III-2016, www.findernet.com H Plug-in timer 85.02 - 2 Pole 10 A 85.03 - 3 Pole 10 A 85.04 - 4 Pole 7 A
- Multifunctions
- Seven time scales, from 0.05 s to 100 h
- 94 series sockets for 35 mm rail (EN 60715) mount with push-in and screw terminal 85.02 85.03 85.04
- 2 pole, 10 A
- AC/DC supply non polarized
- Plug-in for use with 94 series sockets
- 3 pole, 10 A
- AC/DC supply non polarized
- Plug-in for use with 94 series sockets
- 4 pole, 7 A
- AC/DC supply non polarized
- Plug-in for use with 94 series sockets AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) GI: Pulse delayed AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) GI: Pulse delayed AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) GI: Pulse delayed Wiring diagram (without control signal) Wiring diagram (without control signal) Wiring diagram (without control signal) For UL ratings see: “General technical information” page V Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) Rated current/Maximum peak current A 10/20 10/20 7/15 Rated voltage/ Maximum switching voltage V AC 250/400 250/400 250/250 Rated load AC1 VA 2500 2500 1750 Rated load AC15 (230 V AC) VA 500 500 350 Single phase motor rating (230 V AC) kW 0.37 0.37 0.125 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi AgNi Supply specification Nominal voltage (UN) V AC (50/60 Hz) 230…240 230…240 230…240 V AC/DC 12 - 24 - 48 - 110…125 (non polarized) Rated power AC/DC VA (50 Hz)/W 2/2 2/2 2/2 Technical data Specified time range (0.05…1)s, (0.5…10)s, (5…100)s, (0.5…10)min, (5…100)min, (0.5…10)h, (5…100)h Repeatability % ± 2 ± 2 ± 2 Recovery time ms ≤ 20 ≤ 20 ≤ 20 Minimum control impulse ms — — — Setting accuracy-full range % ± 5 ± 5 ± 5 Ambient temperature range °C –20…+60 –20…+60 –20…+60 Protection category IP 40 IP 40 IP 40 Approvals (according to type) SERIES
85 SERIES
Miniature plug-in timers 7 - 10 A
III-2016, www.findernet.com H
Ordering information
Example: 85 series timer, 4 CO (4PDT), 24 V AC/DC supply voltage, AI, DI, GI, SW functions. 8 5 . 0 4 . 0 . 0 2 4 . 0 0 0 0 Series Type 0 = Multifunction (AI, DI, GI, SW)* * AI = On-delay DI = Interval GI = Pulse delayed SW = Symmetrical flasher (starting pulse on) No. of poles 2 = 2 pole - 10 A 3 = 3 pole - 10 A 4 = 4 pole - 7 A Supply voltage 012 = 12 V AC/DC 024 = 24 V AC/DC 048 = 48 V AC/DC 125 = (110…125)V AC/DC 240 = (230…240)V AC Supply version 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) for 240 V only Technical data Insulation Dielectric strength 85.02, 85.03 85.04 between input and output circuit V AC 2000 2000 between open contacts V AC 1000 1000 between adjacent contacts V AC 2000 1550 Insulation (1.2/50 µs) between input and output kV 6 4 EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 n.a. air discharge EN 61000-4-2 8 kV Radio-frequency electromagnetic field (80 ÷ 1000 MHz) EN 61000-4-3 15 V/m Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV Surges (1.2/50 µs) on common mode EN 61000-4-5 4 kV Supply terminals differential mode EN 61000-4-5 2 kV Radio-frequency common mode (0.15 ÷ 80 MHz) on Supply terminals EN 61000-4-6 10 V Power-frequency (50 Hz) EN 61000-4-8 30 A/m Radiated and conducted emission EN 55022 class B Other data Power lost to the environment without contact current W 1.6 Times scales NOTE: time scales and functions must be set before energising the timer. Miniature plug-in timers 7 - 10 A85 SERIES
III-2016, www.findernet.com H Functions U = Supply voltage = Output contact LED Supply voltage NO (SPDT-NO) output contact Contacts Open Closed OFF Open x1 - x4 x1 - x2 ON Open x1 - x4 x1 - x2 ON Open (Timing in Progress) x1 - x4 x1 - x2 ON Closed x1 - x2 x1 - x4 Wiring diagram Type: 85.02, 85.03, 85.04 85.02 85.03 85.04 (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. (GI) Pulse delayed. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5 s. (SW) Symmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off ). U = Supply voltage S = Signal switch Uc = Supply voltage to the timer 11-14 = Self-holding contact = Output contact Signal ON Pulse On mometary closure of Signal Switch (S) > 50 ms, the output contacts transfer and remain so (with self- holding on contact 11-14) for the duration of the preset delay, after which they reset. SERIES Miniature plug-in timers 7 - 10 A
