https://www.phoenixcontact.com/pi/products/1985904 01/10/2020 Page 1 / 5 PCB terminal block - MKDS 1,5/ 2-5,08 HT BK - 1985904 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) PCB terminal block, nominal current: 17.5 A, rated voltage (III/2): 320 V, Nominal cross section: 1.5 mm², pitch: 5.08 mm, number of positions: 2, connection method: Screw connection with tension sleeve, mounting: THR soldering, conductor/PCB connection direction: 0 °, color: black, Pin layout: Linear pinning, Solder pin [P]: 3.5 mm. This article can be soldered in the reflow furnace together with SMD components. Your advantages Well-known connection principle allows worldwide use Low temperature rise, thanks to maximum contact force Allows connection of two conductors Designed for integration into the SMT soldering process The latching on the side enables various numbers of positions to be combined Key Commercial Data Packing unit 50 pc GTIN GTIN 4017918929305 Technical data Dimensions Length [ l ] 9.8 mm Pitch 5.08 mm Dimension a 5.08 mm Width [ w ] 10.16 mm Height 13.8 mm Height [ h ] 17.3 mm Solder pin [P] 3.5 mm Hole diameter 1.3 mm General Range of articles MKDS 1,5/..-HT Insulating material group IIIa
https://www.phoenixcontact.com/pi/products/1985904 01/10/2020 Page 2 / 5 PCB terminal block - MKDS 1,5/ 2-5,08 HT BK - 1985904 Technical data General Rated surge voltage (III/3) 4 kV Rated surge voltage (III/2) 4 kV Rated surge voltage (II/2) 4 kV Rated voltage (III/3) 200 V Rated voltage (III/2) 320 V Rated voltage (II/2) 320 V Connection in acc. with standard EN-VDE Nominal current IN 17.5 A Nominal cross section 1.5 mm² Maximum load current 24 A (with a 2.5 mm² conductor cross section) Insulating material PA Flammability rating according to UL 94 V0 Internal cylindrical gage A1 Stripping length 7 mm Number of positions 2 Screw thread M3 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Connection data Conductor cross section solid min. 0.14 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.14 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm² Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm² Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm² Conductor cross section flexible, with ferrule with plastic sleeve max. 1.5 mm² Conductor cross section AWG min. 26 Conductor cross section AWG max. 14 2 conductors with same cross section, solid min. 0.14 mm² 2 conductors with same cross section, solid max. 1 mm² 2 conductors with same cross section, stranded min. 0.14 mm² 2 conductors with same cross section, stranded max. 0.75 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. 0.25 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. 0.5 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. 0.5 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. 1 mm²
https://www.phoenixcontact.com/pi/products/1985904 01/10/2020 Page 3 / 5 PCB terminal block - MKDS 1,5/ 2-5,08 HT BK - 1985904 Technical data Standards and Regulations Connection in acc. with standard EN-VDE CUL Flammability rating according to UL 94 V0 Environmental Product Compliance Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Diagram Type: MKDS 1,5/ 2(-5,08) HT and MKDS 1,5/ 3(-5,08) HT Tested according to DIN EN 60512-5-2:2003-01 Reduction factor = 1 Number of positions: 5 Approvals Approvals Approvals DNV GL / CCA / IECEE CB Scheme / SEV / EAC / cULus Recognized
https://www.phoenixcontact.com/pi/products/1985904 01/10/2020 Page 4 / 5 PCB terminal block - MKDS 1,5/ 2-5,08 HT BK - 1985904 Approvals Ex Approvals Approval details DNV GL https://approvalfinder.dnvgl.com/ TAE00001EV CCA IK-3249 Nominal voltage UN 250 V mm²/AWG/kcmil 2.5 IECEE CB Scheme http://www.iecee.org/ CH-8225 Nominal voltage UN 250 V Nominal current IN 24 A mm²/AWG/kcmil 2.5 SEV https://www.electrosuisse.ch/de/meta/shop/produktezertifikate.html IK-3542-M1 Nominal voltage UN 250 V Nominal current IN 24 A mm²/AWG/kcmil 2.5 EAC B.01742 cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E60425-19770427 B D Nominal voltage UN 300 V 300 V Nominal current IN 15 A 10 A mm²/AWG/kcmil 30-14 30-14
https://www.phoenixcontact.com/pi/products/1985904 01/10/2020 Page 5 / 5 Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8
32825 Blomberg