Document Number: 94089 For technical ques tions, contact: diodes-tech@vishay.com www.vishay.com Revision: 28-May-08 1 Fast Soft Recovery Rectifier Diode, 10 A 10ETF..FPPbF Soft Recovery Series Vishay High Power Products FEATURES/DESCRIPTION The 10ETF06FPPbF fast so ft recovery rectifier series has been optimized for combined short reverse recovery time and low forward voltage drop. The glass passivation ensures stable reliable operation in the most severe temperature and power cycling conditions. The fully isolated package (V INS = 2500 VRMS) is UL E78996 approved. This product series has been designed and qualified for industrial level and lead (Pb)-free.

APPLICATIONS

  • Output rectification and freewheeling in inverters, choppers and converters  Input rectifications where se vere restrictions on conducted EMI should be met PRODUCT SUMMARY VRRM 200 to 600 V VF at 10 A < 1.2 V trr 50 ns TO-220AC FULL-PAK Base cathode AnodeCathode Available RoHS* COMPLIANT MAJOR RATINGS AND CHARACTERISTICS SYMBOL CHARACTERISTICS VALUES UNITS VRRM 200 to 600 V IF(AV) Sinusoidal waveform 10 A IFSM 150 trr 1 A, 100 A/µs 50 ns VF 10 A, TJ = 25 °C 1.2 V TJ - 40 to 150 °C VOLTAGE RATINGS PART NUMBER VRRM, MAXIMUM PEAK REVERSE VOLTAGE V VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V IRRM AT 150 °C mA 10ETF02FPPbF 200 300 210ETF04FPPbF 400 500 10ETF06FPPbF 600 700 ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Maximum average forward current I F(AV) TC = 98 °C, 180° conduction half sine wave 10 AMaximum peak one cycle non-repetitive surge current IFSM 10 ms sine pulse, rated VRRM applied 150 10 ms sine pulse, no voltage reapplied 160 Maximum I2t for fusing I 2t 10 ms sine pulse, rated VRRM applied 112.5 A2s 10 ms sine pulse, no voltage reapplied 160 Maximum I2√t for fusing I 2√t t = 0.1 to 10 ms, no voltage reapplied 1600 A 2√s * Pb containing terminations are not RoHS compliant, exemptions may apply

www.vishay.com For technical questi ons, contact: diodes-tech@vishay.com Document Number: 94089

2 Revision: 28-May-08

10ETF..FPPbF Soft Recovery Series Vishay High Power Products Fast Soft Recovery Rectifier Diode, 10 A ELECTRICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Maximum forward voltage drop V FM 10 A, TJ = 25 °C 1.2 V Forward slope resistance r t TJ = 150 °C 23.5 m Ω Threshold voltage V F(TO) 0.85 V Maximum reverse leakage current I RM TJ = 25 °C VR = Rated VRRM 0.1 mA TJ = 150 °C 3.0 RECOVERY CHARACTERISTICS PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Reverse recovery time t rr IF at 10 Apk

25 A/µs

25 °C 145 ns Reverse recovery current I rr 2.75 A Reverse recovery charge Q rr 0.32µ C Snap factor S 0.6 IFM trr dir dt IRM(REC) Qrr t THERMAL - MECHANICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Maximum junction and storage temperature range TJ, TStg - 40 to 150 °C Maximum thermal resistance junction to case RthJC DC operation 2.5 °C/WMaximum thermal resistance junction to ambient RthJA 62 Typical thermal resistance, case to heatsink RthCS Mounting surface, smooth and greased 0.5 Approximate weight 0.07 oz. Mounting torque minimum 6 (5) kgf · cm (lbf · in)maximum 12 (10) Marking device Case style TO- 220AC FULL-PAK (94/V0) 10ETF06FP

