3273-50 ASM-SENSOR | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Wide-band Models from DC to 100 MHz 3273-50 - 3276 CLAMP ON PROBES HIOKI company overview, new products, environmental considerations and other information are available on our website. http://www.hioki.co.jp/
Input: 1 kHz square wave 200 mAp-p (Oscilloscope bandwidth 400 MHz) Input: 1 MHz square wave 200 mAp-p (Oscilloscope bandwidth 400 MHz) I Transient response Input: 100 mAp-p (Oscilloscope bandwidth 400 MHz) I Low-current measurement Input: 1 kHz sine wave 10 mAp-p (Oscilloscope bandwidth 20 MHz) 1k 10k 100k 1M 10M 100M100 10 I 3. Input impedance (Characteristics Example) I 1. Frequency response (Characteristics Example) I 2. Continuous maximum input rating (Frequency derating) Input impedance [Ω] Frequency [Hz]Frequency [Hz] Amplitude [dB, 0dB=1V] Frequency [Hz] Maximum input current [Arms] 1k 10k 100k 1M 10M 100M100 10 I 3. Input impedance (Characteristics Example) I 1. Frequency response (Characteristics Example) I 2. Continuous maximum input rating (Frequency derating) Input impedance [Ω] Frequency [Hz]Frequency [Hz] Amplitude [dB, 0dB=1V] Frequency [Hz] Maximum input current [Arms] I Square wave response Input: 1 kHz square wave 200 mAp-p (Oscilloscope bandwidth 400 MHz) Input: 1 MHz square wave 200 mAp-p (Oscilloscope bandwidth 400 MHz) I Transient response Input: 100 mAp-p (Oscilloscope bandwidth 400 MHz) I Low-current measurement Input: 1 kHz sine wave 10 mAp-p (Oscilloscope bandwidth 20 MHz) Important Characteristics Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due to breaks in the electrical path. The 3273 -50 - 3276 CLAMP ON PROBEs only need to be connected directly into the BNC input on waveform observation equipment such as an oscilloscope or a recorder. Then simply clamp onto the conductor to be measured to easily observe current waveforms under a wide bandwidth and high sensitivity conditions. 3273-50 3276 3276 3273-50DC to 50 MHz DC to 100 MHz 3273-50 to 3276 CLAMP ON PROBE
G High S/N ratio: ideal for measuring milliampere waveforms (Model 3273-50) G Capable of waveform monitoring from wide band and minute currents to large currents (Model 3274) G Permits waveform observation of large current of up to
500 Arms (Model 3275)
G Wide-band waveform observations, from DC to 100 MHz (Model 3276) G Direct connection to BNC input of oscilloscope G Highly accurate current detection G Newly developed indium-antimony (InSb) thin-film Hall element G Simple overload protector prevents damage due to overheating G Easy measurement G The 3273-50 includes a soft case, the 3274 / 3275 /3276 includes a hard carrying case I Square wave response Input: 100 Hz square wave 300 Ap-p (Oscilloscope bandwidth 20 MHz) Input: 10 kHz square wave 400 mAp-p (Oscilloscope bandwidth 20 MHz) I Transient response Input: 1 Ap-p (Oscilloscope bandwidth 20 MHz) I Low-current measurement Input: 1 kHz sine wave 50 mAp-p (Oscilloscope bandwidth 20 MHz) I 3. Input impedance (Characteristics Example) I 1. Frequency response (Characteristics Example) I 2. Continuous maximum input rating (Frequency Derating) Input impedance [Ω] Frequency [Hz]Frequency [Hz] Amplitude [dB, 0dB=1V] Frequency [Hz] Maximum input current [Arms]
