56.32 FINDER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 10

Technical content

XI-2016, www.findernet.com A SERIES

56 SERIES

Miniature power relays 12 A Plug-in - 12 A Power relay, 2 & 4 pole

  • Flange mount option - (Faston 187, 4.8 x 0.5 mm termination)
  • AC coils & DC coils
  • Lockable test button and mechanical flag indicator
  • Cadmium Free contacts (standard version)
  • Contact material options
  • 96 series sockets
  • Coil EMC suppression
  • Accessories
  • European Patent 56.32 56.32-0300 56.34 56.32/56.34 56.32-0300
  • 2 or 4 pole changeover contact
  • Plug-in/Faston 187
  • 2 pole normally open contact (≥ 1.5 mm gap)
  • Plug-in/Faston 187 * For 4 CO (4PDT) only. For UL ratings see: “General technical information” page V 56.32 56.34 56.32-0300 Contact specification Contact configuration 2 CO (DPDT) 4 CO (4PDT) 2NO (DPST-NO) - ≥ 1.5 mm gap Rated current/Maximum peak current A 12/20 12/20 Rated voltage/ Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 3000 3000 Rated load AC15 (230 V AC) VA 700 700 Single phase motor rating (230 V AC) kW 0.55 0.55 Breaking capacity DC1: 30/110/220 V A 12/0.5/0.25 12/1/0.5 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400* V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 — Rated power AC/DC VA (50 Hz)/W 1.5/1 2/1.3 1.5/— Operating range AC (0.8…1.1)UN (0.85…1.1)UN Holding voltage AC/DC 0.8 UN / 0.6 UN 0.85 UN/— Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN/— Technical data Mechanical life AC/DC cycles 20 · 106/50 · 106 20 · 106/— Operate/release time ms 8/3 10/4 8/4 Insulation between coil and contacts (1.2/50 μs) kV 4 5 4 Dielectric strength between open contacts V AC 1000 2000 Ambient temperature range °C –40…+70 –40…+70 Environmental protection RT I RT I Approvals (according to type)

XI-2016, www.findernet.com A Miniature power relays 12 A56 SERIES Printed circuit mount

12 A Power relay

  • 2 & 4 pole
  • AC coils & DC coils
  • Cadmium Free contacts (standard version)
  • Contact material option
  • RT III (wash tight) option available 56.44 56.42-0300 56.42 56.42/56.44 56.42-0300
  • 2 or 4 pole changeover contact
  • PCB mount
  • 2 pole normally open contact (≥ 1.5 mm gap)
  • PCB mount * For 4 CO (4PDT) only. For UL ratings see: “General technical information” page V 56.42 Copper side view 56.44 Copper side view 56.42-0300 Copper side view Contact specification Contact configuration 2 CO (DPDT) 4 CO (4PDT) 2NO (DPST-NO) - ≥ 1.5 mm gap Rated current/Maximum peak current A 12/20 12/20 Rated voltage/ Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 3000 3000 Rated load AC15 (230 V AC) VA 700 700 Single phase motor rating (230 V AC) kW 0.55 0.55 Breaking capacity DC1: 30/110/220 V A 12/0.5/0.25 12/1/0.5 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400* V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 — Rated power AC/DC VA (50 Hz)/W 1.5/1 2/1.3 1.5/— Operating range AC (0.8…1.1)UN (0.85…1.1)UN Holding voltage AC/DC 0.8 UN / 0.6 UN 0.85 UN/— Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN/— Technical data Mechanical life AC/DC cycles 20 · 10 6/50 · 106 20 · 106/— Operate/release time ms 8/3 10/4 8/4 Insulation between coil and contacts (1.2/50 μs) kV 4 5 4 Dielectric strength between open contacts V AC 1000 2000 Ambient temperature range °C –40…+70 –40…+70 Environmental protection RT I RT I Approvals (according to type)

