3331 ASM-SENSOR | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Accurate evaluation of consumption power of electrical products Power measuring instruments 3332: Single-phase, 2-wire type that can accurately measure even standby power 3331: Single-phase, 3-wire and three-phase, 3-wire type for measuring power of large-scale equipment 3331, 3332 POWER HiTESTER As efficient use of energy for household and office equipment becomes more and more essential, the new 3332 POWER HiTESTER does the job by offering a wide range of power measurement from standby to normal usage. The 3331 POWER HiTESTER is capable of evaluating 3-phase devices, such as industrial air conditioners and refrigerators, or single-phase, large-scale devices. Both power testers deliver high accuracy of ±0.2% (45 to 66Hz), direct input up to 50A, and a broad bandwidth from 1Hz (the 3331 from 10Hz) to 100kHz. System construction is made easy with these compact, lightweight and reasonably priced tools, which come equipped with an external interface as a standard feature. The 3331 and 3332 can be used as a measuring component for a wide range of purposes, from research and development to equipment evaluation. An Energy Saving Support Tool
Measurement from minute single-phase power to large-scale 60 kW 3-phase equipment. The 3332 covers a wide range of power measurement A single-phase power meter compatible with devices with intermittent oscillation in broadband starting from 1Hz. The 3331 is compatible from single-phase to 3-phase devices V oltage/Current can be viewed for each phase of the 3-phase line ❑ Range Table U I The values in the shaded areas show the common range for the 3331 and 3332. Values in the ( ) show the range of the 3-phase, 3-wire mode and the single-phase, 3-wire mode (SUM display) of the 3331. For apparent power and reactive power, the unit of watts in the above table is replaced by V A and var respectively. 150.00V 150.00 mW 300.00 mW 200.00mA 3.0000 W 6.0000 W 12.000 W 30.000 W 120.00 W 60.000 W U I Model 3332 3331 Measurement line 1ø2W only 1ø2W to 3ø3W U Range 15 to 600V (6 ranges) 150 to 600V (3 ranges) I Range 1m to 50A (15 ranges) 500m to 50A (7ranges) Frequency characteristics 1Hz to 100kHz 10Hz to 100kHz Dimensions Approx. 210W ✕100H ✕261D mm from standby to usage
- High basic accuracy of ±0.2% More precise measurement non possible with a basic accuracy of ❑ Systems can be easily constructed
- A compact design that fits a half-rack (rack-mount models also available at special order)
- GP-IB / RS-232C: Data can be transferred to a printer or computer for efficient data management.
- EXT.I/O (External input/output terminal): External control of integration START/STOP, and analog/monitor/D/A output can be performed for voltage/current/power parameters.
- Simultaneous integration of current and power at a 6-digit high-resolution state A maximum of ±999999 (MWh or MAh) or up to a maximum of 10000 hours (416 days) of integration.
- Responsitivity that follows transient power fluctuations A achieve responses under 0.2 seconds for measurements of transient power fluctuations (Response speed set at FAST). ❑ Evaluation of electric equipment such as inverters Basic Performance of the 3331/3332 Basis of calculation U, I, and P respectively indicate measured values of voltage, current, and active power. However, values are not rounded for display (error: ±1 dgt.). s indicates phase polarity, and is -1 when the current phase leads voltage, and +1 when it lags voltage. 3332 3331
- Measuring the effective value of basic wave components only The average rectified effective value indicator method with a 500Hz low-pass filter can be selected.
- Current waveform peak measurement function The current waveform wave peak value and the maximum effective value can be detected. Voltage*1 / Current / Active power 1Hz to 2Hz*2*3 ±12%f.s. ➞ 20Hz to 30Hz*2*5 ±0.5%f.s. ➞ *1 V oltage accuracy is the same as when current input is less than 20A. *2 Measurement accuracy when response time is set to SLOW. *3 Accuracy guaranteed for the 3332 only. *4 V oltage/current accuracy for the 3331 is ±2.0% f.s. *5 V oltage/current accuracy for the 3331 is ±1.0% f.s. *6 Guaranteed accuracy for the 3331 is ±2.0% f.s. *7 Current is defined for 10A and less. Input current 20 A or less 20A to 30A 10kHz to 20kHz ±2.0%f.s. undefined 10Hz to 20Hz*2*4 ±1.0%f.s. ➞ Calculations of the 3331 3-phase, 3-wire mode are as follows in the table below. However, only SUM is displayed. Calculations for the 3332 follow the values for ch 1 in the table below. 20kHz to 50kHz ±5.0%f.s. undefined (at 23˚C±5˚C (73˚F±9˚F), 80% rh sine wave input, power factor = 1, after 30 minutes warming-up time.) 3331: 23˚C±3˚C (73˚F±5.4˚F) Accuracy 50kHz to 100kHz*7 ±15.0%f.s. undefined undefined undefined undefined ±0.2%f.s. undefined undefined undefined 30A to 50A undefined undefined undefined undefined undefined undefined
- 50A direct input Measurement of large capacity equipment possible.
