1E + 06 1E + 07 1E + 08 1E + 09 1E + 10 Remarks: Auto armed Gate time: 1 ms 10 ms 100 ms 1 s 10 s Frequency error (Hz) Input frequency (Hz) E + 02 1E + 00 1E – 02 1E – 04 1E – 06 1E – 08 1E – 10 10 100 1000 10000 1E + 05 1E + 06 1E + 07 1E + 08 1E + 09 1E + 10 Remarks: Gate time: 1 ms 10 ms 100 ms 1 s 10 s Frequency error (Hz) Input frequency (Hz) Differential channel error The differential channel error term stated in several systematic uncertainty equations accounts for channel-to-channel mismatch and internal noise. This error can be substantially reduced by performing a TI calibration (accessible via the utility menu) in the temperature environment in which future measurements will be made.
14 | Keysight | 53131A/132A/181A Counters - Data Sheet Graph 3: Timebase error 7 Graph 4: Keysight 53132A–Worst case RMS resolution 7 (Automatic or external arming) 1E + 02 1E + 00 1E – 02 1E – 04 1E – 06 1E – 08 1E – 10 10 100 1000 10000 1E + 05 1E + 06 1E + 07 1E + 08 1E + 09 1E + 10 Remarks: Auto armed Gate time: 1 ms 10 ms 100 ms 1 s 10 s Frequency error (Hz) Input frequency (Hz) 10 kHz 1 kHz 100 Hz 10 Hz 1 Hz 100 mHz 10 mHz 1 mHz 100 µHz 10 µHz 1 µHz 100 nHz 10 nHz 1 Hz 1 ns 10 Hz 10 ns 100 Hz 100 ns 1 kHz 1 µs 10 kHz 10 µs 100 kHz 100 µs
1 MHz
10 MHz
100 MHz
1 GHz
Remarks: High stability T.B. 10 years after cal Medium stability T.B. 1 year after cal Standard stability T.B. 1 year after cal High stability T.B. 1 year after cal Standard T.B. 1 month after cal Medium T.B. 1 month after cal High stability T.B. 1 month after cal Ultra stability T.B. 1 year after cal Frequency error Time error Input signal frequency or time 10 µs 1 µs 100 ns 10 ns 1 ns 100 ps 10 ps 1 ps 100 fs 10 fs 1 fs 100 as 10 as
15 | Keysight | 53131A/132A/181A Counters - Data Sheet Graph 5: Keysight 53132A–Worst case RMS resolution 7 (Time or digits arming) Graph 6: Trigger level timing error (Level setting error and input hysteresis) E + 02 1E + 00 1E – 02 1E – 04 1E – 06 1E – 08 1E – 10 10 100 1000 10000 1E + 05 1E + 06 1E + 07 1E + 08 1E + 09 1E + 10 Remarks: Gate time: 1 ms 10 ms 100 ms 1 s 10 s Frequency error (Hz) Input frequency (Hz) 7. Graphs 1, 2, 4 and 5 do not reflect the effects of trigger error. To place an upper bound on the added effect of this error term, determine the frequency error from the appropriate graph and add a trigger error term as follows: Time or digit arming Frequency error x+ Frequency or period Gate time x Number of samples 4 x 2 x Trigger error Automatic or external arming Frequency error x+ Frequency or period Gate time 2 x Trigger error 100 µs 10 µs 1 µs 100 ns 10 ns 1 ns 100 ps 10 ps
1 V/ms 10 mV/µs 100 mV/µs 10 mV/ns 100 mV/ns 1 V/ns 10 mV/ps1 V/µs
Remarks: 200 to 225 MHz rep. rate 100 to 200 MHz rep. rate Pulse and T.I. at 5 V trigger point DC to 100 MHz rep. rate Pulse and T.I. at 2.5 V trigger point Pulse and T.I. at 0 V trigger point Trigger error per trigger point Input signal slew rate at trigger point
16 | Keysight | 53131A/132A/181A Counters - Data Sheet Measurement Statistics General Information
Description
Available statistics Mean, Minimum, Maximum, Standard Deviation Number of measurements 2 to 1,000,000 Statistics may be collected on all measurements or on only those which are between the limit bands. When the limits function is used in conjunction with statistics, N (number of measurements) refers to the number of in-limit measurements. In general, measurement resolution will improve in proportion to N, up to the numerical processing limits of the instrument. Measurements Statistics may be collected for all measurements except peak volts and totalize. Save and recall Up to 20 complete instrument setups may be saved and recalled later. These setups are retained when power is removed from the counter. Rack dimensions (HxWxD) 88.5 mm x 212.6 mm x 348.3 