Features
I 3. Input impedance (Characteristics Example) I 1. Frequency response (Characteristics Example) I 2. Continuous maximum input rating (Frequency Derating) Input impedance [Ω] Frequency [Hz]Frequency [Hz] Amplitude [dB, 0dB=1V] Frequency [Hz] Maximum input current [Arms] I Square wave response Input: 100 Hz square wave 20 Ap-p (Oscilloscope bandwidth 100 MHz) Input: 100 kHz square wave 400 mAp-p (Oscilloscope bandwidth 100 MHz) I Transient response Input: 1 Ap-p (Oscilloscope bandwidth 100 MHz) I Low-current measurement Input: 1 kHz sine wave 50 mAp-p (Oscilloscope bandwidth 100 MHz) 100m 10m 3274 3274 3275 DC to 10 MHz DC to 2 MHz 3273-50 to 3276 CLAMP ON PROBE I Waveform Example Lighting Inverter 200 mA/div 20 µs/div Press Machine Load Current
50 A/div
100 A/div
Frequency bandwidth DC to 50 MHz (-3 dB) * See Fig. 1 on page 1. Rise time 7 ns or less Continuous maximum input range
30 Arms
- Frequency derating see Fig. 2 on page 1. Maximum peak current value Non-continuous 50 Apeak Output voltage rate 0.1 V/A Amplitude accuracy ±1.0% rdg. ±1 mV (0 to 30 Arms / DC, 45 to 66 Hz) ±2.0% rdg. (30 Arms to 50 Apeak / DC, 45 to 66 Hz) Input impedance * See Fig. 3 on page 1. Sensitivity temperature characteristics Within ±2% (At 50 Hz/30 Arms input, 0 to 40˚C [32 to 104˚F]) Maximum rated power 5.6 VA (Input within the maximum input range.) Operating temperature and humidity 0 to 40˚C [32 to 104˚F] , 80% rh or less (no condensation) Effect of external magnetic fields Max. 20 mA (equivalent) (DC and 60 Hz, Magnetic field of 400 A/m) Max. rated voltage to earth 300 V, CAT-I (insulated conductor) Measurement conductor Diameter max. 5 mm [0.20"] Dimensions and mass Sensor: approx. 175(W)✕18(H)✕40(D) mm; 230 g Termination unit: approx. 27(W)✕55(H)✕18(D) mm Cable length Sensor cable: approx. 1.5 m [59.06"] (BNC connector) Power cable: approx. 1 m [39.37"] Supplied accessories Soft case✕1 Applicable standards EN 61010-2-031: 1994, EN 61010-2-032: 1995 Measurement category I (anticipated transient overvoltage 1500 V), Pollution Degree 2 EN 61326:1997+A1:1998+A2:2001 EN 61000-3-2: 2000 EN 61000-3-3: 1995+A1:2001 Safety standards EMC Power supply voltage ±12 V ±0.5 V 3276 DC to 100 MHz (-3 dB) * See Fig. 1 on page 1. 3.5 ns or less
- Frequency derating see Fig. 2 on page 1. Non-continuous 50 Apeak
0.1 V/A
±1.0% rdg. ±1 mV (0 to 30 Arms / DC, 45 to 66 Hz) ±2.0% rdg. (30 Arms to 50 Apeak / DC, 45 to 66 Hz) * See Fig. 3 on page 1. Within ±2% (from 0 to 40 ˚C [32 to 104 ˚F] ) 5.3 VA (Input within the maximum input range.) 0 to 40˚C [32 to 104˚F] , 80% rh or less (no condensation) Max. 5 mA (equivalent) (DC and 60 Hz, Magnetic field of 400 A/m)
300 V, CAT-I (insulated conductor)
