DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 13

Technical content

  • Monitor load currents from 100 nA to 6 A with high accuracy
  • Measure voltage and current with 6½-digit resolution
  • Capture dynamic load currents as short as 140 µs
  • Output up to 192 W of low noise, linear regulated power
  • Programmable rise and fall times eliminate voltage overshoot and undershoot transients
  • Built-in graphing simplifies analyzing trends or displaying voltage or current waveforms
  • High resolution TFT display and soft-key/icon-based user interface simplify power supply operation
  • Programmable output sequences reduce test times
  • Sink up to 0.45 A to discharge voltage quickly
  • Digital I/O for direct communication with other devices and instruments
  • GPIB, USB, and LAN interfaces
  • Built-in web page simplifies automated control/ monitoring
  • Automate tests easily with KickStart start-up software The Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies are much more than just sources of clean power; they are also precision measurement instruments. They can source stable, low noise voltages as well as monitor load currents over a wide dynamic range from amps to nanoamps. The 2280S-32-6 can output up to 32 V at up to 6 A; the 2280S-60-3 can output up to 60 V at up to 3.2 A. Both supplies use linear regulation to ensure low output noise and superior load current measurement sensitivity. A high resolution color Thin Film Transistor (TFT) screen displays a wide range of information on measurements. Soft-key buttons and a navigation wheel combine with the TFT display to provide an easy-to-navigate user interface that speeds instrument setup and operation. In addition, built-in plotting functions allow monitoring trends such as drift. These supplies provide the flexibility required for both benchtop and automated test system applications. For example, they provide a list mode, triggers, and other speed optimization functions to minimize test time in automated testing applications. DMM-Quality Low Current Measurements with High Resolution Unlike conventional power supplies, Series 2280S supplies can also make measurements with up to 6½ digits of resolution. Voltage output measurements can be resolved down to 100 µV. These supplies measure load currents from 100 nA to amps and can resolve down to 10 nA. Four load current measurement ranges (10 A, 1 A, 100 mA, and 10 mA) support measuring a device’s full load current, standby mode current, and small sleep mode currents with DMM-quality accuracy. The high resolution allows characterizing small changes in load currents with confidence. It also makes it possible to make a broad range of measurements on a single range with excellent accuracy across both low and high current values. Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies A Tektronix Company Datasheet

continent than their test systems. Figure 11. Series 2280S rear panel showing the rear output connector with remote sense inputs, digital I/O, and the three interfaces (GPIB, USB, and LAN).

TEK.COM Specifications 23 °C ±5 °C with 1-hour instrument warm-up. DC Output Ratings 2280S-32-6 2280S-60-3 Voltage 0 to 32 V 0 to 60 V Current 0 to 6 A 0 to 3.2 A Maximum Power 192 W 192 W Voltage1 Source Setting 2280S-32-6 2280S-60-3 Accuracy ± (0.02% + 3 mV) ± (0.02% + 6 mV) Resolution 1 mV 1 mV Measurement2 (0.5V over-range) 2280S-32-6 2280S-60-3 Accuracy ± (0.02% + 2 mV) ± (0.02% + 4 mV) Resolution 0.1 mV 0.1 mV Additional Offset at Faster Measurement Settings 2280S-32-6 2280S-60-3 5½ (0.1 PLC) 0.21 mV 0.40 mV 4½ (0.01 PLC) 1.44 mV 2.7 mV 3½ (0.002 PLC) 7.60 mV 14.25 mV Regulation 2280S-32-6 2280S-60-3 Output Ripple and Noise 2280S-32-6 2280S-60-3 Bandwidth

20 Hz–20 MHz

< 1mVRMS < 2mVRMS < 5mV p-p < 7mV p-p Load Transient Recovery Time Resistive load change 50% load to 100% load or 100% load to 50% load: <50 µs to within 15 mV of V-set. 1 Specifications based on using remote sense connections. For 2-wire connections, add an offset of 0.5 mV/A (Front terminals). 2 6½-digit resolution, 1 PLC reading rate, filter on, autozero on.

