1319004 PHOENIX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 14
Technical content
Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. CHARX connect universal, DC CCS Typ 2, Vehicle charging inlet, up to 500 A in Boost mode, 250 A permanent, 1000 V DC, Single wires, length: 3 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC contacts. Product description Vehicle charging inlet for charging with direct current (DC), compatible with type 2 CCS vehicle charging connectors (EVSE), for installation in electric vehicles (EV). Your advantages Complete product range• Uniform, space-saving dimensions for the installation space and the screw connection points of all Phoenix Contact vehicle charging inlets Developed and produced in accordance with the IATF 16949 automotive standard and ISO 9001 Integrated interlock during charging Manual emergency release of the locking actuator Protected and sealed against dirt and water with a high degree of protection Commercial data Item number 1319004 Packing unit 1 pc Minimum order quantity 1 pc Product key XWCAID GTIN 4063151602277 Weight per piece (including packing) 9,036 g Weight per piece (excluding packing) 9,036 g Country of origin PL CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 1 (14)
General A protective cap is supplied as standard for the DC contacts. Product properties Product type Vehicle charging inlet Product family CHARX connect universal for charging with direct current (DC) for installation in electric vehicles (EV) Application Combined Charging System Charging standard DC CCS Typ 2 Charging mode Mode 4 Customer variations On request Electrical properties Type of signal transmission Pulse width modulation with modulated Powerline communication in accordance with ISO/IEC 15118 / DIN SPEC 70121 Note on the connection method Crimp connection, cannot be disconnected Insulation resistance > 200 MΩ Coding 4.7 kΩ (between PE and PP) Temperature measurement DC contacts: 2x PT1000 (DIN EN 60751) Type of charging current DC Charging power 250 kW Charging current 250 A DC Type of charging current DC Boost Mode Charging power up to 500 kW (Boost Mode, depending on the ambient conditions. For detailed information, see the packing slip in the download area for this item.) Charging current up to 500 A DC Power contact Number 3 (PE, DC+, DC-) Rated voltage 1000 V DC Rated current 250 A DC Signal contact Number 2 (CP, PP) Rated voltage 30 V AC Rated current 2 A Temperature sensors (Pt 1000) Sensor type Pt 1000 Standards/regulations DIN EN 60751 Attachment point 2 sensors for the DC contacts CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 2 (14)
12 V, 4-pos.Locking actuator Right position Possible power supply range at the motor 9 V ... 16 V Maximum voltage for locking detection 12 V Typical motor current for locking 0.25 A Reverse current of the motor max. 1.5 A Max. dwell time with reverse current 1 s Recommended adaptation time 600 ms Pause time after entry or exit path 3 s Service life insertion cycles > 10000 load cycles Lock recognition available Mechanical emergency release available Ambient temperature (operation) -40 °C ... 40 °C Dimensions Vehicle charging inlet Width 108 mm Height 140.25 mm Depth 133.5 mm Bore dimensions Width 117.65 mm Height 90 mm Depth 117.65 mm Material specifications Color (Housing) black (9005) Color (Mating face) black (9005) Material (Housing) Plastic Material (Contact surface) Silver Cable/line Cable length 3 m Cable type Single wires Single-core wires for DC Cable length 3 m Cable structure 2 x 95 mm² Single wire, material Silicone Single wire, color OG External cable diameter 20.60 mm ±0.3 mm Cable resistance ≤ 0.196 Ω/km Single-core wire for PE CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 3 (14)
