The 2450-EC Graphical Potentiostat brings speed, flexibility, and simplicity right to your fingertips. Its innovative graphical user interface (GUI) and advanced, capacitive touchscreen technology allow intuitive usage and minimize the learning curve to enable researchers, scientists, and students to learn faster, work smarter, and invent easier. The 2450-EC is a versatile instrument, particularly well-suited for research and development in fundamental electrochemical lab research, characterizing the next generation of materials and electrolytes, new energy storage devices, and faster, smaller sensors. 2450-EC Graphical Potentiostat Datasheet Key Features

  • Perform Cyclic, Squarewave, or Galvanic Voltammetry, Chronoamperometry, and Chronopotentiometry
  • Simplified user interface for faster test setup and analysis of results
  • Real-time plotting of voltammograms on the front panel
  • Analytical graph cursors for immediate analysis of results without the need for a PC
  • Create libraries of reusable, customizable experimental software with built-in scripting
  • Screen capture function allows copying test results from the display to reports
  • 10 nV and 10 fA measurement sensitivity
  • Front panel input banana jacks; rear panel input triaxial connections
  • Context-sensitive help function minimizes learning
  • Front-panel USB 2.0 memory I/O port for transferring data, test scripts, or test configurations While potentiostats are excellent instruments for electrochemistry applications, they typically lack any front panel display and control knobs, often are 2-quadrant systems only, and must be completely controlled by a computer with software that is not always open for users to customize tests beyond what the software can do. The 2450-EC includes a wide range of voltages and currents for sourcing or measuring, nV / fA sensitivities, and high impedance sense leads with a typical input resistance of 50 G ohms and only 1pA of input bias current, typically acceptable with a wide variety of reference electrodes. The 2450-EC can run internal application test scripts so electrochemistry meaurements can be run without the use of an external computer. Results are immediately displayed right on the instrument front panel touchscreen. Connecting the 2450-EC to a 2-, 3-, or 4-electrode cell is simple with the included translation cable. A Tektronix Company

TEK.COM2 Learn Faster; Work Smarter; Invent Easier Unlike traditional potentiostats that lack a user-interface front panel to interact with, the 2450-EC features a five- inch, full-color, high resolution touchscreen that facilitates ease of use, and optimizes overall speed and productivity. Built-in, context-sensitive help enables intuitive operation and minimizes the need to review a separate manual. These capabilities combined with its application versatility make the 2450-EC inherently easy to use for basic and advanced measurement applications, regardless of your experience level with electrochemistry instruments. Convert Raw Data into Information A full graphical plotting window converts raw data and displays it immediately as useful information, such as cyclic voltammograms. The touch screen interface makes it easy to observe, interact with, and explore measurements with “zoom and pinch” simplicity. By using the built-in graphing cursors, you can immediately analyze your data without a computer. All graphic screens can be saved to a USB thumb drive for incorporation into reports and journals. Using the graphical sheet view, test data can also be displayed in tabular form. The instrument supports exporting data to a spreadsheet for further analysis, dramatically improving productivity for research and development. This combination of high performance and high ease of use offers unparalleled insight into your test results. Electrochemical Cell Reference Electrode Working Electrode Counter Electrode The 2450-EC can be easily connected to a 3-electrode cell. 2450-EC Cyclic Voltammetry Menu 2450-EC Cyclic Voltammetry Test Configuration Screen Graph view of results

TEK.COM 3 2450-EC Graphical Potentiostat Test Applications The 2450-EC’s built-in scripting language enables electrochemists, chemists, and materials scientists to create libraries of reusable, customizable experimental software for running tests including cyclic voltammetry, chronoamperometry, chronopotentiometry, and more. The following electrochemistry test scripts are loaded in the internal memory of the 2450-EC.