- Broadband feature compatible with frequency control devices Wide range from 1Hz (the 3331 from 10Hz) to 100kHz is included for supporting measurement of inverters. Frequency ch Reactive power (Q ) Power factor (λ) Phase angle (ø) Active power (P ) SUM Apparent power (S ) (Period for which accuracy is guaranteed: 6 months) 5Hz to 10Hz*2*3 2Hz to 5Hz*2*3 ±1.5%f.s. ±5%f.s. undefined undefined
- Measurement of rush current during device start-up Measurement of the current waveform wave peak is possible, and if the peak hold function is used, wave peak detection of the motor rush current waveform (Max. 90A) and the maximum value of the effective value can be done. ❑ Common features of the 3331 and 3332 Applications that efficiently evaluate From minute standby power to rush current for motors electrical equipment
- Measurement of the RMS value for industrial frequency components. The average rectified effective value indicator method (MEAN) with 500Hz low-pass filter is employed to measure basic wave RMS values of PWM voltage form inverters.
- Understanding consumptive and regenerative conditions
- 3-phase line imbalance can be checked The third phase voltage and current that had not been measured for 2-power measurement systems (2 voltage/2 current) can be calculated by vector calculation and displayed.
- Comparative decision function that can be used on the production line Two items can be chosen from among voltage, current, power (active, reactive, apparent), peak current, power factor, phase angle, frequency and integration value for simultaneous comparative decisions. In addition to Hi/In/Lo LED lamps, decision results are output to contact points. Up to 10 conditions can be stored, a powerful function to reduce repetitive steps on small output/multi-product lines. ❑ Special Features of the 3332 ❑ Special Features of the 3331
- Precise calculations of minute standby power When the 150V/1.0000mA range is selected, integration from ±000.000mWh can be performed. Low numbers/units are automatically switched to a 6-digit display, allowing measurement in high resolution. Comparator setting screen RMS response at 0.2 sec. Comparative value setting Comparator decisions Measurement valueOther parameters Integration progress time Current integration display Active power integrationOther parameters U1 voltage display U3 voltage display U2 voltage display Average voltage display for each phase Integration progress time Consumptive element (+) integration value Total (±) integration value Note) Ranges for each channel cannot be independently set. Comparison of voltage display values of RMS and MEAN with the low-pass filter RMS display of PWM voltage waveforms. MEAN display of voltage waveform after filtering. Regenerative element (-) integration value
- The 3331 can be used to measure single - phase power for 2 devices Two devices with single-phase, 2-wire loads can be simultaneously measured, contributing to lower facilities cost.
- Measurement of standby power under 1W Current input 1W or less can be precisely measured (guaranteed accuracy range is from 7.5mW) by employing the CT method (input resistance under 2mΩ) for minimal instrument damage for current input, and with 150.000mW (150V-1mA range) in full scale as the highest sensitivity range for 100V devices. In addition, with guaranteed accuracy from 1Hz, the 3332 is also compatible with intermittent oscillating devices, such as videos. Integration display screen Consumptive (+), regenerative (-), and total power integration values can be simultaneously measured on equipment that regenerate power.
