Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

...Before They Catch You! POWER QUALITY ANALYZER Power Measuring Instruments 3197 The Most Comprehensive Portable PQA on The Market Catch Power Quality Problems on the Fly... Monitor for: ✔ Inrush Current ✔ Voltage Swells ✔ Voltage Dips ✔ Transient Overvoltage ✔ Interruptions Measure and Record: ✔ Power and Power Factor ✔ Active/Reactive Energy ✔ Demand ✔ Load Changes (with graph display!) ✔ Voltage and Current

For checking the wiring map and vectors in a single window Use the wiring map, vector map and data monitor to check for proper wiring before taking measurements – d o n ’ t m i s s o u t o n important power data just because of minor wiring mistakes! Vector Multimeter Feature 1: Measure Power and Power Quality on Single to Three-Phase Circuits Quickly and Effortlessly 3 1 9 7 3 1973 1 P QA All items are recorded as events so that a quick understanding can be obtained just by viewing the waveform With QuickSet, all you have to do is just Set, Clamp and Measure! Let QuickSet help you take care of all the time-consuming setup procedures. All you need to do is sel ect your circuit, clamp sensor and range, and then let QuickSet do the rest of t he work for you. Feature 2: QuickSet Testing Parameters Automatically Defi ned by QuickSet Redefi ne Thresholds Easily with Intuitive Key Panel Line frequency : Auto Measurement Interval : Auto Nominal Voltage : Auto Event thresholds against nominal voltage Swell : 110% Dip : 90% Interruption : 10% Transient : ON Measure all the necessary power parameters simultaneously Check for sudden inrush during motor startup and diagnose breaker trips due to over current all on the same measurement interface. View RMS data for every half cycle over a 30 second period on a large graph display Feature 3: Power & Power Quality Get a crystal clear picture of the voltage fl uctuation on all channels Power & Energy Power Quality ✓ Voltage ✓ Demand ✓ Inrush Current ✓ Current ✓ Load Changes ✓ Voltage Swells ✓ Frequency ✓ THD(voltage) ✓ Voltage Dips ✓ Power and Power Factor ✓ Active/Reactive Energy ✓ Transient Overvoltage ✓ Voltage Fluctuation (dips and swells) ✓ Interruptions A quick glance at the correct vector map will show you if your wiring is correct

M E A S U R E lConvenient Stand for Hands-free Viewing Type N U1 U2 U3 Region 1 Black Red Yellow Blue Japan, U.K.

2 Blue Orange Black Gray EU (new)

3 Black Yellow Green Red China

4 Blue Black Red White EU (former)

5 White Black Red Blue N. America Select from 5 Types of Color-coded Input Terminal Labels to Suit Your Application Region lPull Strap Through for Ultimate Portability lUSB Port for PC Compatibility lAC Adapter for Quick Recharge or Long Recordings lPower Switch lRugged and Durable Casing to withstand even the toughest environments and uses WIRING REC&EVENT Setting Up is as Easy as 1-2-3 QuickSet Use the correct vector diagram to check that your wiring is right before measuring, particularly useful when measuring 3-Phase circuits Use QuickSet to automatically set the default values for line frequency, nominal voltage, interval, and power quality thresholds for event detection Select your clamp sensor Select your wiring1 Make detailed settings on how and when to measure, and customize your level of event detection as desired. Toggle between screens to customize your measurement settings WAVEFORM VECTOR Monitor Trends while Recording RMS, Phase Angle and Lead and Lag Toggle between screens using VIEW key for instantaneous power data One-touch switching between graph and numerical data Full-color waveforms and RMS readings Obtain real-time moving data on voltage, current, power, and more!

