DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Features
The key features of this power optocoupler include: – Wear-resistant switching of up to 24 V/5 A – Electrical isolation between the 2.5 kV input and output – Integrated protective circuit on the output side – Ambient temperature of -20°C to +60°C – IP67 housing sealed against external influences – Resistant to vibrations and shocks Suitable PLC Basic Terminal Blocks for OPT-24DC/24DC/5 PLC-BSC-24DC/21-21, PLC-BSC-48DC/21-21, PLC-BSC-24DC/1-1/ACT, PLC-BSC-24DC/1IC/ACT, PLC-BSC-24DC/21HC, PLC-BSC-48DC/21HC Suitable PLC Basic Terminal Blocks for OPT-60DC/24DC/5 PLC-BSC-60DC/21-21, PLC-BSC-60DC/21HC Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com A conversion table is available on the Internet at This data sheet is valid for all products listed on the following page: Power Optocoupler for Switching High DC Loads up to 5 A
OPT-…DC/24DC/5 101804_00_en PHOENIX CONTACT 2 Ordering Data Technical Data Dimensions Figure 1 Dimensions (in mm) Description Type Order No. Pcs./Pck. Power optocoupler for switching DC loads up to 5 A,
5 V DC input voltage
OPT- 5DC/24DC/5 2982113 20 Power optocoupler for switching DC loads up to 5 A,
24 V DC input voltage
OPT-24DC/24DC/5 2982100 20 Power optocoupler for switching DC loads up to 5 A,
60 V DC input voltage
OPT-60DC/24DC/5 2982126 20 Nominal input voltage UN 5 V DC 24 V DC 60 V DC Typical input current at UN 9 mA 7 mA 3 mA Typical switch-on time at UN 10 µs 20 µs 25 µs Typical switch-off time at UN 400 µs 400 µs4 0 0 µs Output Data Maximum switching voltage 33 V DC Minimum switching voltage 3 V DC Limiting continuous current 5 A (see "Derating Curve for PLC Power Optocouplers" on page 3) Surge current at 25°C 15 A for 10 ms Output configuration 2-wire floating Output circuit Protection against polarity reversal, surge protection Voltage drop at limiting continuous current ≤ 200 mV General Data Rated insulation voltage 100 V DC Impulse voltage withstand level 1.5 kV Test voltage: input/output 2.5 kV, 50 Hz, 1 min. Nominal operating mode 100% operating factor Ambient temperature range -20°C ... +60°C Mounting position Any Assembly Can be aligned without spacing Pollution degree 2 Surge voltage category III Inflammability class V0 according to UL 94 Basic insulation According to EN 50178 Standards/specifications IEC 60664, IEC 60664 A, DIN VDE 0110 /G32 /G39 /G31 /G35 /G2C /G37 /G31 /G32 /G2C /G37 /G30 /G2C /G35 /G33 /G2C /G36 /G20 /GB1 /G30 /G2C /G35