Easy clamp current recording and convenient, low-cost voltage recording Extended recording of AC current and voltage transients Environmental Measuring Instrument HIOKI company overview, new products, environmental considerations and other information are available on our website. http://www.hioki.co.jp/ 3636-20 CLAMP LOGGER 500A AC 3637-20 AC VOLTAGE LOGGER 600V AC GGGG DDDDaaaattttaaaa bbbbaaaacccckkkkuuuupppp wwwwhhhheeeennnn bbbbaaaatttttttteeeerrrriiiieeeessss aaaarrrreeee eeeexxxxhhhhaaaauuuusssstttteeeedddd oooorrrr rrrreeeeppppllllaaaacccceeeedddd GGGG IIIInnnnssssttttaaaannnnttttaaaannnneeeeoooouuuussss////aaaavvvveeeerrrraaaaggggeeee rrrreeeeccccoooorrrrddddiiiinnnngggg ((((aaaavvvveeeerrrraaaaggggeeee oooovvvveeeerrrr rrrreeeeccccoooorrrrddddiiiinnnngggg iiiinnnntttteeeerrrrvvvvaaaallll)))) GGGG GGGGrrrraaaapppphhhhiiiicccc ddddiiiissssppppllllaaaayyyy ooooffff rrrreeeeccccoooorrrrddddeeeedddd ddddaaaattttaaaa tttthhhhrrrroooouuuugggghhhh aaaa ccccoooommmmppppuuuutttteeeerrrr GGGG EEEEqqqquuuuiiiippppppppeeeedddd wwwwiiiitttthhhh aaaallllaaaarrrrmmmm oooouuuuttttppppuuuutttt ((((3333666633336666----22220000))))
3911-20 COMMUNICATION BASE
9650 CLAMP ON SENSOR (100A)
9651 CLAMP ON SENSOR (500A)
9632 CONNECTION CABLE (included with the 3636-20, 1 m)
9639 CONNECTION CABLE (included with the 3637-20, 3 m)
9637 RS-232C CABLE (9 pin-to-9 pin, null modem, 1.8 m) 9638 RS-232C CABLE (9 pin-to-25 pin, null modem, 1.8 m) Recording capacity Communication type Power supply Maximum rated power Dimensions/mass Ambient use conditions Ambient storage conditions Accessories : Max 16,000 data points × 16 ch / 32,000 data points × 8 ch : Logger⇔ 3911-20: by infrared optical communication (with units in close contact) 3911-20 € PC: by RS-232C connection : LR03 (AAA) × 4 alkaline batteries : 0.2 VA : Approx. 69(W) × 92(H) × 36(D) mm, approx. 150 g : 0 to 40.0˚C, max 80% rh (no condensation) : -10.0 to 50.0˚C, max 80% rh (no condensation) : PC communication software I 3911-20 COMMUNICATION BASE Specifications I 3636-20/3637-20 Specifications I 9650/9651 Specifications I 3636-20/3637-20 Common Specifications Display Recording start Recording finish Recording interval Recording methods Recording modes Interface Power supply Maximum rated power Continuous use time Dimensions/mass Operating environment Ambient use conditions Ambient storage conditions Applicable standards : Measured value, recording status, recording interval, battery condition, unit, recording in progress, preset active, average value recording, maximum value, minimum value, alarm (3636-20 only) : Started manually or at preset time : Manual stop or until memory is full : One-time: Recording stops when memory becomes full. Endless: Oldest data is overwritten when memory becomes full. : Instantaneous value recording, average value recording (average over the recording interval) : Infrared optical communication (requires the 3911) : LR03 (AAA) × 4 alkaline batteries : 0.1 VA : About 1 year (with a recording interval of 1 minute and instantaneous value recording) About 1 month (with average value recording) : Indoors at an altitude of no more than 2000 m : 0 to 50˚C, less than 80% rh (no condensation) : -10 to 60˚C, less than 80% rh (no condensation) : EMC EN61326-1 : 1997+A1 : 1998 Safety EN61010-1 : 1993+A2 : 1995 Overvoltage category I (anticipated overvoltage: 330V), pollution index 2 (3636-20) Overvoltage category III (anticipated overvoltage: 6000V), pollution index 2 (3637-20) 3636-20 CLAMP LOGGER 3637-20 AC VOLTAGE LOGGER Input AC current AC voltage Number of input channels 2 channels 1 channel Measurement range 0.00 to 500.0 Arms.sin (50A/500A, 2 ranges) 0.0 to 600.0 Vrms.sin Accuracy (50/60 Hz, 23±5˚C) ±1% rdg. ±5 dgt. (logger only) Alarm output ON when set upper/lower limits exceeded None Measurement system True RMS calculation Accessories LR03 (AAA) alkaline batteries × 4, 9632 connection cord (for alarm output) LR03 (AAA) alkaline batteries ×4, 9639 connection cord (for input) × 9650 CLAMP ON SENSOR 9651 CLAMP ON SENSOR Rated primary current AC100A AC500A Accuracy (50/60 Hz, 23±5˚C) (where f.s. is rated primary current) (where f.s. is rated primary current) Frequency response