(even while measuring) RMS DIP/SWELL DEMAND Auto-Data Compression Lets You Record for up to 125 Days Find the max, min and average values for any point using the cursor function Get a detailed picture during voltage anomalies - fl uctuation range for all 3 channels are displayed Demand Graph and maximum and average values displayed in one window ✓ Consumed & Regenerated Active Power ✓ Lag and Lead of Reactive Power Toggle between the trend graphs for a complete analysis of the power situation HARMONICS DMM GRAP/LIST Harmonic waveforms of voltage, current and active power to the 50th order Toggle between screens using VIEW key for instantaneous power data DETAIL WAVEFORM RMS INRUSH Identify Power Quality Problems Switch between voltage and current graphs, and zoom in on the time axis at the touch of a button Display events AND their waveforms at the same time RMS voltage fl uctuations such as swells and dips are clearly displayed at event detection Inrush current fl uctuations are captured in RMS at a fast 10ms sampling rate and displayed across a 30-second window Toggle between events for a complete picture of the power anomaly Record up to 20 graphs in internal memory Store up to

50 Events"I" marks an

select to display the fi ner details of any event

Mobility, Portability Plus Convenient Data Transfer Right to Your PC Standard 3197 Package Fulfi lls All the Requirements for Checking Voltage Anomalies Carrying Case USB Cable Voltage Cords Rechargeable Battery Pack AC Adapter To measure current and power , please select one or more of our HIOKI Clamp On Sensors detailed on the back of this catalog. <Measurement Specifications (Guaranteeed Accuracy Period: 1 Year) RMS Voltage and Current True RMS (200 ms calculation ) Voltage Accuracy ±0.3% rdg. ±0.2%f.s Voltage (1/2) RMS Measurement True RMS (one cycle calculation refreshed every half cycle) Current (1/2) RMS Measurement True RMS (half-cycle calculation, half-cycle voltage synchro nized) Frequency Effective Measurement range: 45.00 to 66.00 Hz Accuracy ±0.01 Hz ±1 dgt. (when input is at least 10% of range) Active Power Accuracy (for consumption and regeneration) + clamp-on sensor accuracy (P.F.=1) Reactive Power Accuracy (for lags and leads) ±1 dgt. of calculation from each measurement value Apparent Power Accuracy ±1 dgt. of calculation from each measurement value Power Factor and Displacement Power Factor Accuracy (leading phase indicated) ±1 dgt. of calculation from each measurement value (DPF calculated from phase difference between fundamental voltage and current waveforms Active or Reactive Energy Consumption Selectable between consumption, regeneration, lag and lead Accuracy ±1 dgt. applied to active and reactive power measurement accuracy Demand Selectable between active or reactive power Accuracy ±1 dgt. applied to active and reactive power measurement accuracy Harmonic Analysis Orders Up to 50th (2048 points/window, rectangular) Harmonic Voltage, Current and Power Accuracy (accuracy is not defined for harmonic power) (add accuracy of clamp sensor to harmonic current accuracy) Other Measurement Items Peak Voltage and Current, K Factor, Voltage Unbalance Factor, Max/Min/Ave of Time Series <Event Detection Voltage Swells (Rise), Voltage Dips (Drop), Interruptions RMS value detected using voltage (1/2) measured every half cycle Inrush Current RMS value detected using current (1/2) every half cycle Transient Overvoltage Detection Range: 50 Vrms (±70.7 Vpeak equiv.) or more, 10 to 100 kHz Timer Detection Detect events at preset intervals selectable from OFF, 1, 5, 15 or 30 minutes; 1, 2 or 12 hours; or 1 day Manual Detection Detect events when keys are pressed Thresholds Set to OFF or to specified value, except for detection of transient overvoltages. (Waveform recording not available for transients.) Event Recording Lengths Waveform 20ms before detection + 200ms upon detection + 20ms after detection Event voltage fluctuation graph 0.5s before + 2.5s after detection Inrush current graph 0.5s before + 29.5s after detection Maximum Number of Recordable Events 50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current graph, 1000 event counts <Input Specifications Wiring Configurations Single-phase 2-wire (1P2W), single-phase 3-wire (1P3W), three-phase 3-wire (3P3W2M and 3P3W3M), three-phase four-wire (3P4W and 3P4W2.5E) Measurement Line frequency Auto-select (50/60 Hz) Maximum Allowable Input Voltage Voltage input terminal: 780 V AC (1103 Vpeak) Current input terminal : 1.7 V AC (2.4 Vpeak) Maximum Rated Voltage to Ground Voltage input terminal: CATIII 600 V AC, CATIV 300 V AC (50/60 Hz) Current input terminal : per clamp-on sensors used Measurement Method Simultaneous digital sampling of voltage and current (sampling frequency: 10.24 kHz per channel) Voltage Measurement Range 600.0V (Crest factor 2 or less) Current Measurement Range: Manual ranging according to clamp sensor (Crest factor 3 or less) Clamp Sensor Range Clamp Sensor Range 9657-10, 9675 500.0 mA/5.000 A 9661, 9667 (500A) 50.00 A/500.0 A 9694, 9695-02 5.000 A/50.000 A 9669 100.0 A/1.000 kA 9660, 9695-03 10.00 A/100.0 A 9667 (5000A) 500.0 A/5.000 kA Power Measurement Range: Depends on combination of current range and measurement line A PQA that TRULY fi ts in the palm of your hand.

