365M ATC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Arrangement 30 & 50 Models When power is applied to terminals 1 & 2 and 15 of the timer, the instantaneous relay is energized and its contacts change state. The timer starts timing, indicated by the display. The timing bar “ ” blinks slowly and the digital display indicates elapse time (Timeup & Stop) or time remaining (Timedown & Stop). When the preset value is reached, the display stops, the timing bar blinks rapidly, the triangular timed-out symbol “ ” blinks, and the delayed relay latches and its contacts change state. The timer remains in this timed-out condition until reset by applying power to the Reset terminal 16 for at least 60 msec. At reset, both relays revert back to their shelf state (without power). Note 1: The delayed relay is a magnetic latch relay and once latched it will not unlatch even if power is removed or the unit is unplugged from the housing. It will only unlatch when power is momentarily applied to the Reset terminal 16. PANEL MOUNTED DIGITAL TIMERS 365M Series Long-Ranger Computing Timer with Memory Packaged in a 72mm2 DIN housing, the ATC 365 is a true plug-in timer that can be replaced in seconds without disturbing the mounting hous- ing or field wiring. Machine and process downtime is kept to a minimum. The 365M is also fully gasketed and O-ring sealed to be dust tight. WIDE RANGE: Each 365 timer covers the overall span of 0.01 SEC to 999 HR, in nine switch-selectable ranges of 9.99, 99.9, or 999 SEC, Min, or HR. EASY-TO-ADJUST PRESET: ATC’s unique three rotary switches for easy setting and adjustment of the preset time is an industry standard. The switches can be adjusted anytime, even during a timing cycle. The timer is constantly scanning the preset setting and instantly re-computes the time cycle if a preset change is detected. This is especially valuable in the Timedown mode allowing you to shorten or abort the current time cycle without the removal of power. SELF-CALIBRATING: The microprocessor automatically calibrates the timer for 50 or 60Hz power operation, there are no switches or jumpers to set. PROGRAMMABLE DISPLAY: An internal DIP switch can be set for Timeup or Timedown and Stop display operation on the Arrangement 30 model. The Arrangement 50 model can be set for Timeup or Timedown and go. There is a horizontal timing bar “ ” which appears to the right of the display and blinks once per second during timing and rapidly at time- out. At left, a timed out symbol “ ” blinks after time-out indicating when the magnetic delayed relay is latched. MAGNETIC LATCH RELAY: The 365 utilizes a unique magnetic latch delayed relay which energizes, latches, at time-out. Once latched it will not unlatch even with power removed or the unit is unplugged from the housing. It will only unlatch when power is momentarily applied to the Reset, terminal 16. NON-VOLATILE MEMORY: An EEPROM memory chip to retain the time value during a loss of power and continues timing when power is restored. No battery is required.

  • EEPROM Memory
  • Magnetic Latching Relay
  • Delayed & Instantaneous DPDT Contacts
  • Switch Selectable SEC, MIN or HR Ranges
  • Nine Ranges 0 to 9.99, 99.9 or 999
  • High Accuracy & Noise Immunity
  • Easy Plug-In Housing
  • High Intensity Blue Fluorescent Display
  • Fully Gasketed and O-ring sealed to be dust tight
  • Timeup or Timedown Display Operation
  • 50 or 60 Hz Operation Self-Adjusting OPERATION DIMENSIONS (INCHES/MILLIMETERS) 2.64 67.00 SQ. Panel Cutout Dimensions 1.50 38.10 1.10 27.95 5.31 134.87 2.60 66.00 PANEL THICKNESS 1/16" TO 3/16" DIMENSIONS: 3 6 5 2.83 72.00 SQ. 36 5 2.64 67.00 SQ. Panel Cutout Dimensions 1.50 38.10 1.10 27.95 5.31 134.87 2.60 66.00 PANEL THICKNESS 1/16" TO 3/16" DIMENSIONS: 3 6 5 2.83 72.00 SQ. 36 5 2.64 67.00 SQ. Panel Cutout Dimensions 1.50 38.10 1.10 27.95 5.31 134.87 2.60 66.00 PANEL THICKNESS 1/16" TO 3/16" DIMENSIONS: 3 6 5 2.83 72.00 SQ. 36 5 E48329

Automatic Timing & Controls 800.727.5646 atcdiversified.com MODEL NUMBER 365M P RANGE 0 to 9.99, or 99.9 or 999 SEC, 300 MIN, or HR Special 000 VOLTAGE & FREQUENCY

120 VAC 50-60 Hz Q

240 VAC, 50-60 Hz R

24 VAC, 50-60 Hz T

Selectable Timeup & Stop or Timedown & 30 Stop with Display, Standard Selectable Timeup & Stop or Timedown & 50 Go with Display, Standard

FEATURES

Accessories: Surface Mounting Bracket Kit 353-260-37-00 Retrofit Kit 305-265-61-70 PANEL MOUNTED DIGITAL TIMERS 365M Series SPECIFICATIONS WIRING MODELS Choice of two standard 120 VAC models Each model available in 240 VAC or 24 VAC 365M300Q30PX Timeup & Stop or Timedown & Stop, with display. 365M300Q50PX Timeup & Go or Timedown & Go, with display. RANGES Nine (9) Switch-Selectable ranges 0 - 9.99, 0 - 99.9, and 0 - 999 SEC, MIN, or HR MEMORY 100,000 read/write cycles RETENTION RESET TIME Guaranteed not to reset <20 mSEC Typical reset = 40 mSEC Guaranteed to always reset >60 mSEC DISPLAY Cycle Progress 3-digit high-intensity blue VF display, 0.3 inch Timing Bar: “ ” display; blinks once per second during timing, rapidly after time-out. Timed-Out Symbol: “ ”, blinks after time-out, blinks when latch relay is latched LOAD RELAYS Type DPDT, Form C Contact Rating 7 Amps @ 120 VAC, or 1/6HP @ 240 VAC Operate Release 10 mSEC max. Time Life 10 million operations (no load) TEMPERATURE 32 to 122°F (0 to 50°C) RATING POWER 120 VAC 50 or 60 Hz (10%, -20%) REQUIREMENTS Running <100mA @120VAC

240 VAC 50 or 60 Hz (10%, -20%)

Running <50mA @ 240 VAC

24 VAC 50 or 60 Hz (10%, -20%)

Running <300mA @ 24 VAC CLOCK INPUT 120 VAC 95 - 132 VAC, (Terminal 15) 10 mA max. current @ 120V

240 VAC 90 - 264 VAC,

10 mA max. current @ 240V 24 VAC 19.2 - 26.4 VAC, 20 mA max. current @ 24V TERMINALS 16 Screw (6-32) terminals with saddle clamps accessible at rear HOUSING 72mm 2 DIN size, Plug-in design, fully gasketed dust tight when panel mounted. Panel mounting bracket included. WEIGHT Net: 1 lb. 6 oz Shipping: 2 lbs. L1 to Power Supply 8 6 7 9 14 10 1 2 16 15 3 4 5 13 11 12 Power Supply Clock D2 D2D1 D1 I2 I2 I1 I1 Delayed ContactsInstantaneous Contacts L2 (common) L1 to clock Reset L1 to Reset 14 13 12 11 10 9 8 7 1 2 3 4 5 6 15 16 START RESET REAR OF HOUSING WHEN PANEL MOUNTED 365M ARRANGEMENT 30 OR 50 MODEL NUMBER Automatic Timing & Controls 800.727.5646 atcdiversified.com