10 MHz Function/Arbitrary Waveform Generator

– 10 MHz Sine and Square waveforms – Pulse, Ramp, Triangle, Noise, and DC waveforms – Optional 14-bit, 50 MSa/s, 8K point Arbitrary Waveform Generator – AM, FM, and PWM modulation types – Linear & logarithmic sweeps and burst operation – 10 mVpp to 10 Vpp amplitude range –Graph mode for visual veriication of signal settings – Connect via USB, GPIB and LAN –Fully compliant to LXI Class C speciication

Measurement Characteristics Waveforms Standard Sine, Square, Ramp, Triangle, Pulse, Noise, DC Built-in arbitrary wave- forms (available only with Option 002 ARB) Exponential rise, Exponential fall, Negative ramp, Sin(x)/x, Cardiac Waveform characteristics Sine Frequency range 1 mHz to 10 MHz Amplitude Flatness 1, 2 (relative to 1 kHz) < 100 kHz 0.1 dB 100 kHz to 5 MHz 0.2 dB 5 MHz to 10 MHz 0.3 dB Harmonic distortion 2, 3 < 1 Vpp ≥ 1 Vpp DC to 20 kHz –70 dBc –70 dBc 20 kHz to 100 kHz –65 dBc –60 dBc 100 kHz to 1 MHz –50 dBc –45 dBc

1 MHz to 10 MHz –40 dBc –30 dBc

Total harmonic distortion 2, 3 DC to 20 kHz 0.04% Spurious (non-harmonic) 2, 4 DC to 1 MHz –70 dBc

1 MHz to 10 MHz –70 dBc + 6 dB/octave

(10 kHz offset) –115 dBc / Hz, typical Square Frequency range 1 mHz to 10 MHz Rise/fall time 20 ns Overshoot < 2% Variable duty cycle 20% to 80% (to 5 MHz) 40% to 60% (to 10 MHz) Asymmetry (@ 50% duty) 1% of period + 5 ns Jitter (RMS) 1 ns + 100 ppm of period Ramp, triangle Frequency range 1 mHz to 100 kHz Linearity < 0.1% of peak output Variable symmetry 0.0% to 100.0% Pulse Frequency range 1 mHz to 5 MHz Pulse width (period ≤ 10 s) 40 ns minimum 10 ns resolution Variable edge time 20 ns to 100 ns Overshoot < 2% Jitter (RMS) 300 ps + 0.1 ppm of period Noise Bandwidth 7 MHz typical Uncompromising performance at an affordable price The Keysight Technologies, Inc. 33210A function/arbitrary waveform generator is the latest addition to the 332XX family. Waveforms are generated using direct digital synthesis (DDS) technology which creates stable, accurate low distortion sine waves as well as square waves with fast rise and fall times up to 10 MHz and linear ramp waves up to 100 kHz. For user defined waveforms, Option 002 provides 14-bit, 50 MSa/s 8K point arbitrary wave - form generation. Pulse generation The 33210A can generate variable-edge- time pulses up to 5 MHz. With variable period, pulse width, and amplitude the 33210A is ideally suited to a wide variety of applications requiring a flexible pulse signal. Custom waveform generation (Option 002) The optional 8K point arbitrary waveform generator (Option 002) can be used in the 33210A to generate complex custom waveforms. With 14-bit resolution, and a sampling rate of 50 MSa/s, the 33210A gives you the flexibility to create the waveforms you need. It also lets you store up to four waveforms in nonvolatile memory. The Keysight IntuiLink arbitrary wave- form software allows you to easily create, edit, and download complex waveforms using the waveform editor. Or you can capture a waveform using IntuiLink for Oscilloscopes and send it to the 33210A for output. To find out more about IntuiLink, visit www.keysight.com/find/intuilink Easy-to-use functionality Front-panel operation of the 33210A is straight-forward and user friendly. You can access all major functions with a single key or two. The knob or numeric keypad can be used to adjust frequency, ampli - tude, offset, and other parameters. You can even enter voltage values directly in Vpp, Vrms, dBm, or as high and low levels. Timing parameters can be entered in Hertz (Hz) or seconds. Internal AM, FM, and PWM modulation make it easy to modulate waveforms with - out the need for a separate modulation source. Linear and logarithmic sweeps are also built in, with sweep rates selectable from 1 ms to 500 s. Burst mode operation allows for a user-selected number of cycles per trigger. GPIB, LAN, and USB interfaces are all standard, plus you get full program - mability using SCPI commands. External frequency reference (Option 001) The 33210A external frequency refer- ence lets you synchronize to an external

10 MHz clock, to another 33210A, or to

a Keysight 33220A or Keysight 33250A. Phase adjustments can be made from the front panel or via a computer interface, allowing precise phase calibration and adjustment.