Keeping standby power of household electrical equipment in the range of 1W and below Example of chart calculation operation with EXCEL* The 3331 and 3332 are equipped with the GP-IB and RS-232C interfaces as standard features, allowing complete control from a computer (except for turning the power supply ON/OFF). In addition, measurement data can be directly downloaded into commercially available spreadsheet software on a computer using application software, making the troublesome creation of test result charts easy, and supporting effective data management. *EXCEL is a registered trademark of Microsoft Corporation. Raising the efficiency of electrical energy consumption to meet the needs of the time Energy Star Program The 1995-10 International Energy Star Plan is a program developed between the United States and Japan with the goal of universally advancing energy efficient office products, such as copy machines, printers, and fax machines. A plan for reducing contributions to global warming by raising the efficiency of electrical energy used by household and office equipment must take standby power into consideration. In the Japanese domestic market, precise measuring of minute standby power is needed, especially for manufacturers of audio/video devices, in order to follow a policy of keeping standby power under 1W. Application example using the GP-IB/RS-232C interface
Please refer to the separate MEMORY HiCORDER catalogs 3-phase voltage/current monitor output (for the 3331) ❑ Application example of monitor, analog, and D/A output The 3331 and 3332 are capable of simultaneous output of voltage and current waveforms as well as the active power level, and when connected to a HIOKI MEMORY HiCORDER or Hybrid Recorder, events ranging from long-term fluctuations to transient phenomena (only with MEMORY HiCORDERs ) can be recorded. Select one other measurement item (apparent power/reactive power/power factor/integration power capacity/frequency, etc.) to output from the D/A to conveniently record long-term fluctuations. Fluctuation state analyzed in clear waveforms. Phase difference between voltage and current/Correlation function with other parameters To record monitor / analog / D/A output Recording is made easy with the trigger function in the MEMORY HiCORDER , which records the rush current when a device is started, and with the recording mode, records fluctuations of power/integration values/frequency. Examination and analysis of correlation functions for each factor, including temperature, is another strong feature. 8826 Recording to a B5-width printer for a maximum of 32 channels Recording to a A4-width printer up to a maximum of 16 channels (8 channels with the 8841) 8835-01 Waveform recorder for a maximum of 8 channels A compact waveform recorder the size of a B5 piece of paper for recording in 2 or 4 channels 0.2 seconds Input voltage RMS value response Analog output response of the 3331/3332
❑ Dimensional drawing Orders also accepted for units equipped for rack mounting. Please inquire for details. 3332 3331 ❑ Basic specification Measurement range Number of measurements Measurement range Measurement range Number of channels Effective input range Measurement range Measurement items Number of channels Output resistance Output content Output voltage Output update rate GP-IB RS-232C : By 1-page range table : 5 times/sec : 0.00000 to 999999 MAh/MWh (integration time up to 10,000 hours) : -1.0000 (lead) to 0.0000 to 1.0000 (lag) -180˚(lead) to 0.00˚ to 180.00˚ (lag) : 1 ch : 3332; 1 Hz to 100 kHz, 3331; 4 Hz to 50 kHz : Auto, 500 Hz, 100 kHz (3331; up to 50 kHz) : Displays maximum absolute current value : 1 ch (15 bit D/A converter, polarity + 11 bits) : 100Ω±5% : V oltage, current, active / apparent / reactive power, power factor, phase angle, wave peak, frequency and the integrated value for each channel or sum of the values : DC±5V/f.s. : 5 times/sec : Conforms to IEEE-488.1 1987, with reference to IEEE-488.2 1987 : Start-stop synchronous, with baud rate of 1200 to 9600 bits/sec : External control, Display hold function, maximum value hold, current peak hold, data backup function, key lock function ❑ Measurement accuracy (at , max 80% rh, with warm-up time of at least 30 minutes, sine wave input, power factor = 