Document Number: 94089 For technical ques tions, contact: diodes-tech@vishay.com www.vishay.com Revision: 28-May-08 3 10ETF..FPPbF Soft Recovery Series Fast Soft Recovery Rectifier Diode, 10 A Vishay High Power Products Fig. 1 - Current Rating Characteristics Fig. 2 - Current Rating Characteristics Fig. 3 - Forward Power Loss Characteristics Fig. 4 - Forward Power Loss Characteristics Fig. 5 - Maximum Non-Repetitive Surge Current Fig. 6 - Maximum Non-Repetitive Surge Current 110 100 150 0 6 Maximum Allowable Case Temperature (°C) Average Forward Current (A) 42 8 130 60°30° 90° 180° 10 12 10ETF .. Series RthJC (DC) = 2.5 °C/W140 120 120° Ø Conduction angle 110 100 150 010 Maximum Allowable Case Temperature (°C) Average Forward Current (A) 6 212 130 60°30° 180° 16 1 8 10ETF .. Series RthJC (DC) = 2.5 °C/W140 120 Ø Conduction period DC 4 8 14 90° 120° Maximum Average Forward Power Loss (W) Average Forward Current (A) 10ETF .. Series TJ = 150 °C 180° RMS limit Conduction angle 60° 30° 90° 120° Ø Maximum Average Forward Power Loss (W) Average Forward Current (A) 10ETF .. Series TJ = 150 °C Ø Conduction period DC 4 8 60° 30° 180° 90° 120° RMS limit 160 1 10 100 Peak Half Sine Wave Forward Current (A) Number of Equal Amplitude Half Cycle Current Pulses (N) 140 100 120 10ETF.. Series Initial TJ = 150 °C at 60 Hz 0.0083 s at 50 Hz 0.0100 s At any rated load condition and with rated VRRM applied following surge. 180 0.01 0.1 1 Peak Half Sine Wave Forward Current (A) Pulse Train Duration (s) 140 100 120 10ETF.. Series Initial TJ = 150 °C No voltage reapplied Rated VRRM reapplied Maximum non-repetitive surge current versus pulse train duration.160

www.vishay.com For technical questi ons, contact: diodes-tech@vishay.com Document Number: 94089

4 Revision: 28-May-08

10ETF..FPPbF Soft Recovery Series Vishay High Power Products Fast Soft Recovery Rectifier Diode, 10 A Fig. 7 - Forward Voltage Drop Characteristics Fig. 8 - Recovery Time Characteristics, TJ = 25 °C Fig. 9 - Recovery Time Characteristics, TJ = 150 °C Fig. 10 - Recovery Charge Characteristics, TJ = 25 °C Fig. 11 - Recovery Charge Characteristics, TJ = 150 °C Fig. 12 - Recovery Current Characteristics, TJ = 25 °C 100 Instantaneous Forward Current (A) Instantaneous Forward Voltage (V) TJ = 150 °C TJ = 25 °C 10ETF.. Series 0.20 0.15 04 0 80 120 160 200 trr - Maximum Reverse Recovery Time (µs) dI/dt - Rate of Fall of Forward Current (A/µs) 10ETF .. Series TJ = 25 °C 0.05 0.10 IFM = 20 A IFM = 1 A IFM = 10 A IFM = 5 A IFM = 2 A 0.4 0.3 04 0 80 120 160 200 trr - Maximum Reverse Recovery Time (µs) dI/dt - Rate of Fall of Forward Current (A/µs) 10ETF .. Series TJ = 150 °C 0.1 0.2 IFM = 20 A IFM = 1 A IFM = 10 A IFM = 5 A IFM = 2 A 1.4 0.6 04 0 80 120 160 200 Qrr - Maximum Reverse Recovery Charge (µC) dI/dt - Rate of Fall of Forward Current (A/µs) 10ETF .. Series TJ = 25 °C 0.2 0.4 1.0 0.8