III-2016, www.findernet.com H 94.P4 Approvals (according to type): 060.72 060.48 Push-in terminal socket panel or 35 mm (EN 60715) rail mount 94.P3 Blue 94.P4 Blue For timer type 85.03 85.02, 85.04 Accessories Metal retaining clip 094.81 6-way jumper link 094.56 Identification tag 094.00.4 2-way jumper link 094.52 2-way jumper link 097.52 Marker tag holder 097.00 Sheet of marker tags for marker tag holder 097.00 , 48 tags, 6 x 12 mm for CEMBRE's thermal transfer printers 060.48 Sheet of marker tags for marker tag holder 097.00, 72 tags, 6 x 12 mm 060.72 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –40…+70 Wire strip length mm 8 Min. wire size for 94.P3 and 94.P4 sockets solid wire stranded wire mm 2 0.5 0.5 AWG 21 21 Max. wire size for 94.P3 and 94.P4 sockets solid wire stranded wire mm2 2 x 1.5 / 1 x 2.5 2 x 1.5 / 1 x 2.5 AWG 2 x 18 / 1 x 14 2 x 18 / 1 x 14 94.P494.P3 094.56 EUROPEAN EUROP E AN PATENT 6-way jumper link for 94.P3 and 94.P4 sockets 094.56 (blue) Rated values 10 A - 250 V 094.52 2-way jumper link for 94.P3 and 94.P4 sockets 094.52 Rated values 10 A - 250 V 097.52 2-way jumper link for 94.P3 and 94.P4 sockets 097.52 Rated values 10 A - 250 V 097.00 Marker tag holder for 94.P3 and 94.P4 sockets 097.00
94 SERIES
Sockets and accessories for 85 series timers85 SERIES
III-2016, www.findernet.com H 94.04 Approvals (according to type): 060.72 060.48 Screw terminal (Box clamp) socket panel or 35 mm (EN 60715) rail mount 94.02 Blue 94.02.0 Black 94.03 Blue 94.03.0 Black 94.04 Blue 94.04.0 Black For timer type 85.02 85.03 85.04 Accessories Metal retaining clip 094.81 Identification tag 094.00.4 Marker tag holder 097.00 Sheet of marker tags marker tag holder 097.00 , 48 tags, 6 x 12 mm for CEMBRE's thermal transfer printers 060.48 Sheet of marker tags for marker tag holder 097.00, 72 tags, 6 x 12 mm 060.72 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –40…+70 Screw torque Nm 0.5 Wire strip length mm 8 Max. wire size for 94.02/03/04 sockets solid wire stranded wire mm2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 094.06 EUROPEAN EUROP E AN PATENT Rated values 10 A - 250 V SERIES Sockets and accessories for 85 series timers
III-2016, www.findernet.com H 94.84.2 Approvals (according to type): Screw terminal (Box clamp) socket panel or 35 mm (EN 60715) rail mount 94.84.2 Blue 94.84.20 Black For timer type 85.02, 85.04 Accessories Metal retaining clip (supplied with socket - packaging code SMA) 094.81 6-way jumper link 094.06 094.06.0 Identification tag 094.80.3 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –40…+70 Screw torque Nm 0.5 Wire strip length mm 7 Max. wire size for 94.84.2 socket solid wire stranded wire mm2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 94.84.2 Top terminals Bottom terminals 094.06 EUROPEAN EUROP E AN PATENT Rated values 10 A - 250 V Sockets and accessories for 85 series timers85 SERIES
III-2016, www.findernet.com H 94.94.3 Approvals (according to type): Screw terminal (Box clamp) socket panel or 35 mm rail mount 94.92.3 (blue) 94.92.30 (black) 94.94.3 (blue) 94.94.30 (black) For timer type 85.02 85.04 Accessories Metal retaining clip 094.81 Identification tag 094.80.3 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –25…+70 Screw torque Nm 0.5 Wire strip length mm 8 mm2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 Top terminals Bottom terminals 94.94.3 094.06 EUROPEAN EUROP E AN PATENT Rated values 10 A - 250 V SERIES Sockets and accessories for 85 series timers
III-2016, www.findernet.com H 94.74 Approvals (according to type): 94.82 Approvals (according to type): Screw terminal (Plate clamp) socket panel or 35 mm rail (EN 60715) mount 94.72 Blue 94.72.0 Black 94.73 Blue 94.73.0 Black 94.74 Blue 94.74.0 Black For timer type 85.02 85.03 85.02, 85.04 Accessories Metal retaining clip (supplied with timer) 094.81 Screw terminal socket panel or 35 mm rail (EN 60715) mount 94.82 Blue 94.82.0 Black For timer type 85.02 85.02 Accessories Metal retaining clip (supplied with timer) 094.81 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –40…+70 Screw torque Nm 0.5 Wire strip length mm 8 (94.72, 94.73, 94.74) 9 (94.82) mm 2 1 x 2.5 / 2 x 1.5 1 x 2.5 / 2 x 1.5 AWG 1 x 14 / 2 x 16 1 x 14 / 2 x 16 94.72 94.73 94.74 94.82 Sockets and accessories for 85 series timers85 SERIES