40 Hz to 1 kHz, within ±8% 40 Hz to 1 kHz, within ±3%
130A continuous (45 to 66 Hz) 600A continuous (45 to 66 Hz) Circuit voltage AC 300Vrms or less (insulated conductor) AC 600Vrms or less (insulated conductor) Measurable conductor diameter φ 15 mm or less φ 46 mm or less Cord length Approx. 3 m Approx. 3 m Dimensions/ mass Approx. 46(W) × 135(H) × 21(D) mm, approx. 200 g Approx. 77(W) × 151(H) × 42(D) mm, approx. 340 g Data recording capacity 32,000 data points (1 ch) 16,000 data points (2 ch) 32,000 data points Settings for communication software Current time, recording interval, recording start, recording method, comment, recording mode (3636-20/3637-20). Alarm and channel selection (3636-20 only) Communication software included with the 3911-20 Compatible OS: Windows 95/98/NT4.0 Functions G Graph display G Measurement data tabulation G Printing (data, graphs) G Scaling G File saving (in proprietary format or text format) The 3636-20 CLAMP LOGGER cannot be used for measurement by itself. A clamp-on sensor (sold separately) is required. Rated secondary current AC100mA AC500mA Options 3911-20 Communication Base, 9650/9651 Clamp-on Sensor 3911-20 Communication Base Analyze and Process Data on a Personal Computer The 3911-20 Communication Base is used to transfer data to a personal computer. The 3911-20 accommodates up to 16,000 points of 16-channel data or 32,000 points of 8-channel data. It captures data from multiple loggers, then transfers data to the computer where it can be analyzed and managed. 3911-20 LOGGER Infrared optical communication Approximately 500 data points/second (Logger and 3911 must be in direct contact for communication.) RS-232C Approximately 1000 data points/second True RMS calculation 9650 CLAMP ON SENSOR 9651 CLAMP ON SENSOR 9639 CONNECTION CABLE 9632 CONNECTION CABLE * 50A or 500A range when using the 9650, and 500A range when using the 9651 Windows is a registered trademark of Microsoft Corporation HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL+81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp F3636E1-04B-05P Printed in Japan DISTRIBUTED BY All information correct as of Apr. 7, 2000. All specifications are subject to change without notice. I Internet HIOKI website http://www.hioki.co.jp/ ASM GmbH Am Bleichbach 18 - 22
85452 Moosinning
Simple Leak Current Recording with Clamp On Sensors. Easy Logging at Low Cost Recording and Monitoring Leak Current G Select from three types of clamp on leak current sensors G Compact, light weight (130g), two-channel recording G High-capacity recording (32,000 data points) Recording interval: 15 steps from 1 second to 60 minutes G Accurate true effective value calculation even for distorted waveforms (100/1000 mA) G Maximum or average value recording (max./ave. within recording interval) G View recording data graphically on a PC G Data is protected during battery discharge and replacement HIOKI company overview, new products, environmental considerations and other information are available on our website. http://www.hioki.co.jp/ Model 9657 Model 9658 Model 9659
I HIOKI 3638-20 LEAK LOGGER Specifications Sensor models Inputs & ranges Combined accuracy at 50/60 Hz, 23 ±5˚C Recording modes Recording interval Recording data quantity Recording start / end Recording methods Max./Min. display Alarm output Backup Interface Power supply, consumption AAA-size alkaline batteries (LR03 × 4), 0.1 VA Serial infrared transfer Data backup is provided On when input crosses preset upper and lower limits (open-collector output) Maximum and Minimum values are displayed Single recording, Endless recording Manual, or at preset time / Manual, or when memory full 32,000 data points (single channel), 16,000 data points (for dual-channel recording) 1, 2, 5, 10, 15, 20 or 30 s, and 1, 2, 5, 10, 15, 20, 30 or 60 min. Maximum or average value with 9657or 9659sensor ±2% rdg. ±10 dgt. (100 mA range) ±2% rdg. ±6 dgt. (1000 mA range) with 9658sensor ±4.5% rdg. ±10 dgt. (100 mA range) ±4.5% rdg. ±6 