https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 1 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 24 V DC, output: 24 V DC/5 A Product Description QUINT DC/DC converter with maximum functionality DC/DC converters alter the voltage level, regenerate the voltage at the end of long cables or enable the creation of independent supply systems by means of electrical isolation. QUINT DC/DC converters magnetically and therefore quickly trip circuit breakers with six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur. Your advantages Reliable starting of difficult loads, thanks to the static POWER BOOST power reserve with up to 125% nominal current permanently Preventive function monitoring indicates critical operating states before errors occur Constant voltage: output voltage regenerated even at the end of long cables Support conversion to various voltage levels Electrical isolation: for setting up independent supply systems Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356482035 Technical data Dimensions Width 32 mm Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm Depth with alternative assembly 35 mm

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 2 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Technical data Dimensions Installation distance right/left 0 mm / 0 mm (≤ 70 °C) Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C) Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C) Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C) Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested) Ambient temperature (start-up type tested) -40 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Input data Nominal input voltage range 24 V DC Input voltage range 18 V DC ... 32 V DC Extended input voltage range in operation 14 V DC ... 18 V DC (Derating) Current consumption 7 A (24 V, IBOOST) Inrush current < 15 A (typical) Mains buffering time > 10 ms (24 V DC) Input fuse 15 A (internal (device protection)) Recommended breaker for input protection 10 A ... 16 A (Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC ±1 % Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) Nominal output current (IN) 5 A (-25 °C ... 60 °C) POWER BOOST (IBoost) 6.25 A (-25°C ... 40°C permanent, UOUT = 24 V DC ) Selective Fuse Breaking (ISFB) 30 A (12 ms) Derating 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback voltage resistance 35 V DC Protection against overvoltage at the output (OVP) < 35 V DC Max. capacitive load unlimited Active current limitation Approximately 7.2 A Control deviation < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %)

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 3 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Technical data Output data Residual ripple < 20 mVPP Peak switching voltages nominal load < 10 mVPP (20 MHz) Maximum power dissipation in no-load condition 2.4 W Power loss nominal load max. 11.4 W General Net weight 0.7 kg Efficiency > 92 % > 890000 h (40 °C) Insulation voltage input/output 1.5 kV (type test) 1 kV (routine test) Degree of protection IP20 Protection class III Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom Connection data, input Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 8 mm Screw thread M3 Connection data, output Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 7 mm Screw thread M3 Connection data for signaling Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm²

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 4 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Technical data Connection data for signaling Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Screw thread M3 Standards EMC requirements for noise immunity EN 61000-6-1 EN 61000-6-2 EMC requirements for noise emission EN 61000-6-3 EN 61000-6-4 Standard - Electrical safety EN 60950-1/VDE 0805 (SELV) Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage EN 60950-1 (SELV) EN 60204-1 (PELV) Standard - Safe isolation DIN VDE 0100-410 Rail applications EN 50121-4 Conformance/approvals UL approvals UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950-1 UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) Shipbuilding approval DNV GL (EMC B) EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Electrostatic discharge EN 61000-4-2 Contact discharge 8 kV (Test Level 4) Discharge in air 15 kV (Test Level 4) Electromagnetic HF field EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m Frequency range 2 GHz ... 3 GHz Test field strength 10 V/m Comments Criterion A Fast transients (burst) EN 61000-4-4 Input 2 kV (Test Level 3 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Signal 2 kV (Test Level 4 - asymmetrical)

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 5 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Technical data EMC data Comments Criterion A Surge voltage load (surge) EN 61000-4-5 Input 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Output 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 2 - asymmetrical) Comments Criterion A Conducted interference EN 61000-4-6 I/O/S asymmetrical Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Block diagram