  • Cyclic Voltammetry: Potential is swept at a user programmable scan rate between two to four defined vertices while current is measured. Current is measured using an analog integration method. This application can also be used to perform Linear Sweep Voltammetry.
  • Open Circuit Potential: Measures the cell potential difference between two electrodes with high input impedance as a function of time.
  • Potential Pulse and Square Wave with Current Measure: The 2450-EC sources potential at programmable peak and base levels and the resulting current is recorded at the pulse peak level.
  • Current Pulse and Square Wave with Voltage Measure: The 2450-EC sources current at programmable peak and base levels and the resulting potential is recorded at the pulse peak level.
  • Chronoamperometry: The potential is stepped to a programmed value and the resulting current is measured as a function of time.
  • Chronopotentiometry: The current is stepped to a programmed value and the resulting potential is measured as a function of time. In addition to pre-loaded test scripts, the built-in scripting language enables the user to create their own library of electrochemistry test scripts that can be modified as the test and measurements evolve. Built-in real-time graphing, charting, scope-like cursors, and data display spreadsheet for export simplifies converting test results into useful information. Typical Applications Ideal for electrochemical research and development in a wide variety of applications studies, including:
  • Basic Analytical Research – Electrochemical cells – Electrode studies – Solid electrolytes
  • Materials Research – Electrode compositions – Electrolyte solutions – Ceramics, polymers, ferro/ piezoelectrics – Organic semiconductors – Low-k dielectrics – Biomaterials – Nanomaterials – Electrodesposition
  • Energy Systems and Storage – Dye-sensitized solar cells – Batteries – Fuel cells, flow batteries – Supercapacitors
  • Sensors – Environmental monitoring – Industrial process control – Healthcare/medical

TEK.COM4 All-in-One Instrument The 2450-EC offers a highly flexible, four-quadrant voltage and current source/load coupled with precision voltage and current meters. When not used in potentiostat type applications, this all-in one instrument can be repurposed as a general lab instrument, including use as a:

  • Precision power supply with V and I readback
  • True current source
  • Digital multimeter (DCV, DCI, ohms, and power with 6½-digit resolution)
  • Precision electronic load
  • Trigger controller +20V–20V–200V +200V +100mA +1A –100mA –1A Quad. II Quad. I Quad. III Quad. IV 2450-EC power envelope. Ease of Use Beyond the Touchscreen In addition to its five-inch, color touchscreen, the 2450-EC front panel has many features that supplement its speed, user- friendliness, and learnability, including a USB 2.0 memory I/O port, a HELP key, a rotary navigation/control knob, a front/ rear input selector button, and banana jacks for basic bench applications. The USB 2.0 memory port supports easy data storing, saving instrument configurations, loading test scripts, and system upgrades. Plus, all front panel buttons are backlit to enhance visibility in low-light environments. Online HELP key USB 2.0 memory I/O Front/rear input selector Rotary navigation/ control knob 5˝ color graphical touchscreen display 2450-EC front panel with high-resolution, capacitive touchscreen. Comprehensive Built-in Connectivity Rear panel access to rear-input triax connectors, remote control interfaces (GPIB, USB 2.0, and LXI/Ethernet), D-sub 9-pin digital I/O port (for internal/external trigger signals and handler control), instrument interlock control, and TSP-Link ® jacks enables easy configuration of multiple instrument test solutions and eliminates the need to invest in additional adapter accessories.

TEK.COM 5 2450-EC Graphical Potentiostat

  • Native X-Y graphing, panning, and zooming
  • Spreadsheet/tabular viewing of data
  • Saving and exporting data for further analysis
  • Saving of test setups
  • Screenshot capturing of graph
  • Annotation of tests
  • Command line dialog for sending and receiving data
  • HTML help
  • GPIB, USB 2.0, Ethernet compliant Simplified Programming with Ready-to-Use Instrument Drivers For those who prefer to create their own customized application software, native National Instruments LabVIEW ® drivers, as well as IVI-C and IVI-COM drivers are available at www.tektronix.com. Free Instrument Control Start-up Software The 2450-EC can be repurposed for applications beyond electrochemistry as a general purpose lab tool, e.g. I-V testing, leakage testing, battery charge/discharge profiling, etc. KickStart, Keithley’s instrument control non-programming start-up software, lets users start taking measurements in minutes for typical current versus voltage applications. In most cases, users merely need to make quick measurements, graph the data, and store the data to disk to perform analysis in software environments such as Excel. KickStart offers the following functionality:
  • Instrument configuration control to perform I-V characterization Ethernet Triax inputs Digital I/O TSP-Link GPIB Interlock USB Rear panel connections are optimized for signal integrity. With KickStart start-up software, users are ready to take measurements in minutes.

