34205 MENDA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 1

Technical content

© 2024 DESCO INDUSTRIES INC Employee Owned

3651 WALNUT AVENUE, CHINO, CA 91710

PHONE: (909) 627-2453 WEBSITE: MENDATools.com DATE: April 2024 DRAWING NUMBER 34205 CONDUCTIVE C-TYPE CONNECTOR COVERS Made in the United States of America Chemical Susceptibility* Reactions Dilute Acids Slight Attack Dilute Alkalines Slight Attack Concentrated Acids Slight Attack Concentrated Alkalines Slight Attack Methanol, Ethanol, Isopropanol Resistant Hydrocarbons Slight Attack Ketones Slight Attack Oil and Gasoline Slight Attack Packaged 100/ pack; 10 packs/case 34205 10R 0.84" 0.5" 0.605" 0.665" 34206 10Y 0.75" 0.625" 0.53" 0.595" 34207 12R 0.97" 0.5" 0.72" 0.755" 34208 12Y 0.86" 0.625" 0.655" 0.715" 34209 14R 1.125" 0.5" 0.85" 0.905" 34210 14Y 1.031" 0.625" 0.785" 0.845" 34211 16R 1.22" 0.5" 0.973" 1.035" 34212 16Y 1.125" 0.625" 0.893" 0.963" 34213 18R 1.33" 0.562" 1.093" 1.155" 34214 18Y 1.25" 0.625" 1.03" 1.088" 34215 19R 1.4" 0.562" 1.125" 1.213" 34229 4R 0.67" 0.5" 0.25" 0.336" 34230 5R 0.67" 0.5" 0.313" 0.399" 34231 6R 0.67" 0.5" 0.375" 0.461" 34233 8Y 0.67" 0.625" 0.413" 0.483" Packaged 50/pack; 10 packs/case 34216 20R 1.465" 0.562" 1.231" 1.301" 34217 20Y 1.406" 0.625" 1.15" 1.215" 34218 22R 1.59" 0.562" 1.34" 1.41" 34219 22Y 1.5" 0.625" 1.27" 1.34" 34220 24R 1.7" 0.562" 1.463" 1.533" 34221 24Y 1.64" 0.625" 1.39" 1.46" 34222 25Y 1.81" 0.625" 1.54" 1.58" 34223 28R 1.95" 0.562" 1.715" 1.79" 34224 28Y 1.875" 0.625" 1.645" 1.718" Conductive C-Type Connector Cover Features: Conductive Composite Permanently volume conductive and free of carbon black particulate. The connector covers do not leave black marks and are more suited to clean situations. Meets the requirements of NASM5501 31/32. Noncorrosive Connector covers are noncorrosive and produce no visible corrosion when tested to Federal Test Method 101C using Kovar test plates. Conformability The polyethylene material used in the covers was selected for its resilience. Properly sized, the covers provide a snug, secure fit. This helps keep connectors clean and prevents the cover from accidentally falling off. Specifications and procedures subject to change without notice. “It should be understood that any object, item, material or person could be a source of static electricity in the work environment. Removal of unnecessary nonconductors, replacing nonconductive materials with dissipative or conductive materials and grounding all conductors are the principle methods of controlling static electricity in the workplace, regardless of the activity.” [ESD Handbook ESD TR20.20; section 2.4 Sources of Static Electricity] Tolerances: "A": ± .031" "B": ± .031" "C": ± .010" "D": ± .010" Packaged 25/pack; 10 packs/case 34225 32R 2.22" 0.562" 1.965" 2.04" 34226 32Y 2.125" 0.625" 1.89" 1.97" 34227 36R 2.435" 0.6" 2.215" 2.29" 34228 36Y 2.34" 0.625" 2.14" 2.21" “A” “B” “C” “D” *ASTM F925 Material Properties Test Method Typical Value Resistivity ASTM D991 <105 ohms Contact Corrosivity FTM 101C Method 3005 (Kovar plate) Pass Elongation ASTM D638 24% Tensile ASTM D638 2700 psi Vicat Softening ASTM MD 1525 85° C Outgassing ASTM E595 Pass Silicone Silicone free Maximum Temp. Exposure 180° F