mm Weight 3.5 kg maximum Warranty 3 year standard Power supply 100 to 120 VAC ± 10% I 50, 60 or 400 Hz ± 10% 200 to 240 VAC ± 10% I 50 or 60 Hz ± 10% AC line selection Automatic Power requirements 170 VA maximum (30 W typical) Environment Storage temperature —40 °C to 71 °C Operating environment Pollution degree 2; indoor locations Operating temperature 0 °C to 55 °C Operating humidity Up to 80% at 40 °C Operating altitude Up to 3000 m or 10,000 ft. Remote interface GPIB (IEEE 488.1-1987 IEEE 488.2-1987) Remote programming language SCPI-1992.0 (Standard Commands for Programmable Instruments) Safety Designed in compliance with IEC-1010, UL-3111-1 (draft), CAN/CSA 1010.1 Installation Category II EMC CISPR-11, EN50082-1, IEC 80-2, -3, -4 Radiated immunity testing When the product is operated at maximum sensitivity (20 mVrms) and tested at 3 V/m according to IEC 801-3, external 100 to 200 MHz electric fields may cause frequency miscounts.
17 | Keysight | 53131A/132A/181A Counters - Data Sheet
Ordering Information
53131A 10 digit/s, 500 ps universal counter 53132A 12 digit/s, 150 ps universal counter 53181A 10-digit/s RF counter Accessories included Each counter comes with IntuiLink software, standard timebase, and power cord. CD with the following: IntuiLink software, Operating, Programming, Service and Getting Started Guides, a data sheet, and application notes. Manual options (Please specify one when ordering) ABA US English ABD German ABE Spanish ABF French ABJ Japanese ABZ Italian ABO Taiwan Chinese AB1 Korean AB2 Chinese Other options Option 001 Medium-stability timebase Option 010 High-stability timebase Option 012 Ultra-high stability timebase (53132A only) Option 015 1.5 GHz RF input Ch 2 for 53181A only Option 030 3 GHz RF input Ch 3 (Ch 2 on 53181A) Option 050 5 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A) Option 124 12.4 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A) Option 060 Rear-panel connectors 1 Option A6J ANSI Z540 compliant calibration 53131A/132A 1 Ch1 and Ch2 Front and rear (in parallel) Ch3 Option 030 rear only, front plugged Ch3 Option 050/124 front only Ch2 Option 050/124 front only 53181A 1 Ch1 Front and rear (in parallel) Ch2 Option 015/030 rear only, front plugged Ch2 Option 050/124 front only Accessories 34131A Hard carrying case 34161A Accessory pouch 34190A Rackmount kit: Designed for use with only one instrument, mounted on either the left or the right side of the rack. 34191A 2U dual flange kit: Secures the instrument to the front of the rack. This kit can be used with the 34194A dual lock link kit to mount two half-width, 2U height instruments side-by side. 34194A Dual lock link kit: Recommended for side-by-side combinations and includes links for instruments of different depths. This kit can be used with the 34191A 2U dual flange kit to mount two half-width, 2U height instruments side-by-side. 1. Option 060 configuration.
18 | Keysight | 53131A/132A/181A Counters - Data Sheet 374.0 mm 254.4 mm 103.6 mm 212.6 mm 348.3 mm 88.5 mm
This information is subject to change without notice. © Keysight Technologies, 2006 - 2016 Published in USA, October 11, 2016 5967-6039EN www.keysight.com 19 | Keysight | 53131A/132A/181A Counters - Data Sheet For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-16) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System Evolving Our unique combination of hardware, software, support, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. The business that became Keysight was a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Services www.keysight.com/find/service Our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. The result? We help you implement new technologies and engineer improved processes that lower costs. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/counters