Measurement Characteristics (continued) 8K-point arbitrary waveform generator (Option 002) Frequency range 1 mHz to 3 MHz Waveform length 2 to 8 k points Amplitude resolution 14 bits (including sign) Sample rate 50 MSa/s Min. rise/fall time 70 ns typical Linearity < 0.1% of peak output Settling time < 500 ns to 0.5% of final value Jitter (RMS) 6 ns + 30 ppm Non-volatile memory 4 waveforms Common characteristics Frequency Accuracy 5 ± (10 ppm + 3 pHz) in 90 days ± (20 ppm + 3 pHz) in 1 year Resolution 1 µHz (internal) 1 mHz (user) Amplitude Range 10 mVpp to 10 Vpp into 50 Ω 20 mVpp to 20 Vpp into open circuit Accuracy 1, 2 (at 1 kHz) ± 2% of setting ± 1 mVpp Units Vpp, Vrms, dBm Resolution 3 digits DC offset Range (peak AC + DC) ± 5 V into 50 Ω ± 10 V into open circuit Accuracy 1, 2 ± 2% of offset setting ± 0.5% of amplitude ± 2 mV Resolution 3 digits Main output Impedance 50 Ω typical Isolation 42 Vpk maximum to earth Protection Short-circuit protected, overload automatically disables main output External frequency reference (Option 001) Rear panel input Lock range 10 MHz ± 500 Hz Level 100 mVpp to 5 Vpp Impedance 1 kΩ, typical Lock time < 2 seconds Rear panel output Frequency 10 MHz Level 632 mVpp (0 dBm), typical Impedance 50 Ω, typical AC coupled Phase offset Range +360° to –360° Resolution 0.001° Accuracy 20 ns Footnotes [1] Add 1/10th of output amplitude and offset spec per °C for operation outside the range of 18 to 28 °C [2] Autorange enabled [3] DC offset set to 0 V [4] Spurious output at low amplitude is –75 dBm typical [5] Add 1 ppm/°C average for operation outside the range of 18 to 28 °C [6] Sine and square waveforms above 3 MHz are allowed only with an “infinite” burst count [7] Only available if Option 002 is installed Modulation AM Carrier waveforms Sine, Square Source Internal/External Internal modulation Sine, Square, Ramp, Triangle, Noise, Arb 7 (2 mHz to 20 kHz) Depth 0.0% to 120.0% FM Carrier waveforms Sine, Square Source Internal/External Internal modulation Sine, Square, Ramp, Triangle, Noise, Arb 7 (2 mHz to 20 kHz) Deviation DC to 5 MHz PWM Carrier waveforms Pulse Source Internal/External Internal modulation Sine, Square, Ramp, Triangle, Noise, Arb 7 (2 mHz to 20 kHz) Deviation 0% to 100% of pulse width External modulation input (for AM, FM, PWM) Voltage range ± 5 V full scale Input impedance 5 kΩ typical Bandwidth DC to 20 kHz Sweep Waveforms Sine, Square, Ramp Type Linear or Logarithmic Direction Up or Down Sweep time 1 ms to 500 s Trigger source Single, External or Internal Marker Falling edge of sync signal (programmable frequency) Burst 6 Waveforms Sine, Square, Ramp Type Counted (1 to 50,000 cycles), Infinite, Gated Start/stop phase +360° to –360° Internal period 1 µs to 500 s Gate source External trigger Trigger source Single, External or Internal Trigger characteristics Trigger input Input level TTL compatible Slope Rising or Falling, selectable Pulse width > 100 ns Input impedance > 10 kΩ, DC coupled Latency < 500 ns Jitter (rms) 6 ns (3.5 ns for pulse) Trigger output Level TTL compatible into ≥ 1 kΩ Pulse width > 400 ns Output impedance 50 Ω typical Maximum rate 1 MHz Fanout ≤ 4 Keysight 33210As (or equivalent)

Ordering Information

10 MHz function/arbitrary

Operating manual, service manual, quick reference guide, IntuiLink waveform editor software, test data, USB cable, and power cord (see language option). Options Opt. 001 External timebase reference Opt. 002 8K-point arbitrary waveform generator Opt. A6J ANSI Z540 calibration Opt. AB0 Taiwan: Chinese manual Opt. AB1 Korea: Korean manual Opt. AB2 China: Chinese manual Opt. ABA English: English manual Opt. ABD Germany: German manual Opt. ABF France: French manual Opt. ABJ Japan: Japanese manual Opt. PLG Continental European power cord Other Accessories 34131A Carrying case 34161A Accessory pouch 34190A Rackmount kit 34191A Dual flange kit, 2U 34194A Dual lock link kit Measurement Characteristics (continued) General Power supply Cat II 100 to 240 V @ 100 to 120 V @ 400 Hz (± 10%) Power consumption 50 VA max Operating environment IEC 61010 Pollution Degree 2 Indoor Location Operating temperature 0 to 55 °C Operating humidity 5% to 80% RH, non-condensing Operating altitude Up to 3000 meters Storage temperature –30 to 70 °C State storage memory Power off state automatically saved, Four user-configurable stored states Interface LAN LXI-C Ethernet 10/100 USB 2.0, GPIB Language SCPI – 1993, IEEE-488.2 Dimensions (W x H x D) Bench top 261.1 mm x 103.8 mm x 303.2 mm Rack mount 212.88 mm x 88.3 mm x 272.3 mm Weight 3.4 kg (7.5 lbs) Safety designed to UL-1244, CSA 1010 EN61010 EMC tested to MIL-461C, EN55011, EN50082-1 Vibration and shock MIL-T-28800, Type III, Class 5 Acoustic noise 30 dBa Warm-up time 1 hour Programming times (typical) Configuration times USB LAN GPIB Function change 120 ms 120 ms 120 ms Frequency change 2 ms 3 ms 2 ms Amplitude change 30 ms 30 ms 30 ms Select user arb 130 ms 130 ms 130 ms Arb download times (Option 002) Binary transfer USB LAN GPIB 2 k points 5 ms 9 ms 10 ms 4 k points 8 ms 15 ms 20 ms 8 k points 14 ms 27 ms 40 ms

www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/33210a For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-06-16-14) 05 | Keysight | 33210A 10 MHz Function/Arbitrary Waveform Generator - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2012 - 2014 Published in USA, August 2, 2014 5989-8926EN www.keysight.com