TEK.COM Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies Slew Rate: Rising Voltage and Falling Voltage 10 V/s to 100 V/s. Up to 1000 V/s under limited conditions3. 100 V/s (default). Maximum Source Voltage Drop per Lead To maintain specified voltage accuracy: 1 V. Maximum Sense HI and Sense LO Lead Resistance To maintain specified voltage accuracy: 2 Ω. Current Current Limit Setting 2280S-32-6 2280S-60-3 Full-scale Amps 6 A 3.2 A Accuracy ±(0.05% + 5 mA) ±(0.05% + 5 mA) Resolution 0.1 mA 0.1 mA Measurement4 (120% over-range except 10 A) Range Resolution 2280S-32-6 2280S-60-3 Additional Offset at Faster Measurement Settings 5 Measure Resolution and (NPLC) Range 2280S-32-6 2280S-60-3 5½ (0.1 PLC) 10 mA 5.0 µA 5.0 µA 100 mA 20 µA 20 µA

1 A 80 µA 80 µA

10 A 2.0 mA 2.0 mA 4½ (0.01 PLC) 10 mA 20 µA 20 µA 100 mA 40 µA 40 µA

1 A 500 µA 500 µA

10 A 10 mA 10 mA

3½ (0.002 PLC) 10 mA 30 µA 30 µA 100 mA 250 µA 250 µA

1 A 25 mA 25 mA

10 A 75 mA 75 mA

3 100 V/s to 1000 V/s rise and fall slew rates: 2280S-32-6: limited to 5 V changes at a maximum of 3 A; between 0V to 5V, the load current can be up to full load, 6 A 2280S-60-3: limited to 10 V changes at a maximum of 2 A; between 0V and 10V, the load current can be up to full load, 3.2 A. 4 6½-digit resolution, 1PLC integration time, Autozero on, Filter on. 10 mA and 100 mA ranges: Source Delay 2 ms. 1 A and 10 A ranges: Source Delay 1 ms. 5 Filter on, 10 mA and 100 mA ranges: Source Delay 2 ms. 1 A and 10 A ranges: Source Delay 1 ms.

TEK.COM Current Pulse Measurement 6 2280S-32-6 2280S-60-3 Minimum Pulse Width (10 mA and 100 mA range) 7 2.1 ms 2.1 ms Minimum Pulse Width (1 A and 10 A range) 7 140 µs 140 µs Minimum time to capture two consecutive pulses 0.5 ms 0.5 ms Regulation 2280S-32-6 2280S-60-3 Output Ripple and Noise 2280S-32-6 2280S-60-3 Bandwidth

20 Hz–20 MHz <3 mA RMS <3 mA RMS

Maximum Continuous Average Sink Current 2280S-32-6 2280S-60-3 Non-programmable 0.45 A ±15% 0.45 A ±15% System Measurement Speeds Readings/s Settings Concurrent (V + I) Current or Voltage (I or V) Measure Resolution and (NPLC) Autozero On

60 Hz (50 Hz)

‘Read?’ with BUS Transfer ‘*TRG’ into Memory 4½ (0.01 PLC) 8 440 (430) 1915 (1820) 3½ (0.002 PLC) 8 510 (510) 2668 (2650) 6 Settings: Autozero off, 0.002 PLC, Arm Source: External, Trigger Source Immediate, Filter off. 10 mA and 100 mA ranges: Source Delay 2 ms. 1A and 10 A ranges: Source Delay 0 ms or off. 7 Time includes trigger detection, jitter, and 0.002 PLC integration time. 8 Settings: Autozero off, Output Delay off, Source Delay off, voltage output is constant, Measure Count 1000.