6 Hours of Continuous

Non-volatile Ni-MH rechargeable battery pack keeps important measurement data in memory even after power is turned off. Feature 5: Compact Design Makes for Long Battery Life Connect to multiple 3197 units simultaneously using a USB hub Two Integrated Programs for Data Download and Viewing Standard USB connection lets you d o w n l o a d d a t a a t a s n a p, a n d immediately view your measurements with the DataViewer Feature 4: Bundled PC Application Software Open downloaded recordings with DataViewer to manage and process your captured power data on your PC. Event List Event Details Time Plot Graph Event Waveform Settings

HEAD OFFICE :

81 Koizumi, Ueda, Nagano, 386-1192, Japan

TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION :

6 Corporate Drive, Cranbury, NJ 08512 USA

TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com DISTRIBUTED BY All information correct as of May. 31, 2006. All specifications are subject to change without notice. 3197E1-65E-10K Printed in Japan Shanghai Representative Office :

1310 Shanghai Times Square Office

93 Huaihai Zhong Road

Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: info@hioki.cn <CLAMP ON SENSOR SPECIFICATIONS MODEL 9694 9660 9661 9669 9667 9695-02 9695-03 Measurable conductor diameter φ15mm φ46mm φ55mm, 80×20mm φ254mm φ15mm Primary current rating AC 5A AC 100A AC 500A AC 1000A AC 500A/5000A AC 50A AC 100A Output voltage AC 10mV/A AC 1mV/A AC 1mV/A AC 0.5mV/A AC 500mVf.s. AC 10mV/A AC 1mV/A Accuracy Amplitude Phase (5Hz to 5kHz) within ±2° within ±1° within ±0.5° within ±1° within ±1° (minimum 10% input) within ±2° within ±1° Frequency characteristic (accuracy devi ation) within ±1.0% at 40Hz to 5kHz (9669: within ±2.0%) ±3dB at 10Hz to 20kHz within ±1.0% at 40Hz to 5kHz Max. rated voltage to earth (insulated condu ctor) 300Vrms 300Vrms 600Vrms 600Vrms 1000Vrms 300Vrms Maximum allowable input (45 to 66 Hz) 50A continuous 130A continuous 550A continuous 1000A continuous 10000A continuous 60A continuous 130A continuous Dimensions and weight 46W×135H×21Dmm, 230g 46W×135H×21Dmm, 230g 77W×151H×42Dmm, 360g 100W×188H×42Dmm, 590g Sensor length 910mm, 140g 51W×58H×19Dmm, 50g Requirements 9445-02/03 AC Adapter (Option) 9219 Connection Cord (3m; Option) CAT III 300V 3m cord 3m cord CAT III 300V CAT III 600V 3m cord CAT III 600V 3m cord CAT III 1000V 2m from sensor to circuit 1m from circuit to connector CAT III 300V CAT III 300V MODEL 9675 9657-10 CAT III 300V 3m cord CAT III 300V 3m cord Measurable conductor diameter φ30mm φ40mm Primary current rating AC 10A AC 10A Output voltage AC 100mV/A AC 100mV/A Amplitude Accuracy Phase Accuracy ( 50/60Hz) within ±5° within ±3° Residual Current 1mA (10A on forward and return) 5mA (100A on forward and return ) Frequency characteristic (accuracy devi ation) within ±5% at 40Hz to 5kHz within ±3% at 40Hz to 5kHz Max. rated voltage to earth 300Vrms (insulated conductor) Maximum allowable input 10A continuous 30A continuous Dimensions and weight 60W×113H×24Dmm, 160g 74W×145H×42Dmm, 380g Notes Not compatible with power measurements <3197 STANDARD BUNDLE CONFIGURATION Includes all the equipment you need to measure voltage. For current or power measurements, please select from our wide assortment of clamp on sensors. 