TEK.COM6 Test Script Specifications 2450-EC Cyclic Voltammetry Specifications Potential Range –20 V ≤ E ≤ +20 V Current Measure Ranges 10 μA, 100 μA, 1 mA, 10 mA, 100 mA, 1 A Source Limit (Compliance) 100% of selected current range Scan Rate 0.1 mV/s to 3500 mV/s Potential Step Size During Scanning 100 μV (0.1 mV/s ≤ scan rate < 35 mV/s) 1 mV (35 mV/s ≤ scan rate < 350 mV/s ) 10 mV (350 mV/s ≤ scan rate ≤ 3500 mV/s) Number of Cycles 1 to 100 User Selectable Sampling Intervals Points/Test (10 to 10000) Points/Cycle (10 to 10000) Seconds/Point (0.01 to 100) Points/Second (0.01 to 100) Maximum Total Number of Samples 100,000 2450-EC Open Circuit Potential Specifications Potential Measure Ranges 20 mV, 200 mV, 2 V, 20 V Sample Interval 0.75 s ≤ sample interval ≤ 100 s Number of Samples 1 to 100,000 2450-EC Potential Pulse and Square Wave Specifications Peak Potential –20 V ≤ Epeak ≤ +20 V Base Potential –20 V ≤ Ebase ≤ +20 V Current Measure Ranges 1 μA, 10 μA, 100 μA, 1 mA, 10 mA, 100 mA, 1 A Source Limit (Compliance) 105% of selected current range Pulse Period and Width Current Measure Range = 1 μA 200 ms ≤ period ≤ 3600 s 100 ms ≤ pulse width ≤ (0.99 × period) Current Measure Range > 1 μA 4 ms ≤ period ≤ 3600 s 2ms ≤ pulse width ≤ (0.99 × period) Sample Time Minimum is 166.667 μs. Maximum is lesser of 166.667 ms and (pulse width – 1 ms) Number of Cycles 1 to 100,000 Program Time (1 × period) ≤ program time ≤ (100,000 × period)

TEK.COM 7 2450-EC Graphical Potentiostat 2450-EC Current Pulse and Square Wave Specifications Peak Current –1.05 A ≤ Ipeak ≤ +1.05 A Base Current –1.05 A ≤ Ibase ≤ +1.05 A Potential Measure Ranges 20 mV, 200 mV, 2 V, 20 V Source Limit (Compliance) 105% of selected potential range Pulse Period and Width |Ipeak| and |Ibase| ≤ 1.05 μA 200 ms ≤ period ≤ 3600 s 100 ms ≤ pulse width ≤ (0.99 × period) |Ipeak| or |Ibase| > 1.05 μA 4 ms ≤ period ≤ 3600 s 2 ms ≤ pulse width ≤ (0.99 × period) Sample Time Minimum is 166.667 μs. Maximum is lesser of 166.667 ms and (pulse width – 1 ms) Number of Cycles 1 to 100,000 Program Time (1 × period) ≤ program time ≤ (100,000 × period) 2450-EC Chronoamperometry Specifications Step Potential –20 V ≤ Estep ≤ +20 V Current Measure Ranges 10 nA, 100 nA, 1 μA, 10 μA, 100 μA, 1 mA, 10 mA, 100 mA, 1 A Source Limit (Compliance) 100% of selected current range Number of Steps 1 to 10 Step Duration 10 ms ≤ step duration ≤ 99,999 s Sample Interval 10 ms ≤ sample interval ≤ 100 s Sample Time Minimum is 166.667 μs. Maximum is lesser of 166.667 ms and (sample interval – 5 ms) and (step duration – 5 ms) Maximum Number of Samples 100,000 total for all steps 2450-EC Chronopotentiometry Specifications Step Current –1.05 A ≤ Istep ≤ +1.05 A Potential Measure Ranges 20 mV, 200 mV, 2 V, 20 V Source Limit (Compliance) 100% of selected potential range Number of Steps 1 to 10 Step Duration 10 ms ≤ step duration ≤ 99,999 s Sample Interval 10 ms ≤ sample interval ≤ 100 s Sample Time Minimum is 166.667 μs. Maximum is lesser of 166.667 ms and (sample interval – 5 ms) and (step duration – 5 ms) Maximum Number of Samples 100,000 total for all steps

TEK.COM8 Specifications Voltage Specifications 1, 2 Source Measure 3 Range Resolution Accuracy (23° ± 5°C)