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 6 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Classifications eCl@ss eCl@ss 10.0.1 27210901 eCl@ss 4.0 27210900 eCl@ss 4.1 27210900 eCl@ss 5.0 27210900 eCl@ss 5.1 27210900 eCl@ss 6.0 27210900 eCl@ss 7.0 27210901 eCl@ss 8.0 27210901 eCl@ss 9.0 27210901 ETIM ETIM 4.0 EC002542 ETIM 5.0 EC002046 ETIM 6.0 EC002046 ETIM 7.0 EC002046 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121041 UNSPSC 18.0 39121041 UNSPSC 19.0 39121041 UNSPSC 20.0 39121041 UNSPSC 21.0 39121041 Approvals Approvals Approvals BV / LR / NK / ABS / RINA / UL Listed / UL Recognized / cUL Recognized / IECEE CB Scheme / cUL Listed / EAC / EAC / DNV GL / UL Recognized / LR / IECEE CB Scheme / UL Listed / cUL Listed / NK / cUL Recognized / ABS / DNV GL / BV / RINA / EAC / EAC Ex Approvals UL Listed / cUL Listed / UL Listed / cUL Listed Approval details

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 7 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Approvals BV http://www.veristar.com/portal/veristarinfo/generalinfo/ approved/approvedProducts/equipmentAndMaterials 27662/B0 BV LR http://www.lr.org/en 12/20030 NK http://www.classnk.or.jp/hp/en/ 12A013 ABS http://www.eagle.org/eagleExternalPortalWEB/ 15-GD1363806-PDA RINA http://www.rina.org/en ELE112814XG UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 IECEE CB Scheme http://www.iecee.org/ DK-5535-M1 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 EAC EAC-Zulassung

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 8 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Approvals EAC EAC-Zulassung DNV GL https://approvalfinder.dnvgl.com/ TAA000010E UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 LR http://www.lr.org/en 12/20030 IECEE CB Scheme http://www.iecee.org/ DK-5535-M1 UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 NK http://www.classnk.or.jp/hp/en/ 12A013 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 ABS http://www.eagle.org/eagleExternalPortalWEB/ 15-GD1363806-PDA

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 9 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Approvals DNV GL https://approvalfinder.dnvgl.com/ TAA000010E Nominal voltage UN 750 V Nominal current IN 15 A mm²/AWG/kcmil 4 BV http://www.veristar.com/portal/veristarinfo/generalinfo/ approved/approvedProducts/equipmentAndMaterials 27662/B0 BV RINA http://www.rina.org/en ELE112814XG EAC RU*DE*08.B.01873/19 EAC RU*DE*08.B.01873/19 Accessories Accessories Assembly adapter Assembly adapters - UTA 107/30 - 2320089 Universal DIN rail adapter Assembly adapters - UWA 182/52 - 2938235 Universal wall adapter for securely mounting the device in the event of strong vibrations. The device is screwed directly onto the mounting surface. The universal wall adapter is attached on the top/bottom.

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 10 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Accessories Assembly adapters - QUINT-PS-ADAPTERS7/1 - 2938196 Assembly adapter for QUINT-PS... power supply on S7-300 rail Power supply Power supply unit - QUINT-PS/1AC/24DC/10 - 2866763 Primary-switched QUINT POWER supply for DIN rail mounting with SFB (selective fuse breaking) technology, input: 1-phase, output: 24 V DC/10 A Power supply unit - QUINT-PS/3AC/24DC/10 - 2866705 Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 3-phase, output: 24 V DC/10 A Redundancy module Redundancy module, with protective coating - QUINT-ORING/24DC/2X10/1X20 - 2320173 Active QUINT redundancy module for DIN rail mounting with Auto Current Balancing ACB technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 10 A or 1 x 20 A, including mounted UTA 107/30 universal DIN rail adapter Thermomagnetic device circuit breakers Thermomagnetic device circuit breaker - CB TM1 1A SFB P - 2800836 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.

https://www.phoenixcontact.com/pi/products/2320034 09/12/2020 Page 11 / 11 DC/DC converters - QUINT-PS/24DC/24DC/ 5 - 2320034 Accessories Thermomagnetic device circuit breaker - CB TM1 2A SFB P - 2800837 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Thermomagnetic device circuit breaker - CB TM1 12A SFB P - 2800844 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Thermomagnetic device circuit breaker - CB TM1 16A SFB P - 2800845 Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element. Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8