Diameter max. 5 mm [0.20"] Sensor: approx. 175(W)✕18(H)✕40(D) mm; 240 g Termination unit: approx. 27(W)✕55(H)✕18(D) mm Sensor cable: approx. 1.5 m [59.06"] (BNC connector) Power cable: approx. 1 m [39.38"] Hard case✕1 EN 61010-2-032:2002 Measurement category I (anticipated transient overvoltage 1500 V), Pollution Degree 2 EN 61326:1997+A1:1998+A2:2001 EN 61000-3-2: 2000 EN 61000-3-3: 1995+A1:2001 ±12 V ±0.5 V Power supply plug Connects to the FET probe power supply outlet of an oscilloscope or to the optional 3269 / 3272 power supply unit. (Provided that connector type, pin assignment, voltage, and capacity rating match, the 3273-50 to 3276 can be powered also from another source. For operation safety, be sure to refer to the specifications to ensure an exact match.) Sensor cable (approx. 1.5 m [59.06"]) BNC output connector Can be connected directly to the BNC input of an oscilloscope or level recorder or similar device. Output voltage rate: 0.1 V/A (3273-50 / 3276)
0.01 V/A (3274 / 3275)
(Use only equipment with an input impedance of 1 MΩ or more.) G G G Power cable (approx. 1 m [39.37"]) Sensor cable (approx. 2 m [78.74"]) Maximum measurement conductor: dia. 5 mm [0.20"] Maximum measurement conductor: dia. 20 mm [0.79"] * Connector type: LEMO inc./ FFA.0S.304.CLAC42Z 1 2 1 : Not connected 2 : GND 3 : V- (-12V) 4 : V+ (+12V) Power supply plug pin assignment (Plug as seen from the front) 3273-50 to 3276 CLAMP ON PROBE -10 to 50˚C [14 to 122˚F] , 80% rh or less (no condensation) Storage temperature and humidity -10 to 50˚C [14 to 122˚F] , 80% rh or less (no condensation) 2.5 mArms or less (measured with 20 MHz bandwidth equipment)Noise 2.5 mArms or less (measured with 20 MHz bandwidth equipment) Sensor head Composed of molded parts, ferrite and Hall elements. The thin-film of the Hall element especially improves detection sensitivity to realize wider bands and high sensitivity monitoring. 3273-50 3276 I 3273-50 / 3276 Specifications (accuracy is guaranteed at 23±3˚C [73±5˚F] after the power has been on for 30 minutes)
I 3274/3275 Specifications (accuracy is guaranteed at 23±3˚C [73±5˚F] after the power has been on for 30 minutes) 3274 3275 Frequency bandwidth DC to 10 MHz (-3 dB) * See Fig. 1 on page 2. DC to 2 MHz (-3 dB) * See Fig. 1 on page 2. Rise time 35 ns or less 175 ns or less Continuous maximum input range
150 Arms
- Frequency derating see Fig. 2 on page 2.
500 Arms
- Frequency derating see Fig. 2 on page 2. Maximum peak current value Non-continuous 300 Apeak
500 A peak at pulse width of ≤ 30 ms Non-continuous 700 Apeak
Output voltage rate 0.01 V/A 0.01 V/A Amplitude accuracy ±1.0% rdg. ±1 mV (0 to 150 Arms / DC, 45 to 66 Hz) ±2.0% rdg. (150 Arms to 300 Apeak / DC, 45 to 66 Hz) ±1.0% rdg. ±5 mV (0 to 500 Arms / DC, 45 to 66 Hz) ±2.0% rdg. (500 Arms to 700 Apeak / DC, 45 to 66 Hz) Input impedance * See Fig. 3 on page 2. * See Fig. 3 on page 2. Sensitivity temperature characteristics Within ±2% (At 55 Hz/150 A input, 0 to 40˚C [32 to 104˚F]) Within ±2% (At 50 Hz/500 A input, 0 to 40˚C [32 to 104˚F]) Maximum rated power 5.5 VA (Input within the maximum input range.) 7.2 VA (Input within the maximum input range.) Operating temperature and humidity Diameter max. 20 mm [0.79"]