1 Year

±(% setting + volts) Noise (RMS) (<10 Hz) Resolution Input Resistance Accuracy (23° ± 5°C) ±(% rdg. + volts) 20.00000 mV 500 nV 0.100% + 200 μV 1 μV 10 nV >10 GΩ 0.100% + 150 μV 200.0000 mV 5 μV 0.015% + 200 μV 1 μV 100 nV >10 GΩ 0.012% + 200 μV 2.000000 V 50 μV 0.020% + 300 μV 10 μV 1 μV >10 GΩ 0.012% + 300 μV 20.00000 V 500 μV 0.015% + 2.4 mV 100 μV 10 μV >10 GΩ 0.015% + 1 mV 200.0000 V 5 mV 0.015% + 24 mV 1 mV 100 μV >10 GΩ 0.015% + 10 mV Current Specifications 1, 2 Source Measure3 Range Resolution Accuracy (23° ±5°C) 4 ±(% setting + amps) Noise (RMS) (<10 Hz) Resolution Voltage Burden Accuracy (23° ±5°C) ±(% rdg. + amps) 10.00000 nA5 500 fA 0.100% + 100 pA 500 fA 10 fA <100 μV 0.100% + 50 pA 100.0000 nA5 5 pA 0.060% + 150 pA 500 fA 100 fA <100 μV 0.060% + 100 pA 1.000000 μA 50 pA 0.025% + 400 pA 5 pA 1 pA <100 μV 0.025% + 300 pA 10.00000 μA 500 pA 0.025% + 1.5 nA 40 pA 10 pA <100 μV 0.025% + 700 pA 100.0000 μA 5 nA 0.020% + 15 nA 400 pA 100 pA <100 μV 0.020% + 6 nA 1.000000 mA 50 nA 0.020% + 150 nA 5 nA 1 nA <100 μV 0.020% + 60 nA 10.00000 mA 500 nA 0.020% + 1.5 μA 40 nA 10 nA <100 μV 0.020% + 600 nA 100.0000 mA 5 μA 0.025% + 15 μA 100 nA 100 nA <100 μV 0.025% + 6 μA 1.000000 A 50 μA 0.067% + 900 μA 3 μA 1 μA <100 μV 0.030% + 500 μA Temperature Coefficient (0°–18°C and 28°–50°C) ±(0.15 × accuracy specification)/°C. Notes 1. Speed = 1 PLC. 2. All specifications are guaranteed with output ON. 3. Accuracies apply to 2- and 4-wire mode when properly zeroed. 5. Rear panel triax connections only.

TEK.COM 9 2450-EC Graphical Potentiostat Resistance Measurement Accuracy (Local or Remote Sense) 1, 2 Range Default Resolution 3 Default Test Current Normal Accuracy (23°C ±5°C) 1 Year, ±(% rdg. + ohms) Enhanced Accuracy 4 (23°C ±5°C) 1 Year, ±(% rdg. + ohms) <2.000000 Ω 5 1 μΩ User defined Source IACC + Meas. VACC Meas. IACC + Meas. VACC 20.00000 kΩ 10 mΩ 100 μA 0.063% + 3 Ω 0.043% + 1 Ω 200.0000 kΩ 100 mΩ 10 μA 0.065% + 30 Ω 0.046% + 10 Ω 2.000000 MΩ 1 Ω 1 μA 0.110% + 300 Ω 0.049% + 100 Ω 20.00000 MΩ 10 Ω 1 μA 0.110% + 1 kΩ 0.052% + 500 Ω 200.0000 MΩ 100 Ω 100 nA 0.655% + 10 kΩ 0.349% + 5k Ω >200.0000 MΩ 5 — User defined Source IACC + Meas. VACC Meas. IACC + Meas. VACC Temperature Coefficient, (0°–18°C and 28°–50°C) ±(0.15 × accuracy specification)/°C. Source Current, Measure Resistance Mode Total uncertainty = Isource accuracy + Vmeasure accuracy (4-wire remote sense). Source Voltage, Measure Resistance Mode Total uncertainty = Vsource accuracy + Imeasure accuracy (4-wire remote sense). Guard Output Impedance 0.5 Ω (DC) in ohms mode. Notes 1. All specifications are guaranteed with output ON. 2. Accuracies apply to 2- and 4-wire mode when properly zeroed. 3. 6.5 digit measure resolution 4. Source readback enabled. Offset compensation ON. 5. Source Current, Measure Resistance or Source Voltage, Measure Resistance only. For best measurements, use rear panel triax connectors. Operating Characteristics Max. Output Power 20 W, four-quadrant source or sink operation. Source Limits Vsource: ±21 V (≤ 1 A range), ±210 V (≤ 100 mA range) Isource: ±1.05 A (≤ 20 V range), ±105 mA (≤ 200 V range). Overrange 105% of range, source and measure. Regulation Voltage: Line: 0.01% of range. Load: 0.01% of range + 100 μV. Current: Line: 0.01% of range. Load: 0.01% of range + 100 pA. Source Limits Voltage Source Current Limit: Bipolar current limit set with single value. Min. 10% of range. Current Source Voltage Limit: Bipolar voltage limit set with single value. Min. 10% of range. V-Limit / I-Limit Accuracy Add 0.3% of setting and ±0.02% of reading to base specification. Overshoot Voltage Source: <0.1% typical (full scale step, resistive load, 20 V range, 10 mA I-Limit. Current Source: <0.1% typical (1 mA step, RLoad = 10 kΩ, 20 V range). Range Change Overshoot Overshoot into a fully resistive 100 k Ω load, 10 Hz to 20 MHz BW, adjacent ranges: 250 mV typical Output Settling Time Time required to reach 0.1% of final value, 20 V range, 100 mA I-Limit: <200 μ s typical. Maximum Slew Rate 0.2 V/μs, 200 V range, 100 mA limit into a 2 k Ω load (typical). Over Voltage Protection User selectable values, 5% tolerance. Factory default = none. Voltage Source Noise 10 Hz–1 MHz (RMS): 2 mV typical into a resistive load. Common Mode Voltage 250 V DC.

