DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
(Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.1 0.2 0.3 0.4 0.5 0.6 0 2 4 6 8 10 4.5 V 5.5 V 5 V 100 0.1 0.2 0.3 150 (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.05 0.10 0.15 0.20 0.25 0.30 0 2 4 6 8 10 0.2 0.1 4.5 V 0.3 5.5 V 5 V 200 150 100 0.3 0.2 0.1 0.2 0.4 0.6 0.8 0.1 0.3 0.5 0.7 4 6 8 10 0 静圧 風量 (inch H2O) (Pa) 13.8 V 12 V 7 V (m3/min) (CFM) DC CATALOG No. C1097B001 '20.1 .IT DC Fan 40 mm sq. Static pressure Airflow Static pressure Static pressure Airflow Airflow Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 109P0405H701 With pulse sensor 109P0405M701 With pulse sensor 109P0412R701 With pulse sensor DC Fan 40×40×15 mm San Ace 40 9P type ■ ■General Specifications
- Material …………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
- Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only.
- Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573.
- Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
- Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
- Sound pressure level (SPL) …………… At 1 m away from the air inlet
- Storage temperature …………………… -30 to +70˚C (Non-condensing) ■ ■Specifications The models listed below have ribs and pulse sensors. Model no. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life [V] [V] [A] [W] [min-1] [m3/min] [CFM] [Pa] [inchH 2O] [dB (A)] [˚C] [h] -20 to +70 109P0412R701 (70000/40˚C) 109P0412S701 10.2 to 13.8 60000/60˚C (90000/40˚C) The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor The mark indicates Short Lead Time Service applicable models. See p. 626 for details.
32±0.3 4-ø3.5±0.3 32±0.3 リード線 AWG24 UL 1007 40 0 40 0 +30 320 0 15 0 (4)(4) (10) 取付用穴 回転方向 風吹出方向 (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.1 0.2 0.3 0.4 0.5 0.6 0 2 4 6 8 10 100 150 10.2 V 0.1 0.2 0.3 13.8 V 12 V (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0 2 4 6 8 10 0.05 0.10 0.15 0.20 0.25 0.30 0.1 10.2 V 0.2 0.3 12 V 13.8 V (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.1 0.2 0.3 0.4 0.5 0.6 0 2 4 6 8 10 0.1 0 100 0.2 0.3 10.2 V 12 V 150 13.8 V (Pa)(inch H2O) (CFM) (m3/min) 静圧 風量 0.1 0.2 0.3 0.4 0.5 0.6 0 2 4 6 8 10 0.1 0 100 0.2 0.3 20.4 V 24 V 150 27.6 V CATALOG No. C1097B001 '20.1 .IT DC DC Fan 40 mm sq. Rotating direction Airflow direction Mounting hole Lead wire Operating voltage range 109P0424H701 With pulse sensor Static pressure Static pressure Airflow Airflow Airflow Static pressure Operating voltage range Operating voltage range Operating voltage range ■ Airflow - Static Pressure Characteristics 109P0412S701 With pulse sensor 109P0412H701 With pulse sensor 109P0412M701 With pulse sensor Airflow Static pressure ■ Dimensions (unit: mm)
32±0.3 32±0.3 (15) (15) 4-ø3.7 38.5 DC CATALOG No. C1097B001 '20.1 .IT DC Fan 40 mm sq. Inlet side, Outlet side ■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) ■ Options Finger guards page: p. 558 Model no.: 109-059, 109-059H