TEK.COM Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies Protection Overvoltage Protection (OVP) 2280S-32-6 2280S-60-3 Setting Accuracy ±(0.25% + 0.25 V) ±(0.25% + 0.5 V) Resolution 125 mV 250 mV Response Time 6 ms (typical) 9 6 ms (typical) 9 Overcurrent Protection (OCP) 2280S-32-6 2280S-60-3 Setting Accuracy ±(0.25% + 0.10 A) ±(0.25% + 0.10 A) Resolution 25 mA 12.5 mA Response Time 6 ms (typical) 9 6 ms (typical) 9 Overtemperature Protection (OTP) 2280S-32-6 2280S-60-3 Output Turn-off Temperature >93 °C (typical) >93 °C (typical) Response Time 6 ms (typical) 9 6 ms (typical) 9 Other Timing Data CV to CC Transition Time V-Set = 5 V, I-limit = 0.5 A, Resistive Load change 25 Ω to 2.5 Ω: 2.4 ms. CC to CV Transition Time V-Set = 5 V, I-limit = 0.5 A, Resistive Load change 2.5 Ω to 25 Ω: 1.1 ms. Function Change From detection of bus command to function change completed: 10 ms (typical). Output Off/On From detection of bus command to voltage beginning to decrease: 5 ms (typical). Reverse Leads Actuation 6 ms (typical) 9. General Common Mode Current < 6 µA peak-peak. Chassis Isolation ±240 V, any terminal to chassis. >1 GΩ in parallel with <6.8 nF. Temperature Coefficient Add the following to all accuracy specifications when outside the range, 23 °C ±5 °C: (0.15 × specification)/°C for 0 ° to 18 °C and 28 ° to 40 °C. Measurement Display Modes Voltage and current, voltage only, current only. Measurement Acquisition Control Continuous, Manual, External digital input, PC bus. List Mode Maximum number of stored lists: 9. Number of points in a list: 2–99. List Storage Location: Internal memory or USB memory stick. Math and Filter Functions REL Removes offset from current reading display, Range: –1×10 6 to +1×106. Mx+b Reading = x, M = –1×106 to +1×106, b = –1×106 to +1×106. Filter Moving average, Count 2–100, Window 0.01% to 100%. Memory Buffer 2500 locations; each location contains voltage measurement, current measurement, CV/CC Mode, and time stamp, NVRAM. 9 Time defined as from detection of condition to start of output turn-off.

TEK.COM Display 4.3 in. front panel color display, resolution 480 pixels × 272 pixels. Soft button and navigation wheel control. Display Modes Real time voltage and current readings and settings. Plots of stored data: voltage vs data point, current vs data point, voltage and current vs. data point, 100 point resolution. Plots can also display statistics: mean, maximum, minimum, peak-peak, standard deviation. Table of stored data: time/date, voltage, current. Communications GPIB IEEE-488.2 compliant and status model topology. LAN RJ-45 connector, 10/100BT, Auto MDIX. IP Configuration Static or DHCP. LXI Core 2011, version 1.4, USB USB2.0 device (rear panel, type B), USBTMC compliant. USB2.0 host (front panel, type A), full speed, support USB Flash Drives. Input Connections Front: (2-wire). Adjustable supporting, safety shrouded banana, spade lug, or wire. Rear: (4-wire sense). 6-pin removal screw terminal, safety shrouded cover, removable local sense jumpers. Real-Time Clock Capacitive charged, 20 days between next power on cycle at 23 °C and ≤50%RH. Digital I/O 9-pin female D-sub. 6 Input/Output pins. Input Signal Levels 0.7 V (maximum logic low), 3.7 V (minimum logic high). Input Voltage Limits –0.25 V (Absolute minimum). +5.25 V (Absolute maximum). Maximum Source Current +2.0 mA@ >2.7 V (per pin). Maximum Sink Current –50mA @ 0.7V (per pin, solid-state fuse protected). 5V power supply, limited to 0.5 A @ >4 V (solid-state fuse protected). Trig In minimum pulse ≥4 µs, Logic Low pulse. Meter Ready Pulse, 15–30 µs, Logic Low Pulse. EMC Conforms to European Union EMC directive. Safety U.S. NRTL Listing: UL61010-1 3rd ed 2012 and UL61010-2-030:2012. Canadian Certification: CAN/CSA C22.2 No. 61010-1 3rd ed 2012. European Union Compliance: Low Voltage Directive . Cooling Forced air, side intake and rear exhaust. Power Supply 100 V / 120 V / 220 V / 240 V ±10%. Power Line Frequency 50/60 Hz ±3 Hz, automatically sensed at power-on. Power Consumption 630 VA peak. Operating Environment 0 ° to 40 °C, ≤80% RH up to 35 °C, non-condensing. Altitude: up to 2000 meters. Storage Environment –25 ° to 70 °C. LXI Web Browser Compatible Operating System and Software Windows 2000, Win 7 and XP compatible, supports Web browsers with Java plug-in (requires Java plug-in 1.7 or higher). Web page served by 2280S. Shipping Weight 13.29 kg (29.3 lbs.). Net Weight 10.85 kg (23.9 lbs.). Warranty 3 years.

