3284 ASM-SENSOR | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
(3285 /3285-20) 3284 [200A rms, ø 33mm(1.30 ") max.] 3285/-20 [2000A rms, ø 55mm(2.17" ) max.] http://www.hioki.co.jp/ http://www.hioki.co.jp/ CAT I II 600 V Field measuring instruments CLAMP ON AC/DC HiTESTER
2000 A2000 A analysisanalysis
3284E6-5XM-05K Printed in JapanAll information correct as of Oct. 11, 2005. All specifications are subject to change without notice. HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-co m@hioki.co.jp HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki @hiokiusa.com DISTRIBUTED BY Shanghai Representative Office :
1704 Shanghai Times Square Office
93 Huaihai Zhong Road
Shanghai, 200021, P .R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: info@hioki.cn
3284 CLAMP ON AC/DC HiTESTER
3285 CLAMP ON AC/DC HiTESTER
3285-20 CLAMP ON AC/DC HiTESTER (All include 9207-10 TEST LEADS, 9399 CARRYING CASE(3284), 9345 CARRYING CASE(3285/3285-20), HAND STRAP) *No CE marking Options 9445-02 AC ADAPTER (UL) 9445-03 AC ADAPTER (EU) An AC Adapter can only be used with Models 3284 and 3285.
9094 OUTPUT CORD(Jack to banana plug)*
measurement of the RMS value of full- or half-wave rectified waveforms used in electrical machinery. 0mA full-wave rectified waveforms RMS value of full-wave rectified waveforms Analysis applications Supporting a wealth of functions Using the external output functions of the 3284 or 3285 in combination with a HIOKI MEMORY HiCORDER enables recording of current and frequency fluctuations and recording and harmonic analysis of instantaneous waveforms. The monitor output (MON) spans a wide frequency range from DC to 20 kHz (15 kHz in the case of 3285), which allows the units to be used for electric current analysis in various fields ranging from batteries to inverters. Example of analysis using the MEMORY HiCORDER Harmonic analysis current fluctuations current waveform (inverter output ) 9199 BNC TO BANANA ADAPTER 9094 OUTPUT CORD 8807-51 MEMORY HiCORDER Waveform harmonicWaveform and harmonic analysis Model 3284 and 3285 only The peak hold function displays the crest value of the inrush current occurring when electrical equipment is started. 0 Crest value peak Inrush current Inrush current crest value ■ 3284 / 3285 Specifications 1.0%rdg.±13dgt when measuring 700 V to 1000V with Model 3285-20. *8 Model 3285-20 only. [ ] in the Specification :3285,3285-20 Accuracy at 23 ˚C ± 5 ˚C (73 ˚F ± 9 ˚F), 80% rh or less. Measurement accuracy applies to input of at least 5% of the current range, and at least 10% of the voltage/frequency range. Open terminal V oltage 3.1V DC or less±1.5%rdg.±5dgt. Threshold level 30Ω ±5Ω or less 1000/10.00k 1000 Resistance(Ω)*8 Function Mode Display Switch*1 Range Accuracy at DC or 45 to 66 Hz Notes Current (A) DC Average / PEAK 20.00 / 200.0 [200.0 / 2000] Resolution is 0.1 [1] A during PEAK ±1.3%rdg.±3dgt. Max. allowable current Voltage (V) DC Average / PEAK 30.00 / 300.0 / 600 Resolution is decreased by 1 digit except in the 600 V range during PEAK ±1.0%rdg.±3dgt. Max. allowable voltage AC+DC RMS / PEAK ±1.0%rdg.±7dgt.*5 10 to 45Hz or 66 to 2 [ 1 ] kHz ±2.0%rdg.±5dgt.*3 *4 ±2.0%rdg.±7dgt.*3*4 ±1.5%rdg.±5dgt. ±1.5%rdg.±7dgt.*5 PEAK accuracy at DC or 45 to 66 Hz ±1.3%rdg.±7dgt.*6 ±1.3%rdg.±7dgt.*6 ±1.3%rdg.±7dgt.*6 ±1.0%rdg.±7dgt. ±1.0%rdg.±7dgt.*7 ±1.0%rdg.±7dgt.*7 Continuity Check*8 Effect of conductor position : within ±0.5 [0.7] % in any direction from the center of sensor Effect of external magnetic field : 400A/m corresponds to 0.5 [2] A max. Crest factor : 2.5 or less, 1.7 or less in the 600 V range, 3284 is 1.5 or less in the 200A range [ 1.42 or less in the 2000A range] Safety standard : EN61010-1 CAT I I I 600V , EN61010-2-032, EN60529 IP40 EMC : EN61326, EN61000-3-2, EN61000-3-3 Ambient temperature of use : 0 to 40˚C (32˚F to 104˚F), 80%rh or less (no condensation) Storage temperature range : -10 to 50˚C (14˚F to 122˚F) or less (no condensation) Power supply : 9445 AC ADAPTER(Except Model 3285-20.) or 6F22 manganese battery×1 (continuous operation : Model 3284/3285-25 hours, Model 3285-20-20 hours) Dimensions and mass : Approx. 62W×230 [260]H×39D mm, 460 [540]g Measurable conductor diameter : ø33 (1.30") mm, [ø55 (2.17") mm] max. Max. usable circuit voltage : 600Vrms (insulated conductor) Functions : recording (MAX. MIN. A VE) ,data hold, auto power-off, auto zero Display update rate : digital indication F AST approx. 4 times/second, NORMAL approx. 2 times/second, SLOW 1 time/ 3 seconds; bar graph indication approx. 4 times/second Display response time : 1 sec or less Range switching : Auto/Manual (Except resistance.) Frequency characteristic : 40 Hz to 2 [1] kHz accuracy External output : A/Hz only: recording output DC1V/f.s. ±1.3% rdg.±10mV , Response: 250ms or less (at 0➞90%)/ MON A only : Waveform output 1Vrms/f.s. ±1.3% rdg.±5mV , Frequency band: DC to 20 [15] kHz ±3dB (Except model 3285-20)