TEK.COM10 Common Mode Isolation >1 GΩ, <1000 pF. Noise Rejection (typical) NPLC NMRR CMRR 0.01 — 60 dB 0.1 — 60 dB 1 60 dB 100 dB* * Except lowest two current ranges ~90dB. Load Impedance 20 nF typical (standard). Stable into 50 μF typical (High-C mode). High-C mode valid for ≥100 μA range s, ≥200 mV ranges. Max. Voltage Drop Between Force and Sense Terminals 5 V. Max. Sense Lead Resistance 1 MΩ for rated accuracy. Sense Input Impedance >10 GΩ. Guard Offset Voltage <300 μV, typical System Measurement Speeds 1 Reading Rates (readings/second) typical for 60 Hz (50 Hz): Script (TSP) Programmed Measure Source-Measure Sweep NPLC/Trigger Origin To Mem. To GPIB To USB To LAN To Mem. To GPIB To USB To LAN 0.01 / Internal 3130 (2800) 2830 (2570) 2825 (2600) 2790 (2530) 1710 (1620) 1620 (1540) 1630 (1540) 1620 (1540) 0.01 / External 2170 (2050) 2150 (2030) 2170 (2040) 2160 (1990) 1670 (1590) 1580 (1500) 1590 (1510) 1580 (1510) 0.1 / Internal 540 (460) 530 (450) 530 (450) 530 (450) 470 (410) 460 (400) 470 (400) 470 (400) 0.1 / External 500 (430) 490 (420) 500 (430) 500 (420) 470 (400) 460 (390) 460 (400) 460 (400) 1.00 / Internal 59 (49) 58 (49) 59 (49) 59 (49) 58 (48) 58 (48) 58 (48) 58 (48) 1.00 / External 58 (48) 57 (48) 58 (48) 58 (48) 57 (48) 57 (47) 57 (48) 57 (48) SCPI Programmed 2 Measure Source-Measure Sweep NPLC/Trigger Origin To Mem. To GPIB To USB To LAN To Mem. To GPIB To USB To LAN 0.01 / Internal 3130 (2800) 3060 (2760) 3000 (2790) 3010 (2710) 1710 (1630) 1610 (1600) 1440 (1380) 1690 (1590) 0.01 / External 2350 (2200) 2320 (2170) 2340 (2190) 2320 (2130) 1680 (1590) 1560 (1570) 1410 (1360) 1660 (1560) 0.1 / Internal 540 (460) 540 (450) 540 (460) 540 (450) 470 (410) 470 (410) 450 (390) 470 (410) 0.1 / External 510 (440) 510 (430) 510 (440) 510 (430) 470 (400) 470 (400) 450 (390) 470 (400) 1.00 / Internal 59 (49) 59 (49) 59 (49) 59 (49) 58 (48) 58 (48) 57 (48) 58 (48) 1.00 / External 58 (49) 58 (49) 58 (49) 58 (49) 58 (48) 58 (48) 57 (47) 58 (48) Notes 1. Reading rates applicable for voltage or current measurements, autozero off, autorange off, filter off, binary reading format, and source readback off. 2. SCPI programming mode. Speeds do not apply to SCPI 2400 mode.