Cable structure 1 x 25 mm² Single wire, material Silicone Single wire, color GN/YE External cable diameter 8.60 mm ±0.1 mm Cable resistance ≤ 0.743 Ω/km Single-core wires for locking actuator Cable length 1.5 m Cable structure 4 x 0.5 mm² Single wire, material PVC Single wire, color BU/RD, BU/GN, BU/YE, BU/BN External cable diameter 1.60 mm ±0.20 mm Cable resistance ≤ 37.1 Ω/m Single-core wires for temperature sensors Cable length 1 m Cable structure 5 x 0,5 mm² Single wire, material PVC BN/GYSingle wire, color BN/YE/GN External cable diameter 1.60 mm ±0.20 mm Cable resistance ≤ 37.1 Ω/m Single-core wires for Pt 1000 temperature sensors Cable length 1 m Cable structure 3 x 0.5 mm² Single wire, material PVC BN GN Single wire, color YE External cable diameter 1.60 mm ±0.20 mm Cable resistance ≤ 37.1 Ω/m Single-core wires for communication Cable length 1 m Cable structure 2 x 0.5 mm² Single wire, material PVC BKSingle wire, color WH External cable diameter 1.60 mm ±0.20 mm Cable resistance ≤ 37.1 Ω/m Mechanical properties Mechanical data CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 4 (14)
Insertion/withdrawal cycles > 10000 Insertion force < 100 N Withdrawal force < 100 N Environmental and real-life conditions Ambient conditions IP55 (plugged in; when plugged in and ready to operate, the degree of protection is only ensued if both plug-in components are original products from Phoenix Contact or suitable standard- compliant products) Degree of protection (Vehicle charging inlet) IP67 (Inner area of vehicle charging inlet) Ambient temperature (operation) -40 °C ... 40 °C (60°C, maximum (current reduction required, observe the DC contact temperature limit value of 90°C)) Ambient temperature (storage/transport) -40 °C ... 85 °C Altitude 4000 m (above sea level) Standards and regulations Standards IEC 62196-2Standards/regulations IEC 62196-3 Mounting Mounting type Front and rear mounting (0 to 90 degree frontal inclination possible) Mounting hole diameter 6.70 mm (ø) Fixing screws M6 Screws included in the scope of delivery none CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 5 (14)
116,7 14,8Ø 11 9,4 27,46,9 103,5 128,5 108 13,9 28,3 88,3 117,7 137,4 140,3 80,8 101 Ø 6,7 Dimensional drawing Connection diagram Installation positions CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 6 (14)
X₃ X₄X₂X₁ RU RU = 1 k RL = 11 k RU = 1 k RL X (mm) Detection for Vehicle Connector CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 7 (14)
X₃ X₄X₂X₁ RU RU = 1 k RL = 11 k RU = 1 k RL X (mm) Detection for Vehicle Connector Schematic diagram ACDC The Combined Charging System (CCS) principle - standard-compliant charging system for electric vehicles, which supports both conventional AC charging and fast DC charging. Both Vehicle Connectors fit into the CCS Vehicle Inlet. CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 8 (14)
[I] DC [III] DC [II] DC [V] DC [IV] DC Operating instructions CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 9 (14)
M BU/RD BU/GN BU/YE BU/BN 1kR2 10k 0,5 mm² 0,5 mm² 0,5 mm² 0,5 mm² Block diagram of the locking actuator Schematic diagram T [°C] RPTC [/uni03A9] Charging Shutdown shutdown threshold Temperature sensor technology resistance range at AC contacts CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 10 (14)
t [ms] RU RL 200 400 600 800 1000 1200 1400 16000 0 200 400 600 800 1000 1200 1400 1600 -24 -12 t [ms] [V]M Locking states of the locking actuator CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 11 (14)
800 900 1000 1100 1200 1300 1400 1500 -40 -20 100 120 [°C] RPt 1000[Ω] -60 = T(RPt 1000) = a * RPt 1000 - b VAR = +25 °C Pt 1000 characteristic curve at an ambient temperature of 25°C for temperature measurement at the DC contacts CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 12 (14)
ECLASS-11.0 27144706 ECLASS-12.0 27144706 ECLASS-13.0 27144706 ETIM ETIM 9.0 EC002898 UNSPSC UNSPSC 21.0 39121800 CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 13 (14)
Environmental product compliance EU RoHS Fulfills EU RoHS substance requirements Yes Exemption 6(c), 7(c)-I China RoHS EFUP-10Environment friendly use period (EFUP) An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. EU REACH SVHC 2-ethylhexyl 10-ethyl-4,4-dioctyl-7-oxo-8-oxa-3,5-dithia-4- stannatetradecanoate (DOTE)(CAS: 15571-58-1) Lead(CAS: 7439-92-1) REACH candidate substance (CAS No.) 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol(CAS: 119-47-1) SCIP 483d2f0a-5957-4ed1-8cbd-2171c4e48c5c Phoenix Contact 2025 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com CHARX T2HBI12-DC250-3,0M2 - Vehicle charging inlet 1319004 https://www.phoenixcontact.com/us/products/1319004 Apr 11, 2025, 8:21 AM Page 14 (14)