XI-2016, www.findernet.com A SERIES Miniature power relays 12 A

Ordering information

Example: 56 series plug-in relay, 2 CO (DPDT), 12 V DC coil, lockable test button and mechanical indicator. A B C D 5 6 . 3 2 . 9 . 0 1 2 . 0 0 4 0 Series Type 3 = Plug-in 4 = PCB No. of poles 2 = 2 pole, 12 A 4 = 4 pole, 12 A Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications A: Contact material 0 = Standard AgNi 2 = AgCdO 4 = AgSnO B: Contact circuit 0 = CO (nPDT) 3 = NO (nPST), ≥ 1.5 mm contact gap D: Special versions 0 = Standard 1 = Wash tight (RT III) for 56.42 and 56.44 only 6 = Rear flange mount (4 pole only) 8 = Rear 35 mm rail mount (4 pole only) For other mounting options see page 6 C: Options 0 = None 2 = Mechanical indicator 3* = LED (AC) 4 = Lockable test button+mechanical indicator 5* = Lockable test button + LED (AC) 54* = Lockable test button + LED (AC) + mechanical indicator 6* = Double LED (DC non-polarized) 7* = Lockable test button + double LED (DC non-polarized) 74* = Lockable test button + double LED (DC non-polarized) + mechanical indicator 8* = LED + diode (DC, polarity positive to pin 7) for 56.32 only 9* = Lockable test button + LED + diode (DC, polarity positive to pin 7) for 56.32 only 94* = Lockable test button + LED + diode (DC, polarity positive to pin 7) + mechanical indicator for 56.32 only * Options not available for 220 V DC and 400 V AC versions. Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B C D 56.32 AC 0 - 2 - 4 0 0 - 2 - 3 - 4 - 5 0 AC 0 - 2 - 4 0 54 / AC 0 - 2 - 4 3 0 - 3 - 5 0 DC 0 - 2 - 4 0 0 - 2 - 4 - 6 - 7 - 8 - 9 0 DC 0 - 2 - 4 0 74 - 94 / 56.34 AC 0 - 2 - 4 0 0 - 2 - 3 - 4 - 5 0 - 6 - 8 AC 0 - 2 - 4 0 54 / DC 0 - 2 - 4 0 0 - 2 - 4 - 6 - 7 0 - 6 - 8 DC 0 - 2 - 4 0 74 /

56.42 DC 0 - 2 - 4 0 0 0 - 1

AC 0 - 2 - 4 0 - 3 0 0 - 1

56.44 AC - DC 0 - 2 - 4 0 0 0 - 1

Special versions for Rail Applications on request Descriptions: options and special versions C: Option 3, 5, 54 LED (AC) C: Option 6, 7, 74 Double LED (DC non-polarized) C: Option 8, 9, 94 LED + diode (DC, polarity positive to pin 7) - (56.32 only) Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074, 0090, 0094) The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. EU ROPEAN EUROP E AN PATENT

XI-2016, www.findernet.com A Miniature power relays 12 A56 SERIES Technical data * Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection. Insulation according to EN 61810-1 2 CO - 4 CO 2 NO Nominal voltage of supply system V AC 230/400 230/400 Rated insulation voltage V AC 250 400 250 400 Pollution degree 3 2 3 2 Insulation between coil and contact set Type of Insulation Basic Basic Overvoltage category III III Rated impulse voltage kV (1.2/50 μs) 4 4 Dielectric strength V AC 2500 2500 Insulation between adjacent contacts Type of insulation Basic Basic Overvoltage category III III Rated impulse voltage kV (1.2/50 μs) 4 4 Dielectric strength V AC 2500 2500 Insulation between open contacts Type of disconnection Micro-disconnection Full-disconnection* Overvoltage category — II Rated impulse voltage kV (1.2/50 μs) — 2.5 Dielectric strength V AC/kV (1.2/50 μs) 1000/1.5 2000/3 Conducted disturbance immunity Burst (5…50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 μs) on A1 - A2 (differential mode) EN 61000-4-5 level 4 (4 kV) Other data Bounce time: NO/NC ms 1/4 (changeover) 3/— (normally open) Vibration resistance (5…55)Hz: NO/NC g 17/14 Shock resistance g 20/14 Recommended distance between relays mounted on PCB mm ≥ 5 Contact specification 2 - 4 pole relays Cycles Resistive load - cosφ = 1 Inductive load - cosφ = 0.4 H 56 - Maximum DC1 breaking capacity Changeover version H 56 - Maximum DC1 breaking capacity Normally open version contacts in series DC breaking current (A) DC voltage (V) contacts in series DC breaking current (A) DC voltage (V)

  • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected.
  • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time of the load will be increased.