dgt. (1000 mA range) 2 channels, 100.0 and 1000 mA (manual range selection) HIOKI 9657, 9658 and 9659 CLAMP ON LEAK SENSORS Instrument accuracy ±1% rdg. ±5 dgt. at 50/60 Hz, 23 ±5˚C, with built-in filter for 50/60Hz Continuous operating period One month (with power saver on, 1s measurement period) Ten days (with power saver off, 0.2s measurement period) (including batteries) Operating temperature & humidity 0 to 50˚C, 80% RH or less (noncondensing) I Clamp On Current Leak Sensor Specifications I HIOKI 3911-20 COMMUNICATION BASE Specification Recording capacity Up to 16,000 data points × 16 channels, Up to 32,000 data points × 8 channels Communication method Infrared between Leak Logger and 3911-20, RS-232C serial between 3911-20 and PC Power supply Four AAA size alkaline batteries (LR03 × 4) Size & weight Approx. 69(W) × 92(H) × 36(D) mm, approx. 150 g Supplied accessoriesPC communications software Supported operating systems Windows 9x, NT 4.0 Measurable conductor size Up to 40 mm dia. Rated primary current 1.0A AC Amplitude accuracy ±1.0% rdg. ±12 µV Residual current 5 mA (at 100A AC in) External magnetic field effect 5 mA equiv. With 400A/m (AC), 7.5 mA max. Voltage to ground 300 Vrms AC Insulation withstand voltage 3.7 kV (for 1 min.) Operating temp. & humidity 0 to 50˚C, 80% RH or less (non-condensating) Size & weight Approx. 74W × 145H × 42D mm, 340 g Up to 12 × 30 mm ±3.5% rdg. ±12 µV 1 mA (at 10A AC in)
150 Vrms AC
2.3 kV (for 1 min.) Approx. 65W × 52H × 18D mm, 50 g Up to 30 × 150 mm ±1.0% rdg. ±12 µV 30 mA (at 500A AC in)
460 Vrms AC
2.2 kV (for 1 min.) Approx. 358W × 108H × 48D mm, 2.5 kg Output voltage 25 mV/A AC Model 3638-20 LEAK LOGGER I Options Model 3911-20 COMMUNICATION BASE Model 9659 CLAMP ON LEAK SENSOR Model 9657 CLAMP ON LEAK SENSOR Model 9637 RS-232C CABLE (9-pin to 9-pin crossover, 1.8 m) Model 9658 CLAMP ON LEAK SENSOR Model 9638 RS-232C CABLE (9-pin to 25-pin crossover, 1.8 m) Model 9657 9658 9659 Cable length Approx. 3 m Supplied accessories AAA-size alkaline batteries (LR03 × 4), Model 9632 CONNECTION CABLE (for alarm output) Data Analysis and Processing on a PC Data can be transferred to a PC using the HIOKI 3911-20 COMMUNICATION BASE. Up to 16,000 data points can be collected from 16 channels, (or up to 32,000 data points can be collected from 8 channels), and then transferred to the PC for analysis and processing. Settings that can be made from communications software: current time, recording interval, recording start, recording methods, comment, recording mode, alarm, channel selection RS-232C Cable Measurement period 1 or 0.2 s (one channel only) Maximum allowable input 60A Continuous at 45 to 65 Hz 100A Continuous at 45 to 65 Hz10A Continuous at 45 to 65 Hz (Infrared transfer) HEAD OFFICE : TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp 363820E2-14M-05P Printed in Japan DISTRIBUTED BY All information correct as of Apr. 20, 2001. All specifications are subject to change without notice. I Internet HIOKI website http://www.hioki.co.jp/ ASM GmbH Am Bleichbach 18 - 22 NOTES: 1. Voltage to ground is that voltage between a power line and earth ground in a grounding- dependent electric circuit, or the voltage between one power line and any other power line in a grounding-independent circuit. 2. Coordination of Insulation: determination of the safe and appropriate characteristics of electrical insulation of wiring and connected devices according to the operating voltage. 3. Model 9658 is suitable for coordination of insulation with circuits of up to 150V voltage to ground, up to 240V for 3P3W lines, and up to 120/240V for 3P4W lines. 4. Models 9657 and 9659 are suitable for coordination of insulation with circuits of up to 300V voltage to ground, up to 500V for 3P3W lines, and up to 277/480V for 3P4W lines. COMMON ELECTRIC CIRCUITS and COORDINATION of INSULATION 3P-4W (3-phase, 4-wire) Voltage 3P-3W (3-phase, 3-wire) Voltage Voltage to Ground CATIII Recommended Impulse Withstand Voltage 120/208 V 120/240 V
240 V 150 V 2500 V
500 V 300 V 4000 V
(From EN61010-2-032, Annexes J, Table J.1) 3911-20 3638-20 3911-20