TEK.COM 11 2450-EC Graphical Potentiostat General Characteristics (default mode unless specified) Factory Default Standard Power-Up SCPI Mode. Source Output Modes Fixed DC Level, Memory/Configuration List (mixed function), Stair (linear and log). Source Memory List 100 points max. (SCPI 2400 Mode only). Memory Buffer >250,000 readings. Includes selected measured value(s) and time stamp. Real-Time Clock Lithium battery backup (3 yr. + battery life). Remote Interfaces GPIB IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology. USB Device (rear panel, type B) 2.0 Full Speed USBTMC. USB Host (front panel, type A) USB 2.0, support for flash drives, FAT32. Ethernet RJ-45 (10/100BT). Digital I/O Interface: Lines 6 Input/Output user defined for digital I/O or triggering. Connector 9-pin female D. Input Signal Levels 0.7 V (maximum logic low), 3.7 V (minimum logic high). Maximum Source Current +2.0 mA @ >2.7 V (per pin). Maximum Sink Current –50 mA @ 0.7 V (per pin, solid-state fuse protected). 5V Power Supply Pin Limited to 500 mA @ >4 V (solid-state fuse protected). Handler User definable Start of Test, End of Test, 4 category bits. Programmability SCPI or TSP command sets. TSP Mode Embedded Test Script Processor (TSP) accessible from any host interface. IP Configuration Static or DHCP. Expansion Interface The TSP-Link expansion interface allows TSP enabled instruments to trigger and communicate with each other. LXI Compliance 1.4 LXI Core 2011. Display 5 inch capacitive touch, color TFT WVGA (800×480) with LED backlight. Input Signal Connections Front: Banana. Rear: Triaxial (3-lug). Interlock Active High Input. Cooling Forced air, variable speed. Over Temperature Protection Internally sensed temperature overload puts unit in standby mode. Power Supply 100 V to 240 V RMS, 50–60 Hz (automatically detected at power up). VA Rating 190 volt-amps max. Altitude Maximum 2000 meters above sea level. EMC Conforms to European Union EMC Directive. Safety NRTL listed to UL61010-1 and UL61010-2-30. Conforms with European Union Low Voltage Directive. Vibration MIL -PRF-28800F Class 3 Random.

TEK.COM12 Warm-Up 1 hour to rated accuracies. Dimensions With bumpers and handle: 106 mm high × 255 mm wide × 425 mm deep (4.18 in × 10.05 in × 16.75 in). Without bumpers and handle: 88 mm high × 213 mm wide × 403 mm deep (3.46 in × 8.39 in × 15.87 in.) Weight With bumpers and handle: 4.04 kg (8.9 lbs.). Without bumpers and handle: 3.58 kg (7.9 lbs.). Storage: –25°C to 65°C. Supplied Accessories Electrochemistry Translation Cable Accessory Kit

8608 High Performance Test Leads

CA-180-3A TSP-Link/Ethernet Cable CS-1616-3 Safety Interlock Mating Connector USB-B-1 USB Cable, Type A to Type B, 1m (3.3 ft) Documentation CD Application Test Scripts and Documentation on USB Flash Drive SMU Potentiostats and EC-Upgrade Kit Quick Start Guide Test Script Builder Software (available at www.tekt ronix.com) KickStart Startup Software (available at www.tekt ronix.com) LabVIEW and IVI Drivers (available at www.tekt ronix.com) Available Accessories Test Leads and Probes 1754 2-wire Universal 10-Piece Test Lead Kit