XI-2016, www.findernet.com A SERIES Miniature power relays 12 A Coil specifications DC coil data, 2 pole relay Nominal voltage Coil code Operating range Resistance Rated coil consumption UN Umin Umax R I at UN V V V Ω mA 6 9.006 4.8 6.6 40 150 12 9.012 9.6 13.2 140 86 24 9.024 19.2 26.4 600 40 48 9.048 38.4 52.8 2400 20 60 9.060 48 66 4000 15 110 9.110 88 121 12500 8.8 125 9.125 100 138 17300 7.2 220 9.220 176 242 54000 4 AC coil data, 2 pole relay Nominal voltage Coil code Operating range Resistance Rated coil consumption UN Umin* Umax R I at UN (50 Hz) V V V Ω mA 6 8.006 4.8 6.6 12 200 12 8.012 9.6 13.2 50 97 24 8.024 19.2 26.4 190 53 48 8.048 38.4 52.8 770 25 60 8.060 48 66 1200 21 110 8.110 88 121 3940 12.5 120 8.120 96 132 4700 12 230 8.230 184 253 17000 6 240 8.240 192 264 19100 5.3 * Umin = 0.85 UN for normally open version. DC coil data, 4 pole relay Nominal voltage Coil code Operating range Resistance Rated coil consumption UN Umin Umax R I at UN V V V Ω mA 6 9.006 5.1 6.6 32.5 185 12 9.012 10.2 13.2 123 97 24 9.024 20.4 26.4 490 49 48 9.048 40.8 52.8 1800 27 60 9.060 51 66 3000 20 110 9.110 93.5 121 10400 10.5 125 9.125 107 138 14200 8.8 220 9.220 187 242 44000 5 AC coil data, 4 pole relay Nominal voltage Coil code Operating range Resistance Rated coil consumption UN Umin Umax R I at UN (50 Hz) V V V Ω mA 6 8.006 4.8 6.6 5.7 300 12 8.012 9.6 13.2 22 150 24 8.024 19.2 26.4 81 90 48 8.048 38.4 52.8 380 37 60 8.060 48 66 600 30 110 8.110 88 121 1900 16.5 120 8.120 96 132 2560 13.4 230 8.230 184 253 7700 9 240 8.240 192 264 10000 7.5 400 8.400 320 440 26000 4.9 R 56 - DC coil operating range v ambient temperature 2 pole relay R 56 - AC coil operating range v ambient temperature 2 pole relay1 normally open version changeover version R 56 - DC coil operating range v ambient temperature 4 pole relay R 56 - AC coil operating range v ambient temperature 4 pole relay1 changeover version 2 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.

XI-2016, www.findernet.com A Miniature power relays 12 A56 SERIES Accessories 056.25 056.25 with relay Top flange mount adaptor for 56.32 056.25 056.25 056.25 with relay 056.26 056.26 with relay Rear flange mount adaptor for 56.32 056.26 056.26 056.26 with relay 056.27 056.27 with relay Top 35 mm rail (EN 60715) adaptor for 56.32 056.27 056.27 056.27 with relay 056.45 056.45 with relay Top flange mount adaptor for 56.34 056.45 056.45 056.45 with relay 056.47 056.47 with relay Top 35 mm rail (EN 60715) adaptor for 56.34 056.47 056.47 056.47 with relay Sheet of marker tags for relay type 56.34, plastic, 48 tags, 6 x 12 mm, for CEMBRE’s thermal transfer printers 060.48 060.48

