11.06.2013 Page 1 / 8

Redundancy module - QUINT-ORING/24DC/2X10/1X20 - 2320173 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://download.phoenixcontact.com) Active QUINT redundancy module for DIN rail mounting with integrated SFB (selective fuse breaking) technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 10 A or 1 x 20 A, including mounted universal DIN rail adapter UTA 107/30 Product Features Service life of the redundant solution is doubled, thanks to uniform distribution of the load Save energy Permanent monitoring of redundancy Consistent redundancy up to the load Key commercial data Packing unit 1 PCE GTIN Custom tariff number 85044090 Country of origin CHINA Technical data Input data Nominal input voltage 24 V DC Nominal input voltage range <p></p> Nominal input voltage range 18 V DC ... 28 V DC (SELV) Input voltage range DC <p></p> Type of protection Protection against static surge voltages > 30 V Nominal input current IN 2x 10 A (-25 °C ... 60 °C) Nominal input current IN 1x 20 A (-25 °C ... 60 °C)

https://www.phoenixcontact.com/us/produkte/2320173

11.06.2013 Page 2 / 8

Redundancy module - QUINT-ORING/24DC/2X10/1X20 - 2320173 Technical data Input data Maximum current Imax 2x 15 A (-25°C ... 40°C) Maximum current Imax 1x 30 A (-25°C ... 40°C) Output data Nominal output voltage 0.1 V (< DC input) Output current 20 A (Increasing power) Output current 10 A (Redundancy) Derating 60 °C ... 70 °C (2.5%/K) Power loss nominal load max. 2 W (IOUT = 20 A) General data Width 32 mm Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm Depth with alternative assembly 35 mm Net weight 0.4 kg Efficiency > 98 % Degree of protection IP20 Protection class III MTBF (IEC 61709, SN 29500) > 1000000 h (According to EN 29500) Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, no condensation) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Alignable: 5 mm horizontally, 15 mm next to active components, 50 mm vertically Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise immunity EN 61000-6-2:2005 Low Voltage Directive Conformance with Low Voltage Directive 2006/95/EC Standard – Electrical equipment of machines EN 60204 Standard - Electrical safety EN 60950-1/VDE 0805 (SELV) Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204 (PELV) UL approvals UL/C-UL listed UL 508 UL approvals UL/C-UL Recognized UL 60950

https://www.phoenixcontact.com/us/produkte/2320173

11.06.2013 Page 3 / 8

Redundancy module - QUINT-ORING/24DC/2X10/1X20 - 2320173 Technical data General data UL approvals UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) Connection data, input Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 14 Conductor cross section AWG/kcmil max 12 Stripping length 8 mm Screw thread M3 Connection data, output Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 6 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 4 mm² Conductor cross section AWG/kcmil min. 10 Stripping length 7 mm Signaling Output name Redundancy OK, 13/14 Output description Group contact Maximum switching voltage max. 30 V AC/DC Maximum inrush current ≤ 100 mA (short-circuit resistant) Status display LED redundancy OK Note on status display Green Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 16 Conductor cross section AWG/kcmil max 12 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Screw thread M3

https://www.phoenixcontact.com/us/produkte/2320173

11.06.2013 Page 4 / 8

Redundancy module - QUINT-ORING/24DC/2X10/1X20 - 2320173 Technical data Signaling Output name ACB (Auto Current Balancing) OK, 23/24 Output description Contact closed: Δ UIN ≤ 300 mV Maximum switching voltage max. 30 V AC/DC Maximum inrush current ≤ 100 mA (short-circuit resistant) Status display ACB OK LED Note on status display LED bar graph green Classifications ETIM ETIM 3.0 EC000599 ETIM 4.0 EC000599 ETIM 5.0 EC000599 UNSPSC UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 eCl@ss eCl@ss 4.0 27250311 eCl@ss 4.1 27250311 eCl@ss 5.0 27242213 eCl@ss 5.1 27242213 eCl@ss 6.0 27049005 eCl@ss 7.0 27049005 Approvals Approvals Approvals UL Recognized / UL Listed / cUL Recognized / cUL Listed / RINA / GL / cULus Recognized / cULus Listed

https://www.phoenixcontact.com/us/produkte/2320173

11.06.2013 Page 5 / 8

Redundancy module - QUINT-ORING/24DC/2X10/1X20 - 2320173 Approvals Ex Approvals UL Listed / cUL Listed / IECEx / ATEX / cULus Listed Approvals submitted Approval details UL Recognized UL Listed cUL Recognized cUL Listed RINA GL cULus Recognized cULus Listed Accessories Accessories

https://www.phoenixcontact.com/us/produkte/2320173

11.06.2013 Page 6 / 8

Redundancy module - QUINT-ORING/24DC/2X10/1X20 - 2320173 Accessories Assembly adapters - UTA 107/30 - 2320089 Universal DIN rail adapter Assembly adapters - UWA 182/52 - 2938235 Universal wall adapter Assembly adapters - QUINT-PS-ADAPTERS7/1 - 2938196 Assembly adapter for QUINT-PS... power supply on S7-300 rail Drawings

https://www.phoenixcontact.com/us/produkte/2320173

11.06.2013 Page 7 / 8

Redundancy module - QUINT-ORING/24DC/2X10/1X20 - 2320173 Block diagram I...[A] IN2 IN1 Out

30 V AC/DC

https://www.phoenixcontact.com/us/produkte/2320173

11.06.2013 Page 8 / 8