1, and in-phase voltage 0) Thermal coefficient Effect of max. rated voltage to earth in-phase voltage Effect of power factor Effect of external magnetic field Real time D/A output Analog output Monitor output : Less than ±0.05%f.s. (AC 600 V rms, 50/60 Hz applied between all input terminals and ground) : Less than ±0.4%rdg. (at 45 to 66 Hz, power factor = 0.5) Less than ±0.23%f.s. (at 45 to 66 Hz, power factor = 0) : ±1.5%f.s. (at AC 400 A rms/m, in 50/60 Hz magnetic field) : ±100ppm±1 sec (at 0 to 40˚C (32˚F to 104˚F)) : Measurement accuracy±0.2% f.s. : Measurement accuracy±0.2% f.s. (below 45 Hz with SLOW setting) : Measurement accuracy±0.1% f.s. V, A, W Apparent / reactive power Integration Power factor Phase angle Frequency Wave peak : Per accuracy table on page 2 : ±1 dgt. with respect to calculation from measured value (U,I,P) sum value is max. ±3dgt. : ±1 dgt. with respect to calculation from measured value (I,P) : ±1 dgt. with respect to calculation from measured value (U,I,P) : ±1 dgt. with respect to calculation from measured value (U,I,P) : ±0.1% rdg.±1dgt. : Measurement accuracy ±1% f.s.(current peak range) Current peak range: Current range ✕ 6 [Integration measurement] [Power factor/phase angle measurement] [Frequency measurement] [Wave peak measurement] [Interfaces] [Other functions] [D/A output] Measurement line Measurement item Display indication range Display Display resolution Rectification method Display update rate Analog response time Input resistance (50/60 Hz) Max. input voltage Max. input current Max. rated voltage to earth Crest factor Analog output Monitor output Scaling Averaging Comparator (3332 only) Setting items Decisions : 3332: single-phase, 2-wire 3331: single-phase, 3-wire; 3-phase, 3-wire; single- phase, 2-wire (channel ranges cannot be independently set) : V oltage, current, current peak, active power, apparent power, reactive power, power factor, phase angle, frequency, power integration, current integration : 0.1% to 130% of range (zero-suppressed for less than 0.1%) (3332; zero-suppressed for less than 0.2% of V range and 40µA) 3332: V oltage, current, power; Effective input range : 5% to 120% of measurement range (5% to 100% of 600V range only) 3331: V oltage, current, power; Effective input range : 1% to 120% of measurement range (1% to 100% of 600V range only) : Digital display LED, displays 4 items : 99999 counts (other than integration), 999999 counts (integrated value) : Switchable between RMS (true root mean square value) and MEAN (average rectified RMS indication). With voltage only, cutoff frequency is 500 Hz. : Approx 5 times/sec : FAST (0.2 sec) or SLOW (1.6 sec) (3332; at SLOW 5sec) (Time to enter accuracy range upon sudden change from 0 to 90% or 100 to 10%) : V oltage 2MΩ±10% Current Less than 2mΩ : V oltage 600 Vrms, 1100 V peak : Current 60 Arms, 90A peak : 600 Vrms, 50/60 Hz : V oltage (measurement range ✕ 6) / Measured value or 1100 V / measured value, whichever is lower Current (measurement range ✕ 6) / Measured value or 90 A / measured value, whichever is lower : Simultaneous output of voltage, current, active power DC±5V f.s. : Simultaneous output of voltage and current 1 Vrms f.s. : PT/CT/SC ratio Set range 0.001 to 9999 (3331; PT/CT only) : Moving average of sampling data is taken for display (1 (off), 8, 16, 32, 64 times) (3332; 1 to 300 times) : 2 ch (with ON/OFF function) : One item from among voltage/current/active, apparent, reactive power/power factor/phase angle/ frequency/waveform peak/integration value selected for one channel, Hi and Lo level set. : Decision and relay output (30V/0.5A) in Hi/In/Lo LED lamps. Relay Hold is possible from external control. [Voltage/current/power measurement] Location for use Ambient use humidity Ambient storage humidity Insulation resistance Withstand voltage (50/60 Hz, 1 minute) Certifications Power supply Maximum rated power Dimensions and mass Accessories : Indoors, altitude to 2000 m : 0˚C to 40˚C (32˚F to 104˚F), max 80% rh (no condensation) : -10˚C to 50˚C (14˚F to 122˚F), max 80% rh (no condensation) : 100MΩ or greater at DC 500 V Between voltage/current terminals and case, output terminals and external control terminals, voltage / current terminals and power supply, voltage term- inals and current