TEK.COM Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies

Ordering Information

2280S-32-6 Precision Measurement DC Power Supply, 32 V, 6 A 2280S-60-3 Precision Measurement DC Power Supply, 60 V, 3.2 A Supplied Accessories Quick Start Guide KickStart Quick Start Guide LAN Crossover Cable Power Cord Rear Panel Mating Connector with Cover Available Accessories 2280-001 Rear Panel Mating Connector and Cover 2280-TEST-LEAD Power Supply Test Lead Kit, 1000 V, 20 A Rating, 122 cm (4 ft) 174694600 LAN Crossover Cable, 3 m (9.8 ft) USB-B-1 USB Cable Type A to B, 1 m (3.3 ft) 2450-TLINK Trigger Link cable to connect 2280S digital I/O to Trigger Link I/O on other Keithley instruments 4299-7 Universal Fixed Shelf Rack-Mount Kit 4299-8 Single Fixed Rack-Mount Kit 4299-9 Dual Fixed Rack-Mount Kit 4299-10 Dual Fixed Rack-Mount Kit for one 2U Graphical Display Instrument and one Series 26xx Instrument 4299-11 Dual Fixed Rack-Mount Kit for one 2U Graphical Display Instrument and one Series 24xx, Series 2000, or 2U Agilent Instrument KPCI-488LPA IEEE-488.2 Interface Board for the PCI Bus KUSB-488B IEEE-488.2 USB-GPIB Interface Adapter for USB Port with 2 m (6.6 ft) cable 7007-05 Double Shielded Premium IEEE-488 Interface Cables, 0.5 m (1.6 ft) 7007-1 Double Shielded Premium IEEE-488 Interface Cables, 1 m (3.2 ft) 7007-2 Double Shielded Premium IEEE-488 Interface Cables, 2 m (6.5 ft) 7007-3 Double Shielded Premium IEEE-488 Interface Cables, 3 m (10 ft) 7007-4 Double Shielded Premium IEEE-488 Interface Cables, 4 m (13 ft) 2280-001: Rear Panel Mounting Connector and Cover (assembled view on the left, and connector and top and bottom cover shown separately on the right) 2280-TEST-LEAD: Power Supply Test Lead Kit, 1000V, 20A Rating: Contains 122cm (4ft) of cable, spade lug adapters, and alligator clips

TEK.COM Available Services 2280S-32-6-EW 1 Additional Year of Factory Warranty (total of 4 years) 2280S-32-6-5Y-EW 2 additional years of factory warranty beyond the 3-Year factory warranty (total of 5 years) C/2280S-32-6-3Y-STD 3 Calibrations Within 3 Years of Purchase C/2280S-32-6-3Y-DATA 3 (ANSI-Z540-1 compliant) Calibrations Within 3 Years of Purchase C/2280S-32-6-5Y-STD 5 Calibrations Within 5 Years of Purchase C/2280S-32-6-5Y-DATA 5 (ANSI-Z540-1 compliant) Calibrations Within 5 Years of Purchase 2280S-60-3-EW 1 Additional Year of Factory Warranty (total of 4 years) 2280S-60-3-5Y-EW 2 additional years of factory warranty beyond the 3-Year factory warranty (total of 5 years) C/2280S-60-3-3Y-STD 3 Calibrations Within 3 Years of Purchase C/2280S-60-3-3Y-DATA 3 (ANSI-Z540-1 compliant) Calibrations Within 3 Years of Purchase C/2280S-60-3-5Y-STD 5 Calibrations Within 5 Years of Purchase C/2280S-60-3-5Y-DATA 5 (ANSI-Z540-1 compliant) Calibrations Within 5 Years of Purchase

Contact Information: Australia* 1 800 709 465 Austria 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Malaysia 1 800 22 55835 Mexico, Central/South America and Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 New Zealand 0800 800 238 Norway 800 16098 People’s Republic of China 400 820 5835 Philippines 1 800 1601 0077 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +82 2 565 1455 Russia / CIS +7 (495) 6647564 Singapore 800 6011 473 South Africa +41 52 675 3777 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886 (2) 2656 6688 Thailand 1 800 011 931 United Kingdom / Ireland* 00800 2255 4835 USA 1 800 833 9200 Vietnam 12060128 * European toll-free number. If not accessible, call: +41 52 675 3777 Find more valuable resources at TEK.COM in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 040219.SBG 1KW-50894-0