9438-05 VOLTAGE CORD (3m cord length ), 9459 BATTERY PACK, 9418-15 AC ADAPTER, USB Cable, Input Terminal Labels, Input Cord Labels, 3197 Applications PC Pro gram (CD-ROM), strap, carryin g case , measurement guide, instruction manual <COMPLETE LIST OF OPTIONS 9660 9661 9667 9669 9694 9695 -02 9695-03 9219 9657 -10 9675 9438 -05 9418-15 9459 9624-50 CLAMP ON SENSOR (100A) CLAMP ON SENSOR (500A) FLEXIBLE CLAMP ON SENSOR (5000A) CLAMP ON SENSOR (1000A) CLAMP ON SENSOR (5A) CLAMP ON SENSOR (50A) CLAMP ON SENSOR (100A) CONNECTION CORD (for the 9695-02/9695-03) CLAMP ON SENSOR (10A) CLAMP ON SENSOR (10A) VOLTAGE CORD (bundled with the standard 3197) AC ADAPTER (bundled with the standard 3197) BATTERY PACK (bundled with the standard 3197) PQA-HiVIEW Pro PC Application Software (available Fall 2006) < BASIC SPECIFICATIONS Display 4.7-inch color STN LCD Display languages English, Japanese or Chinese (Simplified) Display refresh rate Approx. once per second Clock functions Auto calendar, auto leap year, 24-hour format Real-Time Clock accuracy Within 13 seconds/month Internal Memory Capacity 4MB Maximum recording time 125 Days Interval Settings AUTO, 1, 5, 15 and 30 min., and 1 hour (AUTO sequentially selects 1, 2, 10, 30 seconds, 1, 5, 15 and 30 min., and 1 hour automatically) Demand period 15 min., 30 min. and 1 hour Recordable Items All parameters (incl. max/min/average values) < INTERFACE SPECIFICATIONS Interface USB 2.0 (Full Speed) Connection destination Computer operating on Windows 2000/XP < ENVIRONMENTAL AND SAFET Y-RELATED SPECIFICATIONS Operating environment Indoors, up to 2000 m (6562-ft.) ASL Temperature and humidity Storage -10 to 50°C (14 to 122°F), 80% RH or less (non-condensating) Operation 0 to 40°C (32 to 104°F), 80% RH or less (non-condensating) Applicable standards Safety EN61010-1: 2001, Pollution degree 2, Measurement Categories III (600 V) and IV (300 V) (anticipated transient overvoltage 6000 V) EMC EN61326:1997 + A1:1998 + A2:2001 + A3:2003 Class A; EN61000-3-2:2000, EN61000-3-3:1995 + A1:2001 Power source Model 9418-15 AC Adapter or Model 9459 Battery Pack (Maximum rated power: 23 VA (with AC adapter) Continuous operating time with battery pack Approx. 6 hours (after full charge, with 5 min. auto-off LCD backlight) Dimensions and mass 128 W × 246 H × 63 D mm (5.04”W × 9.69”H × 2.48”D) (including stand) Approx. 1.2 kg (42.3 oz.) (with battery pack) 3P4W Circuit testing of motors and breakers:

3197 Standard Package + 9661 (500A Sensor)×3

3P4W Circuit testing of external CTs:

3197 Standard Package + 9694 (5A Sensor)×3

3P Leakage testing:

3197 Standard Package + 9675 (10A Sensor)×3

<SUGGESTED OPTIONS for POWER ME ASUREMENTS