10W-BPH LINKCOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
- EMI: CE / Meets FCC
- Comply with Indoor/Outdoor Waterproof (IP 67)
- Warranty: 2 years (refer to LinkCom warranty policy) *REFERENCE: www.linkcom.com.tw *Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information (1) All parameters specified at 230 Vac input unless otherwise noted. (2) All specifications typical at 25℃, unless otherwise noted, at normal line and load. (3) Ripple and noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth. (4) Specified for free-air convection cooling. (5) Minimum load is NOT required for proper operation . (6) 100% Production tested. WITHSTAND VOLTAGE I/P-O/P:4.242 kVdc I/P-CASE:4 kVdc ISOLATION RESISTANCE I/P-O/P :100M Ω / 500 Vdc / 25℃ / 70% RH RELATIVE HUMIDITY 10% to +90%, non-cond. SAFETY UL 1310 / PSE EMI EN55015 / Meets FCC Part15 OVER CURRENT PROTECTION NA OPERATING TEMP. -20 ℃ ~ +60 ℃ STORAGE TEMP. -40 ℃ ~ +80 ℃ SHORT CIRCUIT PROTECTION SCP will restart automatically after the fault condition is removed OVER VOLTAGE PROTECTION OVP will restart automatically after the fault condition is removed OVER TEMP. PROTECTION OTP will restart automatically after the fault condition is removed AC CURRENT <0.3 A 110 Vac; <0.15A 230 Vac INRUSH CURRENT (typ) Cold Start 40 A at 240 Vac LEAKAGE CURRENT < 0.7 mA / 264 Vac ACTIVE POWER FACTOR NA THD NA TURN ON DELAY TIME 3200ms, 2000ms at full load 115 Vac / 230 Vac 0.25 ELECTRICAL SPECIFICATION INPUT VOLTAGE RANGE 90-264 Vac, 127-373 Vdc, Normal: 100-240 Vac INPUT FREQUENCY Range: 47-63 Hz, Normal: 50-60 Hz BPHE010C801-50 9.6 3-12 729-891 ─ 70% 0.25 BPHE010C751-50 9.75 3-13 684-836 ─ 70% 0.25 BPHE010C701-50 10.5 3-15 636-781 ─ 70% 0.25BPHE010C501-50 10 3-20 459-561 ─ 70% 0.25BPHE010C601-50 10.2 3-17 549-671 ─ 70% 0.25 BPHE010C451-50 10.8 3-24 414-506 ─ 70% 0.25 BPHE010C401-50 10 3-25 369-451 ─ 70% 0.25 BPHE010C351-50 10.5 3-30 333-407 ─ 70% 0.25 BPHE010C301-50 10.88 3-34 288-352 ─ 70% 0.25 BPHE010C251-50 10 3-40 234-286 ─ 70% 0.25 BPHE010C201-50 9.6 3-48 216-264 ─ 70% 10W LED Driver 10W-BPH Series Constant Current Mode FEATURES:
- AC Input 90~264 Vac Nominal
- AC Inrush current: 40 A at 240 Vac Cold start PRODUCT SPECIFICATION MODEL DC OUTPUT POWER(W) DC OUTPUT VOLTAGE(V) OUTPUT CURRENT(mA) OUTPUT CURRENT TOLERANCE EFFICIENCY O/P NOISE(P-P,V)
- Protection: SCP / OVP / OTP
- High Operating Ambient Temp.: -20℃ ~ +60℃
- Surge Protection: L-N 0.5 kV
- Safety: UL 1310 / PSE
- RoHS Compliant Linkcom Manufacturing Co., Ltd.
10W-BPH Series Constant Current Mode DIMENSIONS *REFERENCE: www.linkcom.com.tw Tc Max. BPHE010C451 as Tc Max. Reference Linkcom Manufacturing Co., Ltd.
10W-BPH Series Constant Current Mode Output Current vs. Load(BPHE010C701) Efficiency vs. Load(BPHE010C701) 0.600 0.620 0.640 0.660 0.680 0.700 0.720 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% Output Current (A) Load (%) Output Current vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=264 0.0% 10.0% 20.0% 30.0% 40.0% 50.0% 60.0% 70.0% 80.0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% Efficiency (%) Load(%) Efficiency vs. Load Vin=100 Vin=120 Vin=200 Vin=230 Vin=264 Linkcom Manufacturing Co., Ltd.