600 V CAT-I I, 300 V CAT-I I I (insulated conductor)
Max. 150 mA (equivalent) (DC and 60 Hz, Magnetic field of 400 A/m) Max. 800 mA (equivalent) (DC and 60 Hz, Magnetic field of 400 A/m) Max. rated voltage to earth 600 V CAT-I I, 300 V CAT-I I I (insulated conductor) Sensor cable: approx. 2 m [78.74"] (BNC connector) Power cable: approx. 1 m [39.37"] Measurement conductor Diameter max. 20 mm [0.79"] EN 61010-2-031: 1994, EN 61010-2-032: 1995 Overvoltage category I I, I I I (anticipated transient overvoltage 4000 V), Pollution Degree 2 Dimensions and mass Sensor: approx. 176(W)✕69(H)✕27(D) mm; 500 g Termination unit: approx. 27(W)✕55(H)✕18(D) mm Sensor: approx. 176(W)✕69(H)✕27(D) mm; 520 g Termination unit: approx. 27(W)✕55(H)✕18(D) mm Cable length Sensor cable: approx. 2 m [78.74"] (BNC connector) Power cable: approx. 1 m [39.37"] EN 61010-2-031: 1994, EN 61010-2-032: 1995 Overvoltage category I I, I I I (anticipated transient overvoltage 4000 V), Pollution Degree 2 Supplied accessories Hard case✕1 Hard case ✕1 Applicable standards 0 to 40˚C [32 to 104˚F] , 80% rh or less (no condensation) 0 to 40˚C [32 to 104˚F] , 80% rh or less (no condensation) EN 61326-1: 1997+A1:1998 EN 61000-3-2: 1995+A1:1998+A2: 1998 EN 61000-3-3: 1995 EN 61326-1: 1997+A1:1998 EN 61000-3-2: 1995+A1:1998+A2: 1998 EN 61000-3-3: 1995 Safety standards EMC Power supply voltage ±12 V ±1 V ±12 V ±0.5 V 3273-50 to 3276 CLAMP ON PROBE Noise 25 mArms or less (measured with 20 MHz bandwidth equipment) 25 mArms or less (measured with 20 MHz bandwidth equipment) Storage temperature and humidity -10 to 50˚C [14 to 122˚F] , 80% rh or less (no condensation) -10 to 50˚C [14 to 122˚F] , 80% rh or less (no condensation) I 3269/3272 POWER SUPPLY Dedicated power supplies for the Clamp Sensor series-ideal when power is not available from the oscilloscope, or when using the probes for common measurement applications. *The total current output of the 3272 is 600mA (for two channels). Depending on the current of the measurement object, simultaneous use of both channels may not be available. The 3269 is capable of powering 4 channels of high current sensors simultaneously. 3272 3269 I 3269 / 3272 Specifications I Current consumption of the 3273-50 to 3276 (sum of real values). AC(f=50Hz) DC 600 500 400 300 200 100 0 10 20 30 current to be measured (A) current consumption (mA) 0 50 100 150 600 500 400 300 200 100 AC (f=50Hz) DC current to be measured (A) current consumption (mA) 600 500 400 300 200 100 0 200 300 700100 400 500 600 AC (f=50Hz) DC current to be measured (A) current consumption (mA) 0 10 20 50 current to be measured (A) 600 500 400 300 200 100 current consumption (mA) AC (f=50Hz) DC 30 40 [ 3273-50 ] [ 3274 ] [ 3275 ] [ 3276 ] 3272 3269 Number of power 2* 4 Output voltage ±12 V ±0.5 V Rated output current 600 mA (sum total of all channels and all output voltage) ±2.5 A Power requirements (50/60 Hz) 100V AC±10% (Specify 120, 220 or 240V power supply when ordering.) AC100 to 240 V±10% Maximum rated power 20 VA 170 VA Dimensions Approx. 73W ✕110H ✕186D mm Approx. 80W ✕119H ✕200D mm Mass Approx. 1.1 kg Approx. 1.1 kg Accessories Power cord, Spare fuse Compatible sensors 3273-50/3274/3275/3276 CLAMP ON PROBE (sum total of all channels) 3274 3275
