DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

0.6 0.5 0.4 0.3 0.2 0.1 150 100 (Pa)(inch H2O) 1 2 3 4 5 6 静圧 0 50 100 150 200 (CFM) (m3/min) 27.6 V 24 V 20.4 V 風量 0.6 0.5 0.4 0.3 0.2 0.1 150 100 (Pa)(inch H2O) 1 2 3 4 5 6 静圧 0 50 100 150 200 (CFM) (m3/min) 13.8 V 12 V 10.2 V 風量 0.4 0.3 0.2 0.1 100 (Pa)(inch H2O) 1 2 3 4 5 静圧 0 50 100 150 200 (CFM) (m3/min) 13.8 V 12 V 10.2 V 風量 CATALOG No. C1097B001 '20.1 .IT DCDC Fan 140 mm sq. Static pressure Static pressure AirflowAirflow Static pressure Airflow Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 109P1412H101 With pulse sensor 109P1412M101 With pulse sensor 109P1424H101 With pulse sensor DC Fan 140×140×38 mm San Ace 140 9P type ■ ■General Specifications

  • Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
  • Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only.
  • Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573.
  • Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
  • Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
  • Sound pressure level (SPL) …………… At 1 m away from the air inlet
  • Storage temperature …………………… -30 to +70˚C (Non-condensing) ■ ■Specifications The models listed below have ribs and pulse sensors. Model no. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life [V] [V] [A] [W] [min-1] [m3/min] [CFM] [Pa] [inchH 2O] [dB (A)] [˚C] [h] -20 to +70 40000/60˚C (70000/40˚C) 109P1412M101 0.33 3.96 1900 3.3 117 52 0.209 38 109P1424M101 0.16 3.84 1900 3.3 117 52 0.209 38 109P1448M101 0.09 4.32 1900 3.3 117 52 0.209 38 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 596. Lock sensor

140±0.8 124.5±0.5 140±0.8 124.5±0.5 38±0.5 (5) (5) (10) 4-ø4.3±0.3 +30 300 0 回転方向 風吹出方向 取付用穴 リード線 AWG24 UL 1007 ø150 124.5±0.3 4-ø4.5 138 124.5±0.3 138 ø146 124.5±0.3 4-ø4.5 138 124.5±0.3 138 0.6 0.5 0.4 0.3 0.2 0.1 150 100 (Pa)(inch H2O) 1 2 3 4 5 6 静圧 0 50 100 150 200 (CFM) (m3/min) 55.2 V 48 V 40.8 V 風量 0.4 0.3 0.2 0.1 100 (Pa)(inch H2O) 1 2 3 4 5 静圧 0 50 100 150 200 (CFM) (m3/min) 55.2 V 48 V 40.8 V 風量 0.4 0.3 0.2 0.1 100 (Pa)(inch H2O) 1 2 3 4 5 静圧 0 50 100 150 200 (CFM) (m3/min) 27.6 V 24 V 20.4 V 風量 DC DC Fan 140 mm sq. CATALOG No. C1097B001 '20.1 .IT Outlet sideInlet side Rotating direction Airflow direction Mounting hole Lead wire Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 109P1424M101 With pulse sensor 109P1448H101 With pulse sensor 109P1448M101 With pulse sensor Static pressure Airflow Static pressure Static pressure AirflowAirflow ■ Dimensions (unit: mm) ■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) ■ Options Finger guards page: p. 559 Model no.: 109-719, 109-719H DC Fan 140×140×38 mm San Ace 140 9P type ■ ■General Specifications

  • Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
  • Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only.
  • Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573.
  • Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
  • Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
  • Sound pressure level (SPL) …………… At 1 m away from the air inlet
  • Storage temperature …………………… -30 to +70˚C (Non-condensing) ■ ■Specifications The models listed below have ribs and pulse sensors. Model no. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life [V] [V] [A] [W] [min-1] [m3/min] [CFM] [Pa] [inchH 2O] [dB (A)] [˚C] [h] -20 to +70 40000/60˚C (70000/40˚C) 109P1412M101 0.33 3.96 1900 3.3 117 52 0.209 38 109P1424M101 0.16 3.84 1900 3.3 117 52 0.209 38 109P1448M101 0.09 4.32 1900 3.3 117 52 0.209 38 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 596. Lock sensor