terminals, individual channels, and power supply and case : AC 3.32 kV between voltage/current terminals and case, output term- inals and external control terminals, and between individual channels : Safety EN61010-1:2001 (V oltage and current input) Pollution factor, 2, overvoltage category III, Anticipated transient overvoltage 6000V (Power supply) Pollution factor 2 Overvoltage category II, Anticipated transient overvoltage 2500V EMC EN61326:1997+A1:1998+A2:2001 Class A : AC100V to 240V 50/60 Hz (universal power supply) : 3332; 40V A max. 3331; 50V A max. : 3332; Approx 210 W ✕ 100 H ✕ 261 D mm, 2.7 kg 3331; Approx 210 W ✕ 100 H ✕ 261 D mm, 2.5 kg (Not including projections such as terminals, feet, and handles) : Power cord 1, Ext I/O male connector 1 ❑ General specifications mass: Approx 2.5 kg (88.2 oz.) (8.3") (10.3") (1.2")(0.3") (3.9") (0.6") mass: Approx 2.7 kg (95.3 oz.) (8.3") (10.3") (1.4")(0.3") (3.9") (0.6") (Period for which accuracy is guaranteed: 6 months)
3331 POWER HiTESTER
(Single-phase, 3-wire and three-phase, 3-wire type)
3332 POWER HiTESTER
(Single-phase, 2-wire type)
3193 POWER HiTESTER
❏Related products Option
9442 PRINTER
9443-01 AC ADAPTER (For printer, Japan) 9443-02 AC ADAPTER (For printer, EU) 9443-03 AC ADAPTER (For printer, America)
9444 CONNECTOR CABLE
(For printer)
1196 RECORDING PAPER (For printer, 10rolls)
9151-02 GP-IB CONNECTION CABLE (2m (79")) 9151-04 GP-IB CONNECTION CABLE (4m (158")) Please request a 9444 CONNECTOR CABLE for connecting to the 3331/3332 unit and the 9443 AC ADAPTER when purchasing the 9442 PRINTER. ■ Basic specification : Single-phase, 2-wire; single-phase, 3-wire, 3-phase, 3-wire; 3-phase, 4-wire : [When used with 9600, 9601, 9602 (option)] v oltage, current, voltage and current waveform peak, active/ reactive/apparent power, power factor, phase angle, frequency, current and power integration; load factor; efficiency [When 9603 is used (option/above functions plus functions written below)] voltage, torque, rotation count, frequency, motor output [When 9605 is used (option/all functions above plus functions written below)] harmonics, waveform, voltage fluctuation/flicker : voltage: 6/15/30/60/150/300/600/1000V current: 200/500 mA/1/2/5/10/20/50A power: 1.2 W to 150 kW (with measurement mode and voltage, current, range combination) frequency: 50/500/5 k/50 k/2 MHz : 8 times/s : 9600: broadband unit from DC/0.5 Hz to 1 MHz 9601: AC-only unit from 5 Hz to 100 kHz 9602: Clamp input-only unit from DC/0.5 Hz to 200 kHz : Waveform peak measurement, efficiency measurement, D/A output, FDD, external control, scaling, average, backup function, motor output (Pm) measurement (9603 option), miscellaneous : AC100/120/200/230V automatic switching, 50/60 Hz, 150 V A max. : 430 W ✕150 H ✕370 D mm; 13 kg Measurement line Measurement item Measurement range (when used with 9600) W basic accuracy Display update Frequency quality (by unit) Functions Power supply Dimensions and Mass Measurement cannot be done with the 3193 unit alone. Optional input units are necessary for measurement. For more details, please request the 3193 product catalog. : Thermal serial dot matrix : 112 mm (4.5") : 52.5cps : 9443 AC ADAPTER or supplied nickel-hydride battery (capable of printing about 3000 lines on full charge from 9443) : Approx. 160W ✕ 66.5H ✕ 170D mm; 580 g Printing method Paper width Printing speed Power supply Dimensions and mass approx. 1.5m (60")
9443 AC ADAPTER
(For the EU) 9443-01 (For Japan) Broad bandwidth from DC/0.5 Hz to 1 MHz Power measurement tool that supports integrated evaluations of electrical devices
- In addition to basic measurement, it comes with more advanced measurement of motor power/efficiency/ harmonics /flicker (Some functions require separate options)
- Three types of input units can be chosen for application
- Simultaneous measurement of up to six lines
- Three types of input units can be chosen for application HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com DISTRIBUTED BY All information correct as of Apr. 7, 2006. All specifications are subject to change without notice. 3330SE4-64B-03K Printed in Japan Shanghai Representative Office :
1310 Shanghai Times Square Office
93 Huaihai Zhong Road
Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: info@hioki.cn