1.2 IFM = 20 A

IFM = 1 A IFM = 10 A IFM = 5 A IFM = 2 A 2.5 1.5 04 0 80 120 160 200 Qrr - Maximum Reverse Recovery Charge (µC) dI/dt - Rate of Fall of Forward Current (A/µs) 10ETF .. Series TJ = 150 °C 0.5 1.0 2.0 IFM = 20 A IFM = 1 A IFM = 10 A IFM = 5 A IFM = 2 A 04 0 80 120 160 200 Irr - Maximum Reverse Recovery Current (A) dI/dt - Rate of Fall of Forward Current (A/µs) 10ETF .. Series TJ = 25 °C IFM = 20 A IFM = 1 A IFM = 10 A IFM = 5 A IFM = 2 A

Document Number: 94089 For technical ques tions, contact: diodes-tech@vishay.com www.vishay.com Revision: 28-May-08 5 10ETF..FPPbF Soft Recovery Series Fast Soft Recovery Rectifier Diode, 10 A Vishay High Power Products Fig. 13 - Recovery Current Characteristics, TJ = 150 °C Fig. 14 - Thermal Impedance ZthJC Characteristics 04 0 80 120 160 200 Irr - Maximum Reverse Recovery Current (A) dI/dt - Rate of Fall of Forward Current (A/µs) 10ETF .. Series TJ = 150 °C IFM = 20 A IFM = 1 A IFM = 10 A IFM = 5 A IFM = 2 A 0.1 100.0001 0.001 0.01 0.1 1 Square Wave Pulse Duration (s) ZthJC - Transient Thermal Impedance (°C/W) Single pulse 10ETF .. Series Steady state value (DC operation) D = 0.50 D = 0.33 D = 0.25 D = 0.17 D = 0.08

www.vishay.com For technical questi ons, contact: diodes-tech@vishay.com Document Number: 94089

6 Revision: 28-May-08

10ETF..FPPbF Soft Recovery Series Vishay High Power Products Fast Soft Recovery Rectifier Diode, 10 A ORDERING INFORMATION TABLE 1 - Current rating (10 = 10 A) 2 - Circuit configuration: E = Single diode T = TO-220AC 4 - Type of silicon: F = Fast soft recovery rectifier 5 - Voltage code x 100 = V RRM 6 - FULL-PAK 7 - None = Standard production PbF = Lead (Pb)-free 02 = 200 V 04 = 400 V 06 = 600 V Device code 513 24 67

10 E T F 06 FP PbF

LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95005 Part marking information http://www.vishay.com/doc?95009

www.vishay.com Vishay Semiconductors Revision: 20-Jul-11 1 Document Number: 95005 For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 DIMENSIONS in millimeters 5° ± 0.5° 3.3 3.1 5° ± 0.5° 0.9 0.7 2.54 TYP. 2.54 TYP. 10.6 10.4 3.7 3.2 7.31 6.91 0.61 0.38 2.85 2.65 2.8 2.6 1.4 1.3 10° 4.8 4.6 16.0 15.8 16.4 15.4 (2 places)R 0.7 R 0.5 Hole Ø 3.4 3.1 TYP .1.15 1.05 13.56 13.05 Lead assignments Diodes 1 + 2 - Cathode 3 - Anode Conforms to JEDEC outline TO-220 FULL-PAK

Document Number: 91000 www.vishay.com Revision: 11-Mar-11 1 Disclaimer Legal Disclaimer Notice Vishay ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA AR E SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectivel y, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, incl uding without limitation specia l, consequential or incidental dama ges, and (iii) any and all impl ied warranties, including warran ties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of pro ducts for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in gene ric applications. Such statements are not binding statements about the suitability of products for a partic ular application. It is the customer’s responsibility to validate that a particu lar product with the properties described in th e product specification is su itable for use in a particul ar application. Parameters provided in datasheets an d/or specifications may vary in different applications and perfo rmance may vary over time. All operating parameters, including typical pa rameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s term s and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product co uld result in person al injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and it s distributors harmless from and against an y and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.