Rated current 20 A (AC+DC) 150 A(AC+DC) Output voltage 2 V/20 A (AC+DC) 1.5 V/150 A(AC+DC) Output resistance Input impedance Continuous maximum input range Maximum peak current value (DC and 45 to 66Hz) Phase accuracy Frequency bandwidth (-3dB) DC to 10 MHz DC to 1 MHz Sensitivity temperature characteristics (0 to 40˚C) Power consumption Power supply voltage Operating temperature and humidity Storage temperature and humidity Effect of external magnetic fields (in 400 A/m AC ) Influence of conductor position Withstand voltage Insulation resistance Max. rated voltage to earth Measurement conductor Cable length Dimensions and mass Supplied accessories I 9274/9276 CLAMP ON AC/DC SENSOR Specifications (Accuracy is guaranteed at 23±3 ˚C [73±5˚F] after the power has been on for 30 minutes) I 3270 Specifications (Accuracy is guaranteed at 23±3 ˚C [73±5˚F] after the power has been on for 30 minutes) 9274/9276 CLAMP ON AC/DC SENSOR DC to MHz Range 9274 9276 3270 CURRENT MONITOR A wide range of current waveforms from DC to MHz can be observed at high precision. The 3270 is a DC/AC amplifier that can be connected to the 9274/9276 to enable current waveforms to be recorded and easily observed by connecting a recorder or oscilloscope. The high degree of electron mobility in InSb makes it ideal for our highly sensitive thin-film Hall element. We have adapted these qualities for measuring a wide range of current, as well as for very low levels. The probe cannot be used alone: the 3270 is required. 50 Ω 0.1 mΩ or less at 55Hz 0.02 m Ω or less at 55Hz
150 A20 A
400 A non-continuous (peak value)50 A non-continuous (peak value)
±0.2˚ (45 to 66Hz) 2 VA Max. (at rated input)1.5 VA Max. (at rated input) ±12 V ±1 V 0 to 40˚C [32 to 104˚F] , 80% RH or less (no condensation) -10 to 50˚C [14 to 122˚F] , 80% RH or less (no condensation)
1 A equivalent maximum20 mA equivalent maximum
within ±0.2% within ±1%
2200 V AC for 1 minute (electrical circuits to case)
At least 100 MΩ at 500 V DC (electrical circuits to case)
600 V peak (insulated wire)
Diameter max. 5 mm [0.20"] Diameter max. 20 mm [0.79"] Approx. 1.5 m [59.06"] Approx. 145(W)✕60(H)✕33(D) mm, 300 g Approx. 175(W)✕40(H)✕18(D) mm, 230 g Carrying caseSoft case - 20 - 30 - 40 - 10 1 100 10k 1M rate : 2V/20A Phase Amplitude Amplitude ( dB,0dB=1V ) Phase ( deg. ) - 180 - 135 - 90 - 45 135 180 Frequency ( Hz ) - 20 - 30 - 40 1 100 10k 1M rate : 1.5V/150A Phase Amplitude Phase ( deg. ) - 180 - 135 - 90 - 45 135 180 Frequency ( Hz ) - 50 Amplitude ( dB,0dB=1V )
9274 Frequency characteristics
9276 Frequency characteristics
