EDS1022-003 EUROPA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
This document must be retained for future reference. It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should also be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS1022-003 Page 1 of 1 EUR PA Enclosed Switch Disconnectors (Boxed Isolators) Technical Data: LB100, 1254P / 3PSN AC-21 Data Range Units LB1004P LB1003PSN LB1254P LB1253PSN Rated Operational Voltage Ue IEC & EN Volts V 690 690 UL Volts V 600 600 Main Switch: Isolating Voltage up to Volts V 750 750 Rated Impulse Withstand Voltage Uimp Volts kV 6 6 Rated Uninterrupted Current Iu Amps A 100 125 Rated Operational Current Ie IEC & EN AC-22A Up to 690V A 100 125 AC-21A Up to 690V A 100 125 AC-1 Up to 690V A 100 125 Rated Operational Power AC-23A (50-60Hz) IEC & EN 3 Phase 220-240V kW 45 55 380 - 440V kW 55 75 500 - 690V kW 90 90 Rated Operational Power AC-3 (50-60Hz) IEC & EN 3 Phase 220-240V kW 37 45 440V kW 45 55 690V kW 55 55 UL Power Rating DOL
3 Phase
120V hp 7.5 7.5 240V hp 20 30 480V hp 30 40 600V hp 40 50
1 Phase
240V hp 7.5 7.5 UL Short Circuit Ratings Fuse rating, class J Amps A 70 125 Fuse rating, class RK5 Amps A - - Rated Fused short circuit current Amps kA 10 10 Short Circuit Capacity (IEC) Max Fuse Size (Type gL) Amps A 63 125 Rated Fused Short Circuit Current Amps kA 30 30 Terminal Specification Single/ Multiple Strand Wire Min-mm2 2.5 2.5 Max-mm2 50 50 Fine Strand with Sleeve Min-mm2 4 4 Max-mm2 50 50 American Wire Gauge AWG 1 1 Recommended Tightening Torque Nm 2.5 2.5
Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS1022-003 Page 2 of 2 EUR PA Enclosed Switch Disconnectors (Boxed Isolators) Technical Data: LB100, 1254P / 3PSN AC-21 Terminal Configuration Mounting Details Dismantling the Cover Procedure to dismantle the cover:
- Ensure the switch is in the OFF position
- Unscrew the cover screws & remove the cover
- For easy wiring the switch can be removed from the base and then clicked back into place once wiring is complete
- After wiring ensure the profile orientation of the actuating spindle & knob shaft are in the same position
- Replace the cover & take care not to overtighten the screws (recommended tightening torque 1.5 Nm)
- Do not install using power driven screwdrivers