DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Features

– Wear-resistant switching up to 230 V / 2 A – Electrical isolation between input and output 2.5 kV – Integrated protective circuit on the output side – Sealed IP67 housing for protection against external influences – Resistant to vibrations and shocks – Zero voltage switch Suitable PLC basic terminal blocks for OPT-24DC/230AC/2 PLC-BSC-24DC/21-21, PLC-BSC-48DC/21-21, PLC-BSC-24DC/1-1/ACT, PLC-BSC-24DC/1IC/ACT, PLC-BSC-24DC/21HC, PLC-BSC-48DC/21HC, PLC-BSP-24DC/21-21, PLC-BSP-48 DC/21-21, PLC-BSP-24DC/1IC4ACT, PLC-BSP-24DC/21HC, PLC-BSP-48DC/21HC Suitable PLC basic terminal blocks for OPT-60DC/230AC/2 PLC-BSC-60DC/21-21, PLC-BSC-60DC/21HC, PLC-BSP-60DC/21-21, PLC-BSP-60DC/21HC Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com A conversion table is available on the Internet at This data sheet is valid for all products listed on the following page: Power Optocouplers for Switching AC Loads up to 2 A

OPT-...-DC/230AC/2 102829_00_en PHOENIX CONTACT 2 Ordering Data Technical Data Dimensions Figure 1 Dimensions (in mm) Description Type Order No. Pcs./Pck. Power optocoupler for switching AC loads up to 2 A, input voltage 5 V DC OPT- 5DC/230AC/2 29 82 16 8 20 Power optocoupler for switching AC loads up to 2 A, input voltage 24 V DC OPT-24DC/230AC/2 29 82 17 1 20 Power optocoupler for switching AC loads up to 2 A, input voltage 60 V DC OPT-60DC/230AC/2 29 82 18 4 20 Nominal input voltage UN 5 V DC 24 V DC 60 V DC Typical input current at UN 15 mA 7 mA 2.6 mA Typical switch-on time at UN 10 ms 10 ms 10 ms Typical switch-off time at UN 10 ms 10 ms 10 ms Output Data Maximum switching voltage 253 V AC Minimum switching voltage 24 V AC Limiting continuous current 2 A (see "Derating Curve for PLC Power Optocouplers" on page 3) Maximum load value at 25 °C 4 A2s/tP = 10 ms Surge current at 25 °C 30 A for 10 ms Minimum switching current 25 mA Output switching 2-wire floating ground Output wiring RC element Voltage drop on limiting continuous current ≤ 1 V General Data Rated insulation voltage 250 V AC Rated surge voltage 4 kV Nominal operating mode 100% ED Ambient operating temperature range -20 °C ... +60 °C Mounting position Any Mounting see "Derating Curve for PLC Power Optocouplers" on page 3 Degree of contamination 2 Surge voltage category III Inflammability class V0 according to UL 94 Basic insulation According to EN 50178 /G32 /G39 /G31 /G35 /G2C /G37 /G31 /G32 /G2C /G37 /G30 /G2C /G35 /G33 /G2C /G36 /G20 /GB1 /G30 /G2C /G35