5804 Kelvin (4-Wire) Universal 10-Piece Test Lead Kit

5805 Kelvin (4-Wire) Spring-Loaded Probes

5806 Kelvin Clip Lead Set

5808 Low Cost Single-pin Kelvin Probe Set

5809 Low Cost Kelvin Clip Lead Set

8605 High Performance Modular Test Leads

8606 High Performance Modular Probe Kit

8608 High Performance Clip Lead Set

TEK.COM 13 2450-EC Graphical Potentiostat Cables, Connectors, Adapters 237-ALG-2 3-slot Male Triax Connector to 3 Alligator Clips 237-BAN-3A Triax to Banana Plug 2450-TRX-BAN Triax to Banana Adapter. Converts the 4 Triax adapters on the rear panel to 5 banana jacks 7078-TRX-* 3-slot, Low Noise Triax Cable 7078-TRX-GND 3-slot Male Triax To BNC Adapter (guard removed) 8607 2-wire, 1000V Banana Cables, 1 m (3.3 ft) CA-18-1 Shielded Dual Banana Cable, 1.2 m (4 ft) CAP-31 Protective Shield/Cap for 3-lug Triax Connectors CS-1546 Triax 3-lug Special Shorting Plug. Shorts center pin to outer shield CS-1616-3 Safety Interlock Mating Connector Communication Interfaces and Cables 7007-1 Shielded GPIB Cable, 1 m (3.3 ft) 7007-2 Shielded GPIB Cable, 1 m (6.6 ft) CA-180-3A CAT5 Crossover Cable for TSP-Link/Ethernet KPCI-488LPA IEEE-488 Interface for PCI Bus KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter USB-B-1 USB Cable, Type A to Type B, 1 m (3.3 ft) Triggering and Control 2450-TLINK DB-9 to Trigger Link Connector Adapter. 8501-1 Trigger Link Cable, DIN-to-DIN, 1 m (3.3 ft) 8501-2 Trigger Link Cable, DIN-to-DIN, 2 m (6.6 ft) Rack Mount Kits 2450-BenchKit Ears and Handle for 2450-NFP-RACK and 2450-RACK models 4299-8 Single Fixed Rack Mount Kit 4299-9 Dual Fixed Rack Mount Kit 4299-10 Dual Fixed Rack Mount Kit. Mount one 2450 and one Series 26xxB 4299-11 Dual Fixed Rack Mount Kit. Mount one 2450 and one Series 2400, Series 2000, etc. Test Fixtures 8101-PIV DC Test Fixture Software Options Kickstart Instrument Control Software ACS Basic Edition Semiconductor Parametric Test Software for Component and Discrete Devices

TEK.COM14 Available Services 2450-3Y-EW 1 Year Factory Warranty extended to 3 years from date of shipment 2450-5Y-EW 1 Year Factory Warranty extended to 5 years from date of shipment C/2450-3Y-17025 KeithleyCare ® 3 Year ISO 17025 Calibration Plan C/2450-3Y-DATA KeithleyCare 3 Year Calibration w/Data Plan C/2450-3Y-STD KeithleyCare 3 Year Std. Calibration Plan C/2450-5Y-17025 KeithleyCare 5 Year ISO 17025 Calibration Plan C/2450-5Y-DATA KeithleyCare 5 Year Calibration w/Data Plan C/2450-5Y-STD KeithleyCare 5 Year Std. Calibration Plan

Ordering Information

2450-EC Graphical Potentiostat, 200 V, 1 A, 20 W Instrument Warranty Information Warranty Summary This section summarizes the warranties of the 2450. For complete warranty information, refer to the 2450 Reference Manual. Any portion of the product that is not manufactured by Keithley is not covered by this warranty and Keithley will have no duty to enforce any other manufacturer’s warranties. Hardware Warranty Keithley Instruments, Inc. warrants the Keithley manufactured portion of the hardware for a period of one year from defects in materials or workmanship; provided that such defect has not been caused by use of the Keithley hardware which is not in accordance with the hardware instructions. The warranty does not apply upon any modification of Keithley hardware made by the customer or operation of the hardware outside the environmental specifications. Software Warranty Keithley warrants for the Keithley produced portion of the software or firmware will conform in all material respects with the published specifications for a period of ninety (90) days; provided the software is used on the product for which it is intended in accordance with the software instructions. Keithley does not warrant that operation of the software will be uninterrupted or error-free, or that the software will be adequate for the customer’s intended application. The warranty does not apply upon any modification of the software made by the customer.

Contact Information: Australia* 1 800 709 465 Austria 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Malaysia 1 800 22 55835 Mexico, Central/South America and Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 New Zealand 0800 800 238 Norway 800 16098 People’s Republic of China 400 820 5835 Philippines 1 800 1601 0077 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +82 2 6917 5000 Russia / CIS +7 (495) 6647564 Singapore 800 6011 473 South Africa +41 52 675 3777 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886 (2) 2656 6688 Thailand 1 800 011 931 United Kingdom / Ireland* 00800 2255 4835 USA 1 800 833 9200 Vietnam 12060128 * European toll-free number. If not accessible, call: +41 52 675 3777 Find more valuable resources at TEK.COM in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 020817.SBG 1KW-60118-2