G Incorporates our custom-developed InSb thin-film Hall element Applicable sensor : 9274/9276 Measurement ranges : 0.1/0.2/0.5/1/2/5/10A (using 9274) 1/2/5/10/20/50/100A (using 9276) Output voltage : 1 V per range Functions : Zero adjust, degaussing, filter, coupling functions and overload indication (input up to 100% of range) ±1.2%rdg. (DC and 45 to 66Hz) (input up to 200% of range) Frequency band width : DC; DC to 10 MHz (-3dB) AC; 0.2 Hz to 10 MHz (-3dB) Crest factor : Not more than 5.5 of range Output resistance : 50 Ω Power supply :100V AC (50/60Hz), (120, 220, and 240V require specification) Power consumption : 15 VA max. Dimensions and mass :Approx. 80(W)✕125(H)✕260(D) mm, 1750 g Accessories : Power cord, spare fuse, 9177 input/output cord
I 9277 to 9279 UNIVERSAL CLAMP ON CT Specifications I 9555 Specifications I 9270 to 9272 CLAMP ON SENSOR Specifications 9277 9278 9279 Rated current (AC/DC) 20 A 200 A 500 A Output voltage (AC/DC) 2 V f.s. Accuracy DC and 45Hz to 66Hz After demagnetization and at least 30 min. warm-up Phase:within ±0.2˚(DC has no provision) Frequency characteristics (amplitude) (deviation from accuracy) DC to 1 kHz : within ±1.0% 1 k to 50 kHz : within ±2.5% 50 k to 100 kHz : within ±5% DC to 1 kHz: within ±1.0% 1 k to 10 kHz: within ±2.5% 10 k to 20 kHz: within ±5% Frequency characteristics (phase) (DC has no provision) DC to 1 kHz : within ±0.5˚ 1 k to 50 kHz : within ±2.5˚ 50 k to 100 kHz : within ±5.0˚ DC to 1 kHz: within ±0.5˚ 1 k to 10 kHz: within ±2.5˚ 10 k to 20 kHz: within ±5.0˚ Output resistance 50Ω Input resistance(DC) 0.05 mΩ or less 0.002 m Ω or less 0.001 m Ω or less The maximum permissible input range(DC to 3kHz)*1
50 Arms
(75 Apeak)
350 Arms
(500 Apeak)
650 Arms
(920 Apeak) Temperature characteristics (0 to 40˚C) Sensitivity: within ±0.05% rdg./˚C Offset: within ±0.005% f.s./˚C Operating temperature and humidity 0 to 40˚C [32 to 104˚F] , 80% RH or less (no condensation) Effect of external magnetic fields*2 Max. 0.2 A Max. 1 A Max. 2 A Influence of conductor position within ±0.5%( DC, 55 Hz) within ±1.5% (DC, 55 Hz) Withstand voltage 2200 V AC for 1 minute (electrical circuits to case, electrical circuits to core) Insulation resistance At least 100 MΩ at 500V DC (electrical circuits to case, electrical circuits to core) Max. rated voltage to earth 600 Vrms (850 Vpeak)insulated wire Measurement conductor Diameter max.20 mm [0.79"] Diameter max.40 mm [1.57"] Cable length Approx. 1.5m [59.06"] Power supply voltage ±12 V to ±15 V Power consumption 3.6 W max. 7.2 W max. Dimensions and mass Approx. 176(W)✕63(H)✕34(D) mm; 430 g Approx. 220(W)✕103(H)✕43.5(D) mm; 860 g Supplied accessories 9375 Carrying case 9277 to 9279 UNIVERSAL CLAMP ON CT 9270 to 9272 CLAMP ON SENSOR DC to 100 kHz (9277/9278) 5Hz to 50kHz (9270/9271) 9277 9278 9279 When used together with the 9555 SENSOR UNIT, current waveforms can be observed from DC to 100 kHz (Models 9277/9278). Controlled zero drift allows for stable, long- duration measurements. The probe cannot be used alone: the 9555 is required. The probe cannot be used alone: the 9555 is required. 