XI-2016, www.findernet.com A SERIES

96 SERIES

Sockets and accessories for 56 series relays 96.02 Approvals (according to type): 96.04 Approvals (according to type): 094.91.3 Screw terminal (Box clamp) socket panel or 35 mm rail mount (EN 60715) 96.02 Blue 96.02.0 Black 96.04 Blue 96.04.0 Black For relay type 56.32 56.34 Accessories Metal retaining clip (supplied with socket - packaging code SMA) 094.71 096.71 Plastic retaining and release clip (supplied with socket - packaging code SPA) 094.91.3 094.91.30 — — 6-way jumper link 094.06 094.06.0 — — Identification tag 095.00.4 090.00.2 Modules (see table below) 99.02 Timer modules (see table below) 86.30 86.00, 86.30 Sheet of marker tags for retaining and release clip 094.91.3, plastic, 48 tags, 6 x 12 mm, for CEMBRE's thermal transfer printers 060.48 — Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –40…+70 (see diagram L96) Screw torque Nm 0.8 Wire strip length mm 8 Max. wire size for 94.02/04 sockets solid wire stranded wire mm2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 96.02 96.02 96.04 96.04 L 96 - Rated current vs ambient temperature Rated current (A) 86.00 86.30 99.02 094.06 EU ROPEAN EUROP E AN PATENT Approvals (according to type): DC Modules with non-standard polarity (+A2) on request. 6-way jumper link for 96.02 socket 094.06 (blue) 094.06.0 (black) Rated values 10 A - 250 V 86 series timer modules Multi-voltage: (12…240)V AC/DC; Approvals (according to type): 99.02 coil indication and EMC suppression modules for 96.02 and 96.04 sockets Diode (+A1, standard polarity) (6…220)V DC 99.02.3.000.00 LED (6…24)V DC/AC 99.02.0.024.59 LED (28…60)V DC/AC 99.02.0.060.59 LED (110…240)V DC/AC 99.02.0.230.59 LED + Diode (+A1, standard polarity) (6…24)V DC 99.02.9.024.99 LED + Diode (+A1, standard polarity) (28…60)V DC 99.02.9.060.99 LED + Diode (+A1, standard polarity) (110…220)V DC 99.02.9.220.99 LED + Varistor (6…24)V DC/AC 99.02.0.024.98 LED + Varistor (28…60)V DC/AC 99.02.0.060.98 LED + Varistor (110…240)V DC/AC 99.02.0.230.98 RC circuit (6…24)V DC/AC 99.02.0.024.09 RC circuit (28…60)V DC/AC 99.02.0.060.09 RC circuit (110…240)V DC/AC 99.02.0.230.09 Residual current by-pass (110…240)V AC 99.02.8.230.07

XI-2016, www.findernet.com A Sockets and accessories for 56 series relays56 SERIES 96.72 Approvals (according to type): 96.74 Approvals (according to type): Screw terminal (Plate clamp) socket panel or 35 mm rail (EN 60715) mount 96.72 Blue 96.72.0 Black 96.74 Blue 96.74.0 Black For relay type 56.32 56.34 Accessories Metal retaining clip (supplied with socket - packaging code SMA) 094.71 096.71 Modules (see table below) 99.01 Technical data Rated values 12 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –40…+70 Screw torque Nm 0.8 Wire strip length mm 10 Max. wire size for 96.72 and 96.74 sockets solid wire stranded wire mm2 1 x 4 / 2 x 4 1 x 4 / 2 x 2.5 AWG 1 x 12 / 2 x 12 1 x 12 / 2 x 14 96.72 96.74 99.01 Approvals (according to type): * Modules in Black housing are available on request. Green LED is standard. Red LED available on request. 99.01 coil indication and EMC suppression modules for types 96.72 and 96.74 sockets Blue* Diode (+A1, standard polarity) (6…220)V DC 99.01.3.000.00 Diode (+A2, non-standard polarity) (6…220)V DC 99.01.2.000.00 LED (6…24)V DC/AC 99.01.0.024.59 LED (28…60)V DC/AC 99.01.0.060.59 LED (110…240)V DC/AC 99.01.0.230.59 LED + Diode (+A1, standard polarity) (6…24)V DC 99.01.9.024.99 LED + Diode (+A1, standard polarity) (28…60)V DC 99.01.9.060.99 LED + Diode (+A1, standard polarity) (110…220)V DC 99.01.9.220.99 LED + Diode (+A2, non-standard polarity) (6…24)V DC 99.01.9.024.79 LED + Diode (+A2, non-standard polarity) (28…60)V DC 99.01.9.060.79 LED + Diode (+A2, non-standard polarity) (110…220)V DC 99.01.9.220.79 LED + Varistor (6…24)V DC/AC 99.01.0.024.98 LED + Varistor (28…60)V DC/AC 99.01.0.060.98 LED + Varistor (110…240)V DC/AC 99.01.0.230.98 RC circuit (6…24)V DC/AC 99.01.0.024.09 RC circuit (28…60)V DC/AC 99.01.0.060.09 RC circuit (110…240)V DC/AC 99.01.0.230.09 Residual current by-pass (110…240)V AC 99.01.8.230.07

XI-2016, www.findernet.com A SERIES Sockets and accessories for 56 series relays 96.12 Approvals (according to type): PCB socket 96.12 (blue) 96.12.0 (blue) 96.14 (blue) 96.14.0 (blue) For relay type 56.32 56.34 Accessories 094.51 Technical data Rated values 15 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature °C –40…+70 Copper side view 96.12 Copper side view 96.14 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: 9 6 . 7 4 S M A A Standard packaging SM Metal retaining clip SP Plastic retaining clip 9 6 . 7 4 Without retaining clip