Technical content
CLAMP ON LEAK HiTESTER 3293 3293 Leak and load current ✔ Stylish pocket-size design ✔ Backlit display with automatic reverse feature ✔ Filter 3291 Load current The World's First Flip Clamp! 10uA Resolution Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the Double the functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality functionality For leak and load current: 3293 (0.06mA to 1000A) For load current: 3291 (0.06A to 1000A)
■ Easy to see, even when held down low Flip-type clamp on design delivers the ease-of-use demanded by fi eld technicians Flip-down display keeps readings in easy view whether the target wire is up high or down low Equipped with an innovative display that flips down for easy visibility, the 3291 and 3293 are designed for efficient measurement of indoor wiring in a variety of environments, from factories, buildings, and offi ces to residences. ■ Easy measurement of wires on ceilings ■ Easy to see, even when held up high Unmatched ease of use ❏ Clamp meter turns on automatically when the clamp is opened so you can begin taking measurement immediately. Flip angle: 180° ❏ Slim core opens wide for easier clamping. Open Jaws to Power On ❏ Backlight lets you read measurements in dim locations Up to 24 mm in diameter 3293 11mm Up to 30 mm in diameter 3291 8mm
- Push and hold for 2 seconds to activate
- Backlight goes out automatically after 15 seconds Sometimes it’s easier to clamp the target wire at an angle. New clamp design is easier to attach Slim clamp with a wide aperture attaches easily, requiring only 12.5 mm of space between wires. Display can also be reversed manually with the press of a button. ❏ Measurement reading reverses automatically when the display is fl ipped open to ensure readability. Easy to read means easy to use ❏ Display rotates freely through 18 0° to keep measurements in view. Automatically turns off 1 minute after input falls to 0A following measurement. (Can be manually disabled.)
❏ Easy-to-use auto range feature ❏ Get the maximum value of fl uctuating current readings Filter out noise The 3291 and 3293 incorporate a switchable high-frequency noise fi lter. When activated, this fi lter rejects frequencies of
180 Hz and above to enable measurement approximating the
fi lter characteristics of an earth leakage circuit breaker (ELCB). Filter on Extensive current measurement functions Use with 3-phase 4-wire 440V lines 3291: CAT III 600 V (CAT IV 300 V) 3293: CAT III 300 V Measure leak and load current with the 3293 The 3293 features 6 ranges from 30 mA to 1000A, offering ±5% rdg ±5 dgt measurement accuracy of 1mA leak currents. Leak current easurement Load current measurement3293 True RMS lets you measure even distorted currents accurately True RMS ensures accurate measurement, even of distorted load and leak currents ❏ Why does the same current yield different readings? Inverters, offi ce equipment, AC adapters - most load current waveforms are distorted. Current meters that display average rectifi ed RMS values does not allow you to obtain accurate RMS measurements. Averaging-type clamp on current meter True RMS clamp on current meter Loop a wrist strap through the small opening to help keep the instrument from being dropped Measure fl uctuating currents with the peak hold feature The 3291 and 3293’s peak hold feature (with bar graph hold) lets you capture peak values for currents that fl uctuate due to load variability. Current (A) Time Peak value display Peak value is held on the bar graph. 3293 Actual Size 1000A600.0A60.00ARange Leak current easurement Load current measurement3291 Push and hold for 2 seconds to activate fi lter ❏ Easy measurement of the peak value of a fl uctuating current. *Holds the peak value for data updated approximately 2 times/second.
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com DISTRIBUTED BY All information correct as of Jul. 12, 2007. All specifi cations are subject to change without notice. 3291sE1-77M-20P Printed in Japan HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1904 Shanghai Times Square Offi ce, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: info-sh@hioki.cn Beijing Offi ce : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: info-bj@hioki.cn Guangzhou Offi ce : Room 303, Profi t Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: info-gz@hioki.cn 3291 Load 3293 Leak and load Measurable conductor size ø30mm (1.18")max. ø24mm (0.94")max. Rectification True RMS Max. rated voltage to earth AC600Vrms AC300Vrms Measurement Range
- Auto Range switching
- Zero-suppress at 5 counts 60A/600A/1000A 30mA/300mA/ 6A/60A/600A/1000A Accuracy filter ON: fc=180Hz ±1.5%rdg. ±5dgt. (50Hz to 60Hz), ±5%rdg. ±5dgt. (1mA to 2.70mA) filter OFF: ±2.0%rdg. ±5dgt. (45 to 66Hz), ±3.0%rdg. ±5dgt. (66 to 400Hz) (Add±1%rdg. for when using 60A on the 3293) Guaranteeed Accuracy Period 1 Year (or opening and closing of the sensor 10,000 times) Accuracy Guaranteed Measurements Minimum 5.40A Minimum 1.00mA (Add±1%rdg. for readings of 0.270 to 0.540A ) Crest factor 2.8 max (1.6 max when current exceeds 600A) Response Time Max. 1.5s (Refers to time required to achieve 90% of accuracy specifications) Display Refresh Rate Approx. 2 times/second (Bar graph: Approx. 4 times/second) Temperature Coeffi cient Add (0.05 x accuracy specifications)/°C (at 0°C to 40°C) Effect of Conductor Position within ±5.0% within ±0.1% (at or below 6A range) within ±5.0% (at or below 60A range) Effect of External Magnetic Field not defined Max 7.5mA (within a 400A/m magnetic field, at or below 6A range) Other Functions Display hold, maximum value hold (hold bar graph position), reversible LCD display, backlight, auto power off, auto power on when jaws are open, battery level indication Usage Environment 0°C to 40°C/32°F to 104°F, 80%rh max. (no condensation) Storage Environment -10°C to 50°C/14°F to 122°F, 80%rh max. (no condensation) Standards EN61010-2-032 Type A current sensor, CA T III 600V , CA T IV 300V , EN61326 EN61010-2-032 Type A current sensor, CA T III 300V , EN61326 Rated Voltage and maximum rated power DC3V , 25mV A Power Supply and max. continuous use Button type lithium battery (CR2032) x 1, Approx. 10 hours (continuous, no load) Dimensions and mass 50W×136H×26Dmm, 90g 50W×130H×26Dmm, 120g Bundled Accessories: Carrying Case 9757 x 1, Wrist strap x 1, Button type lithium battery (CR2032 - test use only) x 1, Instruction Manual x 1, Basic Operation Sticker x 1 Pocket Size Clamp On Design Fits perfectly into a shirt pocket. Convenient portable case Included soft case protects the i n s t r u m e n t a n d a t t a c h e s conveniently to your belt. ❏ Soft case protects the instrument inside toolboxes. 6.00mA 05101520 6.00mA 05101520 6.00mA 05101520 6.00 0510 Inside toolboxes Attaches to beltCarrying Case Model 9757 (included) ■ 3291, 3293 Specifi cations (accuracy at 23˚C±5˚C (73˚F±9˚F), 80% RH or less) ❏ Compact design for superior portability Measurement Range
- Auto Range switching Accuracy filter ON: fc=180Hz Guaranteeed Accuracy Period Accuracy Guaranteed Measurements Crest factor Response Time Display Refresh Rate Temperature Coeffi cient Effect of Conductor Position Effect of External Magnetic Field Other Functions Usage Environment Storage Environment Standards Rated Voltage and maximum rated power Power Supply and max. continuous use Dimensions and mass 3291 Actual Size