9555 SENSOR UNIT 9270 9271 9272 Rated current 20 A AC 200 A AC 20/200 A AC Continuous maximum input range 50 Arms Phase accuracy within ±0.2˚(45 to 66Hz) Frequency characteristics (deviation from accuracy) 10 Hz to 30 kHz: ±1.0% 10 Hz to 20 kHz: within ±0.5˚ 5 Hz to 50 kHz: ±2.5% (within ±1.0˚) 10 Hz to1 kHz: ±1.0% (±0.5˚) Output voltage 2 Vf.s. (rated current) Max. rated voltage to earth 600 Vrms (insulated wire) Measurement conductor Diameter max. 20 mm [0.79"] Diameter max. 46 mm [1.81"] 50✕20 mm [1.97"✕0.79"] bus bar Cable length Approx. 3 m [118.11"] Power supply voltage ±12V to ±15V Dimensions and mass Approx. 145(W)✕60(H)✕33(D) mm; 230 g Approx. 62(W)✕174(H)✕33(D) mm; 420 g Supplied accessories 9355 Carrying case
60 Arms/300Arms300 Arms
*1 Maximum non-destructive input above 3 kHz is specified separately. *2 DC and 55 Hz, Magnetic field of 400A/m. Output voltage : 2 Vf.s. Power capacity : ±12 V, ±0.6 A Max. Operating temperature and humidity : 0 to 40˚C [32 to 104˚F] , 80% RH or less (no condensation) Power supply : 85 to 250 V AC(47 to 440 Hz) Power consumption: Approx. 1.7 W (at no load) Withstand voltage : 1500 V AC for 1 minute (power input to case, power input to core) Dimensions and mass : Approx. 50(W)✕100(H)✕180(D) mm, 700g Accessories : Power cord ✕1, 9177 input/output cord✕1, spare fuse ✕1, rubber foot ✕4, rack mounting fittings✕2 Insulation resistance : At least 100 MΩ at 500 V DC (output terminal to core) Storage temperature and humidity : -10 to 50˚C [14 to 122˚F] , 80% RH or less (no condensation)
3274 CLAMP ON PROBE
3275 CLAMP ON PROBE
3276 CLAMP ON PROBE
9270 CLAMP ON SENSOR
9271 CLAMP ON SENSOR
9272 CLAMP ON SENSOR
9274 CLAMP ON AC/DC SENSOR
9276 CLAMP ON AC/DC SENSOR
9277 UNIVERSAL CLAMP ON CT
9278 UNIVERSAL CLAMP ON CT
9279 UNIVERSAL CLAMP ON CT
3269 POWER SUPPLY (for 3273-50 to 3276, 4ch)
3272 POWER SUPPLY (for 3273-50 to 3276, 2ch)
3270 CURRENT MONITOR (for 9274 / 9276)
9555 SENSOR UNIT (for 9270 to 9272 / 9277 to 9279)
9165 CONNECTION CORD (for 3270, BNC-BNC)
I Rated current & Frequency characteristics I Option DC 1 10 100 1k 10k 100k 1M 10M 100M Frequency (Hz) AC/DC AC ! WARNING CLAMP-E2-4XM-01H Printed in JapanAll information correct as of Oct. 14, 2004. All specifications are subject to change without notice. HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com DISTRIBUTED BY Shanghai Representative Office :
1704 Shanghai Times Square Office
93 Huaihai Zhong Road
Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: info@hioki.cn 1. To avoid short circuits and electric shock accidents when using a clamp-on sensor, use only with power lines carrying voltages within the rating limit of the sensor. 2. To avoid short circuits and electric shock accidents when the clamp-on sensor is open, do not use on bare conductors. 500A 20A 200A 150A 500A 30A 20A 9279 : DC to 20kHz 3275 : DC to 2MHz 9272(20/200A) : 5Hz to 10kHz 9271 : 5Hz to 50kHz 9278 : DC to 100kHz 9276 : DC to 1MHz 3274 : DC to 10MHz 3276 : DC to 100MHz 9270 : 5Hz to 50kHz 9277 : DC to 100kHz 9274 : DC to 10MHz 3273-50 : DC to 50MHz 3269 3272 3270 9555 9165 Wave MonitoringLevel Monitoring